• Title/Summary/Keyword: 초음파의 영향

Search Result 983, Processing Time 0.038 seconds

Determination of Localized Defects in Wood by the Transfer Time of Ultrasonic Waves (초음파의 통과시간을 이용한 목재 결점부위의 평가)

  • Park, Jun-Chul;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.36 no.1
    • /
    • pp.61-68
    • /
    • 2008
  • The effect of rupture on the speed of ultrasonic wave was investigated with the PUNDIT and the effective detecting method of defects, moving transmitter and receiver. The speed of ultrasonic wave according to the course of rupture was not affected by transmitter and receiver and in the course of parallel rupture, but only in the course of vertical rupture. When rupture was not located on the ultrasonic wave progressing course, rupture was not detected. However, if rupture was formed perpendicularly to the ultrasonic wave progressing course but located on the ultrasonic wave progressing direction, rupture can be detected. Also, the rupture can be detected, when one transmitter and receiver was placed at top and the other at bottom. After detecting rupture in a part, rupture was determined accurately, placing and moving two transmitters and receivers at width.

A Study on the ultrasonic wave-assisted pd activation for electroless Ag plating (무전해 은도금시 팔라듐 활성화 단계에서의 초음파의 영향 고찰)

  • Lee, Chang-Myeon;Lee, Hong-Gi;Heo, Jin-Yeong;Lee, Min-Hyeong;Lee, Ho-Nyeon
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2011.05a
    • /
    • pp.149-150
    • /
    • 2011
  • 미세화된 반도체 배선에 무전해 은도금을 적용하고자 새로운 Pd 활성화 공정을 제안하였다. 시편 표면에 작은 크기의 Pd 입자를 균일하게 분포시키기 위하여 Pd 활성화 도중 초음파을 가하였다. 추가적인 무전해 은 도금을 실시하여, 초음파에 의한 Pd 입자 분산이 은도금 피막 형성에 미치는 영향에 대하여 고찰하였다.

  • PDF

Application of Super Sonic Wave Technic to Textile Industry (섬유산업에 초음파 응용기술)

  • Seo, Mal Yong;Lee, Suk Young
    • Textile Coloration and Finishing
    • /
    • v.8 no.4
    • /
    • pp.59-68
    • /
    • 1996
  • 섬유산업에 초음파의 이용은 극히 새로운 것이 아니며, 초음파를 이용하여 시간단축과 공정개선 등에 관한 많은 문헌들도 있다. 게다가 세정과 기계분야, 안정된 분산용액의 제조에 두드러지게 활용되고 있는 기술이며, 다른 새로운 분야로도 연구확대되고 있다. 주로 세정조에 구성되어 있는 초음파발생자치는 세정효율을 높이기 때문에 응용확대가 기대된다. 특별한 장치가 필요없기 때문에 음화학반응에서 관심이 모아지고 있다. 초음파는 이제 광범위한 습식공정에 영향을 미치는 기술로 이해되고 있다. 이 자료는 이미 연구된 결과를 재조명하고 초음파를 이용하므로서 얻을 수 있는 이점에 대해서 어떤 것이 있는지에 대해 살펴보고자 한다.

  • PDF

Effect of Ultrasound on the Acid Hydrolysis of Inulin (Inulin의 산 가수분해 반응에서 초음파가 미치는 영향)

  • 김성배;윤석준
    • KSBB Journal
    • /
    • v.8 no.4
    • /
    • pp.358-363
    • /
    • 1993
  • The effect of ultrasound on the acid hydrolysis of inulin was studied under significantly mild reaction conditions, at which sugar degradation products were not detected. Reaction conditions were i the range of 50~$60^{\circ}C$ and 0.1~0.3%(w/w) of HCl concentrations. The effects of reactor position inside water bath and mechanical agitation under ultrasound were investigated. The production rates of fructose with/without ultrasound irradiation were compared. The activation energies for both control and ultrasound reaction were the same, i. e., 25kca1/mo1, and ultrasound enhancement was average 22%.

  • PDF

Pulsed Electromagnetic Field and Pulsed Ultrasound Increases Chondrogenesis through HSP70 Overexpression in Rat Articular Cartilage (흰쥐의 관절연골에서 맥동전자장과 맥동초음파가 HSP70의 과발현을 통한 연골형성에 미치는 영향)

  • Koo, Hyun-Mo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.8 no.1
    • /
    • pp.111-116
    • /
    • 2013
  • 연구목적: 본 연구는 흰쥐를 대상으로 정강뼈의 관절연골에 적용한 맥동전자장과 맥동초음파가 HSP70(Heat shock protein 70)의 발현을 통한 연골 형성에 미치는 영향을 알아보고자 실시하였다. 연구방법: 36마리의 200~250g의 Sprague-Dawley 흰쥐를 대조군, 맥동전자장 적용군, 맥동초음파 적용군으로 각 집단별로 12마리씩 무작위 배정하여 실험을 진행하였다. 맥동전자장은 27.12 MHz의 주파수, 5가우스의 강도, 450 W의 출력으로 10분간 적용하였고, 맥동초음파는 20%의 맥동비, 1MHz의 주파수, $1.5W/cm^2$의 강도로 10분간 적용하였다. 연구결과: 맥동전자장 적용군과 맥동초음파 적용군의 관절연골 조직에서 유의한 수준의 HSP70 발현량을 나타냈다. 또한 맥동전자장 적용군과 맥동초음파 적용군에서는 Akt, Erk1, CREB의 높은 활성도를 나타내었고, 맥동초음파 적용군에 비해서 맥동전자장 적용군의 더 높은 수준의 활성도를 보였다. 결론: 맥동전자장과 맥동초음파는 HSP70의 과발현을 유발하고, 이를 통해 연골형성을 증가시키는 것으로 나타나, 향후 관절연골의 손상에 대한 임상적 적용을 위한 추가적인 연구가 진행되어야 할 것으로 생각된다.

