• Title/Summary/Keyword: 초음파 젤

Search Result 22, Processing Time 0.023 seconds

Usability Evaluation of Gel Pad Materials for Superficial Structures used in Musculoskeletal Ultrasonography (근골격계 초음파검사에 사용되는 표재성 검사용 젤 패드 물질의 유용성 평가)

  • Han, Mi-Ran;Kwak, Jong-Gil;Song, Jong-Nam;Jang, Seong-Ju;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.6
    • /
    • pp.899-909
    • /
    • 2021
  • In Musculoskeletal ultrasound examination, a linear transducer (12-5 MHz) with a contact surface length of 6 cm, which is commonly distributed in medical institutions, does not contact with bent fingers and wrist depressions only by using a conventional liquid ultrasound gel, which causes image loss. In order to solve this image loss, the use of commercially available Water gel pad is increasing. However, it is a disposable medical product. Repeated use is prohibited and expensive. In this study, in order to reduce the economic burden caused by the use of the commercialized Water gel Pad, we searched for water-soluble food thickener powder that can be easily purchased around our lives and manufactured Gel pads. Among them, kappa-Carrageenan Gel Pad, iota-Carrageenan Gel Pad, and Agar-Agar Gel Pad satisfied the evaluation criteria without artifacts in image evaluation using the N-365 Multipurpose Phantom. Also, the price to purchase the food thickener powder was about 38 times cheaper than the existing commercialized Water gel pad. As a result, if you use the food thickener powder such as kappa-Carrageenan, iota-Carrageenan and Agar-Agar to make solidified elastic Gel pad without a cover instead of the commercially available expensive disposable Water gel pad, the convenience and usefulness of use are improved. It is judged that the manufactured Gel pads can contribute well to the role of efficient ultrasound propagation medium.

Research on the Effectiveness of Diagnostic Ultrasound Transmission Media (초음파진단 시 전파매질의 유용성)

  • Lee, Hye-Nam
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.1
    • /
    • pp.324-330
    • /
    • 2015
  • When diagnostic ultrasounds are used, an ultrasonic transmission media is used to effectively transmit the ultrasonic energy. Types of ingredients of polymer hydro gel, emulsion, and oil gel were compared with commercialized products by measuring characteristics of ultrasonic transmission media such as skin lubricity, skin moisturizing, and dryness speed which were contained in each different media. The mean friction coefficient measured to investigate skin lubricity showed high in the agent containing a large amount of oil, whereas the mean friction coefficient of the low viscosity emulsion did not show a significant difference with that of the polymer hydro gel. The moisture evaporation measured to investigate the dryness speed of the agent showed highest in polymer hydro gel. This showed that the larger amount of oil it had, the less moisture evaporation occurred. For skin moisture measured to investigate moisturizing characteristics of skin, low viscosity emulsion showed high in moisture content, whereas it showed slowest reduction in moisture content. As a type of emulsion appropriately containing water and oil is superior in skin moisturizing and skin tenderness, it is expected to serve as a dosage form of new ultrasonic transmission media.

Prediction of the Rheological Property of Protein Food Gel System by Using Ultrasonic Wave (초음파를 이용한 단백질 식품젤의 물성변화의 예측에 관한 연구)

  • Yoon, Won-Byung;Kim, Byung-Yong;Kim, Myung-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.632-636
    • /
    • 1993
  • Gel strength of fish protein at various processing conditions such as heating temperature, heating time and salt content was determined by using compressive stress and residual delay time of ultrasonic wave. The compressive stress, interpreted as indicating the relative gel strength, was increased with increasing the heating temperature and heating time, and with decreasing the salt content, while the delay time of ultrasonic wave reduced, indicating that the gel strength and the delay time are inverse proportion. The result of the multiple regression analysis with factorial design showed that the model equation consisted with delay time and processing condition variables gave the good prediction of the gel compressive stress which was coincided with compressive stress measured.

