Comparative Studies on Heating and Cooling Loads' of a Building Varied by Annual Weather Data (연도별 기상데이터를 활용한 건물의 냉.난방부하 특성 비교)

  • Lee, Ji-Hoon;Hwang, Kwang-Il
    • Journal of Navigation and Port Research
    • /
    • v.35 no.3
    • /
    • pp.265-270
    • /
    • 2011
  • The purpose of this study is to compare and analyze the differences of a building's heating and cooling loads depending on the weather variation. Followings are the results. The temperature, humidity and wind speeds of standard year are bigger than those of 2006~2009. The 2006~2009's total horizontal solar irradiance is greater than that of standard year, and the direct solar irradiance of standard year is bigger in winter and vice versa in summer. As results of simulation on heating and cooling loads, it is difficult to find out the bilateral influences between maximum thermal loads and annual's. The equivalent-time operating ratio(EOR) is defined on this study to estimate the differences between year and year, and the EOR of standard year shows low value comparing to 2006~2009 years'.

Automatic Power Supply Time Controller for the Thermal Storage-type Heating Appliances (축열식 난방기기의 심야전력 공급시간 자동제어장치 개발)

  • Kwon S.C.;Han S.H.;Lee H.J.;Park Y.K.;Ko K.J.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07b
    • /
    • pp.921-924
    • /
    • 2003
  • 한전에서는 수요관리의 하나의 방법으로 심야전력요금제도를 운영하고, 심야축열기기를 보급하여 기저부하증대 및 부하율을 개선하기 위한 많은 노력을 기울이고 있다. 최근 유가상승 등의 원인으로 1999년과 2000년에 심야전력 난방기기의 급격한 보급증가로 인한 심야시간대 동계 최대 전력수요가 발생하여 22시 이후 단시간 부하급증으로 일부지역의 배전선로 회선용량부족 및 부하불평형으로 정전을 유발하게 되는 등 많은 어려움이 발생하였다. 본 논문은 심야수요급증으로 인한 대책의 일환으로 축열식 심야난방기기에 대하여 심야전력의 공급시간 자동제어장치를 개발하였다. 축열 잔열량을 측정하여 그 잉여량 만큼의 시간동안 심야전력의 공급을 지연하여 심야전력 공급초기에 집중되는 심야기기의 가동을 억제하여 심야부하를 분산하게 된다. 이로써 축열식 난방기기에 의한 동계 최대 전력수요 발생을 억제하여, 배전선로의 효율적인 운영에 기여할 것으로 기대된다

  • PDF

Development of Power Supply Time Controller during Off-Peak Period for Thermal-storage Electric Heat Radiator (축열식 전기온풍기의 심야전력 공급시간 자동제어장치 개발)

  • Kwon, Seong-Chul;Han, Seung-Ho;Ko, Kee-Joong;Chung, Woo-Yong;Lee, Hak-Ju;Na, ki-Young
    • Proceedings of the KIEE Conference
    • /
    • 2002.07d
    • /
    • pp.2334-2336
    • /
    • 2002
  • 한전에서는 수요관리정책의 일환으로 심야전력요금제도를 운영하고, 심야축열기기를 보급하여 기저부하증대 및 부하율을 개선하여 전력공급 원가절감에 노력하여 왔으나, 최근 유가상승 등의 원인으로 1999년과 2000년에 심야전력 난방기기의 급격한 보급증가로 인한 심야시간대 동계 최대 전력수요가 발생하여 22시 이후 단신간 부하급증으로 일부지역의 배전선로 회선용량부족 및 부하불평형으로 정전을 유발하게 되는 등 많은 어려움이 발생하였다. 본 논문은 심야수요급증으로 인한 대책의 일환으로 축열식 심야난방기기의 하나인 축열식 전기온풍기에 대하여 심야전력의 공급시간 자동제어장치를 개발하였다. 축열 잔열량을 측정하여 그 잉여량 만큼의 시간동안 심야전력의 공급을 지연하여 심야전력 공급초기에 집중되는 심야기기의 가동을 억제하여 심야부하를 분산하게 된다. 이로써 축열식 난방기기에 의한 동계 최대 전력수요 발생을 억제하여, 배전선로의 효율적인 운영에 기여할 것으로 기대된다.

