• Title/Summary/Keyword: 초음파 흡수

Search Result 77, Processing Time 0.028 seconds

An Experimental Application of Consolidants Using Artificially Weathered Stones (인공풍화암을 이용한 강화제의 적용실험 연구)

  • Lee, Jae Man;Lee, Myeong Seong;Kim, Jae Hwan;Lee, Mi Hye;Park, Sung Mi
    • Journal of Conservation Science
    • /
    • v.28 no.3
    • /
    • pp.285-296
    • /
    • 2012
  • This study was to assess the effect of consolidation for intension measures of stone cultural heritage using artificially weathered stones. We have prepared four kinds of stones (Gyeongju Namsan Granite, Iksan Granite, Yeongyang Sandstone, Jeongseon Marble), and manufactured fresh, weathered and highly weathered stone samples by thermal shock for each rock type. The samples were treated with three consolidants (Wacker OH 100, Remmers KSE 300, 1T1G) by three methods {immersion, capillary rise (partial immersion), spray}, and tested for weight, porosity, ultrasonic velocity, Equotip hardness and color before and after treatment. As a result, the effect of consolidation was widely influenced by porosity and treatment methods. Wacker OH 100 was shown the highest consolidation effect in almost every stone sample.

유연성 투명전도막의 전기적 특성에 미치는 CNT 길이의 영향

  • Sin, Ui-Cheol;Jeong, Gu-Hwan
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.456-456
    • /
    • 2011
  • 최근 차세대 디스플레이, 터치스크린, 전자파 차폐 및 흡수 등의 다양한 응용분야에 적합한 소재를 개발하기 위한 연구가 진행되고 있다. 현재 주로 사용되는 ITO박막은 희소원소인 인듐의 매장량 한계와 높은 비용이 문제시 되고 있기 때문에, 대체 재료의 개발이 시급하게 요구되고 있다. 탄소나노튜브(CNT)는 금속을 능가하는 이론적인 전기전도도를 갖고 있으며 높은 탄성등의 우수한 기계적 성질을 갖고 있어 다양한 차세대 응용에 있어서 최적의 재료로 주목을 받고 있다. 특히, CNT 기반의 투명전도막은 기존의 ITO 박막 보다 우수한 유연성이 기대되어 더욱 기대를 모으고 있다. 본 연구에서는, 최종 고순도 재료를 얻기까지 합성 및 정제에 많은 공정과 시간이 요구되는 고가의 단층벽 나노튜브(SWNT)를 이용하지 않고, 웨이퍼 기판 위에 수직배향 합성한 상태의 다층벽 나노튜브(MWNT)를 별도의 정제과정 없이 초음파 분산한 뒤, 스프레이 코팅법을 이용하여 고분자 기판 위에 투명전도막을 제작하였고, 이때 각기 다른 길이의 수직배향 MWNT를 이용하여 유연성 투명전도막의 전기적 특성에 미치는 MWNT 길이의 영향에 대해 알아보았다. MWNT는 아세틸렌가스를 이용하여 열CVD법으로 합성하였고, 합성시간을 제어함으로써 길이가 다른 MWNT를 얻을 수 있었다. 투명전도막 제조공정의 단순화를 위하여 이용한 MWNT의 초음파 분산 결과, $500{\mu}m$ 이하 길이의 MWNT에서 분산성이 현저히 빨라지는 것을 확인하였다. 한편, 제작한 MWNT 기반의 유연성 투명전도막은 원자간힘현미경 및 면저항 측정기를 이용하여 막 두께에 따른 면저항 특성을 조사하였다. 그 결과 응용 가능한 면저항을 갖는 MWNT 투명전도막의 두께는 최소 50 nm 이상이어야 함을 알았고, 특히 MWNT등의 접촉점(node) 수에 따른 접촉저항 및 전기전도경로(electric conductivity path)를 고려했을 때 최적의 MWNT 길이가 존재하는 것을 확인하였다.

