• Title/Summary/Keyword: 초음파기기

Search Result 211, Processing Time 0.026 seconds

Development of Nondestructive System for Detecting the Cracks in KTX Brake Disk Using Rayleigh Wave (Rayleigh Wave를 이용한 KTX 제동 디스크의 균열 검측 시스템 개발)

  • Kim, Min Soo;Yeom, Yun Taek;Park, Jin-Hyun;Song, Sung Jing;Kim, Hak Joon;Kwon, Sung Duck;Lee, Ho Yong
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.37 no.1
    • /
    • pp.29-36
    • /
    • 2017
  • Recently, KTX (Korean Train Express) train stoppage accidents were mainly caused by malfunctioning equipment, aging and cracking of railway vehicles, crack breakages of brake disks, and breakages of brake disks. Breakage of brake disk can cause large-scale casualties such as high-speed collision and concern about derailment by hitting lower axle and wheel. Therefore, in this study, a brake disk with solid and ventilation type, which is the brake disk of a KTX train was modeled, and a dynamometer system was constructed to operate the disk. A Rayleigh wave was used to inspect the surface of the brake disk. An ultrasonic inspection module was developed for the brake disk by using a local immersion method due to the difficulty involved in ultrasonic inspection using an existing immersion method. In addition, the surface defects of the brake disk were evaluated using a dynamometer mock-up system and an ultrasonic inspection module of the brake disk.

Detecting the Prostate Boundary with Gabor Texture Features Average Shape Model of TRUS Prostate Image (TRUS 전립선 영상에서 가버 텍스처 특징 추출과 평균형상모델을 적용한 전립선 경계 검출)

  • Kim, Hee Min;Hong, Seok Won;Seo, Yeong Geon;Kim, Sang Bok
    • Journal of Digital Contents Society
    • /
    • v.16 no.5
    • /
    • pp.717-725
    • /
    • 2015
  • Prostate images have been used in the diagnosis of prostate using TRUS images being relatively cheap. Ultrasound images are recorded with 3 dimension and one diagnostic exam is made with a number of the images. A doctor can see 2 dimensional images on the monitor sequentially and 3 dimensional ones to diagnose a disease. To display the images, 2-d images are used with raw 2-d ones, but 3-d images need to be segmented by the prostates and their backgrounds to be seen from different angles and with cut images of inner side. Especially on detecting the boundary, the ones in the middle of all images are easy to find the boundary but the base and apex of the images are hard to do it since there are lots of uncertain boundary. So, in this paper we propose the method that applies an average shape model and detects the boundary, and shows its superiority compared to the existing methods with experiments.

Detailed Analysis for Secondary Flow Pattern Before and After Channel Bend in Actual River (실규모 하천 계측자료 기반 만곡 전후 2차류 흐름패턴 상세 분석)

  • Son, Geunsoo;Kim, Dongsu;Kim, Seojun;Kim, Jongmin
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2015.05a
    • /
    • pp.80-80
    • /
    • 2015
  • 만곡부가 연속적으로 발생하는 사행하천은 만곡의 영향으로 2차류가 발생한다. 이러한 2차류의 영향은 하상변동, 제방침식 등의 문제를 발생시켜 사행수로의 흐름특성을 분석하기 위한 많은 연구들이 진행되어 왔다. 하지만, 대부분의 연구들은 실규모 하천의 유속측정의 어려움, 측정이 가능한 시설 및 경제적 제한으로 인해 주로 실내실험에서 측정된 자료를 이용하여 분석을 수행하여 흐름조건이 상이한 실제 하천에서 적용성에 한계가 있어 왔다. 본 연구에서는 상세한 3차원 유속 측정이 가능한 최신 계측기기인 초음파도플러유속계(ADCP)를 활용하여 실제하천과 유사한 흐름 상태 및 지형을 재현한 한국건설기술연구원 안동하천실험센터의 사행도 1.2, 1.5, 1.7의 실규모 사행수로에서 횡단면 측정을 수행하였다. 또한 초음파지점유속계(ADV)를 사행도 1.2의 ADCP 측정 단면과 동일한 횡단면에서 측정하여 공간평균된 ADCP 유속자료를 이용한 흐름패턴 분석의 적용성을 검증하였다. 그 결과 공간평균된 ADCP 유속분포는 시간평균한 ADV 유속분포와 다소 크기의 차이는 발생하였지만 패턴은 매우 유사하게 나타났다. 따라서, 공간평균된 ADCP 유속분포를 이용하여 2차류에 의한 흐름패턴 분석을 수행하였다. 2차류 패턴은 만곡의 위치에 따라 매우 복잡한 형태로 나타났다. 2차류에 의한 최대유속선과 최대수심선의 발생위치를 분석한 결과, 만곡의 정점부를 기준으로 만곡 전인 유입부에서는 이격되고 만곡 후인 유출부에서는 유사한 경로를 나타내고 있었다. 이때의 2차류강도(Secondary Current Intensity; SCI)는 만곡의 정점부 부근에서 최대로 증가했다가 다시 감소하는 결과를 보였다.

