• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.036 seconds

Development of $^{192}Ir$ Small-Focal Source for Non-Destructive Testing Application by Using Enriched Target Material (고농축 표적을 이용한 비파괴검사용 $^{192}Ir$ 미세초점선원 개발)

  • Son, K.J;Hong, S.B.;Jang, K.D.;Han, H.S.;Park, U.J.;Lee, J.S.;Kim, D.H.;Han, K.D.;Park, C.D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.1
    • /
    • pp.31-37
    • /
    • 2007
  • A $^{192}Ir$ small-focal source has been developed by using the HANARO reactor and the radioisotope production facility at the Korea Atomic Energy Research Institute (KAERI). The small-focal source with the dimension of 0.5 mm in diameter and 0.5 mm in length was fabricated as an aluminum-encapsulated form by a specially designed pressing equipment. For the estimation of the radioactivity, neutron self-shielding and ${\gamma}-ray$ self-absorption effects on the measured activity was considered. From this estimation, it is realized that $^{192}Ir$ small-focal sources over 3 Ci activities can be produced from the HANARO. Field performance tests were performed by using a conventional source and the developed source to take images of a computer CPU and a piece of a carbon steel. The small-focal source showed better penetration sensitivity and geometrical sharpness than the conventional source does. It is concluded from the tests that the focal dimension of this source is small enough to maximize geometrical sharpness in the image taking for the close proximity shots, pipeline crawler applications and contact radiography.

Miniaturized Ground-Detection Sensor using a Geomagnetic Sensor for an Air-burst Munition Fuze (공중폭발탄용 신관에 적용 가능한 초소형 지자기 지면감지 센서)

  • LEE, HanJin
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.54 no.5
    • /
    • pp.97-105
    • /
    • 2017
  • An air-burst munition is limited in space, so there is a limit on the size of the fuze and the amount of ammunition. In order to increase a firepower to a target with limited ammunition, it is necessary to concentrate the firepower on the ground instead of the omnidirectional explosion after flying to the target. This paper explores the design and verification of a ground-detection sensor that detects the direction of the ground and determines the flight-distance of an air-burst munition using a single axis geomagnetic sensor. Prior to the design of the ground detection sensor, a geomagnetic sensor model mounted on the spinning air-burst munition is analyzed and a ground-detection algorithm by simplifying this model is designed. A high speed rotating device to simulate a rotation environment is designed and a geomagnetic sensor and a remote-recording system are fabricated to obtain geomagnetic data. The ground detection algorithm is verified by post-processing the acquired geomagnetic data. Taking miniaturization and low-power into consideration, the ground detection sensor is implemented with analog devices and the processor. The output signal of the ground detection sensor rotating at an arbitrary rotation speed of 200 Hz is connected to the LED (Light Emitting Diode) in the high speed rotating device and the ground detection sensor is verified using a high-speed camera.

Borehole Image Processing System(BIPS)를 이용한 사면 안정성 해석

  • Yu, Byeong-Ok;Kim, Byeong-Seop
    • Journal of the Korean Geophysical Society
    • /
    • v.5 no.2
    • /
    • pp.111-129
    • /
    • 2002
  • Generally, investigation methods of cut slope are conucted only geological surface survey to gain engineering geological data of cut slopes. These methods have many problems such as limitations of investigation for a special area. So geophysical investigations such as geotomography, seismic and electrical resistivity methods have been used to search for failure surface in potential failure slopes or failed slopes. But investigation method using the borehole camera is recently a used method and it is thought that this method is more reliable method than other investigation methods because of being able to see by the eyes. Therefore, this paper was conducted investigations of borings and BIPS(Borehole Image Processing System) to search for potential sliding surfaces and was applied to obtain information of discontinuity on failed and potential failure slope in highway. As the results of BIPS, we could decide potential sliding surface in the slope, conducted to check slope stability and decided slope stability measures.

  • PDF

A Comparative Study of Facemask Therapy with Two Types of Bonded Expander (Bonded expander 형태에 따른 facemask의 치료 효과 비교연구)

  • Lee, Eunha;Park, Kitae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.4
    • /
    • pp.298-305
    • /
    • 2014
  • The purpose of this study is to evaluate the effects of facemask therapy in patients with Class III malocclusion with two types of bonded expanders covering different numbers of anchored teeth and to compare the anchorage value of two types of bonded expander. Eighteen subjects with Class III malocclusion in early mixed dentition were included in this study, and subjects were divided into two groups based on the number of teeth covered by bonded expander: group 1 (splinting four teeth on each side, 9 subjects) and group 2 (splinting three teeth on each side, 9 subjects). Lateral cephalograms were obtained and assessed before (T1) and after (T2) the treatment. The facemask therapy showed skeletal effects including anterior movement of maxilla and backward rotation of mandible in both groups, with no significant differences between groups. Mesial movement of maxillary molars which indicates anchorage loss of the bonded expander was found in both groups, but significantly larger mesial movement was found in group 2 than in group 1. In conclusion, the value of anchorage was different according to the number of teeth covered by bonded expander as an intraoral anchorage of facemask, but there were no significant differences in skeletal effects.

