• Title/Summary/Keyword: 최대온도

Search Result 3,236, Processing Time 0.033 seconds

Study on Ventilation Efficiency of a Mechanically Ventilated Broiler House­(I)Summer Season (강제환기식 육계사내의 환기효율성 조사연구­(I)하절기)

  • 이인복;정문성;유병기;전종기;김경원;이승기
    • Journal of Animal Environmental Science
    • /
    • v.9 no.2
    • /
    • pp.103-112
    • /
    • 2003
  • In this study, the distributions of internal climates such as air temperature, humidity, dust, ammonia gas, and air velocity were systematically measured at a mechanically ventilated broiler houses during summer season, with local weather data. The analysis was focused on the suitability, stability, and uniformity of internal climate, resulting in serious stress on chickens and decrease of productivity In the mechanically ventilated broiler house, the difference between measured and recommended air temperatures(suitability) was 10.4C in maximum during the summer time. The difference of air temperature in the house between day and night was $8.7^{\circ}C$ in maximum. And maximal hourly range of internal air temperature at 0.4m height from the floor was $3.7^{\circ}C$ suggesting it maintained thermal uniformity in the broiler house. The $NH_3$ and dust concentrations were pretty low because ventilation was fully performed. The air speed at chicken location was measured 2.2m/s and 1.7m/s, respectively without and with chicken existence.

  • PDF

Thermal Analysis of a Retrievable CANDU Spent Fuel Disposal Tunnel (회수 가능 CANDU 사용후핵연료 처분터널에 대한 열 해석)

  • Cha, Jeong-Hun;Lee, Jong-Youl;Choi, Heui-Joo;Cho, Dong-Keun;Kim, Sang-Nyung;Youn, Bum-Soo;Ji, Joon-Suk
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.6 no.2
    • /
    • pp.119-128
    • /
    • 2008
  • Thermal assessment of a new CANDU spent fuel disposal system, which improves the retrievability of the spent fuel and enhances the densification factor compared with the Korean Reference disposal System, is carried out in this study. The canisters for CANDU spent fuels are stored for long term and cooled by natural convection in the proposed disposal system for the retrievability. The steady state thermal analyses for proposed CANDU disposal system are carried out with the ANSYS 10.0 CFX code. The thermal analyses are performed through two steps. At the first step, the sensitivity of the disposal tunnel spacing is analysed. The differences of maximum temperatures by several tunnel spacings are calculated at three points in the disposal tunnel. The result shows that the differences of the temperature at the three points are almost negligible because 99% of the decay heat is removed by natural convection. At the second procedure, 60m tunnel spacing with a ventilation system instead of natural convection is considered. The result is applied to the calculation of the canister surface temperature in disposal tunnel as boundary conditions. Consequently, the average and the maximum surface temperature of disposal canisters are $79.9^{\circ}C$ and $119^{\circ}C$, respectively. The inner maximum temperature of a basket in the disposal canister is calculated as $140.9^{\circ}C$. The maximum temperature of the basket meets the thermal requirement for the CANDU spent fuel cladding.

