• Title/Summary/Keyword: 초음파촬영

Search Result 338, Processing Time 0.034 seconds

Research of Remote Inspection Method for River Bridge using Sonar and visual system (수중초음파와 광학영상의 하이브리드 시스템을 이용한 교각 수중부 원격점검 기법 연구)

  • Jung, Ju-Yeong;Yoon, Hyuk-Jin;Cho, Hyun-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.5
    • /
    • pp.330-335
    • /
    • 2017
  • This study applied SONAR(Sound Navigation And Ranging) to the inspection and evaluation of underwater structures. Anactual river bridge was chosen for inspection and evaluation. SONAR and an optical camera were operated together to analyze the underwater image of the bridge. SONAR images were obtained by various methods to remove the environmental variables from the field experiment, and it was confirmed that the reliability of detecting damaged areas on piers was decreased when using SONAR alone. The SONAR equipment and the optical camera can be used simultaneously to overcome the limitations of SONAR in inspecting underwater structures.These results can be used as basic data for the development of similar technologies for underwater structure inspection.

THE ASSESSMENT OF ULTRASONOGRAPHIC ECHOGENICITY IN NORMAL HUMAN PAROTID AND SUBMANDIBULAR GLANDS (정상 이하선과 악하선에 대한 초음파영상의 반향성 평가)

  • Lee Jean;Park Tae-Won
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.1
    • /
    • pp.167-177
    • /
    • 1997
  • 타액선 병변의 일반적인 영상진단법으로는 타액선조영술, 전산화단층촬영술, 자기공명 영상, 타액선 스캔, 초음파 촬영술이 있다. 이중 초음파촬영술은 타액선내 종양의 유무를 평가하는데 있어서 매우 우수하여, 전산화단층촬영이나 자기공명영상과 더불어 이용되고 있으나, 염증을 진단하는데 있어서는 타액선조영술보다 민감도가 떨어지는 단점이 있다. 일반적으로 타액선의 염증반응시 초음파상은 반향이 정상보다 낮아지며, 내부의 균질성이 떨어지는 양상을 보여 이를 진단의 기준으로 이용해왔으나 정상타액선에서도 반향이 편차가 심할 뿐만 아니라 연령에 따른 정상 타액선의 반향성에 대한 연구가 부족하여 진단에 어려움이 있었다. 이에 저자는 우선적으로 타액선에 병적인 증상이 없는 남녀 90명을 연령별(20-35세 : 청년군, 36~55세 : 중년군, 55-70세 노년군),성별에 따라 분류하여 정상 타액선의 초음파상을 얻었다. 이의 반향을 측정하고, 비만한 정도를 나타내는 체격지수를 구하여 다음과 같은 결과를 얻었다. 1. 이하선과 악하선 모두에서 연령군극_ 따라 반향성이 증가하는 양상을 보였으며, 청년군과 노년군 사이에는 유의한 차이가 있었다(p<0.05). 2. 이하선과 악하선 모두에서 성에 따른 반향성의 유의한 차이는 없었다. 3. 성에 관계없이 악하선의 반향성이 이하선의 반향성보다 높았으며, 남자에 있어서는 유의한 차이가 있었다(p<0.05). 4. 동일한 타액선에서 좌우측 타액선의 반향성의 평균 차이값은 유의한 차이가 없었다. 5. 이하선과 악하선의 반향성은 중등도의 양의 상관관계를 보였다(남자 : r=0.56, 여자 : r=0.54). 6. 체격지수와 타액선의 반향성은 약한 양의 상관관계를 보였다.

