• Title/Summary/Keyword: 초음파 파라미터

Search Result 111, Processing Time 0.023 seconds

Fracture Behavior Analysis in CFRP Specimens by Acoustic Emission and Ultrasonic Test (음향방출 및 초음파시험을 이용한 CFRP 시험편의 파괴 거동 해석)

  • Ahn, Seok-Hwan;Nam, Ki-Woo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.21 no.3
    • /
    • pp.251-260
    • /
    • 2001
  • Damage Profess of CFRP laminates under monotonic tensile test was characterized by the correlation between Acoustic Emission(AE) and Ultrasonic Test(UT). The amplitude distribution of AE signal from a specimens is an aid to the determination of the extent of the different fracture mechanism such as matrix crack, debonding, fiber pullout and fiber fracture as load is increased. In addtion, the characteristics of ultrasonic amplitude attenuation are useful lot analysis of the different type of fracture mechanism. Different orientation of carbon fiber reinforced plastic specimens were used to investigate the AE amplitude range and ultrasonic amplitude attenuation. Finally, loading-unloading tests were carried out to check Felicity effect. During the tests, ultrasonic amplitude attenuation was investigated at the same time and compared with AE parameters. The result showed that two parameters of both AE and UT could be effectively used for analysis of fracture mechanism in CFRP laminates.

  • PDF

Effects of Moisture Content in Concrete on Diffuse Ultrasound (확산초음파의 콘크리트 함수율에 대한 의존성)

  • Ahn, Eunjong;Shin, Myoungsu
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.1
    • /
    • pp.142-147
    • /
    • 2020
  • This study investigates the effects of moisture content on diffuse ultrasound to be applied for the evaluation of micro-structural damage in concrete subjected to various environmental conditions. We monitored diffuse wave parameters for concrete samples in process of water saturation for 5 days. Dried samples were immersed in a water bath, and the change of moisture content in concrete were estimated by measuring the change of mass. For the diffuse wave analysis, a frequency range of 500 kHz, which represents a scattering regime of ultrasound in concrete, was selected. The test results reveal that the ultrasonic diffusivity slightly changed, and the ultrasonic dissipation significantly increased by approximately 120% in the process of water saturation. Therefore, the moisture content in concrete should be considered for the evaluation of micro-structural damage using diffuse wave techniques.

Application of Non-linear Acoustic Effect for Evaluation of Degradation of 2.25Cr-1Mo Steel (2.25Cr-1Mo 강의 열화도 평가를 위한 비선형 음향효과 응용법)

  • Choi, Y.H.;Jhang, K.Y.;Park, I.K.;Kim, H.M.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.22 no.2
    • /
    • pp.170-176
    • /
    • 2002
  • Nonlinear acoustic effect has been considered as an effective tool for the evaluation of material degradation. In this paper, the applicability of nonlinear acoustic effect to the evaluation of degraded 2.25Cr-1Mo steel is investigated. Firstly, artificial aging was performed to simulate the microstructural degradation in 2.25Cr-1Mo steel arising from long time exposure at $540^{\circ}C$. Secondly, ultrasonic nonlinear parameter was quantitatively measured by bi-spectrum and power spectrum. Nonlinear acoustic parameter from bi-spectrum was found to be clearly sensitive to the aging time.

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.

Retrospective Analysis of Cytopathology using Gray Level Co-occurrence Matrix Algorithm for Thyroid Malignant Nodules in the Ultrasound Imaging (갑상샘 악성결절의 초음파영상에서 GLCM 알고리즘을 이용한 세포병리 진단의 후향적 분석)

  • Kim, Yeong-Ju;Lee, Jin-Soo;Kang, Se-Sik;Kim, Changsoo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.237-243
    • /
    • 2017
  • This study evaluated the applicability of computer-aided diagnosis by retrospective analysis of GLCM algorithm based on cytopathological diagnosis of normal and malignant nodules in thyroid ultrasound images. In the experiment, the recognition rate and ROC curve of thyroid malignant nodule were analyzed using 6 parameters of GLCM algorithm. Experimental results showed 97% energy, 93% contrast, 92% correlation, 92% homogeneity, 100% entropy and 100% variance. Statistical analysis showed that the area under the curve of each parameter was more than 0.947 (p = 0.001) in the ROC curve, which was significant in the recognition of thyroid malignant nodules. In the GLCM, the cut-off value of each parameter can be used to predict the disease through analysis of quantitative computer-aided diagnosis.

Feasibility Study on Ultrasonic Velocity for Evaluation of Microstructure and Quality of Cast Iron (초음파 속도 측정에 의한 주철의 미세구조 및 품질평가 가능성 검토)

  • Choi, C.Y.;Hyun, C.Y.;Byeon, Jai-Won
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.32 no.2
    • /
    • pp.155-161
    • /
    • 2012
  • It was attempted to evaluate the microstructure and quality of various types of cast iron by ultrasonic velocity measurement. Three types of commercial gray cast iron and ductile cast iron were used for this investigation, respectively. One type of the ductile cast iron was heat-treated as a function of annealing time to produce different microstructure. Ultrasonic velocity measurement, microstructural analysis (pearlite area fraction, graphite length and nodularity), and hardness measurement were performed to find empirical correlations among these parameters. Ultrasonic velocity of ductile cast iron was markedly faster than that of gray cast iron. Ultrasonic velocity decreased with the decrease of fraction of pearlite structure. As a quality monitoring parameter of cast iron, potential of ultrasonic velocity was suggested.

