• Title/Summary/Keyword: 최대호기압

Search Result 18, Processing Time 0.026 seconds

Maximal Inspiratory Pressure, Maximal Expiratory Pressure, and Maximum Phonation Time in Singers, Untrained Normal Person, and Patients with Vocal Cord Diseases (성악가와 성악훈련을 받지 않은 일반인과 성대질환이 있는 환자에서 최대흡기압, 최대호기압, 최대발성지속시간에 관한 연구)

  • 남도현;안철민;최홍식
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.13 no.2
    • /
    • pp.117-123
    • /
    • 2002
  • MIP was significantly increased in singers, compared to the untrained group. MIP in patients showed decreasing tendency compared to the untrained group, but were significantly lower than that in singers. MEP in singers was higher than that in the untrained group. MPT increased significantly in singers, but diminished in patients compared to the untrained group. MIP, MEP, and MPT in male singers were 50.8%, 61.0%, and 28.7 % higher than those in female singers. MIP, MEP, and MPT in the untrained male were more increased 32.3%, 25.0%, and 28.7%, respectively than those in the untrained female. There was no correlation between MPT and MIP or MEP. Regression analysis of the data set showed that weight and vocal cord dysfunction was a positive predictor of MPT. Factors affecting MIP were male, singers and weight. Factors affecting MEP were male, singers, vocal cord dysfunction and weight.

  • PDF

Pulmonary Functionn and the Maximal Inspiratory and Expiratory Pressure, and Maximum Phonation Time Before and After the Specially Programmed Training (호흡훈련보조기구를 이용한 호흡훈련 전 후의 폐기능 호흡근력과 최대발성지속시간의 변화)

  • 남도현;최홍식;안철민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.88-93
    • /
    • 2003
  • Whether respiratory muscle training is of benefit to the singing students is controversial. The purpose of the study is to investigate pulmonary function and the maximal inspiratory(MIP) and expiratory pressure(MET), and maximum phonation time in five female singing students before and after the specially programmed respiratory muscle training during 2 months. All singing students had average 4.8 years of formal classical voice training. Respiratory muscle training machine (Ultrabreath) was used to train respiratory muscle. Pulmonary function test data on simple pulmonary function, flow volume curve, static lung volumes are obtained from Vmax 6200. The MIP and MEP were measured using Spirovis, and the MPT were measured using hand-held stopwatch. Any pulmonary function test variables are not changed after respiratory muscle training. However, MIP and MEP were significantly increased between before and after respiratory muscle training. MPT increased significantly after training, compared to the pre-trained. MIP, MEP, and MPT after training in female singing students were 26%, 25% and 33% higher than those before training. The result indicated that the specially programmed respiratory muscle training is beneficial to improve respiratory muscle strength and vocal function without an increment in pulmonary function.

  • PDF

Experimental Study on the Slanted Portals for Reducing the Micro-pressure Waves in High-speed Train-tunnel System(I) (고속철도 터널에서 경사갱구 입구의 미기압파 저감성능에 관한 연구(I))

  • Kim, Dong-Hyeon;Shin, Min-Ho;Han, Myeong Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.2
    • /
    • pp.3-10
    • /
    • 2000
  • The compression wave produced when a high-speed train enters a tunnel propagates along the tunnel ahead of the train. The micro pressure wave related to the compression wave is a special physics phenomena created by high-speed train-tunnel interfaces. A among methods for the purpose of reducing the micro pressure wave is to delay the gradient of the compression wave by using aerodynamic structures. The objective of this paper is to determine the optimum slanted portal using the moving model rig. According to the results, the maximum value of micro pressure wave is reduced by 19.2% for the $45^{\circ}$ slanted portal installed at the entrance of the tunnel and reduced by 41.9% for the $45^{\circ}$ slanted portals at the entrance and exit of the tunnel. Also it is reduced by 34.6% for the $30^{\circ}$ slanted portals installed at the entrance and exit of the tunnel.

  • PDF

The Mechanism of Development of Cyclones in the Area of the Far East Asia (겨울철 극동 아세아의 저기압의 발달기구)

  • 한영호
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.12 no.1
    • /
    • pp.25-30
    • /
    • 1976
  • In the area of the Far East Asia, cyclones are observed 157ea in winter season during the years(1966-1974). Some of them are most difficult to be forecasted due to the extreme irregulalities, have carried out synoptic analysis. The rapid development of cyclones can be attributed to the descending of cold air mass surrounding the axis of the Jet Stream due to the cyclonic rotation, and the lowering of the Jet axis. The Relationships between upper trough line and max. (or min) axis of upper air temperature on the 700mb contributes to the development of the cyclones.