  • PDF

Fatty Liver Classification of Ultrasonography Images using SOM Method (SOM 기법을 이용한 초음파 영상에서의 지방간 분류)

  • Park, Ha-Sil;Han, Min-Su;Kim, Young-Hoon;Kim, Kwang-Baek
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2014.07a
    • /
    • pp.419-422
    • /
    • 2014
  • 본 논문에서는 환자와 검사자에게 초음파 영상의 객관화된 정보를 정확하게 제공하기 위해 간과 신장의 초음파 영상에 SOM 기법을 적용하여 지방간 농도 수치를 분류하는 방법을 제시한다. 제안된 방법은 간, 신장 영역을 촬영한 초음파 영상에서 촬영정보나 눈금자 등과 같이 필요 없는 부분을 잡음으로 간주하여 제거한 Region Of Interest(ROI) 영상을 추출하고, 추출된 ROI 영상에서 명암대비를 강조하기 위해 Fuzzy Stretching 기법을 적용한다. Stretching된 영상에 Enhanced Average Binary와 Labeling 기법으로 적용하여 얻은 Contour 정보를 분석하여 잡음을 제거한 후, 지방간의 측정 영역을 추출한다. 추출된 간과 신장의 측정 영역에 SOM 기법을 적용하여 명암도 값을 분류한 후, 간과 신장의 실질 영역의 대표 명암도를 각각 추출하여 비교 분석한다. 제안된 방법을 초음파 영상에 적용한 결과, 효율적이고 객관적으로 간의 지방도를 분류할 수 있는 가능성을 확인하였다.

  • PDF

Studies on Genetic Parameter Estimation and Sire Selection to Ultrasound Measurement Traits of Hanwoo (한우 초음파생체단층촬영 형질에 대한 유전모수 추정과 씨수소 선발에 관한 연구)

  • Roh, Seung-Hee;Kim, Chang-Yeup;Won, You-Seog;Park, Chel-Jin;Lee, Sung-Soo;Lee, Jeng-Gyu
    • Journal of Animal Science and Technology
    • /
    • v.52 no.1
    • /
    • pp.1-8
    • /
    • 2010
  • This study is conducted to use the real-time ultrasound measurement data of Hanwoo as basic data being available to improvement. We used the ultrasound measurement data of 1,125 heads of performance tested cattle and the carcass data after castrating at about 12 months of age, fattened to 30 months, and then sold. For 921 heads of progeny tested cattle, we used test data and slaughter data. Heritabilities of ultrasound data for longissimus muscle area and backfat thickness measured at 12 months of age were estimated as 0.57 and- 0.41, respectively, and at 24 months of age, it was 0.57 and- 0.60, respectively, with high heritability. However, in estimation value of heritability containing ultrasound measurement for percent intramuscular fat, it showed low and medium heritability as 0.14 at 12 months of age and 0.22 at 24 months of age for each. The longissimus muscle area, backfat thickness, and percent intramuscular fat of ultrasound measure traits and longissimus muscle area, backfat thickness, marbling score of carcass traits genetic correlation of at 12 months of age were estimated as 0.616, 0.544, 0.501, respectively and at 24 months of age, it showed high genetic correlation as 0.894, 0.937, 0.263, respectively. As a result of ranking correlation between selection index by using weight, carcass traits at 12 months of age and selection index based on ultrasound measurement data which has high genetic correlation, in data of ultrasound measurement at 12 months of age, it showed high ranking correlation as that selection index of young bull was 0.140 and that of proven bull was 0.843.

Gallbladder Agenesis in a Miniature Pinscher : Computed Tomographic and Ultrasonographic Features (담낭 무형성을 가진 미니어쳐 핀셔에서 컴퓨터단층촬영과 초음파 특징)

  • Kim, Seung-Gon;Kang, Min-Hee;Park, Hee-Myung
    • Journal of Veterinary Clinics
    • /
    • v.30 no.2
    • /
    • pp.111-114
    • /
    • 2013
  • A 4-year-old spayed female Miniature Pinscher was presented with a 3.5-year history of elevated liver enzymes level. Continuous elevation of liver enzymes was found on repeated blood examinations and the dog was referred for further evaluation. The abdominal ultrasonography revealed that the gallbladder could not be visualized in any plane. The absence of gallbladder was suspected on ultrasonography. Computed tomography (CT) confirmed gallbladder agenesis (GBA). This is the first reported case of diagnosis of GBA in Miniature Pinscher by using CT.