  • PDF

Comparison of Ultrasound Image Quality using Edge Enhancement Mask (경계면 강조 마스크를 이용한 초음파 영상 화질 비교)

  • Jung-Min, Son;Jun-Haeng, Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.157-165
    • /
    • 2023
  • Ultrasound imaging uses sound waves of frequencies to cause physical actions such as reflection, absorption, refraction, and transmission at the edge between different tissues. Improvement is needed because there is a lot of noise due to the characteristics of the data generated from the ultrasound equipment, and it is difficult to grasp the shape of the tissue to be actually observed because the edge is vague. The edge enhancement method is used as a method to solve the case where the edge surface looks clumped due to a decrease in image quality. In this paper, as a method to strengthen the interface, the quality improvement was confirmed by strengthening the interface, which is the high-frequency part, in each image using an unsharpening mask and high boost. The mask filtering used for each image was evaluated by measuring PSNR and SNR. Abdominal, head, heart, liver, kidney, breast, and fetal images were obtained from Philips epiq5g and affiniti70g and Alpinion E-cube 15 ultrasound equipment. The program used to implement the algorithm was implemented with MATLAB R2022a of MathWorks. The unsharpening and high-boost mask array size was set to 3*3, and the laplacian filter, a spatial filter used to create outline-enhanced images, was applied equally to both masks. ImageJ program was used for quantitative evaluation of image quality. As a result of applying the mask filter to various ultrasound images, the subjective image quality showed that the overall contour lines of the image were clearly visible when unsharpening and high-boost mask were applied to the original image. When comparing the quantitative image quality, the image quality of the image to which the unsharpening mask and the high boost mask were applied was evaluated higher than that of the original image. In the portal vein, head, gallbladder, and kidney images, the SNR, PSNR, RMSE and MAE of the image to which the high-boost mask was applied were measured to be high. Conversely, for images of the heart, breast, and fetus, SNR, PSNR, RMSE and MAE values were measured as images with the unsharpening mask applied. It is thought that using the optimal mask according to the image will help to improve the image quality, and the contour information was provided to improve the image quality.

Characteristic Analysis of Falling Weight Impact Response in CF/Epoxy Composite Plates Using Frequency Responses (주파수 응답을 이용한 CF/Epoxy 복합적층판의 낙추충격 특성평가)

  • 임광희;박노식;김영남;김선규;양인영
    • Composites Research
    • /
    • v.16 no.2
    • /
    • pp.9-17
    • /
    • 2003
  • We have implemented a system of falling weight impact tester in order to evaluate the impact energy absorbing characteristics and impact strength of CFRP laminate plates. The absorbed energy of T-300 orthotropic composites is higher than that of quasi-isotropic specimen over impact energy 7J, but in case of using T700 fiber, much difference does not show. Also, absorbed energy of T-300 orthotropic composites, which are composed of the same stacking number and orientation became more than that of T700 fiber specimen however there was no big difference in case of quasi-isotropic specimens. Delamination area of impacted specimens was measured with ultrasonic C-scanner to find correlation between impact energy and delamination area. Delamination area and frequency responses were evaluated between impacted and unimpacted specimens. There is a strong correlation between frequency responses and impact-induced delamination. The presence and scale of damages have been investigated based on the variations of frequency responses.

Measurements of Actual Effective Half-Life in $^{131}I$ Therapy for Graves' Hyperthyroidism (그레이브스 갑상선기능항진증 환자의 방사성옥소($^{131}I$) 치료시 실제 유효반감기의 측정)

  • So, Yong-Seon;Kim, Myung-Seon;Kwon, Ki-Hyun;Kim, Seok-Whan;Kim, Tae-Hyung;Han, Sang-Woong;Kim, Eun-Sil;Kim, Chong-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.1
    • /
    • pp.77-85
    • /
    • 1996
  • Radioiodine($^{131}I$) has been used for the treatment of Graves' hyperthyroidism since the late 1940's and is now generally regarded as the treatment of choice for Graves' hyperthyroidism who does not remit following a course of antithyroid drugs. But for the dose given, several different protocols have been described by different centers, each attempting to reduce the incidence of long-term hypothyroidism while maintaining an acceptable rate control of Graves' hyperthyroidism. Our goals were to evaluate effective half-life and predict absorbed dose in Graves' hyperthyroidism patients, therefore, to calculate and readminister radioiodine activity needed to achieve aimed radiation dose. Our data showed that the mean effective $^{131}I$ half-life for Graves' disease is 5.3 days(S.D=0.88) and mean biologic half-life is 21 days, range 9.5-67.2 days. The mean admininistered activity and the mean values of absorbed doses were 532 MBq(S.D.=254), 112 Gy (S.D.=50.9), respectively. The mean activity needed to achieve aimed radiation dose were 51MBq and marked differences of $^{131}I$ thyroidal uptake between tracer and therapy ocurred in our study. We are sure that the dose calculation method that uses 5 days thyroidal $^{131}I$ uptake measurements after tracer and therapy dose, provides sufficient data about the effective half-life and absorbed dose of $^{131}I$ in the thyroid and predict the effectiveness of $^{131}I$ treatment in Graves' hyperthyroidism.

