• Title/Summary/Keyword: 초음파 제거 효율

Search Result 79, Processing Time 0.028 seconds

The Effect of Reaction Temperature and Volume in the Sonolysis of 1,4-Dioxane (1,4-Dioxane의 초음파 처리시 반응 온도와 부칙의 영향)

  • Son, Hyun-Seok;Choi, Seok-Bong;Eakalak, Khan;Zoh, Kyung-Duk
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.10
    • /
    • pp.1114-1122
    • /
    • 2005
  • This research investigates the effects of sonication mode, reaction temperature and volume on sonolysis of 1,4-dioxane in order to increase the degradation efficiency and kinetics. The degradation efficiency in case with pulse mode was about 10 % higher than that in case with continuous mode. The degradation profiles in both cases, which were performed without the control of reaction temperature and in 1000 mL, were composed of three steps. However, 1,4-D was mainly degraded in the initiation step as the first portion and the acceleration step as the second portion. The initial step agreed with zero-order expression well, while the acceleration step could be fitted with pseudo 1st-order expression. The kinetic model in case with $5^{\circ}C$ and 300 mL conformed to pseudo 1st-order, while that in cases with $10^{\circ}C$ to $40^{\circ}C$ agreed with zero-order expression. The degradation efficiency and profile of 1,4-D in the experiment with $20^{\circ}C$ and 300 mL was higher and simpler than that in case with $20^{\circ}C$ and 1000 mL. The reaction temperature and volume influence bubble intensity, which was produced in sonication. The increase of bubble intensity induced to augment the production of OH radical in sonication.

Appendix Extraction from Ultrasound Image using ART2 (ART2 알고리즘을 이용한 초음파 영상에서의 충수 추출)

  • Kim, Kwang Baek
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.19 no.11
    • /
    • pp.2540-2545
    • /
    • 2015
  • In this paper, we propose a novel method to extract appendix from ultrasound image automatically to avoid such subjectivity issue. In the process, we apply a series of image processing algorithms such as Ends_in search stretching for emphasizing brightness contrast and binarization, region labelling, and cubic spline interpolation for extracting lower bound fasicia line that is the base of extracting the appendix. Knowing that the appendix is located at the lower organ area below the bottom fascia line, we conduct a series of image processing techniques to find the fascia line correctly. And then we apply ART2 algorithm to the organ area in order to extract appendix accurately. Through experiment, the effectiveness of the proposed method is verified based on the field experts' evaluations.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

Ultrasonic Spray Nozzle System with Piezoelectric Device for Chemicals Dispersion (압전체를 이용한 약품 분사용 초음파 분사 노즐 시스템)

  • 고재석;김용현;김형수;조순행;최승철
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.10 no.4
    • /
    • pp.65-71
    • /
    • 2003
  • A new type of ultrasonic spray nozzle was fabricated employing a piezoelectric device. The spray nozzle was designed to disperse chemicals in a water treatment mixing tank. The piezoelectric properties in ultrasonic spray nozzles were optimized to improve the dispersion of chemicals. The piezoelectrics were packaged in an aluminum case with silicone resin for the aqueous solution proof packaging. Chemicals were dispersed with high efficiency and the chemicals consumption was reduced by the ultrasonic fine particle spraying. The concentration of Escherichia coli in mixing tank was decreased remarkably using ultrasonic spray nozzle dispersion compared to the conventional methods.

  • PDF

Analysis of contamination characteristics of filter cloth in filter press by repeated dehydration of organic sludge and evaluation of ultrasonic cleaning application (유기성 슬러지 반복 탈수에 의한 필터프레스 여과포 오염 특성 분석 및 초음파 세척 적용 평가)

  • Eunju Kim;Cheol-Jin Jeong;Kyung Woo Kim;Tae Gyu Song;Seong Kuk Han
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.32 no.2
    • /
    • pp.15-25
    • /
    • 2024
  • In this study, the regeneration effect of pressurized water and ultrasonic cleaning was investigated for contaminated filter cloth from the sewage sludge filter press process. For this purpose, contaminated filter cloth was collected from a 3-ton sewage sludge hydrothermal carbon treatment filter press. First, the contamination characteristics were analyzed. According to the location of the filter cloth, air permeability and unit mass were measured, and compared with the values of a new filter cloth. Next, the results were mapped over the entire area to evaluate the contamination characteristics. Finally, pressure cleaning at 3 bar and ultrasound at frequencies of 34, 76, 120, and 168 kHz were performed on the contaminated filter cloth. In addition, the cleaning efficiency was evaluated by 3 levels of contamination degree. As a result, pore contamination occurred mainly at the bottom and both sides of the filter cloth, where the filter material was continuously injected and compressed. Surface contamination appeared evenly over the entire area. As a result of washing, air permeability increased by 1.3-3.1%p and contaminant removal was by 2.7-4.4% under pressure. In ultrasonic cleaning, air permeability increased by 12.5-61.5%p and contaminants were removed by 2.7-29.2%. In ultrasonic cleaning the lower the frequency, the higher air permeability and contaminant removal rate. Also, The higher pore contamination level, the better the air permeability improvement and contaminant removal.

