• Title/Summary/Keyword: 초음파 무화

Search Result 20, Processing Time 0.03 seconds

A Behavior of the Ultrasonically-atomized Kerosene Lifted-flame According to the Position of Ultrasonic Standing-wave Field (정상초음파장의 위치에 따른 초음파 무화 케로신 부상화염의 거동)

  • Chang Han Bae;Jeong Soo Kim
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.27 no.1
    • /
    • pp.1-8
    • /
    • 2023
  • A study was conducted to scrutinize the behavior of the ultrasonically-atomized kerosene lifted-flame according to the carrier gas flow-rate and position of ultrasonic standing wave (USW). The combustion region of the kerosene-aerosol generated through a slit-jet nozzle was visualized using a DSLR, ICCD, high-speed camera, and Schlieren technique, and the fuel consumption was measured by using a precision balance. As a result, the flame was confined within the region bounded by the USW-field, and the fuel consumption decreased as the position of the USW field increased.

Behavioral Change of the Ultrasonic Standing Wave-affected Flame in the Reaction Zone of the Ultrasonically-atomized Kerosene Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통해 분사되는 초음파 무화 케로신 화염의 정상초음파 가진에 의한 거동 변이)

  • Bae, Chang Han;Kang, Yun Hyeong;Ahn, Hyun Jong;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.26 no.1
    • /
    • pp.60-67
    • /
    • 2022
  • A study was conducted to analyze the behavioral change of the kerosene flame ultrasonically-atomized under an ultrasonic standing-wave. Combustion region was visualized through DSLR, ICCD camera and the Schlieren photography with high-speed camera. The fuel consumption was measured by a precise scale. As a result, in the case of ultrasonic standing-wave excitation, it was observed that the intensity of OH radical(OH*) was enhanced and optimal combustion condition was formed around the upper edge of the standing-wave field.

Filtration of dispersed nanoparticles using cyclone and ultrasonic atomization (초음파 무화 및 사이클론을 이용한 분산된 나노입자의 여과법)

  • Jung, Jihee;Kim, Moojoon;Kim, Jungsoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.41 no.1
    • /
    • pp.9-15
    • /
    • 2022
  • In order to overcome the limitation of conventional nanoparticle dispersion methods such as sonicator or homogenizer, a filtration method using an ultrasonic atomization effect and cyclones was proposed in this study. A 0.5 wt% suspension was made with Al2O3 powder with an average diameter of 250 nm. The suspension was filtered by the proposed method after pre-dispersing using a sonicator and a homogenizer, respectively. As the result, in the case of the suspension after pre-dispersing with a sonicator, the particle size distribution of the filtered suspension started showing up a single normal distribution indicating the mode of the average diameter only after the 3rd cyclone process. On the other hand, in the case of the suspension with the homogenizer pre-dispersion, similar results appeared from the 2nd cyclone process. Filtration of various types of nanoparticles is expected to be possible by adjusting ultrasonic atomization frequency and manipulating the design of the cyclone.

Suggestion of separation and recollection method of nano particles from suspension by using ultrasonic atomization (초음파 무화효과를 이용한 현탁액으로부터 나노입자의 분리포집법 제안)

  • Kim, Jihyang;Kim, Jungsoon;Yeom, Jiyeong;Ha, Kanglyeol;Kim, Moojoon
    • The Journal of the Acoustical Society of Korea
    • /
    • v.35 no.6
    • /
    • pp.445-451
    • /
    • 2016
  • It is very important to obtain non-agglomerated nano particle state for practical application of nano technology. In order to improve the functionality of products using nano particles, more precise control of particle size distribution is required in their synthesis process. However, synthesized nano particles are agglomerated easily due to physical and chemical reasons, and it then veils unique properties of the nano particles and causes some troubles in their practical application. In this study, a separation method for nano particles from suspension by using the droplets as the separation space was proposed. Using the suspension of 0.002 wt. % with $TiO_2$ powder, the particle size distribution of nano particles in the recollected suspension was measured. From the results, it was confirmed that it is possible to separate and to recollect the nano particles monodispersed by using the suggested method.

Effects of Ultrasonic Standing Wave on the Ultrasonically-atomized Aerosol Flame Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통과한 초음파 무화 에어로졸 화염에 정상초음파가 미치는 영향)

  • Ahn, Hyun Jong;Kang, Yun Hyeong;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.24 no.6
    • /
    • pp.53-60
    • /
    • 2020
  • In liquid-fuel spray combustion, an experimental study was conducted to observe the effect of ultrasonic excitation on the ultrasonically-atomized liquid fuel flame by controlling pressure field through an ultrasonic standing wave. Flame of the ultrasonically-atomized kerosene aerosol was visualized by using a high speed camera, DSLR, and Schlieren photography. The amount of fuel consumed was obtained by a precise flow-rate measurement technique during combustion, through which the ratio of carrier gas (air) to fuel mass was able to be obtained, too. As a result, it could be found that the combustion reaction-rate of the liquid-fuel aerosol was increased by applying an ultrasonic standing wave to the secondary flame zone of the flame.