Volumetric Estimation of the Prostate Gland using Computed Tomography in Normal Beagle Dogs (정상 비글견에서 컴퓨터단층촬영술을 이용한 전립선의 부피 평가)

  • Choi, Ji-Young;Choi, Soo-Young;Lee, Ki-Ja;Jeong, Woo-Chang;Han, Woo-Sok;Choi, Ho-Jung;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.31 no.3
    • /
    • pp.175-179
    • /
    • 2014
  • The purpose of this study was to determine and compare prostate size using ultrasound and computed tomography (CT). The prostate gland was evaluated in eight normal Beagle dogs. Length, depth, and width of the prostate gland were measured by ultrasound and volume of the prostate was obtained from the two ellipsoid formula (US1, US2). Height, length, width, area, and volume of the prostate gland were measured by CT. Ratios of prostatic height, length, and width to the sixth lumbar vertebral body length were calculated. There was no significant difference between the US1 and US2 method, and between US2 and CT method, respectively. The prostatic volume calculated by US1 method was significantly lower than those with CT (p=0.029). The Upper limits of ratios of prostate length, height, and width to the length of the sixth lumbar vertebra were 1.3, 1.1, and 1.7, respectively. Among these prostate dimensions, prostate length and height could be a useful index in estimating prostate size regardless of body weight.

Analysis of Diagnostic Performance of CT and EUS for Clinical TN Staging of Gastric Cancer (위암의 임상적 병기 설정을 위한 전산화단층촬영 및 초음파 내시경의 진단력 평가)

  • Shin, Ru-Mi;Lee, Ju-Hee;Lee, Moon-Soo;Park, Do-Joong;Kim, Hyung-Ho;Yang, Han-Kwang;Lee, Kuhn-Uk
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.177-185
    • /
    • 2009
  • Purpose: Preoperative clinical staging of gastric cancer is very important for determining the treatment plans and predicting the prognosis. The previous reports regarding the accuracy of computed tomography or endoscopic ultrasound for the preoperative staging of gastric cancer have shown various outcomes. We analyzed the diagnostic performance of CT and EUS, which are important staging tools for the staging of TN gastric cancer. Materials and Methods: We retrospectively analyzed 1,174 patients who underwent gastrectomy for gastric cancer at Seoul National University Bundang Hostpital from May, 2003 to December, 2007. We derived the Kappa value to examine the agreement of the preoperative staging obtained from CT and EUS with the pathological staging. Results: The mean age of the 1,174 patients was $59.31{\pm}11.98$ years. Six hundred thirty seven patients had early gastric cancer and 536 had advanced gastric cancer. The diagnostic performance between CT and EUS for the T staging showed no significant difference between CT and EUS for the kappa values. The kappa values showed moderate agreement at 0.4039 (P=0.021) and 0.4201 (P=0.026), respectively. This suggests that there is no difference between the two examinations for the overall T staging. Analysis of the discrimination of mucosal and submucosal lesions with EUS showed an accuracy of 58.92% and a Kappa value of 0.206 (P<0.001), suggesting fair agreement and a lower diagnostic performance than expected. To differentiate lesions with stages higher than or equal to T2 or T3 from the lesion with stages lower than T2 or T3, respectively, adoption of the higher stage from the CT staging or the EUS staging showed a larger AUC of 0.84 than that from either stage alone. The CT-derived node stage had the higher diagnostic performance (68.55%) than that of the EUS-derived node stage (60.82%) for the node staging. Conclusion: The CT-derived stage and EUS-derived stage showed comparable results for determining the T stage of gastric cancer. Yet the higher stage of the two stages from CT and EUS most accurately discriminated between those lesions with stages higher than T2 and those lesions with stages lower than T2.