  • PDF

Thermal distribution change in polyvinyl alcohol gel caused by focused ultrasound (폴리비닐알코올 젤의 집속초음파에 의한 온도분포 변화)

  • Kim, Jungsoon;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.39 no.6
    • /
    • pp.576-584
    • /
    • 2020
  • In order to obtain basic information for using polyvinyl alcohol (PVA) gel as a tissue mimicking phantom for temperature visualization, the temperature change characteristics due to the focused ultrasound were examined for different concentration of PVA. To obtain the basic acoustic characteristics, the speed of sound, the attenuation coefficient, and the density depending on the PVA concentration were measured, and the thermodynamic characteristics, such as thermal conductivity and heat capacity, were measured. The range of temperature rising in the vicinity of the focal point due to the focused ultrasound was observed using a thermochromic film that changes color at 30 degree or more, and the discolored area was obtained by image processing of the recorded image. As the concentration of PVA increases in the given range of 2 wt% ~ 16 wt%, the area that rises above 30 degree inside the gel increases linearly. It is confirmed that the discolored area increases as the power applied to the focused ultrasonic transducer increases. These results showed good agreement with the simulation results using the finite element method.

Convergence Formulation studies of Diagnostic Ultrasound Transmission Media:focusing on the manufacturing costs and rheology (초음파전파매개물의 융복합 제형 연구 :제조비용, 윤활성에 대하여)

  • Lee, Hye-Nam;Park, Mi-Soon;Park, Yeon-Hwa
    • Journal of Digital Convergence
    • /
    • v.13 no.8
    • /
    • pp.369-374
    • /
    • 2015
  • In this study, by combining a unique purpose and additional aspects of ultrasonic transmission media, a development potential on a new ultrasonic transmission media was sought. The rheological characteristics and the manufacturing cost for each manufactured formulation were compared and analysed with ready-made. An ultrasonic transmission media is to have different functional characteristics according to the following formulation, it was the best in rheological value, low viscosity emulsion with the oil gel. Polymer hydro gel is can be manufactured at low cost compared to other formulations. Emulsion which shows a sharp viscosity difference according to the components of oil and water had a big difference in manufacturing cost. This study can be utilized as the fundamental data on the ultrasound transmission media equipped with expertise in various areas of ultrasound.

지혜 깊어지는 건강_건강검진 이야기: 간편한 초음파검사 결과도 바로 확인하다

  • Lee, Eun-Jeong
    • 건강소식
    • /
    • v.35 no.7
    • /
    • pp.16-17
    • /
    • 2011
  • 검사 테이블로 바로 누워 해당 검사 부위에 투명한 젤을 바르고 그 위에 초음파 변환기를 대면 모니터에 실시간 이미지가 떠오르고 이를 관찰하면 된다. 짧게는 10분, 길게는 30분이면 충분하다. 이처럼 초음파검사는 간편할 뿐만 아니라, 별다른 고통 없이 여러 질병을 진단할 수 있다.

  • PDF

A Study on the Effectiveness of Hand Sanitizer compared to Conventional Ultrasound Gel during Ultrasound Examination (초음파검사 시 기존 초음파젤과 비교한 손소독제의 유용성 연구)

  • Sun-Youl Seo;Jin-Ok Lee;Young-Ran Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.957-964
    • /
    • 2023
  • This study focused on hand sanitizer as a medium that can replace ultrasonic gel, which is vulnerable to contamination by bacteria that reside on the hand. Hand sanitizer produces a strong sterilization effect from germs resident on the hands through different sterilization principles depending on the ingredients. Select products of gel type, cream type, and foam type, except for liquid type with low viscosity, and ultrasonically apply one 62% ethanol gel type and one cream type, one benzalkonium chloride 0.066% cream type and one foam type, respectively. Using ATS-539 as a medium, image evaluation was performed on the axial and lateral resolution and penetration depth, and the presence or absence of an air layer between the probe and the phantom. As a result, in the evaluation of the axial and lateral resolution and the depth of penetration, all four experimental groups met the evaluation criteria. However, in the case of the foam type, although it was suitable for the evaluation criteria of resolution and penetration depth, dark shadows appeared on both sides except for the center of observation during image evaluation. Through this experiment, it was possible to confirm the possibility that the remaining three types of hand sanitizers except the foam type could replace the ultrasonic gel.