Spent-GAC Regeneration Using Variable Frequency Sono-Fenton Oxidation (가변 주파수 Sono-Fenton 산화를 이용한 Spent-GAC 재생기술)

  • Joo, Soobin;Lee, Sangmin;Kim, Hyungjun;Shim, Intae;Kim, Heejin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.4
    • /
    • pp.449-458
    • /
    • 2023
  • As an adsorption technology for dissolved organic matter, the adsorption capacity of granular activated carbon, GAC, can be applied, but activated carbon whose adsorption capacity is significantly reduced by use is inevitably replaced or regenerated. However, due to the economics of replacement cost, thermal regeneration method is used commercially, but high energy cost and loss of activated carbon occur under high temperature conditions above 800℃. In this study, the Sono-Fenton method, a multi-oxidation technology that combines Fenton oxidation and ultrasonic oxidation, was applied to improve the regeneration efficiency of spent GAC used to treat dissolved organic matter in combined sewer overflows (CSOs), and the regeneration efficiency of spent GAC by oxidant and ultrasonic frequency was investigated. In the applied Sono-Fenton treatment, the highest regeneration efficiency of 68.5% was obtained under the regeneration conditions of Fe2+ 10 mmol/L, H2O2 concentration 1,000 mmol/L, ultrasonic treatment time of 120 min, and ultrasonic frequency of 40 kHz. And similar efficiency was also obtained at 750 kHz, while ultrasonic waves of other frequencies had poor regeneration efficiency, and the magnitude of frequency and GAC regeneration efficiency did not show a linear relationship. In the case of continuous operation of the GAC adsorption tower with CSOs prepared by diluting raw sewage, about 700 hours of operation without regeneration was possible, and as a result of applying one Sono-Fenton treatment, 40-70% CODcr removal efficiency was obtained during a total of 1,000 hours of GAC adsorption operation.

Regeneration Methods for Iron Powers in the Treatment of the Waste FeCl3 Etching Solution (엣칭용 염화철폐액의 처리에서 미반응철의 재생방법)

  • Park, Chan-Woo;Jeung, Woo-Won;Lee, Man-Ho
    • Applied Chemistry for Engineering
    • /
    • v.8 no.4
    • /
    • pp.595-601
    • /
    • 1997
  • The regeneration of the iron powders in the treatment of $FeCl_3$ etching solution containing nickel by ball-mill and ultrasonic treatments has been studied. When the unreacted iron powders were treated twice, the removal efficiency of nickel was 94.0% for the ball-mill treatment and 82.1% for the ultrasonic treatment. But the removal efficiency of nickel was 40.0% for the untreated iron powders. As the treatment time was increased, the particle size of iron powders was decreased for ball-mill treatment and almost not changed for ultrasonic treatment.

  • PDF

Removal Characteristics of Lead-contaminated Soil at Military Shooting Range by Using Soil Washing Process (토양세척공정을 이용한 군사격장 납 오염토양의 제거특성)

  • Ahn, Sung-Kyun;Kim, Chul;Lee, Joung-Man;Lee, Gang-Choon;Shon, Zang-Ho;Jung, Byung-Gil;Yoon, Tae-Kyung
    • Clean Technology
    • /
    • v.18 no.4
    • /
    • pp.390-397
    • /
    • 2012
  • Removal characteristics of lead-contaminated soil at the military shooting range located in the Changwon city were studied experimentally using soil washing process. As a washing solution, hydrogen chloride (HCl) concentrations of 0.001, 0.01, 0.1 and 0.2 N were used, and soil : solution ratios were 1 : 2, 1 : 3, 1 : 4, and 1 : 5. Particle diameter of contaminated soil of 4-0.075 mm, and washing period of 5, 10, 15, 20, 30, 60, and 120 min were used as operating parameters. The optimum concentration of HCl solution was 0.1 N (56.3% of Pb removal efficiency) with 15 minutes operation period in views of economics, and the optimum soil : solution ratio was determined as 1 g : 3 mL for 69.7% of Pb removal efficiency with 0.1 N HCl and 15 minutes washing period. As washing period increased, removal efficiency was increased until 20 min of the removal efficiency of 75.3%, and then almost stable. Pb removal efficiency in soil particle diameters of 0.075 mm or more was ranged from 77.0% to 82.0%, but it was decreased to 52.8% in diameter of less than 0.075 mm. Therefore, the optimum cut-off size of the soil particle diameter was found less than 0.075 mm. Combined HCl solution and ultrasonic washing method showed better removal efficiency compared to only water or HCl washing method for particle sizes above 0.075 mm.