  • PDF

Experimental Study on the Slit Cover Hood for Reducing the Micro Pressure Waves in High-speed Train-tunnel Interfaces (고속철도에서 슬릿커버후드의 터널 미기압파 저감성능에 관한 연구(II))

  • Kim, Dong-Hyeon;Shin, Min-Ho;Han, Myeong Sik
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.2 no.3
    • /
    • pp.3-11
    • /
    • 2000
  • Purpose of this paper is to investigate the hood configuration at a tunnel entrance to reduce the micro pressure wave that is generated according to train speed. Two configurations were examined for the tunnel of 0.5 km in length. The experimental results show that a slit cover hood installed at the entrance of the tunnel reduces the maximum micro pressure wave by 41.2%, and the configuration with a slit cover hood installed at the entrance and the $45^{\circ}$ slanted portal at the exit of the tunnel suppress the pressure wave by 47.7%.

  • PDF

Differences in Respiratory Function and Vocal Aerodynamics between Professional Sopranos and Female Subjects without Vocal Training (훈련된 여자 성악가와 일반인의 호흡능력에 대한 비교 연구)

  • 최홍식;남도현;안철민;임성은;강성웅
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.12 no.2
    • /
    • pp.121-125
    • /
    • 2001
  • Singing requires exquisite coordination between the respiratory and phonatory system to efficiently control glottal airflow. Respiratory function and vocal aerodynamics were investigated in six female professional sopranos and in six female subjects without vocal training. All sopranos had more than 15 years of formal classic vocal training. Pulmonary function test data on simple pulmonary function, flow volume curve, static lung volumes, maximum inspiratory pressure(MIP), and maximum expiratory pressure(MEP) were obtained from all subjects. Vocal aerodynamic studies of maximum phonation time(MPT), phonation quotient, and mean glottal flow rates (MFR) were also measured in all subjects. Simple pulmonary function in professional sopranos was generally the same as that of other female subjects without vocal training. However, MIP and MEP showing respiratory muscle forces were significantly elevated in professional sopranos, compared to those of other female subjects without vocal training. Maximum phonation times and phonation quotient in sopranos are longer than those of other female subjects even though there were no differences in simple pulmonary function. High-pitched tones were made with significantly higher mean glottal flow rates(GFR) in normal subjects than low-pitched tones, whereas no changes in GFR were found in sopranos. The result indicated that sopranos demonstrated significant improvements in aerodynamic measures of GFR, maximum phonation time, suggesting an increase in glottal efficiency.

  • PDF

Hydrogen production by plasma pyrolysis-gasification of waste (폐기물의 플라즈마 열분해-가스화에 의한 수소생산)

  • Lee, Jin-Ho;Kim, Young-Suk;Do, Chul-Jin;Hwang, Soon-Mo;Jeong, Seong-Jae
    • New & Renewable Energy
    • /
    • v.3 no.4
    • /
    • pp.77-89
    • /
    • 2007
  • 폐기물의 플라즈마를 이용한 열분해-가스화-용융 처리공정은 청정연료 형태로 정화된 합성가스를 얻을 수 있고, 이 합성가스를 WGS 반응과 PSA 공법을 이용하면 고순도 수소로의 전환 및 회수가 가능하다. (주)애드플라텍에서는 자체 보유하고 있는 3톤/일급 플라즈마 폐기물 처리설비와 수소 정제/회수시스템을 연계하여, 페기물로부터 고순도 수소 생산($20Nm^3/h$이상)을 위한 플라즈마 폐기물 처리 추소 생산 통합시스템 개발을 진행하고 있다. 합성가스 내 질소 농도를 낮추기 위해 산소를 매질로 하는 100kw급 산소 플라즈마 토치를 제작하였다. 수소 정제/회수 시스템은 폐기물의 플라즈마 처리 후의 합성가스 생성량과 조성의 변화에 대응할 수 있도록 하였으며, WGS 반응기로 들어가는 합성가스를 가스 컴프레서를 통하여 최대 10기압으로 승압시키고, 고농도 일산화탄소의 효과적인 제거 및 열 회수 극대화가 이루어질 수 있는 최적의 가스처리 시스템으로 구현되도록 하였다. 설치 완료된 WGS 반응기의 성능시험을 플라즈마 처리설비와 연계하여 수행하였다. 합성가스 내 각각 34%와 25%의 일산화탄소 및 수소의 농도가 WGS 반응기를 거친 후, 일산화탄소는 0.1% 미만으로 제거되었으며 수소는 44%로 증가하여 WGS 반응기의 성능 수준이 매우 우수함을 확인하였다. 차기 년도에 설치/가동 예정인 수소 생산용 PSA는 최대 10기압 운전 및 상압재생 방식으로 운전되며 생산된 수소는 최소 99.99%이상의 고순도를 유지할 것으로 기대된다.