  • PDF

Collection and Utilization of Hyperspectral Image Based on UAV (드론 기반 초분광 영상의 수집과 활용)

  • You, Ho Jun;Kim, Dong Su;Kim, Seo Jun
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2019.05a
    • /
    • pp.76-76
    • /
    • 2019
  • 최근 기후변화로 인해 퇴적 및 세굴이 심화되었고, 4대강 사업으로 인해 급격한 하천 지형 변화가 발생하였다. 특히, 4대강 사업 이후 하상변동 모니터링에 대한 지속적인 수요가 증가하고 있다. 이에 따라 개정된 하천법에 따르면 하상변동조사를 기본 10년 주기로 정기적으로 실시하되, 퇴적 및 세굴 발생 구간에 대해서는 기본 2년을 기준으로 하상변동이 큰 곳에 대해서는 1년 주기로, 하상변동이 작은 곳에 대해서는 5년 주기로 실시해야 한다. 하지만 기술 및 예산의 한계로 인해 하상변동조사의 경우 현장 유사량 및 하상토 입도 측정과 유량-총유사량 관계식을 활용하여 모델링을 통해 하상변동을 예측하고 있는 실정이다. 하상변동은 기본적으로 하천 수심을 기본으로 하고 있으며, 사람이 직접 투입하여 임의의 지점에 대한 수심 계측을 실시하고 있다. 하지만 직접 수심 계측의 경우 낮은 자료의 밀도로 인해 많은 인력과 예산, 시간이 소요되며 무엇보다도 관측 대상인 물이라는 작업환경에서는 인명피해가 발생할 수 있는 문제점을 가지고 있다. 최근에는 이러한 한계를 극복하기 위해 초음파 센서가 탑재된 이동식 보트를 활용하여 경로형 수심 계측을 실시하고 있으나, 초음파 센서가 가지는 기기적 한계로 인해 약 50cm 이하에 대한 수심은 측정이 어려운 실정이다. 특히, 국내 하천의 경우는 홍수기를 제외하면 수심이 얕기 때문에 얕은 수심에 대한 자료 확보가 어려워 공간적 정밀도 확보가 어려운 실정이다. 따라서 기존의 하천계측의 패러다임을 지점, 선형 계측이 아닌 면 측량을 실시를 통해 높은 밀도의 자료를 확보해야 한다. 이러한 측량이 가능한 기술로 하천원격탐사가 대안으로 제시되고 있다. 하천원격탐사는 직접 접촉하지 않고, 대상체의 광학적 특성을 통해 물리적 특성을 파악하는 기술로서 적은 시간에 높은 밀도의 자료의 확보와 저예산의 고효율 방법으로 알려져 있다. 본 연구에서는 기존의 하천원격탐사에서 활용한 고비용, 저해상도의 시공간 스케일에 해당하는 위성 및 유인항공기가 아닌 하천의 흐름방향으로 비행이 가능하고 상대적으로 저비용, 고해상도의 시공간 스케일의 측정이 가능한 드론을 활용하여 하천원격탐사를 수행하는 방법에 대해 논하고자 한다. 특히, 기술적 한계가 존재하는 청색, 녹색, 적색에 해당하는 RGB 영상을 활용한 하천원격탐사를 극복하기 위한 대안으로 초분광 영상을 수집하고 활용하는 방법을 제시하고자 한다.