  • PDF

The Follow Up Results of Residual Spinoglenoid Ganglion Cyst after Arthroscopic Decompression and Superior Labral Repair - Cases Report - (극관절와 결절성 낭포의 관절경적 감압술 및 상부관절와순 봉합술 후 잔존 낭포의 경과 - 증례 보고 -)

  • Sung, Chang-Meen;Lee, Sang-Hyuk;Park, Hyung-Bin
    • Clinics in Shoulder and Elbow
    • /
    • v.13 no.1
    • /
    • pp.111-116
    • /
    • 2010
  • Purpose: There are many known treatment modalities for spinoglenoid ganglion cyst accompanied by suprascapular nerve palsy. However, to the author's knowledge, there is no report on the follow-up outcomes focused on remnant cysts. Materials and Methods: Six (n=6) patients with spinoglenoid ganglion cyst accompanied by suprascapular nerve palsy, with a mean follow-up of 15 months (12-23months) following arthroscopic cyst decompression and superior labral repair, were enrolled. Residual cyst was investigated by ultrasonography and MRI. Results: Immediate postoperative ultrasonography revealed complete remission of ganglion cyst in one patient and reduced ganglion cyst size in five patients. Three-month follow-up ultrasonography showed spontaneous complete remission of the residual cysts in all patients. No recurrence on MRI was seen at one-year follow-up. Conclusion: Residual spinoglenoid ganglion cyst remaining after arthroscopic decompression and superior labral repair tends to resolve spontaneously within 3 months of surgery.

Correlations of Lumbar and Femoral Bone Mineral Densities with Calcaneal Speed of Sound in Osteoporotic Woman (골다공증 여성에서 요추골 밑 대퇴골 부위의 골밀도와 종골 음속 사이의 상관관계)

  • Lee, Kang-Il;Choi, Min-Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.28 no.6
    • /
    • pp.542-547
    • /
    • 2009
  • In this in vivo study, correlations of lumbar and femoral bone mineral densities (BMDs) with calcaneal speed of sound (SOS) were investigated in 36 osteoporotic women. Areal BMDs of the L2-L4 lumbar spine and the right femoral neck were measured by using dual energy X-ray absorptiometry (DEXA). SOS of the right calcaneus was measured by using ultrasound bone densitometry. Pearson's correlation coefficient (r) and level of significance (p) were used to evaluate the correlations between measurements. Lumbar BMD was highly correlated with femoral BMD (r=0.81). Lumbar and femoral BMDs exhibited similar comparable negative correlations with age (r=-0.52 and r=-0.55). A moderate negative correlation was found between calcaneal SOS and age (r=-0.45). Calcaneal SOS was significantly correlated with lumbar and femoral BMDs, with a higher correlation with femoral BMD rather than with lumbar BMD (r=0.54 and r=0.62). However, calcaneal SOS may not be an optimum index for the estimation of BMD of the most important fracture sites, such as the lumbar and the femur, because it showed lower correlations with lumbar and femoral BMDs compared to that with calcaneal BMD. Therefore, the development of a quantitative ultrasound technology for the direct measurement of acoustic properties at the lumbar and the femur is required to estimate BMD of these sites more accurately.