Appendix Extraction of Abdomen Ultrasonographic Images Using Distance-based Fuzzy ART (거리 기반 퍼지 ART를 이용한 복부 초음파 영상에서의 충수 추출)

  • Choi, Sung-Su;Bae, Jun-Ho;Yang, Ji-Hyeon;Park, Seung-Ik;Kim, Kwang-Beak
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.94-96
    • /
    • 2013
  • 본 논문에서는 복부 초음파 영상에서 Ends_in Search Stretching 기법을 적용하여 명암 대비를 강조한 후, 이진화, 영역 레이블링 기법, 잡음 제거를 통해 근막을 추출하고, 근막 영역의 하단 경계선을 기준으로 Cubic Spline 보간법을 적용하여 복부 근육의 근막 하단 영역을 추출한다. 복부 초음파 영상에서 추출된 근막 하단 영역을 이용하여 근막 영역을 제거한 후, 거리 기반 퍼지 ART 알고리즘을 적용하여 충수 후보 영역을 추출한 다. 추출된 충수 후보 영역에 침식 연산과 영역 레이블링 기법을 적용하여 충수를 추출한다. 제안된 방법을 복부 초음파 영상을 대상으로 실험한 결과, 기존의 충수 추출 방법보다 객관적이고 효율적으로 충수와 소장의 명암도 차이를 구별할 수 있어 충수 영역이 이전의 방법 보다 비교적 정확히 추출되는 것을 영상의학과 관련 전문의를 통해 확인하였다.

  • PDF

Extracting Ganglion in Ultrasound Image using DBSCAN and FCM based 2-layer Clustering (DBSCAN과 FCM 기반 2-Layer 클러스터링을 이용한 초음파 영상에서의 결절종 추출)

  • Park, Tae-eun;Song, Jae-uk;Kim, Kwang-baek
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.10a
    • /
    • pp.186-188
    • /
    • 2021
  • 본 논문에서는 초음파 영상에서 DBSCAN(Density-based spatial clustering of applications with noise)과 FCM 클러스터링 기반 양자화 기법을 적용하여 결절종을 추출하는 방법을 제안한다. 본 논문에서는 초음파 영상 촬영 시 좌우 상단의 지방층 영역과 하단 영역의 명암도가 어두운 영역을 잡음 영역으로 설정한다. 그리고 초음파 영상에 퍼지스트레칭 기법을 적용하여 잡음 영역을 최대한 제거 한 후에 ROI 영역을 추출한다. 추출된 ROI 영역에서 밀도 분포를 분석하기 위하여 히스토그램을 분석한 후에 DBSCAN을 적용하여 초음파 영상에서 결절종 후보에 해당되는 명암도를 추출한다. 추출한 후보 명암도를 대상으로 FCM 클러스터링 기법을 적용한다. FCM을 적용하는 단계에서 결절종의 저에코 혹은 무에코의 특징을 이용하여 클러스터 중심 값이 가장 낮은 클러스터를 양자화 한 후에 라벨링 기법을 적용시켜 결절종의 후보 객체를 추출한다. 제안된 결절종 추출 방법의 성능을 분석하기 위해 전문의가 결절종 영역을 표기한 초음파 영상과 표기되지 않은 초음파 영상 120쌍을 대상으로 DBSCAN, FCM, 그리고 제안된 방법 간의 성능을 비교 분석하였다. 제안된 방법에서는 120개의 초음파 영상에서 106개 결절종 영역이 추출되었고 FCM 기법에서는 80개가 추출되었고 DBSCAN에서는 36개가 추출되었다. 따라서 제안된 방법이 결절종 추출에 효율적인 것을 확인하였다.

  • PDF