Purpose : We'd like to determine the incidence of congenital heart disease and arrhythmia in elementary school children in Busan, and to provide adequate prevention and treatment. Methods : A total of 23,802(male 12,909, female 10,893) 1st grade elementary school children living in Busan were studied. All children were 7-8 years old. We obtained their medical history by questionnaire and checked elecrocardiography(ECG). Subsequent screening tests including a 2nd ECG, chest X-ray, phonocardiogram and CBC for the students who had abnormal findings at the first screening test. The third screening test was done for students who had cardiac murmurs or abnormal ECG findings in the second screening test by echocardiogram, treadmill test and 24-hour Holter monitoring. Results : Among 23,802 children participants, 605(2.54%) had abnormal ECG findings at the first screening test. Q wave abnormality(0.58%) was observed most frequently, and complete right bundle branch block(RBBB)(0.26%), sinus tachycardia(0.24%), right axis deviation(0.22%) and ventricular premature contraction(VPC)(0.21%) followed in order. Four hundred and twenty four children participated in the second ECG screening test. Two hundred and two children(47.6%) had an abnormality such as sinus tachycardia(18.8%), VPC(17.8%), or complete RBBB(17.3%). After completing the third examination including echocardiogram, we couldn't find the students with ventricular tachycardia (VT) or SVT at the third arrhythmia screening test. Conclusion : A high incidence of arrhythmia was found in the 1st grade elementary school children in Busan despite their healthy appearances, although fatal heart diseases were not noted. Early diagnosis, adequate preventative measures and treatment will prevent and decrease the frequency of emergent situations like syncope and sudden death.
Kim, Jung-Min;Kim, Dong-Huan;Hayashi, Taro;Ishida, Yuji;Maeda, Mika;Sakura, Tatsuya
Journal of radiological science and technology
/
v.15
no.1
/
pp.65-78
/
1992
Routine chest radiography is generally imaged by high voltage technique but some radiological technologists use low voltage for imaging. High voltage is usually said between $120\;kV{\sim}140\;kV$. Some RTs like using heavy filtration but others seldom like using it. However which is better for use calcium tungustate film screen system or ortho system and high contrast film or wide latitude c-type film for the exculusive use of chest radiography. We could not make a decision which is ideal method for use. In my opinion any method is not always exellent for chest radiography. In my experiments that I had at Kaken hospital in Japan last year I expect to keep the balance between image quality and diagnostic range and to reduce radiation dose for patients. My experiments are as follows. 1. We have looked into system characteristics(speed and contrast) in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems(BX3+CRONEX4, SRO750+MGH, SRO750+MGL). 2. We have looked into skin dose and film dose with same D=1.8 lung field density in accordance with kVp($80{\sim}140$) and added filter($no{\sim}1/16\;VL$) in three screen film systems. 3. We have compared with the evaluation between correlation of physical image quality(MTF) and optical diagnostic capability. Result are follows. 1. Speed of BX3+CRONEX4 became higher in accodance with kVp and thickness of filter but speed of ortho system was not as like regular system. Thicker filter diminished the speed over 100 kV range in SRO750+MGL. In case of SRO750+MGH speed of 1/16VL filter was looked into lower than speed of 1/4VL filter. Sensitivity of ortho system depends on tube voltage and added filter. 2. Skin dose has been detected $225\;{\mu}Gy{\sim}66\;{\mu}Gy$ in BX3+CRONEX4 from 80 kV, no filter to 140 kV, 1/16VL filter. SRO750+MGH could reduce the patient dose $1/2{\sim}1/3$ level in comparison to that of BX3+CRONEX4. 3. The higher kV was the worse MTF became the thicker filter was the worse MTF became too. MTF of BX3+CRONEX4 was detected better than MTF of SRO750+MGH but SRO750+MGH's optical detectability of small lesion in lung field came out better than that of BX3+CRONEX4. Conclusion Recently routine chest radiography is generally imaged by high voltage but it seems to be there are some questions in using of film screen combination. In high voltage chest radiography the subject contrast will come down that means latitude become wider. In this case if we select the low contrast film screen system(C or L type) the film contrast will fall down extremly and detectability of small lesion will be deteriorated. Wide latitude C, L type film has a merit of high detectability on mediastinum. Furthermore high contrast film screen system has the advantage to keep the high contrast in low density region as like mediastinum and heart shadow. Therefore in low subject contrast high voltage chest radiography we would rather choose the high contrast film screen system(H type) I think. From a view point of patient dose detectability of mediastinum and lung field. The optimum technical facter was found out 120 kV, 1/16VL filter : BX3+CRONEX4, 140 kV, 1/4VL filter : SRO750+MGH, 100 kV, 1/4VL filter : SRO750+MGL.
