• Title/Summary/Keyword: 초음파 에너지

Search Result 320, Processing Time 0.026 seconds

Measurement of Crack Length by Ultrasonic Attenuation Coefficients on Interfaces of Al/Epoxy Bonded Dissimilar Materials (Al/Epoxy 이종재 접합 계면의 초음파 감쇠계수에 의한 균열길이의 측정)

  • Park, Sung-Il;Chung, Nam-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1109-1114
    • /
    • 2003
  • The initial crack often occurs on the bonded interface and it is the general cause of the interface fracture. It is very significant to establish the measurement method of interfacial crack by applying the ultrasonic technology into the interface of bonded dissimilar materials. In this paper, the interfacial crack length was measured by ultrasonic attenuation coefficient in the Al/Epoxy bonded dissimilar materials of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental and Ripling's equation measurement of compliance. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. From the experimental results, a measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

  • PDF

Object Avoiding and Tracking Method of Mobile Robot (이동로봇의 물체 회피 및 추적 방법)

  • Lee, Eun-Sun;Lee, Chan-Ho;Kim, Eun-Sil;Kim, Sang-Hoon
    • Proceedings of the Korean Information Science Society Conference
    • /
    • 2006.10b
    • /
    • pp.521-525
    • /
    • 2006
  • 본 논문에서는 초음파 및 적외선 센서와 무선 카메라를 장착한 소형 이동 로봇의 장애물 회피 및 물체 추적 방법을 제시한다. 장애물 회피를 위해서 제어부의 초음파 발생 신호의 귀환시간과 거리와의 관계 및 적외선 센서에서 측정한 아날로그신호와 거리와의 관계를 추출하여 이동 로봇과 물체와의 거리를 판단하여 로봇의 움직임을 제어하는데 사용한다. 물체 추적 모드에서는 첫째, 물체와 배경 및 유사잡음들과의 강인한 분리를 위하여 고유색상정보와 움직임 정보 등의 사전정보를 활용하였으며 둘째, 형태의 변화가 수반되는 경우에도 유연한 대처능력을 갖도록 하기 위해 영상의 영역분할 방법을 통해 모든 후보영역내의 물체의 존재를 확인하고 물체영역만을 추출하였다. 셋째, 물체 형태정보함수를 정의하고 해당함수를 형태의 보전 에너지로 활용하여 동일 물체의 대응문제를 효과적으로 해결하였다.

  • PDF

A Study on the Flow Characteristics of Emulsified Fuel by the Ultrasonic Energy in Tube (초음파 에너지로 제조한 유화연료의 관로 흐름 특성에 관한 연구)

  • Koh, Kyounghan;Lee, Seungjin;Lee, Byongo;Ryu, Jeongin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.11 s.242
    • /
    • pp.1248-1256
    • /
    • 2005
  • This study was undertaken to investigate the flow characteristics of emulsified fuel with the ultrasonic energy-adding system by using the chaotic method. Efffcts of water contents within emulsified fuel, flow rate and tube length with 5m in diameter from an emulsified chamber has been discussed on the strange attractor and power spectral density function. Five probe sensors were set up from 0.5 to 2.5m by length in 0.5m increments in the tube. In particular, the chaotic features of this system have been practically characterized in terms of chaotic statistics such as the power spectral density function and phase space portraits by resorting to the somewhat noble deterministic chaos theory. In the tube, the dominant frequency increased with increasing water contents and flow rate, but decreased a little with an increase in the length from the emulsified chamber.

Joining of Polymer Materials with Ultrasonic Welding (초음파 용접을 이용한 합성수지의 결합)

  • 이철구;정규창
    • Journal of Welding and Joining
    • /
    • v.16 no.2
    • /
    • pp.48-56
    • /
    • 1998
  • This study was performed to find the best bonding conditions by comparing mechanical properties in thermoplastic resin of polyethylene (PE) and polyamide (PA) adhesion. Following results were obtained from the tests with varying welding time and welding pressure. Satisfactory adhesion was executed in ultrasonic welding for the same materials of PE and PA. The best welding conditions were found to be welding time of 1 second, welding pressure of 250kPa for PE-PE weding, 2 second and 350kPa for PA-PA welding. Welding time and welding pressure end to increase with the increase of materials strength. Dissimilar materials were adhered when adhesion and ultrasonc welding were performed simultaneously. The observation of the structure of ultrasonic welding area with microscope showed differenticated structures between well adhered region and badly adhered region.

