• Title/Summary/Keyword: 촬영장치

Search Result 700, Processing Time 0.03 seconds

Development of Structure Dynamic Characteristics Analysis System Prototype using Image Processing Technique (영상처리기법을 이용한 구조물 동특성 분석 시스템 프로토타입 개발)

  • Jo, Byung-Wan;Lee, Yun-Sung;Kim, Jung-Hoon;Kim, Do-Keun;Yoon, Kwang-Won
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.3
    • /
    • pp.11-21
    • /
    • 2016
  • Recently, structure safety management techniques using cutting-edge technology(Displacement senor, sensor of acceleration) has emerged as an important issue owing to the aging of infrastructure such as bridge and building. In general, the structural monitoring system for structure safety management is based on IT technology and it is expensive to install. In this paper developed an image-based structure dynamic characteristic analysis system prototype to assess the damage of structure in a more cost-effective way than traditional structure health monitoring system. The inspector can take a video of buildings or other structures with digital camera or any other devices that is passible to take video, and then using NCC calculation for image processing technique to get natural frequency. This system is analysis of damage of the structure using a compare between the frequency response ratio and functions when problems are occurs send alarm to administrator. This system is easier to install and remove than previous monitoring sensor in economical way.

A Study on the Proper Chest Exposure Conditions of Mobile Digital X-ray Unit by Exposure Index (Exposure Index를 이용한 이동형 디지털 X선 장치의 흉부촬영 적정노출조건에 관한 연구)

  • Kim, Jae-In;Lee, Yang-Sub;Jang, Dong-Soo;Jung, Min-Cheol;Bae, Seung-Ho;Lee, Kwan-Sub;Ha, Dong-Yoon
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.13 no.3
    • /
    • pp.139-144
    • /
    • 2011
  • The purpose of this report is recommending a standard indicator which reflects the radiation exposure that is incident on a detector after every exposure event and that reflects the noise levels present in the image data. The experiment was performed with mobile digital X-ray unit and used a acrylic phantom for exposure index measurement. Exposure modality was kVp, mAs, SID. After every exposure, make a data sheet for characteristic curve of detector response. The equipment performed Mobile digital X-ray unit provide the user with values ralated to the incident exposure(air kerma)to the digital detector. They are showed as a logarithmic function shaped. As a result, DEI means a relative measure of exposure to the detector, as compared to the expected exposure for a particular anatomical view. Radiographic technique is the combination of factors used to exposure an anatomical part to produce a high quality radiography and technique charts used most commonly by radiographers to produce consistently exposure level which patient dose can be kept acceptably low.

  • PDF

A Study on the Characteristics of Ignition and Combustion, in a Diesel Spray Using Multi-Component Mixed Fuels (다성분 혼합연료를 이용한 디젤분무의 착화연소특성에 관한 연구)

  • Yoon, Jun-Kyu;Lim, Jong-Han
    • Journal of Energy Engineering
    • /
    • v.16 no.3
    • /
    • pp.120-127
    • /
    • 2007
  • The purpose of this study is experimentally to analyze that the fuel mass fractions of multi-component mixed fuels have an effect on the characteristics of spray ignition and combustion under the ambient conditions of diesel combustion fields. The characteristics of ignition and combustion were investigated by chemiluminescence images and direct photography. The experiments were conducted in the RCEM(rapid compression expansion machine) with optical access. Multi-component fuels mixed with i-octane, n-dodecane and n-hexadecane are injected in RCEM by the electronic control of common rail injector. Experimental conditions set up 42, 72 and 112 MPa in injection pressure, 700, 800 and 900 K in ambient gas temperature. The results show that the ignition delay was dependent on high cetane number. In case of low ambient temperature, the more low boiling point fuels were mixed, the lower luminance regime had a remarkable effect and also shortened diffusion combustion by increasing heat release rate.

Implementation of Digital Mammogram CAD Algorithm (디지털 유방영상의 CAD 알고리즘 구현)

  • Lee, Byungchea;Choi, Guirack;Jung, Jaeeun;Lee, Sangbock
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.1
    • /
    • pp.27-33
    • /
    • 2014
  • Medical imaging has increased rapidly in the increase of interest in health, with the development of computer technology, digitization of medical imaging is rapidly advancing, PACS has been introduced to the medical field. Increase in the production of medical images by these phenomena made increased the workload of radiologist who must read a medical image. in response to the need for secondary diagnosis using a computer, The term of CAD in medical radiology field was introduced. In this study, we have proposed a CAD algorithm for the interpretation of the image obtained by the digital X-ray mammography equipment. The experiments were performed by programmed in Visual C++ for the proposed algorithm. A result of the execution of the CAD algorithm seven sample images, the results of five samples was confirmed in breast cancer and benign tumors, both the images sample was error processing. If you use a program that implements this with the algorithm proposed in this study it is helpful to reading breast images, and it is considered to contribute significantly to the early detection of breast cancer.

