A 0.18-μm CMOS Low-Power and Wideband LNA Using LC BPF Loads (광대역 LC 대역 통과 필터를 부하로 가지는 0.18-μm CMOS 저전력/광대역 저잡음 증폭기 설계)

  • Shin, Sang-Woon;Seo, Yong-Ho;Kim, Chang-Wan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.1
    • /
    • pp.76-80
    • /
    • 2011
  • This paper has proposed a 3~5 GHz low-power and wideband LNA(Low Noise Amplifier), which has been implemented in a 0.18-${\mu}m$ CMOS technology. The proposed LNA has basically the noise-cancelling topology to achieve a balun-function, wideband input matching, and relative low noise figure. In addition, it has utilized a 2nd-order LC-band-pass filter(BPF) as its output load to achieve higher power gain and lower noise figure with the lowest dc power consumption among previously reported works. The proposed amplifier consumes only 3.94 mA from a 1.8 V supply voltage. The simulation results show a power gain of more than +17 dB, a noise figure of less than +4 dB, and an input IP3 of -15.5 dBm.

The Analysis of Effect in Order to Consider Combined Heat and Power Capacity in the Basic Plan of Long Term Electricity Supply & Demand (전력수급기본계획에 열병합발전 설비 반영시의 효과분석에 관한 연구)

  • Kim, Yong-Ba;Moon, Jung-Ho;Yeon, Jun-Hee;Jung, Hyun-Sung;Woo, Sung-Min;Kim, Mi-Ye
    • Journal of Energy Engineering
    • /
    • v.16 no.1 s.49
    • /
    • pp.22-31
    • /
    • 2007
  • This paper addresses methodology in order to consider CHP (Combined Heat and Power) capacity in the Basic Plan of Long Term Electricity Supply & Demand and presents effects on it. The method performs state in extent that do not change maximum in the Basic Plan of Long Term Electricity Supply & Demand. For analysis that occurs some advantage this method compares with Basic Plan of Long Term Electricity Supply & Demand. It includes EES (Expected Energy Served), Fuel consumption, amount of $CO_{2}$ emission reduction.

A Study on Decision Plan of Hosting Capacity for Distribution Feeder (배전선로 연계용량 선정방안에 관한 연구)

  • Kim, Seong-Man;Oh, Joon-Seok;Kim, Ok-Hee;Lim, Hyeon-Ok;Moon, Chae-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.4
    • /
    • pp.653-660
    • /
    • 2021
  • Renewable energy resources are rapidly becoming an integral part of electricity generation portfolios around the world due to declining costs, government subsidies, and corporate sustainability goal. Interacting wind, solar, and load forecast errors can create significant unpredictable impacts on the distribution system, feeder congestion, voltage standard and reactive power stability margins. These impacts will be increasing with the increasing penetration levels of variable renewable generation in the power systems. There is a limit to the maximum amount of renewable energy sources that can be connected in a distribution feeder by the connection rule of transmission & distribution facility in Korea. This study represents the decision plans of hosting capacity for distribution feeders without the need for significant upgrades to the existing transmission infrastructure. Especially, the paper suggests and discusses the hosting capacity standard of feeder cables and minimum load calculation of distribution feeders.

Optimal Control of a Three-Phase Voltage-Source PWM Converter with an Expanded Operation Region (확장된 동작 영역을 갖는 3상 전압원 PWM 컨버터의 최적 제어)

  • 민동기;안성찬;현동석;최종률
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.156-164
    • /
    • 1998
  • The operation regions of a three-phase(3Ø) voltage-source(VS) PWM converter are classified in the current vector plane of the synchronous reference frame and their characteristics are explained. In the the power-factor decreasing region, the current control with unity power-factor can not give satisfactory performance to the given load because of the distortion of input current and the ripples and the steady-state errors in DC link voltage. In this paper, the derivation of the optimal current vector is proposed to solve these problems. With this, the input current can be controlled sinusoidally with available maximum power factor and the DC link voltage be the given load, resulting the expansion of the operation region of the 3Ø VS PWM converter. The validity of the proposed control method is proved by the experimental results.

