• Title/Summary/Keyword: 최대전력부하

Search Result 329, Processing Time 0.027 seconds

A Study on the DR program operation method based on the pattern analysis (사용량 패턴분석을 통한 패턴분석 DR 프로그램 운영방안에 대한 연구)

  • Kang, Jung-Chul;Lee, Hyun-Woo
    • Journal of the Korean Data and Information Science Society
    • /
    • v.20 no.2
    • /
    • pp.283-292
    • /
    • 2009
  • Recently the stable electric power supply is threaten by the rapid development of all the industries consuming a lot of electric power, thus KEPCO is trying to establish the countermeasures to cope with this circumstance of uprising power consumption by running the efficient and flexible 12-month s price policy for the base price and raisin the electric power price remarkably in peak power consumption period to suppress the maximal power demand of consumers. To resolve these problems, this study propose the method calculating hourly CBL based on the hourly amount at non-event using the pattern of the amount of power consumption and propose the operation method of DR Program.

  • PDF

The Generating Power Control of Coal-Fired Power Plant using Modeling Method (모델링 기법을 이용한 석탄화력발전소 발전기 출력제어)

  • Lim, Geon-Pyo;Kim, Ho-Yol
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.403-404
    • /
    • 2008
  • 자원의 고갈과 각종 환경규제 및 정부의 전력거래 방침 등으로 인해 점점 발전소에서는 전력 계통에 대한 신뢰도 및 전기품질을 유지하기가 어려워지고있다. 발전소의 부하대별 주요 운전 설계값은 효율과 바로 직결되는 사항으로 각 부하별로 온도와 압력 등 운전설계값을 최적의 상태로 유지하는 것은 발전소 수명과 발전효율, 전력거래 등에 있어 중요한 요소들이다. 전력시장에 진입하는 발전소는 전력계통의 갑작스런 불안성 상황이나 전력거래소 요청시 경사변동폭, 출력변통율, 무효전력 출력, 자동발전제어, 주파수조절량 확보 등을 수행할 수 있어야 한다. 본 논문에서는 고급공정제어기를 이용하여 운전설계계값을 효과적으로 제어 하면서 기존의 제어로직보다 전력계통상에서 요구되는 발전기 출력을 최대한 신속히 제어하는 과정을 기술하였다. 우선 보일러 마스터와 터빈 마스터, 급수 마스터로 구성된 제어로직을 설계한 뒤 이들 마스터에 대한 발전기 출력, 주증기 압력, 기수분리기 출구온도 각각의 영향을 모델링 기법을 이용하여 적합한 모델을 구했다. 각각의 모델을 고급공정제어기에 적용하고 발전기 출력제어에 대한 기존의 발전소 응답보다 좀 더 효율적이고 실제적용이 가능한 결과를 얻을 수 있도록 튜닝을 시행했으며 그 과정과 결과를 기술했다.

  • PDF

Foreign Experience of Deploying Demand-Side Resources as Reserve (수요측 자원의 예비력으로의 활용에 대한 해외사례보고)

  • Hahn, Tae-Kyung;Kim, Jin-Ho;Chun, Young-Hwan;Hong, Jun-Hee
    • Proceedings of the KIEE Conference
    • /
    • 2007.11b
    • /
    • pp.316-318
    • /
    • 2007
  • 전력수급에 있어서 공급측 자원을 대체하는 자원으로써 수요측 자원을 주목하는 가운데 그 활용분야로 수요측 자원을 예비력자원으로의 활용이 것이 연구되고 있다. 본 논문에서는 캘리포니아의 최대부하관리를 위한 에어컨 순환운전 프로그램을 수정하여 예비력자원으로 사용하려는 시도에 대해서 소개한다. 시연결과 부하측 자원은 반응속도와 신뢰성에 있어서 장점이 있지만 실제로 활용되기 위해서는 제도적인 뒷받침과 실제 운영 경험이 필요하다.

  • PDF

Performance Analysis of 6.78MHz Current Mode Class D Power Amplifier According to Load Impedance Variation (부하 임피던스 변화에 따른 6.78MHz 전류모드 D급 전력증폭기 특성 해석)

  • Go, Seok-Hyeon;Park, Dae-kil;Koo, Kyung-Heon
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.166-171
    • /
    • 2019
  • This paper has designed a current mode class D power amplifier to increase the transmission efficiency of a 6.78 MHz wireless power transfer (WPT) transmitter and to ensure stable characteristics even when the transmitting and receiving coil intervals change. By reducing the loss due to the parasitic capacitor component of the transistor, which limits the theoretical efficiency of the linear amplifier, this research has improved the efficiency of the power amplifier. The circuit design simulator was used to design the high efficiency amplifier, and the power output and efficiency characteristics according to the load impedance change have been simulated and verified. In the simulation, 42.1 dBm output and 95% efficiency was designed at DC bias 30 V. The power amplifier was fabricated and showed 91% efficiency at the output of 42.1 dBm (16 W). The transmitting and receiving coils were fabricated for wireless power transfer of the drone, and the maximum power added efficiency was 88% and the output power was $42.1dBm{\pm}1.7dB$ according to the load change causing from the coil intervals.