  • PDF

$Pb(Zn_{1/3}Nb_{2/3})O_3-xPbTiO_3$ 단결정의 온도에 따른 강유전 상전이 고찰

  • 박종성;이중건;홍국선
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2003.05a
    • /
    • pp.21-21
    • /
    • 2003
  • Pb(Zn/sub 1/3/Nb/sub 2/3/)O₃(PZN)은 전형적인 완화형 강유전체로서 급격하게 상전이를 일으키는 것이 아니라 온도에 따라 완만하게 변화하는 물질이다. 완화형 강유전체의 경우, 저온에서는 ㎛ 이상의 거시분역이 존재하고 일반적인 강유전체와 유사한 특성을 가지지만, 온도가 증가하면서 거시분역이 불안정해 지고 크기가 자가져서 수 nm 크기의 미소 극성 영역으로 나뉘는데, 이때 결정구조, 유전율, 유전 손실등의 온도와 주파수에 따른 변화를 관찰하여 강유전 상전이 현상의 특징을 살펴보고자 하였다. 이를 위해 본 연구에서는 융제법에 의해 PZN-xPT 단결정을 성장시킨 후 온도에 따른 결정구조를 변화를 측정하고, 이러한 결정구조의 변화가 강유전 특성에 미치는 영향에 대해 알아보았다. 순수한 PZN은 전형적인 완화형 강유전체의 상전이거동을 나타내었으며, PT의 함량이 증가하면서 점차 일반적인 강유전체로 전이하는 것이 관찰되었다. 그러나 PZN-0.12PT의 경우도 완전한 일반적 강유전체는 아니었으며 완화형거동을 일부 나타내었다. 모든 조성에서 온도가 감소하면서 국부적인 응력의 증가가 관찰되었으며, 응력의 인가 정도는 H 함량에 따라 증가하였다. 이상의 변화는 순수한 PEW에서 나타나는 미소분역들이 온도의 감소와 H 양의 증가에 따라 정전기적 상호작용을 일으키면서 강유전분역으로 성장하기 때문이었으며, Vogel-fulture식에 따른 유전율 최대온도와 측정주파수간의 관계는 분역들간의 상호작용을 됫받침해주었다.

  • PDF

Development of Bayesian Multiple Quantile Regression model and Estimation fo Future Design Rainfall with Increased Temperature (베이지안 다중분위회귀분석모형 개발 및 온도상승에 따른 미래 확률강수량 전망)

  • Uranchimeg, Sumiya;Kim, Jin-Guk;Kwon, Hyun-Han
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.22-22
    • /
    • 2019
  • 최근 전 세계적으로 급증하는 기후변화의 영향으로 인해 강우량 증가에 따른 이상홍수 발생 및 댐 여유고 부족 등 다양한 위험인자가 노출되고 있다. 이러한 예상치 못한 이상홍수는 실제 거주하고 있는 사람들을 위협할 수 있으며, 하천 범람으로 인해 2차 3차 피해가 일어날 가능성이 존재하고 있다. 이에 다양한 자연재해로부터 인명 및 재산 피해를 방지 및 저감하기 위한 목적으로 다양한 수공구조물이 존재하며, 수자원 관리계획 수립의 목적에 따라 다양한 강수량이 활용되고 있다. 특히, 지구온난화에 따른 기후변화 영향을 고려한 연최대 강수량 및 확률강수량 산정이 필요한 시점이며, 온도변화에 따른 증기압 계산식인 Clausius-Clapeyron 관계에 따르면 대기 온도가 $1^{\circ}C$ 상승할 때 대기수분량이 6~7% 증가하여 평균 온도상승에 따라 극치강수량 발생 잠재력이 향상 될 것으로 전망되고 있다. 본 연구에서는 온도상승에 따른 극치강수량의 변화를 베이지안 다중분위회귀분석모형을 통해 산정하여 CORDEX 온도자료 기반의 미래 극치강수량을 전망하였다. 본 연구결과 100년 이상 빈도의 강수량은 온도상승에 따라 급격히 증가하는 추세를 확인하였으며, 2100년까지 온도상승을 고려한 최대 극치강수량은 1500mm를 넘을 가능성을 확인하였다.

  • PDF

Power and Efficiency Optimization through Exergy Analysis of Power Plant (발전 플랜트의 엑서지 해석으로부터 발전량 및 발전효율 최적화)

  • Kim, Deok-Jin;Lee, Jae-Byoung;Kang, Su-Hwan
    • Plant Journal
    • /
    • v.9 no.3
    • /
    • pp.43-47
    • /
    • 2013
  • Even if an expert who has majored energy engineering, it is a difficult concept to understand power output optimization and power efficiency optimization. In this study a diagram applying thermodynamic state value as specific exergy and exergy ratio was developed. Although general peoples who did not major energy engineering can be easily understand the concept of power output optimization and power efficiency through the developed diagram. A represented property that can identify the performance of power plant is the main steam temperature and pressure. At the developed diagram the maximum power output line and maximum power efficiency line are shown according to the temperature and pressure of main steam. Therefore we can identify how much a power plant approach to maximum power output and maximum power efficiency.