A study on the characteristics of fuel spray for EFI type using the ultrasonic fuel feeding system (초음파 연료 공급장치를 이용한 EFI방식의 연료분무 특성에 관한 연구)

  • 윤면근;류정인
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.16 no.6
    • /
    • pp.16-21
    • /
    • 1994
  • 본 연구에서는 연료의 핵심기술인 분사기술을 향상시키기 위하여 연료의 고압분사와 초음파 에너지 공급기술을 이용하여 연료의 미립화를 시도하고 EFI연료 분사방식에서 초음파 공급장치를 개발하여 추후 직접 분사식 초음파 무화장치의 개발을 위한 기초를 마련하고 직접 분사식에서 문제시되어지는 분사 초기 또는 분사 말기의 분사연료 미립화의 분사 전구간에서의 분사연료의 미립화를 시도하기 위한 기초를 마련하고자 한다.

  • PDF

Flame Formation of Ultrasonically-atomized Liquid-fuel Injected through a Slit-jet Nozzle (Slit-jet 노즐을 통해 분사되는 초음파 무화 액체연료 화염의 형성)

  • Kim, Min Sung;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.21 no.1
    • /
    • pp.17-25
    • /
    • 2017
  • An experimental study was performed for the combustion-field visualization of the burner which burns the liquid hydrocarbon fuel atomized by an ultrasonic oscillator. Configurations of the flame and temperature gradient were caught by both high-speed camera and thermo-graphic camera, and those images were analyzed in detail through a post-processing. In addition, the fuel consumption was measured using the balance during the combustion reaction. As a result, the consumption of atomized fuel increased with the increasing flow-rate of carrier-gas, but any correlation between the air/fuel ratio and carrier-gas flow-rate was not found at the low flow-rate condition. Also, the combustion-field grew and reaction-temperature rose due to the strengthening of combustion reaction with the increasing flow-rate of carrier-gas and power consumption of ultrasonic oscillator.

Effects of the Carrier-gas Flow-rate on the Combustion Characteristics of the Ultrasonically-atomized Slit-jet Flame (초음파에 의해 무화된 슬릿제트화염의 연소특성에 대한 수송기체 유량의 영향)

  • Kim, Min Sung;Bae, Dae Seok;Kim, Jeong Soo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.9-16
    • /
    • 2016
  • An experimental study was performed to investigate the combustion characteristics of the liquid hydrocarbon fuel atomized by an ultrasonic oscillator. Configuration of the flame was caught by the high-speed camera, and images were analyzed in detail through a post-processing. In addition, the fuel consumption was measured using the balance during the combustion reaction. As a result, the consumption of atomized fuel increased with the increasing flow-rate of carrier-gas, but any correlation between the air/fuel ratio and carrier-gas flow-rate was not found. The variation of flame area was dependent on the fuel consumption and input power of the ultrasonic oscillator. FFT (Fast Fourier Transform) analyses using the flame area were conducted in order to discuss flame flickering.

A Study on the Performance Improvement of Diesel Automobile Engine with Ultrasonic Fuel Feeding System(II)-On the Spray Characteristics and Engine Performance- (초음파 연료분사장치용 디젤자동차의 성능향상에 관한 연구(II)-분무특성과 기관성능에 대하여-)

  • Yang, J.K.;Jung, J.D.;Ryu, J. I.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.50-56
    • /
    • 1994
  • This is an experimental study on the performance characteristics of Diesel Automobile with ultrasonic fuel feeding system. For this purpose, ultrasonic fuel feeding system was made and atomization characteristics was measured. Base on this result, carried out engine dynamometer test to investigate the performance characteristics of diesel automobile with ultrasonic fuel feeding system in comparison with conventional diesel fuel injector. The results are as follows. 1) In the spray characteristics test, fuel particle sizes were decreased about 11%~21%. 2) In engine dynamometer test, -The power was increased about 5%~11%. -The thermal efficiency was improved about 6%~11%. -The specific fuel consumption was improved about 6%~19%. -The smoke concentration was decreased about 11%~50%.

  • PDF

A Study on the Atomization Characteristics of the Ultrasonic-Energy-Irradiation High Viscosity Biodiesel Blended Fuel (초음파 에너지 조사 고 점도 바이오디젤 혼합연료의 미립화 특성에 관한 연구)

  • Song Yong-Seek;Yang In-Kwon;Kim Bong-Seock;Ryu Jung-In
    • Journal of Energy Engineering
    • /
    • v.13 no.4
    • /
    • pp.235-241
    • /
    • 2004
  • This experiment was undertaken to investigate the atomization characteristics of the high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Test fuels were conventional diesel fuel and biodiesel one. We compared to the characteristics of viscosity and surface tension, SMD between high viscosity biodiesel blended fuel and ultrasonic energy irradiation one. Sauter mean diameter was measured under the variation of the spray distance. Viscosity and surface tension were measured under the variation of the time trace. To measure the droplet size, we used the Malvern system 2600c. Droplet size distribution was analyzed from the result data of Malvern system. Through this experiment, we found that the condition of the ultrasonic energy irradiation situation had smaller Sauter mean diameter of droplet, viscosity and surface tension than those of the conventional situation.