A Study on the Effectiveness of Diagnostic Ultrasound Transmission Media (초음파진단시 초음파 전파매질의 유용성에 관한 연구)

  • Lee, Hye Nam;Lim, Cheong-Hwan
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2014.11a
    • /
    • pp.187-188
    • /
    • 2014
  • 초음파 전파 매개물은 초음파의 손실 없는 투과력을 위한 1차적인 목적 이외에 피부위에서 탐촉소자의 부드러운 이동을 위한 부가적인 목적이 있다. 본 연구는 제형이 다른 진단초음파 전파매개물이 갖는 피부 윤활성, 피부 보습성, 건조속도 등의 초음파 매개물의 특징을 측정하고 비교하였다. 마찰계수는 점도가 높을수록 높았으며 제제의 건조속도는 고분자 수화젤이 가장 높았다. 오일 함유량이 많을수록 수분증발이 나타나지 않았다. 피부수분함량에서는 저점도 에멀전이 높은 수분함량을 나타냈으며 수분함량 감소 정도가 가장 완만히 나타났다. 오일성분을 적절히 사용한 에멀전 형태의 초음파 전파매개물은 피부 보습효과, 피부 유연작용의 피부 건강측면과 피부-탐촉소자간의 피부 윤활성면에서 효과적인 제형임을 알 수 있었다.

  • PDF

The Effect of Indomethacin Phonophoresis on the Relief of Temporomandibular Joint Pain (인도메타신을 이용한 음파삼투요법에 의한 측두하악관절부 동통의 완화효과)

  • Soon-Moon Shin;Jae-Kap Choi,
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.377-383
    • /
    • 1995
  • 이 연구의 목적은 측두하악관절통에 있어서 인도메타신 포노포레시스의 동통완화효과를 평가하기 위한 것이다. 측두하악관절통을 가진 20명의 환자들이 이 연구에 참여했다. 10명은 인도메타신을 이용하여 초음파치료를 받았고 다른 10명은 순수 초음파 치료용 젤을 이용하여 초음파 치료를 받았다. 동통완화효과를 평가하기 위하여 치료전과 치료후에 유추지수와 압력통각역치를 이중맹검법으로 평가하였다. 실험결과는 다음과 같다. 인도메다신을 이용하여 초음파 치료를 받은 군은 유추지수와 압력통각역치에서 다 유의한 동통의 감소를 보였다. 반면에 대조군에서는 치료후에 유추지수와 압력통각역치에서 동통의 감소를 보였지만 통계적으로 유의하지 않았다. 이 결과는 측두하악관절통에 있어서 단순한 초음파 치료보다 포노포레시스가 더 효과적이라는 것을 의미한다.

  • PDF

Evaluation of Washing Method for Sterilization of Gel Container for Ultrasound Inspection (초음파검사용 젤 용기의 제균을 위한 세척방법 평가)

  • Lee, Hee-Jeong;Lee, Suk-Jun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.241-247
    • /
    • 2018
  • The purpose of this study was to compare the ultrasound gel container washing methods for the sterilization of contaminants and to find the useful methods for the prevention of infection caused by the ultrasonic gel containers. In this experiment, a 250 mL ultrasonic gel container was used, and the ultrasonic gel used was a non-sterile gel (ECO GEL 99, SeungWon Medical, Korea). In order to evaluate the degree of contamination, new 250 mL 15 containers were divided into 5 groups to perform five types of washing by no treatment, washing with water, washing with soap, washing with bottle cleaner and high disinfection level washing. After the washing process, filled the gel container with gel and after 2 weeks, the number of colonies in the gel container was sampled repeatedly twice in the same ultrasonic laboratory and compared before and after washing. As a result of among the five cleaning methods used in this study, 87.2% and 88.9% of the soapy water washing (p = 0.028) and high level washing (p = 0.027) showed significant bacterial reduction rates, respectively. Our findings conclusively an ultrasonic gel container cleaning method for removing contaminants has been found to be an effective sterilization method at a low cost with a soapy water cleaning method. Therefore, it is expected that it will be helpful to prevent the infection caused by the ultrasonic gel container by suggesting the sterilization cleaning method that is practically useful in this study.