• Title/Summary/Keyword: 최대온도

Search Result 3,243, Processing Time 0.026 seconds

Performance Test of Vitiated Air Heater with High Temperature and High Pressure (고온 고압 공기가열기 성능시험)

  • Lee, Jungmin;Na, Jaejeoung;Hong, Yunky;Kim, Jeongwoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • This study presents the performance test results and the analyses of the vitiated air heater with high temperature and high pressure. In the performance test, four test conditions and three rake measurement conditions were implemented. In the results of the performance test, the vitiated air heater met targets of temperature and flow rate, and the performance with maximum temperature of 2000 K and maximum combustion pressure of 40 bar was confirmed. Flow rate of provided methane increased 36% more than what was calculated, and 19.6% difference was displayed between measured temperature and theoretically calculated temperature.

The Effects of Fuel Pellet Eccentricity on Fuel Rod Thermal Performance (핵연료의 편심이 연료봉 열적 성능에 미치는 영향)

  • Suh Young-Keun;Sohn Dong-Seong
    • Nuclear Engineering and Technology
    • /
    • v.20 no.3
    • /
    • pp.189-196
    • /
    • 1988
  • This study investigates the effect of fuel pellet eccentricity on fuel rod thermal performance under the steady state condition. The governing equations in the fuel pellet and the cladding region are set up in 2-dimensional cylindrical coordinate (r, $\theta$) and are solved by finite element method. The angular-dependent heat transfer coefficient in the gap region is used in order to account for the asymmetry of gap width. Material propeties are used as a function of temperature and volumetric heat generation as a function of radial position. The results show the increase of maximum local heat flux at the cladding outer surface and the decrease of maximum and average fuel temperatures due to eccentricity. The former is expected to affect the uncertainties in the minimum DNBR calculation. The latter two are expected to reduce the possibility of fuel melting and the fuel stored energy. Also, the fuel pellet eccentricity introduces asymmetry in fuel pellet temperature and movement of the location of maximum fuel pellet temperature.

  • PDF

The Reduction of Maximum Hydration Temperature in Cement Paste Using Calcium Silicate Hydrates and Glucose (칼슘실리케이트 수화물과 포도당을 이용한 시멘트 페이스트의 최대 수화온도 저감)

  • Moon, Hoon;Kim, Hyeong-Keun;Ryu, Eun-Ji;Jin, Eun-Ji;Chung, Chul-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.3
    • /
    • pp.265-272
    • /
    • 2015
  • In this study, a method to reduce temperature rise due to hydration in mass concrete is investigated. It is to use retarder (glucose) for reducing heat of hydration and to use calcium silicate hydrate (C-S-H) for compensating the retardation effect due to its role as a nucleation seed. For this purpose, the temperature rise of cement paste due to hydration was measured and the effect of using both C-S-H and glucose on setting and 28-day compressive strength of mortar specimens was investigated. According to the experimental results, using C-S-H and glucose caused the reduction in the maximum temperature but accelerated the time to reach the maximum temperature compared to that of retarded cement paste using glucose. In addition, using C-S-H and glucose did not show significant effect on 28-day compressive strength of mortar specimens, indicating that the method shown in this study can be a successful alternative to control maximum temperature rise in mass concrete.

Experimental Study on the Fire Proofing Characteristic of Fire Resistance Panel that it attaches to PSC Airpit-Slab (PSC 풍도슬래브에 부착된 내화패널의 내화특성에 관한 실험연구)

  • Lee, Doo Sung;Bae, Jeong;Choi, Heon;Min, In Gi
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.465-473
    • /
    • 2013
  • In this Study, the performance of precast PSC slabs with fire resistance panel for fire resistance of the tunnel system was evaluated by experimentally. The fire test was performed in fire resistance (electric) furnace according to RABT(Richtlinien fur die Ausstatung und den Betrieb von stra${\beta}$entunneln) time heating temperature curve. The test results showed that the measured temperatures at the t=0 mm depth of PSC slab with precast fire resistance panel during a fire was maximum temperature $367^{\circ}C$, lower than $380^{\circ}C$ (ITA 2004), when damage occurs. Also, at the t=25 mm, the maximum temperature was $239^{\circ}C$, which was lower than the damage temperature of rebar, $250^{\circ}C$. From the results, the use of precast fire resistance panel (t=25 mm) improves fire resistance of PSC structures.

