• Title/Summary/Keyword: 초점크기

Search Result 450, Processing Time 0.027 seconds

Property of Focal Spot of Electron Beam Depending on the Anode Angle of X-ray Tube Using a Finite Element Method (유한요소법을 이용한 X-선관 양극각도에 의존하는 전자빔 초점 특성 연구)

  • Park, Tae-Young;Noh, Young-Il;Lee, Sang-Suk;Park, Rae-Jun;Kim, Ki-Seon
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.2
    • /
    • pp.52-57
    • /
    • 2015
  • The focal spot of electron beam depending on the anode angle in the structure and major parts of the X-ray tube was investigated by the OPERA-3D/SCALAR simulation program. The simulation worked on four spaces with with two spaces, including anode and cathode of X-ray tube, by applying the finite element method analysis. The analytical model and dimension for the emission orbit of thermal electrons made from one filament of the focused X-ray cathode is affected to the penumbra of detector for the X-ray depending on any real focal spot size. The model shape of focusing cap and focusing tube with an anode target angle and a cathode filament is analyzed by the current density distribution of thermal electrons. The focusing width of thermal electrons for the X-ray tube depended on the anode angle (${\theta}$). The focusing value of electron beams at a region of anode angle having $10^{\circ}{\sim}17^{\circ}$ maintained to below value of $70{\mu}m$. The minimum focal size of the electron beam was $40{\mu}m$ at an anode angle of $15^{\circ}$. The focused X-ray tube of many variables depended on the thermionic emission of hot electrons from the target trajectory. The focusing tube will contribute to the real design of X-ray for the development of future diagnosis medical device.

Quantitative Analysis of Spatial Resolution for the Influence of the Focus Size and Digital Image Post-Processing on the Computed Radiography (CR(Computed Radiography)에서 초점 크기와 디지털영상후처리에 따른 공간분해능의 정량적 분석)

  • Seoung, Youl-Hun
    • Journal of Digital Convergence
    • /
    • v.12 no.11
    • /
    • pp.407-414
    • /
    • 2014
  • The aim of the present study was to carry out quantitative analysis of spatial resolution for the influence of the focus size and digital image post-processing on the Computed Radiography (CR). The modulation transfer functions of an edge measuring method (MTF) was used for the evaluation of the spatial resolution. The focus size of X-ray tube was used the small focus (0.6 mm) and the large focus (1.2 mm). We evaluated the 50% and 10% of MTF for the enhancement of edge and contrast by using multi-scale image contrast amplification (MUSICA) in digital image post-processing. As a results, the edge enhancement than the contrast enhancement were significantly higher the spatial resolution of MTF 50% in all focus. Also the spatial resolution of the obtained images in a large focus were improved by digital image processing. In conclusion, the results of this study should serve as a basic data for obtain the high resolution clinical images, such as skeletal and chest images on the CR.

Distribution of X-ray Strength in Exposure Field Caused by Heel Effect (양극의 경사각 효과에 따른 조사야 X-선 강도 분포)

  • Jang, Keun-Jo;Kim, Nam-Hun;Lee, Jun-Haeng;Lee, Sang-Bock
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.223-229
    • /
    • 2011
  • When negative electron in x-ray tube is accelerated in to a high speed and then the currency of the electron is blocked by the target, x-ray happens by the conversion of the energy. The real area where the fast accelerated electron collides to a target area is called actual focal spot. When the string focused size is observed at the central ray side, where the direction x-ray comes out, the size seems to be reduced. This focus is called effective focal spot. According to radiation angle of x-rays tube, the degree of the negative pole side presents higher value than inclination, the amount of exposed radiation that patient receives differs by the angle of positive pole, which means effective focal spot is the variable. This paper presents the correlation between size of effective focal spot and amount of exposed radiation to the patient by it, and effective research for homogenized dose dispersion by the size of effective focal spot. In conclusion, following the focal size, effective range which was -8cm ~ 0 cm on average, was found and average dose rate was 0.019 R/min. Through this range, for patients with small radiation exposure, image with good density and resolution in aspect of diagnosing will be able to be obtained.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

Study on the auto focus digital camera uses a Liquid Lens. (Liquid Lens를 사용하는 디지털 카메라의 자동초점조절에 관한 연구)