Preparation of Eu-doped $YVO_4$ Red Phosphors by Solid-State Reaction Technique

  • Jang, Jae-Yeong;Bang, Jun-Hyeok;An, Se-Hyeok;Ma, Gwon-Do;Kim, Chun-Su;Jo, Sin-Ho
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.330-331
    • /
    • 2011
  • 희토류 이온이 첨가된 형광체는 조명, 정보 디스플레이, 태양 에너지 변환 소자에 응용 가능하기 때문에 상당한 주목을 받고 있다. 특히, 결정 입자의 형상과 크기는 산업체 응용에 있어서 중요한 변수 중의 하나이다. 구형의 형광체 입자는 형광층의 광학 및 기하학적 구조를 최적화 시킬 수 있고, 결정 입자의 크기는 양질의 코팅을 위해 필요한 결정 입자의 양에 영향을 미친다. 본 연구에서는, $YVO_4$ 모체 결정에 Eu 이온의 농도를 선택적으로 주입하여 발광 효율이 높은 적색 형광체를 합성하고자 한다. 형광체 분말 시료는 활성체인 Eu의 함량을 0.00, 0.05, 0.10, 0.15, 0.20 mol로 변화시키면서 고상 반응법을 사용하여 합성하였다. 볼밀링 작업을 수행한 후에, 60$^{\circ}C$에서 20시간 건조하였고, 잘게 갈아서 체로 걸러낸 다음에 세라믹 도가니에 넣고 전기로에서 서서히 온도를 승온시켜 500$^{\circ}C$에서 10시간 동안 하소를 실시한 후에 1,100$^{\circ}C$에서 5시간 동안 소결하였다. Eu 이온의 함량비를 변화시켜 합성한 $YVO_4$ : Eu 형광체 분말 시료의 발광 세기의 변화, 결정 구조와 표면 형상을 각각 PL과 PLE, XRD, FE-SEM 장치를 사용하여 측정한 결과들을 종합해 볼 때, Eu 이온의 비가 0.15 mol일때 발광 세기가 최대값을 나타냄을 알 수 있었으며, 더욱 Eu의 함량을 증가시키자 농도 억제 현상에 의하여 발광 세기는 급격히 감소함을 보였다. SEM으로 촬영한 결정 입자의 형상의 경우에, Eu 이온의 함량비가 증가함에 따라 결정 입자들이 더욱 조밀하게 구형에 가까운 형상을 나타냄을 관측할 수 있었다(Fig. 1). 형광체 분말의 형광 스펙트럼의 경우에, 619 nm에 주 피크를 갖는 적색 형광 스펙트럼들이 관측되었으며, Eu 이온의 함량비에 따라 형광 세기는 상당한 의존성을 나타내었다(Fig. 2). Eu 함량에 따른 결정입자의 크기, 형광 세기와 회절 피크의 반치폭 사이의 상관 관계를 제시하고자 한다.

  • PDF

2D Adjacency Matrix Generation using DCT for UWV Contents (DCT를 통한 UWV 콘텐츠의 2D 인접도 행렬 생성)

  • Xiaorui, Li;Kim, Kyuheon
    • Journal of Broadcast Engineering
    • /
    • v.22 no.3
    • /
    • pp.366-374
    • /
    • 2017
  • Since a display device such as TV or digital signage is getting larger, the types of media is getting changed into wider view one such as UHD, panoramic and jigsaw-like media. Especially, panoramic and jigsaw-like media is realized by stitching video clips, which are captured by different camera or devices. However, a stitching process takes long time, and has difficulties in applying for a real-time process. Thus, this paper suggests to find out 2D Adjacency Matrix, which tells spatial relationships among those video clips in order to decrease a stitching processing time. Using the Discrete Cosine Transform (DCT), we convert the each frame of video source from the spatial domain (2D) into frequency domain. Based on the aforementioned features, 2D Adjacency Matrix of images could be found that we can efficiently make the spatial map of the images by using DCT. This paper proposes a new method of generating 2D adjacency matrix by using DCT for producing a panoramic and jigsaw-like media through various individual video clips.

Development of Mobile Camera Vision System and Build of Wire.Wireless Integration ERP System (모바일 카메라 비전 시스템 개발과 유.무선 통합 ERP 시스템 구축)

  • Lee, Hyae-Jung;Shin, Hyun-Cheol;Joung, Suck-Tae
    • Convergence Security Journal
    • /
    • v.7 no.2
    • /
    • pp.81-89
    • /
    • 2007
  • Mobile computing environment that support so that can offer employees inside information that enterprise has always improves business productivity and fetches efficiency enlargement. In this paper, limit model that can process ERP information by real-time as easy and convenient always utilizing radio network and PDA, Mobile camera based on Mobile vision concept. Calculable information between seller and customer is supplied supplying real-time brand image and information by practical use of Enterprise Resource Planning doing based on Mobile. Technical development and commercialization that utilize mobility, enforcement stronghold, portability etc. that is advantage of Mobile communication are required. In this paper, mobility of precious metals.jewel field that use portable terminal equipment taking advantage of a Mobile technology is secured. Constructed Mobile vision system that satisfy photography and bar-code scan at the same time from Mobile camera.