The Study on the Prediction of Temperature Curve by Compartment Fire Experiment (구획화재실험을 통한 온도 변화 예측 기법 연구)

  • Kweon, Oh-Sang
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.44-51
    • /
    • 2014
  • In this study, the Mock-up office space experiments have been performed for the fire behavior analysis of the compartmented space used for the performance-based fire safety design of buildings. Mock-up test was conducted using the compartmented office space dimensions, which are 2.4 m wide, 3.6 m wide, and 2.4 m hight. Test was conducted with the combustible materials such as a desk, a chair, a computer ect. The fire load in the Mock-up office space was $18.74kg/m^2$. As a result, the temperature of the central compartment space to reach $600^{\circ}C$ were 394 to 408 s. The temperature of the corner near the entrance edge to reach $600^{\circ}C$ were 404 to 420 s. At this study, the temperature curve in the compartmented space has been predicted using the temperature data appling the BFD curve. The BFD curve factor based on the fire tests was determined by the maximum temperature of $900^{\circ}C$, 7 min to reach the maximum temperature, and the shape coefficient of 1.5. The initiating fire was rapidly increased to 9 min, and decreased.

An Experimental Study on the Application of Fireproof Panel in Tunnel Duct Slab (터널 풍도슬라브에 사용된 내화패널의 적용성에 관한 실험연구)

  • Woo Jin Choi
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.262-269
    • /
    • 2023
  • Purpose: In this study,fire-resistance test were executed to evaluate the effectiveness of the fireproof panel attached to the PSC slab in tunnel. Method: For the fire resistance test, the RWS curve was applied and the furnace of the KICT was used. Result: As a result of the experiment, the maximum temperature measured on the concrete surface of the PSC slab with the fireproof panel was 321.8℃, which was lower than the damage limit temperature of 380℃ for concrete. Also, at the t=25mm, the maximum temperature was 35.2℃, which was lower than the damage temperature of steel, 250℃. The use of precast fire resistance panel(t=30mm) improves fire resistance of PSC structures. Conclusion: As a result of the test, a reinforcement method for attached a fireproof panel in case of fire in a tunnel or an underground roadway is provided to protect a structure from fire. In the future, it is necessary to perform the static performance test of the slab to which the fireproof panel is attached, and to confirm the adhesion performance of the fireproof panel by performing the pull-off test and the fatigue test.

Development of Shelf-life Prediction Model of Tofu Using Mathematical Quantitative Assessment Model (수학적 정량평가 모델을 이용한 두부의 유통기한 예측 모델의 개발)

  • Shin Il-Shik
    • Food Industry And Nutrition
    • /
    • v.10 no.1
    • /
    • pp.11-16
    • /
    • 2005
  • 식물성 단백질의 주요 공급원이며 우리나라 전통식품 중의 하나인 두부의 유통기한을 정량적으로 예측할 수 있는 수학적 모델을 개발하고자 온도와 초기균수에 따른 두부 부패세균의 성장 실험 결과를 데이터베이스화하여 이를 바탕으로 균의 성장을 정량적으로 평가할 수 있는 수학적 모델을 개발하였다. 근의 증식 지표인 최대증식속도상수(k), 유도기(LT), 세대시간(GT)은 온도에 지배적인 영향을 받았으며, 초기균수에 따른 유의 적 인 차이 는 없었다(p<0.05). 최대증식속도상수와 온도 및 초기균수의 상관관계를 나타내는 수학적 정량평가모델인 square root model을 이 용하여 두부 부패 세균의 성장을 정량적으로 예측할 수 있는 모델$({\surd}{\kappa}=0.016861(T+6.87095))$을 개발하였으며 실험치와 예측치의 상관계수는0.969이었다. 이 예측 정량평가모델로부터 예측한 최대증식속도상수와 두부의 관능적 부패시 점을 반영 한 Gompertz 변형 모델을 이용하여 두부의 유통기한을 예측할 수 있는 모델$(Spoilage-critrion(hr)=\frac{2{\times}Ln2+Ln[(Nmax/No)-1])}{k}$을 개발하였다