Frequency Spectrum Analysis of Corona Discharge Source Measured by Ultrasound Detector (초음파 감지기로 측정한 코로나 방전 소스의 주파수 스펙트럼 분석)

  • Cho, Hyun-Seob
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.12 no.1
    • /
    • pp.78-82
    • /
    • 2019
  • This paper addressed the spectrum of ultrasonic waves produced by arc and/or coronal discharge inside the switchboard. Portable ultrasound sensors are useful for detecting discharge phenomena, such as coronal means in electrical systems. However, a typical handheld ultrasound detector has a disadvantage of determining the type of problem by listening to the sound characteristics and predicting the results, as a result of the determination of whether a discharge is present. Therefore, a new method of analysis is required to distinguish ultrasonic characteristics. In this paper, we published an ultrasound analysis case study to visualize the sound of ultrasonic waves measured with ultrasonic sensors. From the results of the experiment, it was possible to detect coronal discharge and serial arc discharge without interference by the ultrasonic detection system.

Effects of Ultrasonic Treatment Time on the Quality and Palatability of fried Chicken Meat (초음파 처리시간이 튀김 계육의 품질 및 기호성에 미치는 영향)

  • 남주현;송형익;박충균;박성하;김도완;문윤희;정인철
    • Food Science of Animal Resources
    • /
    • v.22 no.2
    • /
    • pp.115-121
    • /
    • 2002
  • This study was carried out to investigate the effect of ultrasonic treatmeat time on the quality and palatability of fried chicken meat. Moisture content, U-10 treatment (chicken meat treated by ultrasonification for 10 minutes) of breast and leg were lower than those of the control, protein contents were not different between samples. Fat content was higher with increasing ultrasonic treated time. Frying loss of ultrasonic treated breast and leg were lower than those of the control, water holding capacity of ultrasonic treated breast and leg were higher than those of the control with increasing ultrasonic treated time. Rheological textures between control and ultrasonic treated samples were not different. L* value(lightness) between control and ultrasonic treated samples were not different, but L* values of breast were higher than those of the leg. And a* value(redness) was not effect by ultrasonic treatment, but a* value of leg were higher than those of the breast. Amino acid composition has included many glutamic acid, aspartic acid, lysine, leucine and arginine. Oleic acid and linoleic acid occupied beyond 50% of fatty acid composition. And taste, texture, juiciness and palatability improved with increasing ultrasonic treated time.

최근 차량센서의 연구개발현황

  • 이근배
    • 전기의세계
    • /
    • v.34 no.10
    • /
    • pp.620-625
    • /
    • 1985
  • 고도측정정도에 대하여 실제운용상태의 측정출력데이터는 차량의 진속도에 대해 10% 이내로 생각하면 차이가 없다. 또한 환경조건중 바람의 영향은 전술한바와 같이 풍속 10m/s에서는 30km/h인 경우 0.17%, 100km/j인경우 0.32% 또한 풍속 25m/s에서는 30km/h인경우 0.7%, 100km/h인경우 1.1%정도하는 것이 이론적으로 구해진다. 한편 기온의 영향도 원리적으로 초음파의 전번속도가 대기온의 영향을 받아서 오차요인이 되기 때문에 초음파헤드내에 온도센서를 실구해서 대기온을 거상측정하고 이 값으로서 속도연산을 포상하는 수단을 취하고 있다.

  • PDF

Effects of Piezoelectric Material Constants on the Performance of Ultrasonic Transducers (초음파 탐촉자 성능에 미치는 압전재료 물성의 영향)

  • 노용래;임종인
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.1E
    • /
    • pp.48-55
    • /
    • 1993
  • 초음파 탐촉자의 개발에 필요한 압전재료의 선택을 위하여 탐촉자의 성능에 영향을 미치는 탄성, 유전, 압전 상수의 영향을 알아보았다. 해석 방법으로는 등가회로를 통한 두께 모드 발신기, 수신기, 펄스 반사기의 전달함수를 구하였으며, 이로부터 압전재료의 각 물성치가 가져야 할 바람직한 특성을 제시하였다. 본 연구의 결과는 재료의 선택시와 더불어 세라믹 공학자들이 초음파용 압전소자를 개발함에 있어 적절한 지침이 될 수 있을 것이다.

  • PDF

Influence to the Doppler Images by the Defects of SAE in the Probe of Medical Ultrasonic Scanners (초음파 프로브에서 인접 단위 소자군(SAE) 결함이 도플러 영상에 미치는 영향)

  • Lee, Kyung-Sung
    • Journal of radiological science and technology
    • /
    • v.38 no.1
    • /
    • pp.7-15
    • /
    • 2015
  • A ultrasonic probe is very important in medical ultrasonic image, but the frequency of probe defects are often. Therefore practical tools for probe based ultrasonic QA should be developed. Advanced research on the effects of the probe defects on the quality of ultrasonic images is required. This study has investigated the effects of the defects in the probe elements influence Doppler images in the medical ultrasonic scanners. Especially the defects in a set of adjacent elements(SAE) electrically disconnected influence Doppler images were tested. The results show Doppler brightness and velocity became rapidly reduced as the defected elements is located centrally, as the defected elements is activated. The more the defected elements increased, the more Doppler brightness and velocity increased. As a set of the element disconnected moved, it appeared Doppler velocity starting to decrease and then was followed by brightness. The strength is not consistent with the velocity in the number and location of the defected elements. The defects in the probe elements influence Doppler velocity when the defected elements got out of the elements activated at Doppler mode.