• Title/Summary/Keyword: 초음파세척기

Search Result 38, Processing Time 0.048 seconds

The Effects of Ultrasonic Cleaner for Eye Glasses on Protein Deposits and Parameters in Soft Contact Lens (안경용 초음파세척기에 의한 소프트콘택트렌즈의 단백질 침전물 세척효과)

  • Ju, Eun-Hee;Lee, Koon-Ja;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.3
    • /
    • pp.227-234
    • /
    • 2010
  • Purpose: The cleaning effect of protein deposit and the change of contact lens parameters by ultrasonic cleaner for eye glasses on the soft contact lenses were investigated. Methods: Etafilcon A contact lenses contaminated with protein, was ultrasonicated by ultrasonic cleaner for eye glasses and for the control group, spoiled contact lenses were cleaned by multi-purpose solution. The remaining protein deposits on the contact lenses were determined after extraction and the changes of overall diameter, base curve, center thickness power, and water contents on contact lenses were measured and surfaces of contact lenses were observed by scanning electron microscope. Results: The cleaning efficacies of multi-purpose solution on protein deposited etafilcon A contact lenses were 6.08%, and 23.73~33.92% in the group of ultrasonic cleaner for eye glasses with multi-purpose solution and 0~12.99% in the group of ultrasonic clear for contact lens with multipurpose solution depending on the treatment time. The changes of parameters and surface on contact lenses by ultrasonication were not observed. Conclusions: Ultrasonic cleaner for eye glasses can be used to eliminate protein deposits for the diagnostic soft contact lens in the office since it was effective to eliminate protein deposits and not caused change of parameters on soft contact lenses.

The Investigation on Ultrasonic Cleaning of Soft Contact Lenses in Local Optical Shops and the Protein Removal Effect by Lens Containers (안경용 초음파세척기를 이용한 소프트렌즈 세척 실태 조사와 세척용기에 따른 단백질 제거 효과)

  • Koo, Sung Bong;Cho, Seul Bee;Park, Mijung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.1
    • /
    • pp.31-40
    • /
    • 2011
  • Purpose: This study was performed to investigate the actual state about ultrasonic cleaning of soft contact lenses in local optical shops and evaluate the removal effect of protein deposit on soft contact lenses with different lens containers by ultrasonic cleaner for eyeglasses. Methods: The actual state about ultrasonic cleaning of soft contact lenses was surveyed in total 75 local optical shops in Seoul, Korea. The cleaning efficacy of different lens containers was compared by measuring the protein remained on ocufilcon D contact lenses after washing by an ultrasonic cleaner for eyeglasses. The changes on surfaces and wetting angles of ocufilcon D contact lenses by repeat ultrasonication were further investigated. Results: The main purpose to use ultrasonic cleaners in local optical shops was rapid cleaning. The ultrasonic cleaning efficacy of ocufilcon D contact lenses with glass containers was little higher than it with plastic containers, but was not significantly different. The changes on surfaces and wetting angles of ocufilcon D contact lenses in a plastic lens container by repeat ultrasonication such as 30 and/or 60 times were shown. Conclusions: There was not significant difference in cleaning efficacy between glass and plastic lens containers. However, repeat cleaning with ultrasonic cleaner for eyeglasses would be carefully considered since some significant changes in the parameters of lens surface and wetting angles were detected by repeat ultrasonification even when lens containers were used for ocufilcon D contact lens during ultrasonictions.

회원사 탐방 - 일본, 유럽시장 등 세계 곳곳에 한국 세척기술을 심는다

  • Park, Ji-Yeon
    • The Optical Journal
    • /
    • s.119
    • /
    • pp.38-40
    • /
    • 2009
  • 일성초음파산업(대표 천홍현/www.isucl.co.kr)는 1985년 설립이래 23년간 광학전문 세척기 한 분야에서 축적해온 전문 기술력을 바탕으로 이제는 세계로 뻗어나가는 수출업체로 입지를 굳혔다. 까다롭기로 소문난 일본의 호야를 비롯한 전 세계 글로벌 회사들과 협력관계에 있는 일성초음파산업은 세계적인 광학세척기 전문업체로의 힘찬 도약을 시동하고 있다.