The purpose of this study is finding optimum contrast medium quantity during abdominal CT using dual energy technique. The study subjects are 30 patients who had received general single energy abdominal CT and received double energy technique follow-up abdominal CT. dual energy technique abdominal CT images were obtained after setting contrast medium quantities at 30%, 40%, 50%, 60% and 70% of contrast medium quantity at the time of single energy technique. Then the contrast enhancement (Hounsfield Unit; HU) was estimated by setting-up the regions of interest at aorta, inferior vena cava, hepatic portal vein and hepatic parenchymal. The obtained values were compared to the values of the same parts measured during single energy technique abdominal CT. The results of the study were as following. The 60% set up group had HU in aorta : $210.80{\pm}13.609$, IVC : $190.40{\pm}25.215$, hepatic portal vein : $198.40{\pm}21.232$ and hepatic parenchymal : $119.20{\pm}7.98$, The single energy abdomianl CT images had HU in aorta : $205.40{\pm}16.426$, IVC : $188.20{\pm}21.476$, hepatic portal vein : $195.40{\pm}22.744$ and hepatic parenchymal : $121.00{\pm}6.595$. Therefore, it is possible to obtain contrast enhancement by dual energy technique abdominal CT similar to the same by single energy technique abdominal CT by setting-up the quantity of contrast medium at 60% of contrast medium at the time of single energy technique abdominal CT. Based on the result of this study, it is possible to decrease existing quantity of contrast medium by _% and the injection velocity can be also decreased. Accordingly, it is believed that the result of study would be quite useful for patients who have renal function disorder, weak vein or side effect of contrast medium in the past.
Park, Jae Jin;Ko, Seong Jin;Kang, Se Sik;Kim, Chang Soo;Kim, Jung Hoon;Kim, Dong Hyun
Journal of the Korean Society of Radiology
/
v.7
no.5
/
pp.353-358
/
2013
Recently, the Percutaneous Coronary Intervention has become a main treatment for treating Coronary because of increase of Circulatory Disease. Because of this reason, the increase of intervention using radiation causes the radiation exposure to workers. Therefore, the latent radiation injury can be increased. Thus, this study/experiment measured around under knee whether using radiation collimator shielding or not. We measured the exposure does by the experiment methods which are using 60kV, 200mA, and 10ms of Automatic exposure conditions and using the major method of the Cinefluography of Coronary in our hospital. As the result of right coronary artery test cases, LAO $30^{\circ}$ when the curtains if you use lead 98.4%, $Cranial30^{\circ}$ 98.3% have a protective effect of the radiation. left circumflex coronary artery test cases, Caudal $30^{\circ}$ if the shielding effect of 90.2%, Caudal $30^{\circ}LAO$$30^{\circ}$ 88.7% have a protective effect of the radiation. left anterior descending artery test cases, Cranial $30^{\circ}$ 98.3%, Cranial $30^{\circ}RAO$$30^{\circ}$ 80.3%, Cranial $30^{\circ}$LAO $30^{\circ}$ 98% of the radiation has a protective effect. OS(Spider view) in the case of test Caudal $40^{\circ}LAO$$40^{\circ}$ 71.2% appeared to have the effect of radiation shielding. For these reasons, radiation workers need to be aware on taking care of their radiation exposure by using the radiation collimator shielding even though it is uncomfortable for them.