  • PDF

Effect of Maximum Aggregate, Porosity, and Temperature on Crack Resistance and Moisture Susceptibility of Porous Asphalt Mixtures (최대입경, 공극률, 온도가 다공성 아스팔트 혼합물의 균열저항성 및 수분민감성에 미치는 영향)

  • Yoo, In-Kyoon;Lee, Su-Hyung;Park, Ki-Soo;Yoon, Kang-Hoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.611-619
    • /
    • 2021
  • Porous asphalt pavement (PAP) has many functions, such as reducing accidents and decreasing noise. On the other hand, vulnerability is inevitable because PAP contains approximately 20% porosity. This study evaluated the effects of the maximum aggregate size (MAS), temperature, and porosity on the PAP durability. The indirect tensile strength measures durability. This study tested the samples that stayed dry and were moisturized by freezing and thawing for mixtures having the same porosity of 20% and MAS of 13mm, 10mm, and 8mm. The same test was performed on a mixture of 20% and 22% voids made of the same material with a MAS of 10mm. As a result, for 20% porosity, significant differences in the changes in MAS and temperature were found. A clear difference was observed between 8mm and 13mm under dry conditions, but there were no other significant differences in the MAS change. Furthermore, there was a clear difference in temperature for the change in porosity and temperature, but the gap in 2% porosity at 20% did not show a clear difference. Therefore, it is necessary to develop a more durable PAP through quantitative evaluations of the factors affecting the PAP durability.

Thermodynamic Optimization of a Organic Rankine Power Cycle (유기 랭킨 사이클 시스템의 열역학적 최적화)

  • Lee, W.Y.;Won, S.H.;Chung, H.S.
    • Solar Energy
    • /
    • v.10 no.3
    • /
    • pp.35-45
    • /
    • 1990
  • An analytical equation to estimate the Rankine power cycle efficiency at maximum power for the given mass flow rates of heating and cooling fluids is derived. The accuracy of the result is shown by comparing the analytical values with those calculated one using detailed thermodynamic data. The results indicate that the thermal efficiency at maximum power depends primarily on the initial temperatures of the heating and cooling fluids, and it also depends on the pinch-temperature differences between the working fluid and the heating and cooling fluids. The efficiency at maximum power provides a measure of the power available in a practical Rankine heat engine.

  • PDF

The Mossbauer Spectra Changes Due to the Jahn-Teller Distortion in Sulphur Spinel $Co_{0.95}Fe_{0.05}Cr_2S_4$ (유화 Spinel $Co_{0.95}Fe_{0.05}Cr_2S_4$에서 Jahn - Teller Distortion에 의한 Mossbauer 공명 흡수선의 변화에 관한 연구)

  • 서정철;이민용;고영복
    • Journal of the Korean Magnetics Society
    • /
    • v.7 no.5
    • /
    • pp.225-231
    • /
    • 1997
  • Sulphur Spinel $Co_{0.95}Fe_{0.05}Cr_2S_4$ has been studied with Mossbauer Spectroscopy between 4.2 K and room temperature. The $Fe^{2+}$ ion in a tetrahedral site is the Jahn-Teller active and the dynamic Jahn-Teller distortion starts below the magnetic ordering temperature. The distortion cause a quadrupole shift to appear which increases with decreasing temperature. The magnetic hyperfine field has a maximum at 100 k and then decreases with decreasing temperature. The magnitude of the interaction ratio R between the electric quadrupole and magnetic dipole interaction increases from 0 near the magnetic ordering temperature to 5.4 at 4.2 K. The optimum values of 0, the polar angle of the magnetic hyperfine field with respect to the principle axis of the electric field gradient (EFG) remains zero and the asymmetry of the EFG n is about 0.25. The simulations of Mossbauer spectra coincidence with the experimental results.