  • PDF

Optimization of Ultrasonic Soil Washing Processes Using Aluminum Foil Erosion Tests (알루미늄 호일 부식 실험을 이용한 초음파 토양 세척 공정 개발의 기초 연구)

  • Kim, Seulgi;Son, Younggyu
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.2
    • /
    • pp.92-98
    • /
    • 2015
  • The physical effect induced by acoustic cavitation was investigated to accumulate basic data for the design of ultrasonic soil washing processes using aluminum foil erosion tests. A square aluminum foil was placed on the glass beads in the pyrex vessel submerged in the sonoreactor equipped with a 36 kHz ultrasound transducer module at the bottom. Cavitational erosion of foils was quantitatively analyzed for various glass bead diameter conditions (1, 2, and 4 mm), glass bead height conditions (5, 10, 15, and 20 mm), and water height conditions (5, 10, 15, and 20 mm). It was found that aluminum foil erosion significantly increased as the glass bead diameter increased and water height over the glass bead increased due to less attenuation of ultrasound and the optimization of sound field for cavitation. Moreover mechanical mixing was suggested to move constantly particles to the bottom area where the acoustic cavitation occurs most violently. It was because aluminium foil erosion by ultrasound transmitted through glass beads was relatively too weak.

Removal Efficiency of Pesticide Residues on Apples by Ultrasonic Cleaner (초음파 세척기를 이용한 사과의 잔류농약 제거 효과)

  • Yoon, Chae-Hyuk;Park, Woo-Churl;Kim, Jang-Eok;Kim, Chung-Hyo
    • Korean Journal of Environmental Agriculture
    • /
    • v.16 no.3
    • /
    • pp.255-258
    • /
    • 1997
  • In order to determine the removal efficiency of pesticide residues on apples by ultrasonic cleaner, apples(Fuji var.) were artificially treated by dipping in water solution of fenitrothion EC, chlorpyrifos EC and phenthoate EC. The treated apples were washed by the ultrasonic cleaner with water, 30% ethanol solution or 0.2% detergent solution, respectively. The removal efficiency of fenitrothion, chlorpyrifos and phent-hoate by ultrasonicated washing in water for 0.5min. was 39.2%, 32.0% and 50.4%, respectively, but there was a tendency to decrease the removal efficiency of the pesticide residues as the duration of ultrasonicated washing period is increased. The maximum removal efficiency of the pesticide residues washed in the detergent solution was observed by ultrasonicated washing the samples for 5min. and it was recorded as 33.5% ; fenitrothion, 30.1% ; chlorpyrifos and 48.3% ; phenthoate, respectively. However it's appeared that the longer the ultrasonicated washing period in 30% ethanol solution the more pesticides from the apples were removed and the maximum removal efficiency of the pesticides was recorded as 66.2%(fenitrothion ; washed for 15min.), 41.7%(chlorpyrifos ; washed for 10min.), 74.2%(phenthoate ; washed for 10min.).

  • PDF

Removal of Heavy Metal and Organic Substance in Contaminated Soils by Electrokinetic and Ultrasonic Remediation (동전기 및 초음파 복원기술에 의한 오염지반내의 중금속 및 유기오염물질 제거)

  • Chung, Ha-Ik
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.3
    • /
    • pp.83-91
    • /
    • 2003
  • The electrokinetic technique has been applied to remove mainly the heavy metal and the ultrasonic technique to remove mainly organic substance in contaminated soil. In this study, the combined electrokinetic and ultrasonic remediation technique was studied far the removal of heavy metal and organic substance in contaminated soils. This study emphasized the coupled effects of electrokinetic and ultrasonic techniques on migration as well as remediation of contaminants in soils. The laboratory soil flushing tests combining electrokinetic and ultrasonic technique were conducted using specially designed and fabricated devices to determine the effect of both of these techniques. A series of laboratory experiments involving the simple, electrokinetic, ultrasonic, and electrokinetic & ultrasonic flushing test were carried out. A soil admixed with sand and kaolin was used as a test specimen, and Pb and ethylene glycol were used as contaminants of heavy metal and organic substance. An increase in out flow, permeability and contaminant removal rate was observed in electrokinetic and ultrasonic flushing tests. Some practical implications of these results are discussed in terms of technical feasibility of in situ implementation of electrokinetic ultrasonic remediation technique.