  • PDF

Comparison of personal computer with CT workstation in the evaluation of 3-dimensional CT image of the skull (전산화단층촬영 단말장치와 개인용 컴퓨터에서 재구성한 두부 3차원 전산화단층영상의 비교)

  • Kang Bok-Hee;Kim Kee-Deog;Park Chang-Seo
    • Imaging Science in Dentistry
    • /
    • v.31 no.1
    • /
    • pp.1-7
    • /
    • 2001
  • Purpose : To evaluate the usefulness of the reconstructed 3-dimensional image on the personal computer in comparison with that of the CT workstation by quantitative comparison and analysis. Materials and Methods : The spiral CT data obtained from 27 persons were transferred from the CT workstation to a personal computer, and they were reconstructed as 3-dimensional image on the personal computer using V-works 2.0/sup TM/. One observer obtained the 14 measurements on the reconstructed 3-dimensional image on both the CT workstation and the personal computer. Paired Nest was used to evaluate the intraobserver difference and the mean value of the each measurement on the CT workstation and the personal computer. Pearson correlation analysis and % incongruence were also performed. Results: I-Gn, N-Gn, N-A, N-Ns, B-A, and G-Op did not show any statistically significant difference (p>0.05), B-O, B-N, Eu-Eu, Zy-Zy, Biw, D-D, Orbrd R, and L had statistically significant difference (p<0.05), but the mean values of the differences of all measurements were below 2 mm, except for D-D. The value of correlation coefficient y was greater than 0.95 at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and it was 0.75 at B-O, 0.78 at D-D, and 0.82 at both Orbrd Rand L. The % incongruence was below 4% at I-Gn, N-Gn, N-A, N-Ns, B-A, B-N, G-Op, Eu-Eu, Zy-Zy, and Biw, and 7.18%, 10.78%, 4.97%, 5.89% at B-O, D-D, Orbrd Rand L respectively. Conclusion : It can be considered that the utilization of the personal computer has great usefulness in reconstruction of the 3-dimensional image when it comes to the economics, accessibility and convenience, except for thin bones and the landmarks which are difficult to be located.

  • PDF

Anatomical structure of lingual foramen in cone beam computed tomography (Cone beam형 전산화 단층촬영장치를 이용한 설공의 해부학적 구조)

  • Ki Min-Woo;Hwang Eui-Hwan;Lee Sang-Rae
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.129-136
    • /
    • 2004
  • Purpose: To evaluate whether cone beam computed tomography can depict the distribution, position, frequency, relative vertical dimension, and the diameter of the lingual foramen and direction of lingual bone canal. Materials and Methods : Cone beam computed tomography of mandible was performed on 25 males and 25 females with no history of any orthodontic treatments or any other dental surgeries. A statistical comparison was done on the mean values of males and females. Results: In the location and distribution of lingual foramina, median lingual foramen was found in all subjects and lateral lingual foramen in 58%. In the lateral lingual foramen, bilateral type was found in 28% and unilateral type in 30%. In the number of lingual foramina, median lingual foramen had two foramina and lateral lingual foramen had one foramen, mostly. In the relative mean vertical dimension of lingual foramina, median lingual foramen was 0.03±0.08, and both lateral lingual foramina was 0.20±0.04. The mean diameter of lingual foramina, median lingual foramen was 0.9mm±0.28, right lateral lingual foramen was 0.92mm±0.23, and left lateral lingual foramen was 0.88mm±0.27. The most frequent direction of the lingual bone canals, median lingual bone canal proceeded in anteroinferior direction and lateral lingual bone canal in anterosuperolateral direction. Conclusion : Cone beam computed tomography can be helpful for surgery and implantation on the mandibular area. Radiologist should be aware of this anatomical feature and its possible implications.

  • PDF

Development of Self-Diagnosis Linearity Quality Assurance Technique in Computed Tomography by Using Iodic Contrast Media (요오드 조영제를 이용한 전산화단층촬영장치의 자가진단 직선성 정도관리 기술 개발)

  • Seoung, Youl-Hun
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.5
    • /
    • pp.436-443
    • /
    • 2015
  • The purpose of this study was to develop a self-diagnostic linearity quality control techniques of computed tomography (CT) by using measured CT number values from the various concentrations of iodine contrast media (CM) is diluted with distilled water under each condition of the tube voltage. The equipment was used for four-channel MDCT, the iodine concentration were using 300 mgI/ml, 350 mgI/ml, 370 mgI/ml and 400mgI/ml. Dilution of CM in distilled water was increased by each 5% until the maximum CT number values were measured. We applied the tube voltages for 90 kVp, 120 kVp, 140 kVp. As a result, we was obtained to the nearest linearity as 0.993 of correlation coefficient between the iodinated CM from 5% to 25% in 400 mgI/ml and the CT number values by 90 kVp. In conclusion, the proposed self-diagnostic linearity quality assurance technique by using iodine CM can be utilized to replace the AAPM CT performance phantom.