  • PDF

Ultrasounds Image on the Disorders of the Ligaments Surrounding Temporomandibular Joints (측두하악관절 주변인대 질환의 초음파영상)

  • Hong, Soo-Min;Im, Yeong-Gwan;Kim, Byung-Gook
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.4
    • /
    • pp.387-394
    • /
    • 2008
  • Purpose : The purpose of this study was to verify the usefulness and feasibility of ultrasonographic imaging for the detection of the disorders of the surrounding supporting structure such as articular capsule, retrodiscal tissue and related ligaments, osteoarthritic evidence and associated disc displacement at the temporomandibular joint(TMJ) Materials and Methods : 20 patients(40 joints) with periodic lock and crepitations were investigated prospectively using 12 MHz array transducer. Ultrasonographic Imagings were assessed for osteoarthritic surface changes of condyle, extent of disc displacement and disorders of surrounding structures. Ultrasonographic images were compared with clinical investigations, conventional radiography and Dental Computed Tomographic scans. Results : In clinical and conventional radiography, osteoarthritic changes were diagnosed in 8 joints. Ultrasonographically 7 of the 8 osteoarthritic changes were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 87.5%, 62.5%, and 67.5% respectively. About the detection of disc displacement, disc displacement were diagnosed in 21 joints clinically. Ultrasonographically 19 of the 21 disc displacements were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 95%, 90%, and 92.5% respectively. when the disorders of supportive structure were figured out, the disorders of supportive structure were diagnosed in 18 joints clinically. Ultrasonographically 1 of the 18 the disorders of supportive structure were diagnosed correctly. Sensitivity, specificity, and accuracy of ultrasonography in the osteoarthritic detections were 5.5%, 4.5%, and 55% respectively. Conclusion : Ultrasonography is an relatively reliable diagnostic tool for the detection of disc displacement and some of osteoarthritic changes. But it's not an insufficient imaging technique for the detection of the disorders of the surrounding structure.

Usefulness of X-ray Guided Biopsy and Ultrasound Guided Biopsy in Breast Microcalcification Biopsy (유방 미세석회화 조직검사에서 X선 유도 하 조직검사와 초음파 유도 하 조직검사의 유용성)

  • Choi, Miseon;Song, Jongnam
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.201-206
    • /
    • 2016
  • Social interest in breast cancer has increased. The most basic exams for diagnosis include breast X-ray and breast ultrasound. In particular, breast microcalcification requires histological diagnosis, and breast microcalcification biopsy is commonly performed. Therefore, this study aimed to analyze and assess X-ray guided biopsy (needle localized open biopsy) and ultrasound guided biopsy (sono guided core needle biopsy), which are basics in diagnosis of microcalcification. Targeting 241 cases in which magnification mammography was performed for patients who visited the hospital due to breast microcalcification, age distribution and the location of lesions were analyzed in X-ray guided biopsy and ultrasound guided biopsy. By classifying exams performed after magnification mammography, the frequencies of X-ray guided biopsy and ultrasound guided biopsy were analyzed, and malignant and benign results were confirmed. The results showed that 64 cases(26.6%) were X-ray guided biopsy, which was 5.4 times higher than 12 cases(4.9%) of ultrasound guided biopsy. Due to development of ultrasound equipments, stereotactic vacuum-assisted biopsy, etc. the methods of histological diagnosis of microcalcification have become diverse, but when considering characteristics and limitations of each exam, X-ray guided biopsy is thought to be most accurate and useful.

Transducer Combination for High-Quality Ultrasound Tomography Based on Speed of Sound Imaging (속도 분포 기반 단층촬영을 위한 최적의 트랜스듀서의 조합)

  • Kim, Young Hun;Park, Kwan Kyu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.36 no.1
    • /
    • pp.27-34
    • /
    • 2016
  • The type of ultrasound transducer used influences the quality of a reconstructed ultrasound image. This study analyzed the effect of transducer type on ultrasound computed tomography (UCT) image quality. The UCT was modeled in an ultrasound simulator by using a 5 cm anatomy model and a ring-shape 5 MHz 128 transducer array, which considered attenuation, refraction, and reflection. Speed-of-sound images were reconstructed by the Radon transform as the UCT image modality. Acoustic impedance images were also reconstructed by the delay-and-sum (DAS) method, which considered the speed of sound information. To determine the optimal combination of transducers in observation, point-source, flat, and focused transducers were tested in combination as trasmitters and receivers; UCT images were constructed from each combination. The combination of point-source/flat transducer as transmitting and receiving devices presented the best reconstructed image quality. In UCT implementation, the combination of a flat transducer for transmitting and a point transducer for receiving permitted acceptable image quality.