A Study on Position Control of Ultrasonic Motor Using Variable Structure Control System (가변구조 제어를 이용한 초음파 전동기의 위치제어에 관한 연구)

  • Hong, Soon-Il;Kim, Hong-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1998.07b
    • /
    • pp.546-548
    • /
    • 1998
  • 초음파는 초음파 가공기나 초음파 세척기 등에 많이 이용되고 최근 액추에트로서 초음파 전동기가 주목을 받고 있다. 압전 혹은 자기비틀림 효과를 이용하여 얻는 초음파 진동기는 전기-기계 변환효율이 다른 수단에 비하여 매우 높으므로 이것을 이용하여 얻는 초음파 진동은 왕복운동에서 직선 혹은 회전운동으로 변환시키는 연구가 행해지고 있다. 본 연구에서는 진행파 방식의 초음파 전동기를 중심으로 그 회전 원리를 이해하고 모델링 하였다. 외란에 대하여 강인한 제어방식으로 알려져 있는 가변구조제어의 이론을 이해고 회전형 진행파 방식의 초음파 전동기를 이용한 가변구조, 제어에 의한 서보계를 설계한다. 이때 제어방법은 속도패턴을 미리 정하여 두고 그 패턴에 따라 슬라이딩 모드를 사용하여 속도를 제어하여 위치를 제어하는 것이다. 초음파 전동기의 가변구조제어에 의한 위치제어를 컴퓨터 시뮬레이션으로 검토하고 제어 파라미터를 결정하였다. 그리고 인터페이스 보드를 제작하고 컴퓨터와 전동기를 접속하여 실제 제어 알고리즘을 이용하여 초음파 전동기의 제어 실험을 행하였다.

  • PDF

A Study on the Cleaning Method of Excavated Textiles (의영 전의이씨 출토복식의 세척방법에 관한 연구)

  • 박윤미;황은경;정복남
    • The Research Journal of the Costume Culture
    • /
    • v.11 no.6
    • /
    • pp.956-966
    • /
    • 2003
  • The purpose of study is to find out a suitable cleaning method for excavated textiles of Jeon-ui Lee(1570∼1647). The textiles were excavated from her tomb in 1997, and her descendents put them in a box without any treatment and kept them in the warehouse since then. We used two kinds of silk as samples, non-dyed and dyed textile. The experiment was performed by 8 kinds of wet cleaning and dry cleaning methods, an ultrasonic cleaner was used in the wet cleaning, decane and perchloroethylene were used as solvents in the dry cleaning. The use of the ultrasonic cleaner in the wet cleaning method did not show any damage to the fibers of the textiles and it not only cleaned well but also was safe for the fugitive dyes. It resulted in more effective cleaning when the detergent was used together. Therefore, it is effective to use the ultrasonic cleaning on the delicate historical textiles and helpful to the operator's safety and environment.

  • PDF

Comparisons of the Change in Soft Contact Lenses Parameters and the Cleaning Efficiency after Eyeliner Deposition (아이라이너 침착에 의한 소프트 콘택트렌즈 파라미터의 변화 및 세척효과의 비교)

  • Park, Mijung;Kim, Sa Hyun;Ku, Bo Kyoung;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.2
    • /
    • pp.107-115
    • /
    • 2013
  • Purpose: This study was conducted to investigate the change of soft contact lens parameters after eyeliner deposition and compare the cleaning efficiency and the recovery rate of lens parameters by different cleaning methods. Methods: The eyeliner was deposited on three types of soft contact lenses made of different materials for 1 hour, 4 hours and 6 hours and those lenses were washed by the eyeglasses ultrasonic cleaning and by hands. The changes in visible light transmittance, diameter and surface of those lenses were compared before and after cleaning of the lens. Results: The visible light transmittance of soft contact lenses decreased along with the deposition time of eyeliner. The patterns of the eyeliner deposition on soft contact lens appeared differently depending on the physical properties of the lens material. Thus, the largest eyeliner deposition was found on narafilcon A lens. The diameters of hilafilcon B and etafilcon A lenses were decreased, however, the diameter of narafilcon A lens was increased. The cleaning efficiency of the eyeliner deposition was greater with the multipurpose solution by hands than with the eyeglasses ultrasonic cleaner. However, the recovery of lens parameters such as the lens diameter, visible light transmittance and lens surface due to the eyeliner deposition to its original state was limited. Conclusions: From these results, it is suggested to minimize eye makeup when wearing soft contact lens. Furthermore, the reduced wearing time and shorter cycle of lens replacement may be needed by considering a change of lens parameter when the repeat eye makeup is applied.