  • PDF

Hydrogen production by plasma pyrolysis-gasification of waste (폐기물의 플라즈마 열분해-가스화에 의한 수소생산)

  • Lee, Jin-Ho;Kim, Young-Suk;Do, Chul-Jin;Hwang, Soon-Mo;Jeong, Seong-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.627-632
    • /
    • 2007
  • 폐기물의 플라즈마를 이용한 열분해-가스화-용융 처리공정은 청정연료 형태로 정화된 합성가스를 얻을 수 있고, 이 합성가스를 WGS 반응과 PSA 공법을 이용하면 고순도 수소로의 전환 및 회수가 가능하다. (주)애드플라텍에서는 자체 보유하고 있는 3톤/일급 플라즈마 폐기물 처리설비와 수소 정제/회수시스템을 연계하여, 폐기물로부터 고순도 수소 생산 ($20Nm^3/h$ 이상)을 위한 플라즈마 폐기물 처리 수소 생산 통합시스템 개발을 진행하고 있다. 합성가스 내 질소 농도를 낮추기 위해 산소를 매질로 하는 100kW급 산소 플라즈마 토치를 제작 하였다. 수소 정제/회수 시스템은 폐기물의 플라즈마 처리 후의 합성가스 생성량과 조성의 변화에 대응할 수 있도록 하였으며 WGS 반응기로 들어가는 합성가스를 가스 컴프레서를 통하여 최대 10기압으로 승압시키고, 고농도 일산화탄소의 효과적인 제거 및 열 회수 극대화가 이루어질 수 있는 최적의 가스처리 시스템으로 구현되도록 하였다. 설치 완료된 WGS 반응기의 성능시험이 플라즈마 처리설비와 연계하여 수행되었으며 WGS 반응기를 거친 일산화탄소의 농도는 1.5% 미만으로 분석되었다. 차기 년도에 설치/가동 예정인 수소 생산용 PSA는 최대 10기압 운전 및 상압재생 방식으로 운전되며 생산된 수소는 최소 99.99%이상의 고순도를 유지할 것으로 기대된다.

  • PDF

Effects of Modified Ultrafiltration in Pediatric Open Heart Surgery (소아 개심술에 있어서 변형초여과법의 효과)

  • 전태국;박표원
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.591-597
    • /
    • 1997
  • Cardiopulmonary bypass in children is associated with capillary leak which results in an increase in total body water after open heart surgery The purpose of these studies was to assess the cardiopulmonary effects of modified ultrafiltration after pediatric open heart surgery Study h: Twenty-six consecutive children aged 0.1 ~ 10 years(median 7 months) underwent cardiac operation inc rporating modified ultrafiltration. After completion of cardiopulmonary bypass, modified ultrafiltration was commenced at the flow rate of 100~ 15011min for 3 ~ 14 min. After modified ultrafiltration, elevation of hematocrit(28.3% $\pm$ 3.6% vs. 33.8olo $\pm$ 4.Ooloi p < 0.001), increased systolic 1)loots Pressure(66.7 $\pm$ 11.2mmHg vs. 76.2$\pm$ 11.BmmHg, p < 0.02), and decreased central venous pressure(7.8 $\pm$ 3.7mmHg vs. 6.9$\pm$ 2.gmmHg, p<0.001) were observed. Study B: Twenty-six children who underwent cardiac operation with the diagnosis of VSD under 2 years were assigned to control(n= 14) or modified ultrafiltration(n= 12). Peak inspiratory pressure checked immediately after operation was significantly lower in modified ultrafiltration group than in control group(20.0$\pm$ 2.4 cmH20 vs.22.4$\pm$ 2.3cmH20, p < 0.03). Modified ultrafiltration after cardiopillmonary bypass in children improves early homodynamics and pulmonary mechanics, and represents an excellent option for perioperative managemen of accumulation of fluid in the tissues. We will continually employ the modified ultrafiltration technique in pediatric cardiac operations.

  • PDF