  • PDF

Maximum Efficiency Point Tracking Method for Liquid Cooled Inverter (수냉형 인버터의 최대 효율 출력 추적 방법)

  • Kim, Sang-Hyun;Kim, Kwang-Seob;In, Dong-Seok;Lee, Jong-Hak;Park, Young-Min;Won, Seon-Min
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.538-539
    • /
    • 2012
  • 수냉형 인버터는 냉각 시 칠러를 사용하게 되는데 칠러는 입력 냉각수의 온도가 높을수록 열교환 효율이 높아져 소비전력이 감소한다. 하지만 인버터는 입력 냉각수의 온도가 높을수록 손실이 증가하게 되므로 수냉형 인버터는 각각의 출력 부하에 따라 최대 효율 점이 존재한다. 본 논문에서는 각각의 출력 부하에서 냉각수 온도 제어를 통해 수냉형 인버터의 최대 효율점을 추적하는 방법을 제안한다.

  • PDF

Heat Transfer Characteristics on the High Speed Bullet Penetrated a Fuel Tank (고속충격탄의 연료탱크 관통시 열전달 특성)

  • Lee, Seung-Chul;Park, Young-Rok;Jeon, Woo-Chul;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.533-536
    • /
    • 2011
  • 본 연구에서는 차량 연료탱크에 충격탄 관통 시 화재발생 여부를 분석하기 위한 연구의 전단계로서, 충격탄 속도 변화에 따른 연료탱크 내부의 열전달특성을 분석하기 위해 전산유체역학기법을 도입하여 수치해석을 수행한 결과 다음과 같은 결론을 얻었다. 잔류속도 120m/s의 경우, 관통부를 지난 위치에서 최대온도는 약 324.8K를 나타내고 잔류속도 360m/s의 경우, 충격탄이 관통부로 유입되면서 급격하게 증가되어 최고온도 약 382.1K를 나타낸다. 이러한 결과로 미루어 최고 온도가 가솔린 연료의 착화온도보다 높아 화재의 위험성이 있지만 순간적인 온도변화가 심하고 착화시간이 만족되지 않을 것으로 판단된다.

  • PDF

Numerical Study of Evaporation and Ignition of in-line Array Liquid Droplets (액적 배열의 증발과 착화에 관한 수치해석적 연구)

  • 김충익;송기훈
    • Fire Science and Engineering
    • /
    • v.13 no.1
    • /
    • pp.37-47
    • /
    • 1999
  • The spreading fire of very small floating particles after they are ignited is fast and t therefore dangerous. The research on this area has been limited to experiments and global simulations which treat them as dusts or gaseous fuel with certain concentration well m mixed with air. This research attempted micro-scale analysis of ignition of those particles modeling them as liquid droplets. For the beginning, the in-line array of fuel droplets is modeled by two-dimensional, unsteady conservation equations for mass, momentum, energy and species transport in the gas phase and an unsteady energy equation in the liquid phase. They are solved numerically in a generalized non-orthogonal coordinate. The single step chemical reaction with reaction rate controlled by Arrhenius’ law is assumed to a assess chemical reaction numerically. The calculated results show the variation of temperature and the concentration profile with time during evaporation and ignition process. Surrounding oxygen starts to mix with evaporating fuel vapor from the droplet. When the ignition condition is met, the exothermic reactions of the premixed gas initiate a and burn intensely. The maximum temperature position gradually approaches the droplet surface and maximum temperature increases rapidly following the ignition. The fuel and oxygen concentration distributions have minimum points near the peak temperature position. Therefore the moment of ignition seems to have a premixed-flame aspect. After this very short transient period minimum points are observed in the oxygen and fuel d distributions and the diffusion flame is established. The distance between droplets is an important parameter. Starting from far-away apart, when the distance between droplets decreases, the ignition-delay time decreases meaning faster ignition. When they are close and after the ignition, the maximum temperature moves away from the center line of the in-line array. It means that the oxygen at the center line is consumed rapidly and further supply is blocked by the flame. The study helped the understanding of the ignition of d droplet array and opened the possibility of further research.

  • PDF