The Imbalance Compensation in CMG ('제어모멘트자이로'의 질량불균형 보정)

  • Lee, Jong-Kuk;Song, Tae-Seong;Kang, Jeong-Min;Song, Deok-Ki;Kwon, Jun-Beom;Seo, Joong-Bo;Oh, Hwa-Suk;Cheon, Dong-Ik;Hong, Young-Gon;Lee, Jun-Yong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.48 no.11
    • /
    • pp.861-871
    • /
    • 2020
  • Raising the speed of the momentum wheel in the CMG increases the unintended force and torque caused by mass imbalance. This unintended force and torque should be minimized to get the better quality of satellite SAR image because they lead to the vibration of the output image. This paper shows the works on compensating the static imbalance and couple mass imbalance in the CMG wheel. First, the force and torque at the center of mass generated by the mass imbalance were predicted through M&S analysis. Second, the force and torque were estimated similarly through the M&S analysis when the measurement point was moved from the rotation center. Third, the measurement configuration for the force and torque by the mass imbalance was described. Fourth, the change of the force and torque by adding the specified mass to the momentum wheel was observed after comparing the measurements with the results of the M&S. And finally, the effect of the compensation was analyzed by comparing the force and torque before and after the correction while 24Nm class CMG was running in the standby mode.

Studies of Automatic Dental Cavity Detection System as an Auxiliary Tool for Diagnosis of Dental Caries in Digital X-ray Image (디지털 X-선 영상을 통한 치아우식증 진단 보조 시스템으로써 치아 와동 자동 검출 프로그램 연구)

  • Huh, Jangyong;Nam, Haewon;Kim, Juhae;Park, Jiman;Shin, Sukyoung;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.1
    • /
    • pp.52-58
    • /
    • 2015
  • The automated dental cavity detection program for a new concept intra-oral dental x-ray imaging device, an auxiliary diagnosis system, which is able to assist a dentist to identify dental caries in an early stage and to make an accurate diagnosis, was to be developed. The primary theory of the automatic dental cavity detection program is divided into two algorithms; one is an image segmentation skill to discriminate between a dental cavity and a normal tooth and the other is a computational method to analyze feature of an tooth image and take an advantage of it for detection of dental cavities. In the present study, it is, first, evaluated how accurately the DRLSE (Direct Regularized Level Set Evolution) method extracts demarcation surrounding the dental cavity. In order to evaluate the ability of the developed algorithm to automatically detect dental cavities, 7 tooth phantoms from incisor to molar were fabricated which contained a various form of cavities. Then, dental cavities in the tooth phantom images were analyzed with the developed algorithm. Except for two cavities whose contours were identified partially, the contours of 12 cavities were correctly discriminated by the automated dental caries detection program, which, consequently, proved the practical feasibility of the automatic dental lesion detection algorithm. However, an efficient and enhanced algorithm is required for its application to the actual dental diagnosis since shapes or conditions of the dental caries are different between individuals and complicated. In the future, the automatic dental cavity detection system will be improved adding pattern recognition or machine learning based algorithm which can deal with information of tooth status.

Assessment of the Effective Dose to the Human Body and Estimation of Lifetime Attributable Risk by CT Examination (CT 검사별 노출되는 유효선량과 생애 암 귀속 위험도 평가)

  • Cho, Yong In;Kim, Jung Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.2
    • /
    • pp.169-178
    • /
    • 2020
  • The number of CT scans is increasing every year due to the improvement of the medical standards of the public, and thus the annual dose of medical radiation is also increasing. In this study, we evaluated the effective dose of the human body exposed to CT scans and estimated LAR. First, five region were selected from the CT diagnostic reference level guideline, and the effective dose of human body exposed to each examination was evaluated by clinical CT device. Second, the human organs and effective dose were calculated using the ALARA-CT program under the same conditions. Third, lifetime attributable risk (LAR) estimated by the effective dose exposed through the previous CT scan was estimated. As a result, the most effective dose was 21.18 mSv during the abdomen 4 phase scan, and the dose level was below DRL for all other tests except for the abdominal examination. As a result of evaluating effective dose using a dose calculation program under the same conditions, the results showed about 1.1 to 1.9 times higher results for each examination. In the case of organ dose, the closer the organ to the scan site, the higher the scattering ray. The lifetime attributable risk to CT radiation dose in adults was gradually decreased with age, and the results were somewhat different according to gender.