Helical Tomotherapy is an innovative means of delivering intensity modulated radiation therapy (IMRT) using a device that merges features of a linear accelerator and helical computed tomography (CT) scanner. Hereat, during helical tomotherapy process, megavoltage computed tomography (MVCT) image are usually used for guiding the precise set-up of patient before/after treatment delivery. But which would certainly increase the total dose for patients, this study was to investigate the imaging dose of MVCT using the cylindrical "Cheese" phantom on a tomotherapy machine. A set of cylindrical "Cheese" phantom was adopted for scanning with respectively pitch value (1, 2, 3 mm) with same number slice (10 slice), same length (approximately 9 cm) and phantom set-ups on the couch of tomotherapy system. The average MVCT imaging dose were measured using A1SL ion chamber inserted in the phantom with preset geometry. The MVCT scanning average dose for the cylindrical "Cheese" phantom was 2.24 cGy, 1.02 cGy, 0.81 cGy during respectively pitch value (pitch 1, 2, 3 mm) with same number slice (10 slice), and same length's average dose was 2.47 cGy, 1.28 cGy, 0.88 cGy respectively (pitch 1, 2, 3 mm). Two major parameters, the assigned pitch numbers and scanning length, where the most important impacts to the dose variation. The MVCT dose was inversely proportional to the CT pitch value. The results may provide a reliable guidance for proper planning design of the scanning region, which is valuable to help minimize the extra dose to patient. Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines.
The psychological anxiety of radiologists, as well as the patients, is growing with the increasing use of CT contrast agent side effects and the process of extravasation. In this study, a satisfaction survey was conducted regarding the wireless signal device after CT examination in patients and radiologists by employing a wireless signal device during a contrast-enhanced CT examination in order to determine its usefulness to the relieve psychological anxiety, such as anxiety and fear, of patients and radiologists when using contrast agents. The use of a wireless signal device was also intended to help radiologists in dealing with the side effects of contrast agents that may occur during a CT examination and preventing extravasation. Patients aged 20 years or older, who visited the C university hospital in Jeonnam province for 4 months from August to November in 2017, were surveyed. A total number of 90 patients (57 males and 33 females),who agreed to the study after CT examination, were included in the questionnaire survey. Meanwhile, 15 radiologists, who were working at a CT room and had an experience in using a wireless signal device, were surveyed. Patient satisfaction was $6.01{\pm}0.88$ before the use of a wireless signal device and $8.20{\pm}1.06$ after use, thereby showing an increased satisfaction after its use. Radiologist satisfaction was $8.46{\pm}1.06$ after use, thereby not showing a big difference from the mean patient satisfaction. The satisfaction was high at over 8 points in both groups. The contribution to psychological stability with the use of a wireless signal device was $8.98{\pm}0.65$ in patients with prior experience of side effects and $8.00{\pm}1.21$ in patients without prior experience of side effects. In conclusion, it is considered to improve satisfaction with the examination by helping the radiologists in taking immediate action with calling via the wireless signal device and providing the patients and radiologists with psychological stability by reducing their anxiety.
Currently, the highest cancer death rate in Korea is lung cancer, which is a typical cancer that is difficult to detect early. Low-dose chest CT is being used for early detection, which has a greater lung cancer diagnosis rate of about three times than regular chest x-ray images. However, low-dose chest CT not only significantly reduces image resolution but also has a weak signal and is sensitive to noise. Also, air filled lungs are low-density organs and the presence of noise can significantly affect early diagnosis of cancer. This study used Visual C++ to set a circle inside a large circle with a density of 2.0, with a density of 1.0, which is the density of water, in which five small circle of mathematics have different densities. Gaussian noise was generated by 1%, 2%, 3%, and 4% respectively to determine the effect of noise on the mean value, the standard deviation value, and the relative noise ratio(SNR). In areas where the density difference between the large and small circles was greatest in the event of 1 % noise, the SNR in the area with the greatest variation in noise was 4.669, and in areas with the lowest density difference, the SNR was 1.183. In addition, the SNR values can be seen to be high if the same results are obtained for both positive and negative densities. Quality was also clearly visible when the density difference was large, and if the noise level was increased, the SNR was reduced to significantly affect the noise. Low-density organs or organs in areas of similar density to cancers, will have significant noise effects, and the effects of density differences on the probability of noise will affect diagnosis.