  • PDF

$CaSnO_3$와 소결조제가 첨가된 $BaTiO_3$ 유전체 세라믹의 소결거동 및 유전특성

  • Kim, Tae-Hong;Lee, Jae-Shin;Choy, Tae-Goo
    • ETRI Journal
    • /
    • v.13 no.2
    • /
    • pp.42-53
    • /
    • 1991
  • 고유전율 적충세라믹 커패시터 소재인 $BaTiO_3$ 자기물은 일반적으로 큐리오도인 약 $120^{\circ}C$부근에서 유전율이 최고 약 10,000정도로 증가한 다음 급격히 감소하므로 적절한 이동체를 첨가하여 큐리온도를 상온으로 이동시켜 상온에서 최대 유전율을 이용하여야 한다. 그리고$BaTiO_3$ 자기물은 $1300^{\circ}C$이상의 고온소결시 고가인 Pd전극이 요구된다. 그러나 자기물의 소결온도를 저온화화면 저가의 Ag합금으로 전극재료를 대체할 수 있다. 본 연구에서는 이동제로서 $CaSnO_3$ 를 이용하여 큐리온도를 상온으로 이동시켰다. 또한 소결온도를 저온화하기 위하여 $BaTiO_3$ 세라믹에 여러가지 산화물을 첨가하여 소결현상을 살펴보았다. 실험결과 첨가제를 넣지 않은 경우 소결온도는 $1350^{\circ}C$의 고온이 필요한 반면, $CuO,B_2O_3$$1050^{\circ}C$의 낮은 온도에서도 치밀화와 입도성장이 잘 일어났다. 특히 $B_2$$O_3$ 를 첨가한 경우는 $1250^{\circ}C$이상에서 소결할 때 절연저항이 낮아 유전손실이 큰 문제점을 보였지만, 최대 유전율이 11,000 정도로 높고, 양호한 유전율의 온도변화 특성을 나타내어 우수한 고유전율 소재의 첨가제로 응용될 가능성을 보였다

  • PDF

Estimation of the Economic Coal Feeding Temperature at the Time of Fuel Change to Russian Bituminous Coal during Starting up for CFB Power Plant (발전용 유동층보일러 기동 기간 중 러시아산 유연탄으로의 연료 교체시 경제적인 투입온도 예측)

  • Song, Ha-Kyoung;Kim, Jin-Kuk
    • Plant Journal
    • /
    • v.11 no.3
    • /
    • pp.46-52
    • /
    • 2015
  • 200MWe 순환유동층보일러인 A화력발전소는 정부정책에 의해 국내 무연탄만을 연료로 배정받아 운영되었다. 하지만 무연탄에 대한 민간수요 증가에 따른 정부의 정책변경에 따라 유 무연탄 혼탄을 2000년대 후반부터 시행하고 있다. 하지만 기동시 석탄 투입온도는 여전히 무연탄 전소시의 기준온도인 $600^{\circ}C$에 석탄을 투입하고 있는 실정이라 기동시간 지연의 한 원인으로 작용하고 있고 기동 중 소요되는 경유의 과다소비라는 고질적인 문제점을 안고 있다. 이에 본 연구에서는 A화력에서 사용되는 석탄에 대한 공업분석과 원소분석을 통하여 비교적 휘발분이 많고 반응성이 좋은 러시아산 유연탄(Suek) 연소에 따른 경유에서 석탄으로의 연료교체시 경제적인 시점을 예측하였다. 실험결과 러시아산 유연탄 (Suek) 연소시 투입가능온도는 연소전환율이 90%이상이 되는 연소최대온도($426^{\circ}C$)가 기술적, 경제적으로 가장 적합한 것으로 예상하였다.

  • PDF