• Title/Summary/Keyword: 초음파 파워

Search Result 49, Processing Time 0.113 seconds

Measurement of Acoustic Power Radiating from Each Channel of Linear Array Transducer for Diagnostic Ultrasonic Imaging System (초음파 영상 진단기용 선형 어레이 변환기의 채널별 음향파워 측정)

  • Yun Yong Hyeon;Jho Moon Jae;Kim Yong Tae;Lee Myoung Ho
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.351-352
    • /
    • 2004
  • 본 논문에서는 초음파 영상 진단기용 선형어레이 변환기를 장착할 수 있는 수조 와 128 채널의 스위칭 회로를 제작하여 변환기의 각 채널별 음향파워를 측정하였다. 실험은 128 채널 중 하나의 채널이 불량인 어레이 프로브를 대상으로 수행되었다. 측정 결과, 불량 채널의 음향 파워가 다른 채널에 비해 현저히 작게 나타남을 확인하였다.

  • PDF

Measurements of Acoustic Properties of Materials by Spectral Analysis of Ultrasonic Pulses (초음파 펄스의 주파수해석에 의한 재료의 음향특성 측정)

  • Ha, Kang-Lyeol;Kim, Moo-Joon;Lee, Jong-Kyu;Kim, Sung-Boo;Noriyoshi, Chubachi
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.40-47
    • /
    • 1995
  • A system for measurement of ultrasonic velocity, attenuation and complex modulus of materials by using the spectral analysis method of pulses has been constructed and its performances are estimated. The system has a mechanical scanning part of an acoustic microscope with a ZnO plane wave transducer of the resonant frequency of 85MHz. Ultrasonic velocity has been obtained by the intervals of maxima (or minima) on the power spectrum of a pulse train reflected from the surface and bottom of a specimen, and attenuation has been obtained by the power spectra of three pulses reflected from the surface and the bottom of a specimen and the surface of a standard specimen. The measured results for materials such as fused quartz, polyester show that the system has very high accuracy.

  • PDF

Thermal Sensitivity of the Bean Curd by Ultrasonic Irradiation (초음파 조사에 의한 두부의 열 감도)

  • 조문재;윤용현;부유천;김용태
    • The Journal of the Acoustical Society of Korea
    • /
    • v.23 no.7
    • /
    • pp.503-513
    • /
    • 2004
  • In this paper, the thermal sensitivity, i .e. the temperature rise per unit acoustic power, was newly defined and proposed as a performance parameter of a tissue mimicking material. Eatable tofu (bean curd) manufactured by a factory was selected as a sample material for the experiment. The temperature changes were measured not only with the variation of ultrasonic irradiation time, acoustic power, depth from the sample surface. and the distance from the source transducer while adjusting the frequency to 8 MHz but also with the variation of frequency while acoustic power. depth from the sample surface. and the distance from the source transducer keeping constant. As a result of a consideration for the transformation of the measured temperature changes to thermal sensitivities. the thermal sensitivity was found to be sufficient to use as a Performance parameter for tissue mimicking material. The tofu as a tissue mimicking material showed the maximum thermal sensitivity at 10 MHz, as is a significant result to imply the possibility that the thermal sensitivity of real human tissue strong1y depends on the frequency.

Performance Parameter of Tissue Mimicking Material measuring Ultrasonic Thermal Index (초음파 열지수 측정용 조직모사 물질의 성능계수)

  • Kim Yong Tae;Jho Moon Jae;Yun Yong Hyeon;Kim Ho Chul
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.369-370
    • /
    • 2004
  • 초음파의 조차에 의한 인체내부의 온도상승의 측도로 열지수(thermal index)가 사용되고 있으며, 이는 주파수 및 음향파워에 의존한다. 초음파 조사에 의한 인체내부의 온도상승을 평가하는데 사용되는 재료를 조직 모사 물질이라 한다. 본 논문아사는 단위 음향파워에 대한 온도 변화인 열 감도(thermal sensitivity)를 새로이 정의하였으며, 이 물리량으로 조직모사물질의 성능을 평가 할 수 있다는 것을 제안하고자 한다.