Kim, Doo-Wan;Kim, Young-Hwa;Min, Ye-Jin;Yu, Dong-Jo;Jeong, Yong-Dae
Journal of the Korea Academia-Industrial cooperation Society
/
v.18
no.11
/
pp.282-289
/
2017
Animal Welfare is spreading throughout the world, but remains weak in Korean swine farms. Therefore, the aim of this study was to identify the effect of floor type and hanging type environmental enrichment on the behavior of growing pigs under the traditional feeding environment. A total of 45 crossbred pigs (Yorkshire${\times}$Landrace${\times}$Duroc; average weight, $33.35{\pm}5.5kg$) were assigned into three treatments consisting of control, hanging type(T1) and floor type(T2) with three replicates in semi-slurry pen. The hanging enrichment was suspended at shoulder height of the pigs, and the floor enrichment was fixed in the center of the pens. Growth and cortisol were estimated at the end of the experimental period. Behaviour patterns were analyzed on the first and eighth days after starting the experiment. Growth was not differed among control and treatments. However, cortisol was decreased in T2 compared to control(25.28 vs. 46.75 ng/mL; p<0.05). On the first day, movement and aggression were lower in both treatments than in control(p<0.01). On the eighth day, time and frequency of playing action were increased in T2 compared to T1(p<0.01) and both treatment groups showed more active behaviour than control(p<0.01). These results suggested that the enrichment may meet the natural action requirement of pigs. Therefore, our data can be utilized as basic information for welfare with environmental enrichments in farm animals.
Journal of the Korea Academia-Industrial cooperation Society
/
v.15
no.12
/
pp.6973-6979
/
2014
To mitigate global warming and climate change, many countries are investing massively on the development of CCS technology, which is assumed to be the key technology to reduce $CO_2$ emissions. CCS technology is comprised of the capture, transport, and storage processes. During the capture process, impurities other than $CO_2$ are inevitably flowed into the $CO_2$ stream. In the present study, corrosion characteristics of a phosphate coated tube for $CO_2$ transportation was investigated with a $CO_2$ stream composed of $CO_2$, $H_2O$, $SO_2$, and $NO_2$. The test specimen was a phosphate coated steel tube, which was filled with $CO_2$ stream with the impurities mentioned above. SEM-EDS analysis is conducted to investigate the corrosion behavior. The results showed that although the H2O concentration did not exceed the solubility limit, corrosion occurred in the specimen, which has an inflow of $SO_2$ or $NO_2$. This suggests that the $SO_2$, $NO_2$ and $H_2O$ concentration should be strictly controlled. These results suggest that the $SO_2$ and $NO_2$ concentration should be controlled below 175ppm and 65ppm, respectively.
Introduction: Unexpected serious and lethal drug interactions can be occurred by polypharmacy for treatment-resistant psychiatric disorders. We report a case who has suspected upper gastrointestinal bleeding after the combination of clozapine and buspirone. Case : A 69-year-old woman with DSM-IV schizophrenia who was admitted to our hospital had no previous medical problems. Findings on physical exam, laboratory values, EEG, and a magnetic reso-nance imaging scans were no abnormality, except for slightly low level of hemoglobin at admission. Because of aggravating anxiety symptom, a trial of buspirone was begun from 15mg, in addition to olanzapine 30mg. And then olanzapine was switched to clozapine due to her treatment-refractory his-tory and poor response on this admission. Moreover, At the admission 11 weeks later, after 4 weeks of starting buspirone and clozapine, she was placed on a regimen of clozapine 300mg and buspirone 60mg. At this point, she started to complaint nonspecific abdominal pain for 4 days and then hematemesis, melena and hypotension were developed suddenly with negative findings in gastroduodenoscopy. After stopping all medication, the suspected upper gastrointestinal bleeding was subsided. After the regimen was switched back to clozapine only, psychotic symptoms were improved without the recurrence of the adverse events. Conclusion : We concluded that the upper gastrointestinal bleeding in this case was attributed to the drug interaction with clozapine and buspirone, although the definite mechanism is not clear. The clini-cians should be very cautious to prescribe the combination of clozapine and buspirone due to a possible lethal adverse effect.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.