• Title/Summary/Keyword: 초음파 C 스캔

Search Result 39, Processing Time 0.023 seconds

Medical Application of the Nondestructive Ultrasonic Tests: Diagnosis of Micro Bone Fractures using Ultrasonic C Scan Images (비파괴 초음파 검사법의 의학적 활용: 초음파 C 스캔 영상을 이용한 미세 골절의 진단)

  • Choi, Min-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.4
    • /
    • pp.377-385
    • /
    • 2002
  • Ultrasonic tests employing non-ionizing radiation are preferred in nondestructive examinations since they are safe and simple in use. The same principles of the techniques have been taken as valuable tools in medical area for the diagnoses of diseases, in other words, defects of the human body. The paper overviews the principles of the medical diagnosis based on nondestructive ultrasonic tests, and then evaluates experimentally the clinical potential of C scan images not popular in medicine, for detecting the micro fractures of the cortical bone. In the experiment the micro bone fractures were created on the femurs of porks by loading three point bending forces (2-4kN) with the speed of 1 mm/min. As the extent of the fracture was altered, not only X ray images but also ultrasonic C scan images using a focused ultrasonic probe resonated at 25 MHz were obtained. The results showed that ultrasonic C scan images were capable of detecting the micro bone fractures which were not possible to identify by conventional X ray images.

Development of Double Rotation C-Scanning System and Program for Under-Sodium Viewing of Sodium-Cooled Fast Reactor (소듐냉각고속로 소듐 내부 가시화를 위한 이중회전구동 C-스캔 시스템 및 프로그램 개발)

  • Joo, Young-Sang;Bae, Jin-Ho;Park, Chang-Gyu;Lee, Jae-Han;Kim, Jong-Bum
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.4
    • /
    • pp.338-344
    • /
    • 2010
  • A double rotation C-scanning system and a software program Under-Sodium MultiVIEW have been developed for the under-sodium viewing of a reactor core and in-vessel structures of a sodium-cooled fast reactor KALIMER-600. Double rotation C-scanning system has been designed and manufactured by the reproduction of double rotation plug of a reactor head in KALIMER-600. Hardware system which consists of a double rotating scanner, ultrasonic waveguide sensors, a high power ultrasonic pulser-receiver, a scanner driving module and a multi channel A/D board have been constructed. The functions of scanner control, image mapping and signal processing of Under-Sodium MultiVIEW program have been implemented by using a LabVIEW graphical programming language. The performance of Under-Sodium MultiVIEW program was verified by a double rotation C-scanning test in water.

Ultrasonic Backward Radiation on Randomly Rough Surface (무작위로 거친 표면에서의 후방복사 초음파)

  • Kwon, Sung-D.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.25 no.1
    • /
    • pp.9-14
    • /
    • 2005
  • The angular dependence(profile) of backward radiated ultrasound was measured for glass specimens with random surface roughness using ultrasonic goniometer that ran changes the incident angle continuously. It was concluded that the roughened region had greater acoustic impedance than the unperturbed region. The comparison of backward radiations showed that the amplitude of peak and the area of radiation profile were increased with surface roughness. It was suggested from the sensitive dependence of the profile area that the profile of backward radiation could be applied to in the nondestructive evaluation of sulfate region. Inclined C-scan technique with the transducer inclined at Rayleigh angle showed the reverse of luminosity and the high signal to noise ratio so that it provided high resolution.

Development of Image Processing Software for UT-NDE of Steam Generator of Nuclear Power Plant (핵발전소 증기발생기의 초음파 비파괴 평가를 위한 영상처리 소프트웨어 개발)

  • Lee, Young-Seock;Nam, Myoung-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.8 no.2
    • /
    • pp.226-231
    • /
    • 2007
  • This paper describes a development of ultrasonic examination analysis software to analyze steam generator of nuclear power plant. The developed software includes classical analysis method such as A, B, C and D-scan images. This software provides the information of shape, depth, size and position of flaws. To do such, we obtain raw data from specimens and/or real pipeline of power plants and, modify the obtained ultrasonic 1-dimensional data according to prepared software design schedule. The developed analysis software is applied to specimens containing various flaws with known dimensions. The results of applications showed that the developed software provided accurate and enhanced images of flaws on various specimens.