  • PDF

Thickness Measurement by Using Cepstrum Ultrasonic Signal Processing (켑스트럼 초음파 신호 처리를 이용한 두께 측정)

  • Choi, Young-Chul;Park, Jong-Sun;Yoon, Chan-Hoon;Choi, Heui-Joo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.34 no.4
    • /
    • pp.290-298
    • /
    • 2014
  • Ultrasonic thickness measurement is a non-destructive method to measure the local thickness of a solid element, based on the time taken for an ultrasound wave to return to the surface. When an element is very thin, it is difficult to measure thickness with the conventional ultrasonic thickness method. This is because the method measures the time delay by using the peak of a pulse, and the pulses overlap. To solve this problem, we propose a method for measuring thickness by using the power cepstrum and the minimum variance cepstrum. Because the cepstrums processing can divides the ultrasound into an impulse train and transfer function, where the period of the impulse train is the traversal time, the thickness can be measured exactly. To verify the proposed method, we performed experiments with steel and, acrylic plates of variable thickness. The conventional method is not able to estimate the thickness, because of the overlapping pulses. However, the cepstrum ultrasonic signal processing that divides a pulse into an impulse and a transfer function can measure the thickness exactly.

Ultrasound-Assisted Extraction of Canola Oil Using Supercritical Fluid Process (초음파가 적용된 초임계 유체 공정을 이용한 캐놀라오일 추출)

  • Hwang, Ah-Reum;Lim, Gio-Bin;Ryu, Jong-Hoon
    • KSBB Journal
    • /
    • v.25 no.5
    • /
    • pp.437-442
    • /
    • 2010
  • The objective of this study was to investigate the effect of ultrasound on the extraction of oil from canola seeds when supercritical carbon dioxide ($SCCO_2$) was used as an extraction solvent. The ultrasound-assisted $SCCO_2$ extraction were carried out while varying such operating parameters as particle size of crushed canola seed, flow rate of $SCCO_2$, aspect ratio of the extraction vessel, and ultrasound power. The extraction rate decreased with increasing particle size of samples, showing a maximun at a $CO_2$ flow rate of 6.2 L/min. Both the extraction rate and extraction yield increased with a decrease in the aspect ratio of the extraction vessel. For the ultrasoundassisted $SCCO_2$ extraction, the extraction yield was slightly increased when the $CO_2$ flow rate was below 6 mL/min with sample A and B.

Functional beamforming for high-resolution ultrasound imaging in the air with random sparse array transducer (고해상도 공기중 초음파 영상을 위한 기능성 빔형성법 적용)

  • Choon-Su Park
    • The Journal of the Acoustical Society of Korea
    • /
    • v.43 no.3
    • /
    • pp.361-367
    • /
    • 2024
  • Ultrasound in the air is widely used in industry as a measurement technique to prevent abnormalities in the machinery. Recently, the use of airborne ultrasound imaging techniques, which can find the location of abnormalities using an array transducers, is increasing. A beamforming method that uses the phase difference for each sensor is used to visualize the location of the ultrasonic sound source. We exploit a random sparse ultrasonic array and obtain beamforming power distribution on the source in a certain distance away from the array. Conventional beamforming methods inevitably have limited spatial resolution depending on the number of sensors used and the aperture size. A high-resolution ultrasound imaging technique was implemented by applying functional beamforming as a method to overcome the geometric constraints of the array. The functional beamforming method can be expressed as a generalized beam forming method mathematically, and has the advantage of being able to obtain high-resolution imaging by reducing main-lobe width and side lobes. As a result of observation through computer simulation, it was verified that the resolution of the ultrasonic source in the air was successfully increased by functional beamforming using the ultrasonic sparse array.

Diagnosis of Micro-Calcified Lesions of Breast Tissue Phantoms Using Acoustic Resonance Coupled with Power Doppler (공명현상과 파워도플러를 이용한 유방조직 팬텀의 미세 석회화 병변 진단)

  • Kim, Jeong-Koo;Ha, Myeung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.2
    • /
    • pp.80-86
    • /
    • 2008
  • Breast ultrasound has many advantages over mammography but suffers from a shortcoming of being not suitable in detecting microcalcification. We studied on a method based on acoustic resonance and power Doppler to detect calcification of breast tissue using a typical 7.5 MHz linear probe used in breast ultrasound examination. We first constructed a breast tissue phantom made of gelatin and then observed calcified legions as external vibrations varied. Calcification injected to the breast tissue phantom being resonated different from the surrounding medium, and its acoustic resonance driven by external vibrations was visualized by differences for color brightness and area in ROI of power doppler. In low frequency regions, the acoustic resonance almost not appeared and showed a plateau in $300{\sim}600\;Hz$ and the color vanished as the frequency further increased.