  • PDF

Measurement of Interfacial Crack Length by Ultrasonic Attenuation Coefficients on Adhesively Bonded Components (접착부재의 초음파 감쇠계수에 의한 계면균열 길이의 측정)

  • 정남용;박성일
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.130-137
    • /
    • 2004
  • The ultrasonic attenuation coefficients were measured by interfacial crack length in the adhesive components of double-cantilever beam(DCB). The energy release rate, G, was obtained by the experimental measurement of compliance. The numerical analysis by the boundary element method(BEM) and Ripling's equation was investigated. The experimental results represent that the relation between interfacial crack length for the ultrasonic attenuation coefficient and energy release rate is increased proportionally. A measurement method of the interfacial crack length by the ultrasonic attenuation coefficient was proposed and discussed.

Measurement of Crack Length by Ultrasonic Attenuation Coefficient (초음파 감쇠계수에 의한 균열길이의 측정)

  • Chung, Nam-Yong;Park, Sung-Il
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.28 no.4
    • /
    • pp.386-393
    • /
    • 2004
  • In this paper, the ultrasonic attenuation coefficient was measured by variation of crack length for double-cantilever beam(DCB) specimen. The energy release rate, G, was obtained by the experimental measurement of compliance. The experimental results represents that the crack length for the ultrasonic attenuation coefficient and energy release rate is increases proportionally From the experimental results, we proposed a detecting method of the crack length by the ultrasonic attenuation coefficient and discussed it.

Ultrasound Image Enhancement using Markov Random Field Model (MRF 모델을 이용한 초음파 영상 개선 기법)

  • Gwak, Seong-Hoon;Park, Eun-Bi;Kim, Ho-Joon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2013.05a
    • /
    • pp.792-795
    • /
    • 2013
  • 본 연구에서는 조영증강 의료 초음파 영상에서 조영제의 도달시간(arrival time)과 전이시간(transit time)에 관한 정보를 영상화하는 과정에서 정보의 왜곡을 개선하는 방법론을 제시한다. 간 질환 진단을 위한 파라미터 영상에서 병변 형태의 왜곡은 호흡에 의한 흔들림 현상과 노이즈의 영향에 기인한다. 본 논문에서는 이를 개선하는 방법으로서 MRF(Markov Random Field) 모델을 적용한 최적화 기법을 제안한다. 이를 위하여 Gibbs 샘플러를 적용하기 위한 에너지 함수를 정의하고 이를 기반으로 하는 영상개선 알고리즘을 구현하였다. 제안된 이론은 실제 의료진단 데이터에 적용함으로써 그 유용성을 평가하였다.

A Study on Ppray Ignition Phenomena Using Shock Tube Combustion System Design (충격파관 시스템설계에 의한 분무의 착화현상 연구)

  • ;水谷幸夫
    • Journal of Energy Engineering
    • /
    • v.3 no.1
    • /
    • pp.54-61
    • /
    • 1994
  • 계단형태의 고온발생장치로서, 고온의 흐름을 형성하고 난류유동이 없이 일정한 혼합기류를 만들 수 있는 2단격막구조 충격파관 장치를 이용하여, 혼합을 동반하지 않는 분무의 착화과정에 관한 실험을 수행하였다. 본 실험에서는 충격파관 속에 하향으로 설치된 초음파 분무기에 의해 자유낙하 상태에 있는 예혼합 분무주를 만들어서 반사충격파에 의해 순간적으로 단열압축시켜서 착화 현상을 관찰하였다. 고온영역과 저온영역에서 얻어진 활성화에너지는 큰 차이가 나며 본 연구에서 얻은 착화지연의 실험결과는 통상의 분무착화 실험인 전기로법, 급속압축기법, 고온기류속에 연료를 분사하는 방법과 다른 현상을 보였다. 그 대표적인 결과에 대한 예로는 착화지연에 대한 압력 의존성과 연료분사율의 영향이 일반적인 분무의 결과에 비해 적게 나타났다.