  • PDF

Differences in the Clinical Characteristics of Children with Urinary Tract Infections Based on the Results of $^{99m}Tc$-Dimercaptosuccinic Acid Renal Scanning (요로감염 소아에서 입원 초기 시행한 DMSA 신 스캔 결과에 따른 임상양상의 차이에 대한 연구: DMSA 신 스캔의 임상적 의미)

  • Kim, Dong Ouk;Lee, Sang Min;Lee, Jeong Bong;Ko, Young Bin;Kim, Su Jin
    • Childhood Kidney Diseases
    • /
    • v.17 no.2
    • /
    • pp.110-116
    • /
    • 2013
  • Purpose: The $^{99m}Tc$-Dimercaptosuccinic acid (DMSA) renal scan is used primarily for the diagnosis of renal scarring and acute pyelonephritis in children with urinary tract infections (UTI). This study aimed to evaluate clinical differences based on the positive or negative results of DMSA scans and kidney ultrasonography (US) in pediatric UTI. Method: We retrospectively reviewed 142 pediatric patients with UTI who were admitted to Myongji Hospital from January 2004 to December 2012. We performed a comparative analysis of clinical parameters such as age, sex, white blood cell (WBC) count, neutrophil count, blood urea nitrogen (BUN) level, creatinine (Cr) level, C-reactive protein (CRP) level, and durations of hospitalization and fever, grouped by the results of the DMSA scans and kidney US. Results: The mean age of the patients was $33.8{\pm}48.3$ months, and 78 (55%) were male. Fifty-two patients had abnormal DMSA findings, and 71 patients had abormal kidney US findings (test positive groups). In the DMSA scan positive group, there were significant differences in age, WBC counts, neutrophil counts, CRP level, BUN level, Cr level, hospitalization duration, number of abnormal findings on kidney US, and incidence of vesicoureteral reflux (VUR) compared with the scan negative group. The kidney US positive group had significant differences in age, neutrophil count, CRP level, BUN level, Cr level, hospitalization duration, number of abnormal findings on the DMSA scans, and more frequent VUR compared with the US negative group. Conclusion: Our data suggest that there were no major differences in clinical parameters based on the results of the DMSA scans compared with kidney US in pediatric UTI. However, as kidney US and DMSA scan were performed to predict VUR, the sensitivity and negative predictive value was increased.

Nondestructive Evaluation Technique of Painted Sandwich Control Surfaces of CN-235 using Full-field Pulse-echo Ultrasonic Propagation Imaging System (전영역 펄스-에코 초음파전파영상화 시스템의 CN-235의 도색된 샌드위치 조종면 In-situ 비파괴평가 기술)

  • Hong, Seung-Chan;Lee, Jung-Ryul;Park, Jongwoon
    • Composites Research
    • /
    • v.29 no.5
    • /
    • pp.288-292
    • /
    • 2016
  • In this paper, a novel ultrasonic propagation imaging system, called a full-field pulse-echo ultrasonic propagation imaging (FF PE UPI) system is introduced. The system nondestructively inspected targets with two-axis translation stage. The coincident laser beams for ultrasonic sensing and generation are scanned and pulse-echo mode laser ultrasounds are captured. This procedure makes it possible to generate full-field ultrasound in through-the-thickness direction as large as the scan area. Structural inspection results in the form of full-field ultrasonic wave propagation videos are introduced, which are painted sandwich control surfaces. In addition, the inspection results of FF PE UPI system are compared with conventional ultrasonic testing methods such as waterjet and portable C-scan.

Evaluation of Internal Defect of Composite Laminates Using A Novel Hybrid Laser Generation/Air-Coupled Detection Ultrasonic System (레이저 발생 초음파와 공기 정합 수신 탐촉자를 이용한 복합재료 적층판의 내부 박리 결함 평가)

  • Lee, Joon-Hyun;Lee, Seung-Joon;Byun, Joon-Hyung
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.1
    • /
    • pp.46-53
    • /
    • 2008
  • Ultrasonic C-scan technique is one of very popular techniques being used for detection of flaws in polymer matrix composite(PMC). However, the application of this technique is very limited for evaluation of defects in PMC fabricated by the automated fiber placement process. The purpose of this study is to develop a novel ultrasonic hybrid system based on nondestructive and non-contact ultrasonic techniques for evaluation of delamination in carbon/epoxy and carbon/PPS composite laminates. It was shown that the newly developed ultrasonic hybrid system based on dual air-coupled pitch-catch technique with ultrasonic scattering reflection concept could provide excellent image with higher resolution of delamination in PMC compared with the conventional pitch-catch method. It is expected that this ultrasonic hybrid technique can be applied for on-line inspection of flaws in PMC during the fabrication process.