A Control Method of Phase Angle Regulator for Parallel-Feeding Operation of AC Traction Power Supply System (교류전기철도 병렬급전 운영을 위한 위상조정장치 제어기법)

  • Lee, Byung Bok;Choi, Kyu Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.5
    • /
    • pp.672-678
    • /
    • 2020
  • The parallel-feeding operation of an AC traction power supply system has the advantages of extending the power supply section and increasing the power supply capacity by reducing the voltage drop and peak demand caused by a train operation load. On the other hand, the parallel-feeding operation is restricted because of the circulating power flow induced from the phase difference between substations. Moreover, the power supply capacity is limited because of the unbalanced substation load depending on the trainload distribution, which can be changed by the train operation along the railway track. This paper suggests a Thyristor-controlled Phase Angle Regulator (TCPAR) to reduce the circulating power flow and the unbalanced substation load, which depends on the phase difference and the trainload distribution and provides a feasibility study. A dedicated control model of TCPAR is also provided, which uses substation power supplies as the input to control the circulating power flow and an unbalanced substation load depending on the phase difference and the trainload distribution. Simulation studies using PSCAD/EMTDC shows that the proposed TCPAR control model can reduce the circulating power flow and the unbalanced substation load depending on the phase difference and the trainload distribution. The proposed TCPAR can extend the parallel-feeding operation of an AC traction power system and increase the power supply capacity.

Experimental Performance Analysis using a Compact Scale Model for Shroud Tidal Current Power Generation System (쉬라우드 조류발전장치의 축소모형실험을 통한 발전 성능 분석)

  • Han, Seok Jong;Lee, Uk Jae;Park, Da In;Lee, Sang Ho;Jeong, Shin Tark;Lee, Sang Seol
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.31 no.4
    • /
    • pp.221-228
    • /
    • 2019
  • Experimental investigation was performed to analyze the flow field characteristics and power generation performance for a shroud tidal power generation system. Electrical power output was compared with the rotational speed of the turbine blade and electric load connected to the generator for various flow velocity. As the electrical load decreased, the speed of the turbine increased rapidly and reached by about 2 times. The power output also increased remarkably with the decrease of load, and then decreased after maximum power point. In addition, the maximum power point appeared at high electrical loads as the experimental flow velocity increased. These results of the flow field characteristics and power generation performance analysis of the shroud tidal power generation system variation with the flow velocity conditions and electrical load are expected to be the basic data necessary for the development of efficient shroud tidal power generation system.

공정현장 적응능력 평가를 위한 드라이펌프의 실시간 특성분석

  • Choe, Gyeong-Min;Kim, Wan-Jung;Jeong, Wan-Seop;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.145.2-145.2
    • /
    • 2014
  • 최근 반도체 산업의 급속한 발전으로 반도체 생산 설비 시설 또한 꾸준히 증설되어가는 추세이다. 이에 따라 반도체 산업의 핵심기술로 부각되고 있는 진공 기술은 다양한 응용목적을 위한 진공시스템 설계와 운영을 필요로 한다. 진공시스템의 알맞은 설계는 시스템 구성에 따른 진공특성을 예측하는 것이 중요하며 목적에 부합한 진공펌프를 선택하고 운영하여 최소비용으로 시스템 활용효율성을 극대화할 수 있는 설계를 해야 한다. 또한 공정의 저전력, 대유량화 추세에 따라 고유량 영역의 드라이펌프 부하 내구성 대응 요구에 부응하는 객관적 내구성평가의 정립 및 표준 측정 시험평가 방법의 필요성이 점차 대두되고 있는 경향에 있다. 본 연구에서는 드라이펌프의 공정현장 적응능력 평가를 위하여 최소 1시간에서 3시간동안 압력별 가스부하에 따른 드라이펌프의 실시간 특성을 관찰하였다. 실험은 1 mbar에서 최대 300 mbar까지의 연속적인 부하 조건에서 유량, 진동, 소음, 소비전력과 Sudden Vent Test를 실시간으로 측정하였고 드라이펌프의 특성 분석은 각 용량별 압력에 따른 유량, DP BP 소비전력, 소음, 진동, DP Body Temperature 등의 데이터를 Type에 따라 비교 분석하였다. 이에 부응하는 평가 장치 구축 및 데이터분석은 한국표준과학연구원 진공펌프 평가실험실에서 수행되었다.