  • PDF

Analysis of Attenuation Differences According to Radiolucent and Radiopague Materials : Based on DECT (Dual Energy Computed Tomography) (방사선 투과 및 불투과성 물질에 따른 감약 차이의 분석 : DECT 검사 중심으로)

  • Jang, Hyon-Chol;Kim, Yoon-Shin;Kim, Hyeon-Ju
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.3
    • /
    • pp.1584-1589
    • /
    • 2014
  • This study analyzed CT values of radiolucent and radiopaque materials by energy region after selecting radiolucent and radiopaque materials at random using GE's DECT((Dual Energy Com-puted Tomography) at S University Hospital located in Gyeonggi-province from July through August in 2013. Besides, it drew out the most analogous energy region to the value of 120kVp CT, which is applied to existing SECT(Single Energy Computed Tomography), by utilizing the analysis method of CT values and tried to find out the most useful and appropriate materials when contrast was applied within visible area in clinical application. As a result, there was little decrease of CT value after 90KeV in the case of materials with low density and high moisture content such as normal saline, methyl-cellulose and gels used in ultra-sonic waves test; energy does not influence much on materials with extremely low or high density such as air and contrast medium; methyl-cellulose and gels used in ultra-sonic waves test are considered to be the most useful materials for clinical applications.

수십 MeV 양성자빔을 이용한 금속나노입자 제조 기술 및 장치

  • Kim, Gye-Ryeong;Jeong, Myeong-Hwan;Na, Se-Jin
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.493-494
    • /
    • 2011
  • 수 MeV~수십 MeV 양성자빔을 이용해 백금, 은 등의 나노입자 제조실험을 수행하였다. 나노 입자는 의료분야와 산업 분야에서 그 응용성이 다양해 여러 지 방법을 이용한 제조기술이 개발되고 있다. 전자빔, 감마선, 양성자빔 등의 방사선을 이용한 나노입자 제조방법은 가장 널리 이용되고 있는 화학적 제조방법에 비해 비교적 공정이 단순하다는 장점을 가지고 있지만 공정 변수의 제어방법이 확립되어 있지 않아 이에 대한 연구가 필요한 실정이다. 특히, 양성자빔의 경우 에너지에 따른 투과깊이의 조절과 플럭스나 총 선량, LET (Linear Energy Transfer) 등의 변수와 제조된 나노입자의 상관관계 등에 대한 연구가 선행되어야 한다. 본 논문에서는 백금산 용액을 이용한 나노입자 제조 결과와 대면적 양성자빔을 이용하기 위한 초음파 이용 나노입자제조장치의 제작 및 실험결과에 대해 논하고 향후 건설될 100MeV 선형 양성자가속장치의 나노입자 제조실험에의 응용을 위한 이용시설을 소개하고자 한다. 나노입자 제조실험은 한국원자력의학원의 MC-50 싸이클로트론을 이용하여 수행하였으며, 가속기로부터 인출되는 에너지는 35, 45MeV, 빔전류는 수십 nA~수${\mu}A$의 범위 내에서 조절하였다. 제조된 나노입자는 TEM을 이용하여 그 크기와 분포를 관찰하였다. 대면적의 양성자빔을 이용하는 경우, 수mm의 두께와 수십 cm의 직경을 가지는 원반 모양의 시료용기를 사용하여 양성자빔의 에너지와 선량을 정확히 조절할 수 있게 되는데 이 때 용기 내 시료와 양성자빔간의 균일한 반응을 위해 용액을 적절하게 섞어 주어야만 한다. 이러한 목적으로 초음파를 이용하여 나노입자 제조장치를 제작하여 실험을 수행하였다. 나노입자 제조는 현재 교과부의 지원으로 경주 건천지역에 건설되고 있는 100MeV 선형양성자가속기의 주요 이용 분야 중의 하나로 20MeV 빔라인 중 한 개의 빔라인과 표적실을 나노입자 제조 등의 실험을 위한 시설로 구축 중이다. 최대 평균전류 1.6mA 까지 가능하고 펄스폭은 0.05~1.33 msec까지 조절가능하도록 개발되고 있다.

  • PDF