A Study on Position Control of Ultrasonic Motor Using Variable Structure Control System (가변구조 제어를 이용한 초음파 전동기의 위치제어에 관한 연구)

  • Hong, Soon-Il;Kim, Hong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.546-548
    • /
    • 1998
  • 초음파는 초음파 가공기나 초음파 세척기 등에 많이 이용되고 최근 액추에트로서 초음파 전동기가 주목을 받고 있다. 압전 혹은 자기비틀림 효과를 이용하여 얻는 초음파 진동기는 전기-기계 변환효율이 다른 수단에 비하여 매우 높으므로 이것을 이용하여 얻는 초음파 진동은 왕복운동에서 직선 혹은 회전운동으로 변환시키는 연구가 행해지고 있다. 본 연구에서는 진행파 방식의 초음파 전동기를 중심으로 그 회전 원리를 이해하고 모델링 하였다. 외란에 대하여 강인한 제어방식으로 알려져 있는 가변구조제어의 이론을 이해고 회전형 진행파 방식의 초음파 전동기를 이용한 가변구조, 제어에 의한 서보계를 설계한다. 이때 제어방법은 속도패턴을 미리 정하여 두고 그 패턴에 따라 슬라이딩 모드를 사용하여 속도를 제어하여 위치를 제어하는 것이다. 초음파 전동기의 가변구조제어에 의한 위치제어를 컴퓨터 시뮬레이션으로 검토하고 제어 파라미터를 결정하였다. 그리고 인터페이스 보드를 제작하고 컴퓨터와 전동기를 접속하여 실제 제어 알고리즘을 이용하여 초음파 전동기의 제어 실험을 행하였다.

  • PDF

Image Analysis of Computer Aided Diagnosis using Gray Level Co-occurrence Matrix in the Ultrasonography for BPH (전립선비대증 초음파 영상에서 GLCM을 이용한 컴퓨터보조진단의 영상분석)

  • Cho, Jin-Young;Kim, Chang-Soo;Kang, Se-Sik;Ko, Seong-Jin;Ye, Soo-Young
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.191-192
    • /
    • 2015
  • 전립선비대증(Benign Prostatic Hyperplasia, BPH)은 전립선조직중에 이행구역의 결절성증식과 요도 주위의 과증식(Hyperplasia)이 특징이다. 경직장초음파(TRUS: transrectal ultrasonography)검사를 이용한 진단에 있어 정상조직과 비대되어 있는 조직의 영상 차이를 비교하고 수량화로 나타내었다, 영상분석에는 GLCM 통계적 파라미터 중에서 Autocorrelation, Cluster Prominence, Entropy, Sum average를 4개의 파라미터에서 병변 인식이 가능하였고 인식 효율은 92-98%가 나왔다. 전립선비대증식에 대한 초음파영상을 가지고 컴퓨터영상처리분석을 제안하여 진단시 참고 자료가 될 것으로 기대한다.

  • PDF

Image Analysis of Diffuse Liver Disease using Computer-Adided Diagnosis in the Liver US Image (간 초음파영상에서 컴퓨터보조진단을 이용한 미만성 간질환의 영상분석)

  • Lee, Jinsoo;Kim, Changsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.227-234
    • /
    • 2015
  • In this paper, we studied possibility about application for CAD on diffuse liver disease through pixel texture analysis parameters(average gray level, skewness, entropy) which based statistical property brightness histogram and image analysis using brightness difference liver and kidney parenchyma. The experiment was set by ROI ($50{\times}50$ pixels) on liver ultrasound images.(non specific, fatty liver, liver cirrhosis) then, evaluated disease recognition rates using 4 types pixel texture analysis parameters and brightness gap liver and kidney parenchyma. As a results, disease recognition rates which contained average brightness, skewness, uniformity, entropy was scored 100%~96%, they were high. In brightness gap between liver and kidney parenchyma, non specific was $-1.129{\pm}12.410$ fatty liver was $33.182{\pm}11.826$, these were shown significantly difference, but liver cirrhosis was $-1.668{\pm}10.081$, that was somewhat small difference with non specific case. Consequently, pixel texture analysis parameter which scored high disease recognition rates and CAD which used brightness difference of parenchyma are very useful for detecting diffuse liver disease as well as these are possible to use clinical technique and minimize reading miss. Also, it helps to suggest correct diagnose and treatment.

Quantitative assessment of Endorectal Ultrasonography by using GLCM Algorithm (GLCM알고리즘을 이용한 경직장 초음파 영상의 정량적 평가)

  • Nho, Da-Jung;Kang, Min-Ji;Kim, Yoo-Kyeong;Seo, Ah-Reum;Lee, In-Ho;Jeong, Hee-Seong;Jo, Jin-Yeong;Ko, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.383-387
    • /
    • 2015
  • Bowel and rectal diseases are on the increase by irregular life and westernized eating habits of modern people, especially rectal cancer, which accounts for 50% of the entire colon cancer. For the initial rectal cancer, because there is no portion projecting on the surface, if not see inside the tissue with ultrasound, you make an errors that misdiagnosis as rectal abscess. However there is a need for more accurate diagnosis, because it is sometimes difficult to distinguish abscess from rectal cancer depending on staging, in spite of the ultrasonic diagnosis. Therefore, this study was performed quantitative analysis by using a computer algorithm for rectal cancer and abscess image. Each of 20 cases about normal, abscess and cancer by setting analysis region ($50{\times}50$ pixels) applies to GLCM algorithm and Autocorrelation, Max probability, Sum average, Sum variance in each image were analyzed by comparing the 4 single parameter. Consequently, The high lesion detection efficiency was presented 100% by the 3 parameter of Autocorrelation, Max probability, Sum variance and the parameter of Sum average presents 95% in cancer, more than 90% in abscess. Those parameters are valuable in distinction standard about normal, cancer and abscess in rectum. It is sufficient availability as a computer assisted diagnosis system depended on clinical using.

  • PDF