  • PDF

An analysis of the Design heating load calculation in multi-family houses (공동주택 최대난방부하 계산법의 분석)

  • 조동우
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.1
    • /
    • pp.26-32
    • /
    • 2000
  • Design load calculations which depend on the thermal characteristics of the building structure such as the wall, roof, and fenestration provide the basic data for selecting an HVAC system and its equipment. Most of domestic multi-family houses include a high thermal storage layer like massive concrete structure and a floor heating structure. This study is to compare the results of the design heating load between steady state and unsteady state calculation in order to comprehend the thermal storage effect in multi-family houses. The design heating load under the steady state calculation is estimated from 5.4% to 7.8% larger than that under the unsteady state in the typical floor of a multi-family house model. The design heating load considered the safety factors like a orientation and location factor also is 21.4% to 26.5% larger than that by the unsteady state calculation. So, the safety factors for use of the practicing engineer are analyzed as the main factor of a heating plant oversizing.

  • PDF

A Study On heating load analysis and demand side management on winter peak period (동계피크시 계약종별 난방부하분석 및 수요관리 대응방안 연구)

  • Yun, Young-Bum;Kang, Dong-Pil;Lee, Kyung-Jin
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.588-589
    • /
    • 2011
  • `10. 1. 13일 한파지속에 따른 16년 만에 동계피크가 발생 하였으며, '11. 1. 17일 73,137MW로 2년 년속 동계피크 경신으로 우리나라도 이젠 동계피크 발생국가에 해당된다고 볼 수 있다. 이는 경기회복에 따른 산업용전력의 증가가 동계피크 발생을 견인하였지만 타 에너지원에 비해 전기요금이 저렴하기 때문에 난방연료원이 가스나 가름에서 전기로 지속적으로 전환된 것이 가장 큰 원인이라고 보여 진다. 효과적인 전력수요관리를 위해서는 계약종별별로 부하량과 난방부하량을 측정해서 분석하는 것이 무엇보다 중요하다 하겠다. 그렇지만 실시간으로 계약종별로 부하량 자료를 얻을 수 있는 것은 현재 고압고객의 AMR계량시스템자료가 있으나 이는 고압전체의 85% 대 수준의 자료를 읽어올 뿐 전제 부하를 대변할 수 없으므로 발전단 부하를 계약종별로 적절하게 안분하는 것이 필요하다고 볼 수 있다. 8760시간대별 부하분석을 위해서는 발전단 부하와 배전단부하를 근간으로 고압고객의 원격자동검침(AMR) 자료를 활용하여 최대피크기여도를 분석하여 부하분석을 수행하였다.

  • PDF

Heat Consumption Pattern Analysis by the Component Ratio of District Heating Users (지역난방 사용자 구성비에 따른 열소비 패턴 분석)

  • Lee, Hoon;Lee, Min-Kyun;Kim, Lae Hyun
    • Journal of Energy Engineering
    • /
    • v.22 no.2
    • /
    • pp.211-225
    • /
    • 2013
  • To run an optimal operation of Integrated energy supply facilities, we need to analyze heat consumption patterns of District heating users and derive optimum and maximum load ratio of heat production facilities unit. This study selects three District heat production facilities. It also classifies District heating users into residential apartment buildings and eight non-residential buildings and analyzes heat consumption results for an year. Finally it carries out the analysis of how the ratio change of each type affects maximum load ratio, facility utilization ratio, heat supply range. According to this study, three different District heat facilities of residential apartment building show similar daily and annual heat consumption patterns. Annual average load ratio, maximum load ratio and annual heat demand increase as outdoor temperatures decrease. Non-residential buildings in urban District focused on apartment buildings display similar by the daily and annual heat consumption patterns. Yet their daily and annual maximum load ratio differ according to outdoor temperature, District, building types and their composition ratio. In the case of urban District focused on apartment buildings reach optimum and maximum load ratio when apartment buildings reaches 60-70% of the total. At that point heat supply range becomes maximized and the most economic efficiency is obtained.

Analysis of the Outdoor Design Conditions for Greenhouse Heating and Cooling Systems in Korea (온실의 냉난방시스템 설계용 외부기상조건 분석)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.25 no.4
    • /
    • pp.308-319
    • /
    • 2016
  • In order to set the outdoor weather conditions to be applied to the design standard of the greenhouse heating and cooling system, outdoor air temperature and heating degree-hour for heating design, dry bulb temperature, wet bulb temperature and solar irradiance for cooling design were analyzed and presented. For every region in Korea, we used thirty years from 1981 to 2010 hourly weather data for analysis, which is the current standard of climatological normal provided by KMA. Since the use of standard weather data is limited, design weather conditions were obtained using the entire weather data for 30 years, and the average value of the entire data period was presented as a design standard. The design weather data with exceedance probability of 1, 2.5, and 5% were analyzed by the TAC method, and we presented the distribution map with exceedance probability of 1% for heating and 2.5% for cooling which are recommended by design standards. The changes of maximum heating load, seasonal heating load and maximum cooling load were examined by regions, exceedance probabilities, and setpoint temperatures. The proposed outdoor design conditions can be used not only directly for the greenhouse heating and cooling design, but also for the reinforcement of heating and cooling facilities and the establishment of energy saving measures. Recently, due to the climate change, sweltering heat in summer and abnormal temperature in winter are occurring frequently, so we need to analyze weather data periodically and revise the design standard at least every 10 years cycle.