  • PDF

An Analysis of Optimal Operation Strategy of ESS to Minimize Electricity Charge Using Octave (Octave를 이용한 전기 요금 최소화를 위한 ESS 운전 전략 최적화 방법에 대한 분석)

  • Gong, Eun Kyoung;Sohn, Jin-Man
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.85-92
    • /
    • 2018
  • Reductions of the electricity charge are achieved by demand management of the load. The demand management method of the load using ESS involves peak shifting, which shifts from a high demand time to low demand time. By shifting the load, the peak load can be lowered and the energy charge can be saved. Electricity charges consist of the energy charge and the basic charge per contracted capacity. The energy charge and peak load are minimized by Linear Programming (LP) and Quadratic Programming (QP), respectively. On the other hand, each optimization method has its advantages and disadvantages. First, the LP cannot separate the efficiency of the ESS. To solve these problems, the charge and discharge efficiency of the ESS was separated by Mixed Integer Linear Programming (MILP). Nevertheless, both methods have the disadvantages that they must assume the reduction ratio of peak load. Therefore, QP was used to solve this problem. The next step was to optimize the formula combination of QP and LP to minimize the electricity charge. On the other hand, these two methods have disadvantages in that the charge and discharge efficiency of the ESS cannot be separated. This paper proposes an optimization method according to the situation by analyzing quantitatively the advantages and disadvantages of each optimization method.

Traffic Load & Lifetime Deviation based Power-aware Routing Protocol for MANET (MANET에서 트래픽 부하와 노드 수명 편차에 기반한 power-aware 라우팅 프로토콜)

  • Kim, Dong-Hyun;Ha, Rhan
    • Journal of KIISE:Information Networking
    • /
    • v.33 no.5
    • /
    • pp.395-406
    • /
    • 2006
  • In ad hoc networks, the limited battery capacity of nodes affects a lifetime of network Recently, a large variety of power-aware routing protocols have been proposed to improve an energy efficiency of ad hoc networks. Existing power-aware routing protocols basically consider the residual battery capacity and transmission power of nodes in route discovery process. This paper proposes a new power-aware routing protocol, TDPR(Traffic load & lifetime Deviation based Power-aware Routing protocol), that does not only consider residual battery capacity and transmission power, but also the traffic load of nodes and deviation among the lifetimes of nodes. It helps to extend the entire lifetime of network and to achieve load balancing. Simulations using ns-2[14] show the performance of the proposed routing protocol in terms of the load balancing of the entire network, the consumed energy capacity of nodes, and an path's reliability TDPR has maximum 72% dead nodes less than AODV[4], and maximum 58% dead nodes less than PSR[9]. And TDPR consumes residual energy capacity maximum 29% less than AODV, maximum 15% less than PSR. Error messages are sent maximum 38% less than PSR, and maximum 41% less than AODV.

Steady-state analysis of LLC resonant converter for optimum design (LLC 공진형 컨버터의 최적 설계를 위한 정상상태 해석)

  • Nam Won-Seok;Han Sang-Kyu;Roh Chung-Wook;Hong Sung-Soo;SaKong Suk-Chin;Kim Chong-Sun
    • Proceedings of the KIPE Conference
    • /
    • 2006.06a
    • /
    • pp.375-377
    • /
    • 2006
  • 본 논문에서는 LLC 공진형 컨버터의 최적 설계를 위해, ZVS 영역에서 동작하는 LLC 공진형 컨버터의 최악의 상태에 대한 정상 상태 해석을 하였다. LLC 공진형 컨버터의 최악의 상태는 최소 입력 전압, 최대 부하 전류일 때 얻을 수 있는 최대 전압 이득을 의미한다. 설계 변수는 스위칭 주파수 범위와 공진 인덕터 비율로서, 각 설계 변수의 변화에 따른 공진 탱크 설계 값, 최악의 상태 출력 전압 그리고 최대 공진 캐패시터 전압을 보여주는 '최악의 조건 설계 표'를 나타내었으며, 설계된 특정 공진 탱크 값에 대한 시뮬레이션 결과와 실험 결과를 보였다.

  • PDF