  • Kim, Nam-woo;Hur, Chang-Wu
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.557-560
    • /
    • 2015
  • 자동초점이란 영상을 획득하는 시스템에서 고정된 촬상면에 자동으로 초점이 맺히도록 렌즈를 구동시키는 방식으로 컴퓨터비전과 카메라 등에서 매우 중요하게 사용된다. 소형 카메라의 경우 자동초점에서 렌즈구동부인 actuator의 기술은 대량생산이 이용이하고, 위치센서가 불필요하며, 회로구성이 용이한 VCM방식이 널리 사용되고 있으며, 구동의 안정성에 비해 크기와 소음이 큰 스테핑모터 방식, 크기는 가장 작지만 납 함유문제 및 습도 취약성을 갖는 피에조 방식이 있다. 그 외에 액체렌즈방식이 있는데, 소형 구조에 저전력의 장점이 있지만 화질 및 신뢰성 검증 그리고 고압이 필요한 특징을 가지는 구조도 있다. 본 논문에서 5Mpixel급 이미지 센서를 통해 획득한 영상의 선예도를 이용하여 VCM의 actuator처럼 액체렌지를 제어하여 자동으로 초점을 맞추는 제어방식을 구현하고 검증하였다.

  • PDF

Topic vs. Focus Dichotomy

  • Kim, Yong-Beom
    • Proceedings of the Korean Society for Language and Information Conference
    • /
    • 2002.06a
    • /
    • pp.153-161
    • /
    • 2002
  • 본 논문에서는 주제와 초점이 한가지 기준에 의해 분류될 수 있는 것을 보이고자 한다. 이를 위해서 Rooth의 대안 의미론의 요점인 대안 집합이 어떤 방식으로 결정되고 그 대안 집합의 크기가 얼마가 되느냐에 따라서 여러 가지 주제와 초점이 분류되었다 또한 정보초점에 나타나는 초점의 한정성은 초점자체의 본성이라기보다는 이전 발화의 전제에 의한 상호작용의 결과라는 것을 보였고, 대조 초점과 대조주제의 구분을 위하여 대화함축이 일어나는지 여부를 기준으로 이 두 개념을 구분하려고 하였다.

  • PDF

Out-of focus blur estimation using variable-sized blocks and basis images (가변블록과 기저영상을 사용한 초점불완전 열화시스템 추정기법)

  • 조충남;박상래;백준기
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.81-85
    • /
    • 1998
  • 점확산 함수(point spread function; PSF)의 정확한 추정은 복원결과가 원 영상에 얼마나 근접할 수 있는가를 결정한다는 점에서 영상처리의 중요한 연구 주제중의 하나가 된다. 본 논문에서는 PSF를 추정하기 위한 알고리즘을 제안하고, 이를 영상복원에 적용한 후 이를 기반으로 디지털 자동초점시스템을 제안한다. 초점불안전 열화시스템을 구현하기 위한 과정은 두 단계로 구성되어 있는데, 즉 입력 영상에서 에지분류를 통한 PSF 추정과, 이를 이용한 영상복원이다. 보다 구체적으로, 입력 영상에 특정 에지가 있는 임의의 크기의 블록을 선정해부면, 그 블록으로부터 자동으로 에지방향이 기저영상을 이용해서 구해지며 확산원의 크기를 추정하여 1차원 단위 계단응답과 영역을 구하여 평균한 후, 2차원 등방성 PSF를 추정한다. 마지막으로 추정된 PSF를 사용하여 복원을 수행함으로써 초점이 맞는 영상을 구한다.

  • PDF

자동관측 망원경을 위한 자동 초점 알고리즘 개발

  • Yun, Yo-Ra;Lee, Chung-Uk;Im, Hong-Seo;Han, Won-Yong
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.65.2-65.2
    • /
    • 2011
  • 천체관측에서 가장 중요한 요소인 초점은 관측된 영상의 활용가치를 좌우하게 된다. 관측자가 직접 관측하는 망원경의 경우 직접적인 확인을 통하여 초점을 맞추어 관측하지만, 관측자가 개입하지 않는 자동관측 망원경의 경우 초점을 맞추는 일은 생각처럼 쉬운 일이 아니다. 자동으로 초점을 맞추기 위하여 기본적으로 활용되는 변수는 FWHM(Full with Half Maximum)이며, 초점이 전혀 맞지 않는 영상의 경우 FWHM을 결정할 수 없으며, 자동관측 망원경의 경우 관측된 영상을 전부 사용할 수 없게 된다. 본 연구에서는 초점이 전혀 맞지 않는 경우에도 초점을 맞출 수 있도록 FWHM을 활용하지 않고 별상의 크기를 직접 계산하여 좋은 초점을 맞출 수 있는 프로그램을 개발하였으며, 새로 개발한 프로그램은 결과 도출시간이 빠르고 광축이 맞지 않은 영상에서도 활용할 수 있어 활용성을 극대화 하였다. 한편, 리눅스 및 윈도우 기반의 영상 관측 컴퓨터에서도 활용할 수 있어 앞으로 활용성이 더 많아 질 것으로 기대한다.

  • PDF