A Study on Perception by Examinees of the Dental Hospital Institutions about Exposure to Radioactivity (치과병원에 내원한 환자의 방사선피폭 인지도에 관한 연구)

  • Yeo, Jin-Dong;Ko, In-ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.233-243
    • /
    • 2018
  • The purpose of this study was to investigate factors of perception by inpatients of the Dental Hospital institutions about exposure to radioactivity at the time of radioactive examination, providing basic information for making educational materials aimed to change their perception. Most of those patients, 65.5.0% responded that CT was a type of radioactive examination bringing highest exposure to radiosensitivity. Most of the subjects, 56.1% said that a body part most vulnerable to exposure to radiosensitivity was the genital gland at the time of radiosensitivity examination. And most of the participants, or 26.3% responded that they obtained information about radiation from TVs or newspapers. Among the surveyed patients, men were higher in scores for factors of the perception of radiation such as recognition of radiation, harmfulness of radiation, psychological state at the time of radioactive examination, prevention of exposure to radioactivity and necessity of radiation that women were, with statistically significant differences between the two groups. These findings suggest that it is urgently needed to develop an education program which helps patients better perceive exposure to radioactivity and that radiologists should be very careful to reduce the does of that exposure. If patients better perceive radiation, they would be less anxious and less exposed to radioactivity when receiving the radioactive examination.

A Study on Data Acquisition in the Invisible Zone of UAV through LTE Remote Control (LTE 원격관제를 통한 UAV의 비가시권 데이터 취득방안)

  • Jeong, HoHyun;Lee, Jaehee;Park, Seongjin
    • Korean Journal of Remote Sensing
    • /
    • v.35 no.6_1
    • /
    • pp.987-997
    • /
    • 2019
  • Recently the demand for drones is rapidly increasing, as developing Unmanned Aerial Vehicle (UAV) and growing interest in them. Compared to traditional satellite and aerial imagery, it can be used for various researches (environment, geographic information, ocean observation, and remote sensing) because it can be managed with low operating costs and effective data acquisition. However, there is a disadvantage in that only a small area is acquired compared to the satellite and an aircraft, which is a traditional remote sensing method, depending on the battery capacity of the UAV, and the distance limit between Ground Control System (GCS) and UAV. If remote control at long range is possible, the possibility of using UAV in the field of remote sensing can be increased. Therefore, there is a need for a communication network system capable of controlling regardless of the distance between the UAV and the GCS. The distance between UAV and GCS can be transmitted and received using simple radio devices (RF 2.4 GHz, 915 MHz, 433 MHz), which is limited to around 2 km. If the UAV can be managed simultaneously by improving the operating environment of the UAV using a Long-Term Evolution (LTE) communication network, it can make greater effects by converging with the existing industries. In this study, we performed the maximum straight-line distance 6.1 km, the test area 2.2 ㎢, and the total flight distance 41.75 km based on GCS through LTE communication. In addition, we analyzed the possibility of disconnected communication through the base station of LTE communication.

A Study on Perception by examinees of the Primary Health Care institutions about Exposure to Radioactivity (1차 의료기관에 내원한 환자의 방사선피폭 인지도에 관한 연구)

  • Yeo, Jin-Dong;Jeon, Byeong-Kyu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.6
    • /
    • pp.381-392
    • /
    • 2015
  • The purpose of this study was to investigate factors of perception by inpatients of the Primary Health Care institutions about exposure to radioactivity at the time of radioactive examination, providing basic information for making educational materials aimed to change their perception. Most of those patients, 65.5% responded that CT was a type of radioactive examination bringing highest exposure to radiosensitivity. Most of the subjects, 56.1% said that a body part most vulnerable to exposure to radiosensitivity was the genital gland at the time of radiosensitivity examination. And most of the participants, or 26.3% responded that they obtained information about radiation from TVs or newspapers. Among the surveyed patients, men were higher in scores for factors of the perception of radiation such as recognition of radiation, harmfulness of radiation, psychological state at the time of radioactive examination, prevention of exposure to radioactivity and necessity of radiation that women were, with statistically significant differences between the two groups. These findings suggest that it is urgently needed to develop an education program which helps patients better perceive exposure to radioactivity and that radiologists should be very careful to reduce the does of that exposure. If patients better perceive radiation, they would be less anxious and less exposed to radioactivity when receiving the radioactive examination.