Short-term Peak Power Demand Forecasting using Model in Consideration of Weather Variable (기상 변수를 고려한 모델에 의한 단기 최대전력수요예측)

  • 고희석;이충식;최종규;지봉호
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.2 no.3
    • /
    • pp.73-78
    • /
    • 2001
  • BP neural network model and multiple-regression model were composed for forecasting the special-days load. Special-days load was forecasted using that neural network model made use of pattern conversion ratio and multiple-regression made use of weekday-change ratio. This methods identified the suitable as that special-days load of short and long term was forecasted with the weekly average percentage error of 1∼2[%] in the weekly peak load forecasting model using pattern conversion ratio. But this methods were hard with special-days load forecasting of summertime. therefore it was forecasted with the multiple-regression models. This models were used to the weekday-change ratio, and the temperature-humidity and discomfort-index as explanatory variable. This methods identified the suitable as that compared forecasting result of weekday load with forecasting result of special-days load because months average percentage error was alike. And, the fit of the presented forecast models using statistical tests had been proved. Big difficult problem of peak load forecasting had been solved that because identified the fit of the methods of special-days load forecasting in the paper presented.

  • PDF

PAPR-minimized Sequence Mapping with Data Space Reduction by Partial Data Side Information in OFDM System (OFDM 시스템에서 부분 데이터 추가정보를 이용한 데이터 공간 감소를 갖는 최대 전력 대 평균 전력 비 최소화 시퀀스 사상 기법)

  • Jin Jiyu;Ryu Kwan Woongn;Park Yong wan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.12A
    • /
    • pp.1340-1348
    • /
    • 2004
  • In this paper, we propose a PAPR-minimized sequence mapping scheme that achieves the minimum Peak-to-Average Power Ratio (PAPR) and the minimum amount of computations for the OFDM system. To reduce the PAPR, the mapping table is created with information about block index and symbol patterns of the lower signal power. When the input data sequence comes, it performed division by the block length to find the quotient and remainder. The symbol pattern of the lower signal power can be found in terms of the block index as the quotient in the mapping table and transmitted with remainder as the side information to distinguish and recover the original data sequence in the receiver. The two methods with the proposed mapping scheme are proposed in this paper. One is with mapping table to recover the O%M signal in both transmitter and receiver. The other is with mapping table only in transmitter to reduce the load and the complexity in the mobile system. We show that this algorithm provides the PAPR reduction, the simple processing and less computational complexity to be implemented for the multi-carrier system.

Design and Implementation of Class-AB High Power Amplifier for IMT-2000 System (IMT-2000용 Class-AB 대전력증폭기의 설계 및 구현)

  • 차용성;이재성;강병권;박준석
    • Proceedings of the KAIS Fall Conference
    • /
    • 2002.11a
    • /
    • pp.197-200
    • /
    • 2002
  • 본 논문에서는 IMT-2000용 AB급 대전력 증폭기를 설계 및 제작하였다. 전력증폭기의 주파수 대역은 IMT-2000용 순방향 주파수인 2110MHz-2170MHz에서 AB급으로 동작하도록 하였고, 고효율성과 우수한 선형성 소자인 LDMOSFET를 사용하였다. 설계 특성에 맞는 최적부하를 찾아 마이크로 스트립 회로로 입력 및 출력 정합 회로를 구현하였다 임피던스 정합 방법으로는 소자를 실제 측정상태에서 입력단과 출력단에 튜너를 삽입하고 기본 주파수에서 최대 출력상태를 만족하는 임피던스를 튜너로 구현한 후, 튜너를 제거하고 튜너의 입력 임피던스를 Network Analyzer로 측정하여 최적 부하 임피던스를 추출하는 로드풀 방법을 사용하였다. 대전력 증폭기의 측정결과로는 2-톤 인가시 40.57dBm의 출력결과를 얻을 수 있었고 30.61dBc의 상호 혼변조 특성을 확인하였으며, 원신호의 하모닉(Hamonic) 주파수 성분과는 21.46dBc의 차이를 보였다.