Phonophoretic Delivery of Piroxicam (초음파를 이용한 피록시캄의 경피흡수)

  • Chung, Kyu-Ho;Kim, Young-Il;Yang, Jae-Heon
    • Journal of Pharmaceutical Investigation
    • /
    • v.32 no.4
    • /
    • pp.259-265
    • /
    • 2002
  • Piroxicam is one of the NSAID, which is used in the systemic and topical treatment of a variety of inflammatory conditions. Conventionally, for topical use, the drug is formulated in gel. We designed an phonophoretic drug delivery system to investigate the piroxicam permeability and the influence of ultrasound application (continuous mode, pulsed mode), frequency (1.0 MHz, 3.0 MHz) and intensity $(1.0\;w/cm^2,\;1.5\;w/cm^2,\;2.0\;w/cm^2)$ with 0.5% piroxicam gel. Per cutaneous absorption studies were performed in vitro models to determine the rate of drug absorption via the skin. Permeation study using hairless mouse skin was performed at $37^{\circ}C$ using buffered saline (pH 7.4, 10% propylene glycol solution) as the receptor solution. Anti-inflammatory activity was determined using carrageenan-induced foot edema model in rat. A pronounced effect of ultrasound on the skin absorption of the piroxicam was observed at all ultrasound energy level studied. Ultrasound was carried out for 10 hr. The highest permeation was observed at intensity of $2.0\;w/cm^2$, frequency of 1.0 MHz and continuous output. The inclusion of phonophoresis was found to improve significantly the skin permeation in vitro and the anti-inflammatory activity in vivo.

Improvement of Properties in Solid Polymer Electrolyte Using New Preparation Method (새로운 막 제조 방법에 의한 고분자 전해질막의 특성 향상)

  • Kim, Tae-Hee;Lee, Jung-Hun;Park, Kwon-Pil
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.17 no.3
    • /
    • pp.331-337
    • /
    • 2006
  • 높은 이온전도도와 충분한 기계적 강도, 전해질 누수가 적은 새로운 형태의 고분자 전해질막(pore-gel SPE)을 연구 개발하였다. 다공성 PVDF-HFP 고분자막의 기공 내에 전해질 용액을 흡수시킨 후 막 내에서 젤화를 진행시켰다. 전해질 용액은 2:2:1의 비를 갖는 PC/EC/DMA에 1M SA(Salicylic acid)를 용해하고 여기에 고분자막을 용해시킬 수 있는 아세톤을 첨가하였다. 초음파를 이용함으로써 고분자막의 용액 흡수율을 증가시키고 또 고분자막에서 젤화를 촉진 시킬 수 있었다. 이렇게 젤화한 막의 이온전도도는 젤화 전 막보다 $1{\sim}2.2$ 배 향상되었고, 인장강도는 gel-type SPE 보다 40 배 증가하였으며, 전해질 누수실험결과 hybrid-type SPE는 13%의 누수를 보였으나 본 연구의 막(pore-gel SPE)은 6%로 감소함을 보였다.

CZTS 태양전지 제작을 위한 열분해법 나노 파티클 합성

  • Lee, Su-Ho;Seo, Mun-Su;Hong, Byeong-Yu;Park, Yong-Seop;Lee, Jae-Hyeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.321.1-321.1
    • /
    • 2013
  • 높은 광흡수 계수를 갖는 Cu(In,Ga)Se2(CIGS) 화합물 박막 소재는 고효율 태양전지 양산을 위해 가장 전도유망한 재료이나 상대적으로 매장량이 적은 In 및 Ga을 사용한다는 소재적 한계가 있다. Cu2ZnSnSe4(CZTSe) 혹은 Cu2ZnSnS4(CZTS)와 같은 Cu-Zn-Sn-Se계 화합물 반도체는 CIGS 내 희소원소인 In과 Ga이 범용원소인 Zn 및 Sn으로 대체된 소재로써 미래형 저가 태양전지 개발을 위해 활발히 연구되고 있는데, 그 화합물 조합에 따라 0.8eV부터 1.5eV까지의 에너지 밴드갭을 갖는 것으로 알려져 있다. 본 연구에서는 열분해법으로 CZTS 나노 입자를 합성하였다. 용매로 Oleylamine을 사용하였는데, $260{\sim}340^{\circ}C$의 온도 범위에서 5시간 30분 동안 CZTS 나노입자를 합성하였고, $300^{\circ}C$에서 5시간 30분~9시간까지 합성하였다. 헥산을 이용하여 원심분리기와 초음파세척기로 용매인 Oleylamine을 제거하였고, 진공오븐에서 건조된 CZTS 분말의 FE-SEM (Field Emission Scanning Electron Microscope), XRD (X-Ray Diffraction), EDS (Energy Dispersive Spectroscopy) 분석 등을 통해 합성온도에 따른 구조적, 화학적 조성 변화를 조사하였다.

  • PDF