가스냉방시장 및 경제성

  • 한정옥
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.33 no.3
    • /
    • pp.33-36
    • /
    • 2004
  • 냉방에너지에 대한 분석과 전기냉방에 대한 가스냉방의 경제성 및 향후 가스냉방의 보급전망을 기술하였다. 가스냉방 부하 가스냉방은 80년대 중반부터 하절기 최대 전력수요 억제의 일환으로 보급이 본격화되기 시작했으며 가스 흡수식 냉방기 및 냉온수기의 공급으로 대규모 건축물의 냉난방에 대한 개념이 서서히 바뀌기 시작하였다. 92년 7월 “건축물의 냉방설비에 대한 설치 및 설계기준” 이 제정, 시행됨에 따라 일정규모 이상의 건축물에 중앙집중식 냉방설비 설치시 주간 최대 냉방부하의 60% 이상을 가스냉방 또는 축냉식으로 설치 의무화됨으로써 냉방은 물론 난방까지 겸하는 흡수식 냉온수기의 보급이 크게 증가하고 있다.(중략)

  • PDF

Experimental Study on the Infiltration Loss in Plastic Greenhouses Equipped with Thermal Curtains (보온커튼을 설치한 플라스틱 온실의 틈새환기전열량 실측조사)

  • Nam, Sang-Woon;Shin, Hyun-Ho
    • Journal of Bio-Environment Control
    • /
    • v.24 no.2
    • /
    • pp.100-105
    • /
    • 2015
  • The calculation method of infiltration loss in greenhouse has different ideas in each design standard, so there is a big difference in each method according to the size of greenhouses, it is necessary to establish a more accurate method that can be applied to the domestic. In order to provide basic data for the formulation of the calculation method of greenhouse heating load, we measured the infiltration rates using the tracer gas method in plastic greenhouses equipped with various thermal curtains. And then the calculation methods of infiltration loss in greenhouses were reviewed. Infiltration rates of the multi-span and single-span greenhouses were measured in the range of $0.042{\sim}0.245h^{-1}$ and $0.056{\sim}0.336h^{-1}$ respectively, single-span greenhouses appeared to be slightly larger. Infiltration rate of the greenhouse has been shown to significantly decrease depending on the number of thermal curtain layers without separation of single-span and multi-span. As the temperature differences between indoor and outdoor increase, the infiltration rates tended to increase. In the range of low wind speed during the experiments, changes of infiltration rate according to the outdoor wind speed could not find a consistent trend. Infiltration rates for the greenhouse heating design need to present the values at the appropriate temperature difference between indoor and outdoor. The change in the infiltration rate according to the wind speed does not need to be considered because the maximum heating load is calculated at a low wind speed range. However the correction factors to increase slightly the maximum heating load including the overall heat transfer coefficient should be applied at the strong wind regions. After reviewing the calculation method of infiltration loss, a method of using the infiltration heat transfer coefficient and the greenhouse covering area was found to have a problem, a method of using the infiltration rate and the greenhouse volume was determined to be reasonable.

외단열 건물의 열부하계산법

  • 조민관
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.32 no.2
    • /
    • pp.28-39
    • /
    • 2003
  • 1998년 4월 일본 공기조화.위생공학회 북해도지부 설비기술연구회에서는 실무레벨의 "외단열건물의 열부하계산법"을 위한 소위원회가 발족되었으며, 1999년 11월에 연구보고서가 완성되었다. 이에, 일본 학회에서는 건축설비기술자협회 북해도 지부와 공동으로 실무자를 대상으로 세미나를 2000년8월에 개최하였다. 본 내용은 위원회보고서와 세미나에 서 거론된 "외단열건물의 열부하특성과 계산법의 요점"을 제시하고 이에 근거한 최대부하의 합리적인 설계와 불가분의 관계가 있는 "외단열건물을 위한 난방과 냉방을 통일한 열부하계산법의 개념"을 소개함과 동시에 "실무자의 과제와 금후의 전망"에 대하여 언급하고자 한다.