Ultrasonic C-scan System Development Using DSP (DSP 를 이용한 초음파 C-scan 시스템 개발)

  • Nam, Young-Hyun;Seong, Un-Hak;Kim, Jeong-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.16 no.7
    • /
    • pp.32-39
    • /
    • 1999
  • Digital signal processor (DSP) is used to obtain the peak value and the time difference of ultrasonic signals, to make digital filter, and to derive mathematical transformation from analog circuit. In this study, C-scan system and control program have been developed to high speed data acquisition. This system consists of signal processing parts (DSP, oscilloscope, pulser/receiver, digitizer), scanner, and control program. The developed system has been applied to a practical ultrasonic testing in overlay weld, and demonstrated high speed with precision

  • PDF

A Feasibility Study on the Application of Ultrasonic Method for Surface Crack Detection of SiC/SiC Composite Ceramics (SiC/SiC 복합재료 세라믹스 표면균열 탐지를 위한 초음파법 적용에 관한 기초연구)

  • Nam, Ki-Woo;Lee, Kun-Chan;Kohyama, Akira
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.29 no.5
    • /
    • pp.479-484
    • /
    • 2009
  • Nondestructive evaluation(NDE) of ceramic matrix composites is essential for developing reliable ceramics for industrial applications. In the work, C-Scan image analysis has been used to characterize surface crack of SiC ceramics nondestructively. The possibility of detection of surface crack were carried out experimentally by two types of ultrasonic equipment of SDS-win and $\mu$-SDS, and three types of transducer of 25, 50 and 125 MHz. A surface micro-crack of ceramics was not detected by transducer of 25 MHz and 50 MHz. Though the focus method was detected dimly the crack by transducer of 125 MHz, the defocus method could detect the shape of diamond indenter. As a whole, the focus method and the defocus method came to the conclusion that micro crack have a good possibility for detection.

The Diagnostic Value of Clinical and Radiologic Findings in Children after the First Episode of Acute Pyelonephritis (소아에서의 첫 번째 급성 신우신염에 따른 임상 소견 및 방사선학적 검사의 진단적 유용성)

  • Kim Ji Hae;Kim Mi Jung;Choi Byung Min;Yoo Kee Hwan;Hong Young Sook;Lee Joo Won
    • Childhood Kidney Diseases
    • /
    • v.9 no.2
    • /
    • pp.201-212
    • /
    • 2005
  • Purpose : Acute pyelonephritis is one of the most common causes of unexplained fever in children. It may lead to the development of progressive renal damage. However, the deteclion of acute pyelonephritis can be difficult, especially in infants. The objective of this study was to evaluate the diagnostic value of various lab tests and imaging studies for acute renal parenchymal changes in children with APN. We correlated the clinical and laboratory manifestations of acute pyelonephritis with the Imaging studies. Methods : We reviewed the records of 115 children (85 males and 30 females) who were hospitalized Outing the period of January 1998 to December 2002 with initial clinical symptoms suggestive of pyelonephritis. The patients' age, sex, duration of fever, laboratory findings, and causative organisms were compared with the findings of imaging studies (Technetium-99m dimercaptosuccinic acid renal scan, renal ultrasonography, intravenous pyelography, voiding cystourethrography). Results : No significant relation between the number of febrile days, leukocyte count, causative organism, and the renal abnormalities in the imaging studies were observed. On the other hand, both C-reactive protein and erythrocyte sedimentation rate levels were significantly elevated in children with positive dimercaptosuccinic acid renal scan. Furthermore, females and children older than 1 year presented with significantly higher rate of abnormal dimercaptosuccinic acid renal scan findings and vesicoureteral reflux presented by voiding cystourethrography. Conclusion : We recommend females and children older than 1 year who are suspected of acute pyelonephritis be evaluated carefully for renal involvement by performing imaging studies including dimercaptosuccinic acid renal scan and voiding cystourethrography. (J Koroan Soc Pediatr Nephrol 2005;9:201-212)

  • PDF