PSTCP : A Tool to Evaluate Power System Transfer Capability (전력계토의 수송능력 평가 프로그램 개발에 관한 연구)

  • Yu, Su-Hyeon;Jeong, Jong-Hun;Jeong, Min-Hwa;Lee, Byeong-Jun;Song, Gil-Yeong;Sin, Yeong-Cheol;Kim, Yeong-Seon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.7
    • /
    • pp.872-880
    • /
    • 1999
  • This paper presents an algorithm that can calculate the evaluation index of power system from the transfer capability point of view. The algorithm adopts a successive linear programming skill to solve an optimal solution. Two indices which are transfer margin index and economic matching index have been developed. Prior to calculating these indices, Maximum Load supplying Capability(MLSC) and Economic Load Supplying Capability(ELSC) are utilized as basic data. For man-machine interface, graphical user interface has been implemented so that an unified software package PSTCP(Power System Transfer Capability Program) has been developed. KEPCO systems planned up to 2006 year have been tested to show effectiveness and usefulness of the PSTCP for power system planning stages.

  • PDF

A Study on the Construction of the Flexible Long-Term Generation Mix under Uncertainties of Power System (전력계통의 불확실성을 포함한 유연한 장기전원구성의 수립에 관한 연구)

  • 최재석;이순영;송길영
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.4 no.1
    • /
    • pp.64-80
    • /
    • 1994
  • 본 연구에서는 장기전원구성의 수립에 있어서 가정한 시나리오에서 최적해를 찾는 기존의 방법을 탈피하여 건설단가나 연료단가의 변동과 같은 경제성의 변동 및 최대부하의 예측의 불확실성에 대한 외부충격등에 견딜 수 있는 유연성을 정량적으로 고려할 수 있는 새로운 방법을 제안한다.그 수법으로 Fuzzy 동적계획법을 이용하여 각 대표년도별로 최적전원구성안을 결정하므로써 년도별 전원 구성의 추이를 쉽게 알 수 있고 비선형 멤버쉽함수도 용이하게 고려할 수 있도록 하였다. 여기서는 경제성, 신뢰성, 부하불확실성 및 유연성에 대한 멤버쉽 함수치를 각상태별로 계산하고 Bellman-Zadeh의 최대화 결전과정에 따라 처리하므로서 그 안을 결정하도록 하였다. 본 수법을 우리나라 KEPCO 계통에 적용하여 그 유용성을 검토하였다.

  • PDF

Through load prediction and solar power generation prediction ESS operation plan(Guide-line) study (부하예측 및 태양광 발전예측을 통한 ESS 운영방안(Guide-line) 연구)

  • Lee, Gi-Hyun;Kwak, Gyung-il;Chae, U-ri;KO, Jin-Deuk;Lee, Joo-Yeoun
    • Journal of Digital Convergence
    • /
    • v.18 no.12
    • /
    • pp.267-278
    • /
    • 2020
  • ESS is an essential requirement for resolving power shortages and power demand management and promoting renewable energy at a time when the energy paradigm changes. In this paper, we propose a cost-effective ESS Peak-Shaving operation plan through load and solar power generation forecast. For the ESS operation plan, electric load and solar power generation were predicted through RMS, which is a statistical measure, and a target load reduction guideline for one hour was set through the predicted electric load and solar power generation amount. The load and solar power generation amount from May 6th to 10th, 2019 was predicted by simulation of load and photovoltaic power generation using real data of the target customer for one year, and an hourly guideline was set. The average error rate for predicting load was 7.12%, and the average error rate for predicting solar power generation amount was 10.57%. Through the ESS operation plan, it was confirmed that the hourly guide-line suggested in this paper contributed to the peak-shaving maximization of customers.Through the results of this paper, it is expected that future energy problems can be reduced by minimizing environmental problems caused by fossil energy in connection with solar power and utilizing new and renewable energy to the maximum.