  • PDF

A Study on Pulse Pattern Using Ultrasonic Device (초음파기기를 이용한 맥상(脈象) 연구)

  • Kim, Hee Young;Park, Jeongbin;Keum, Yujeong;Yeo, Inkeum;Eom, Dongmyung;Song, Jichung
    • Journal of Korean Medical classics
    • /
    • v.34 no.2
    • /
    • pp.85-94
    • /
    • 2021
  • Objectives : Pulse diagnosis is one of the main diagnostic methods of Korean Medicine that understands the patient's condition and illness by reading changes in the patient's pulse, which is described in terms of pulse condition While they are described in detail in medical texts, it is difficult to grasp their true nature, as the written descriptions fail to do justice to the experience of pulse taking it tries to convey. As a way to approach pulse condition the effect of the body's tension on the radial vein was measured using an ultrasonic device, after which the measured changes and how they could be reflected in pulse condition were studied. In other words, changes in the radial vein following induced tension were analyzed. Methods : 1) The thickness of the subject's radial vein was measured using a linear probe of an ultrasonic device[LOGIQ 5 Basic, GE, USA]. 2) Fatigue level was increased through artificial stimulation using the Gripmeter[ks-301, Lavisen, Korea]. 3) Thickness of the radial vein post tension induction was measured. 4) The results were analyzed with the Tukey test or paired t-test as post hoc tests. Results : Thickness of the radial vein of the subject pre- and post- Gripmeter stimulation decreased with significance. Conclusions : Constriction of the radial vein that happened after tension induction could be linked to the Tight Pulse[緊脈] that is related to patterns of contraction and pulling.

Interface Conversion to Extend Communication Cable of Ultrasonic Sensor (초음파 센서 통신선 연장을 위한 인터페이스 변환)

  • Seo, Dae-Il;Kwon, Byung-Hyuk;Kim, Sang-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.3
    • /
    • pp.467-472
    • /
    • 2022
  • The 3D ultrasonic anemometer transmits measured data by connecting PC and RS232C interface. Depending on the observation location, it is often necessary to extend the cable connecting the PC and the sensor. When installing on the test bed of the Air Meteorological Agency, the original AWM2919 cable was required to be extended because the distance between the PC container and the equipment installation site was more than 30 m. The cable was extended through a process such as extending the AWM2919 cable, converting the interface with the PC from RS232C to RS485, and testing the RS485 communication. After the equipment was installed with an extended cable, data were remotely collected and analyzed to confirm successful cable extension.

Musculoskeletal Ultrasound Findings of Shoulder Pain Patients: A Retrospective Observational Study (근골격계 초음파 진단기기를 활용한 견관절 통증 환자의 초음파 소견: 후향적 관찰 연구)

  • Hyun-Tae Kim;Hye-Jin Park;Yeon-Woo Lee;Sun-Young Park;In Heo;Eui-Hyoung Hwang;Byung-Cheul Shin;Man-Suk Hwang
    • Journal of Korean Medicine Rehabilitation
    • /
    • v.33 no.2
    • /
    • pp.77-85
    • /
    • 2023
  • Objectives The aim of this study is to retrospectively evaluate the shoulder lesions in patients experiencing shoulder pain through the use of musculoskeletal ultrasound during Korean medicine intervention treatments. Methods A total of 20 cases were collected, including biceps tendinitis (n=4), calcification (n=3), SASD bursitis (n=4), partial tear (n=2), full-thickness tear (n=1), tendinopathy (n=5), and impingement syndrome (n=1). Musculoskeletal ultrasound was used by Korean medicine doctors to perform real-time scanning and to explain the patient's condition during treatment sessions. Results The use of musculoskeletal ultrasound allowed Korean medicine doctors to perform treatments such as pharmacoacupuncture, acupotomy, and acupuncture more safely and effectively. Patients were able to better understand their conditions through real-time imaging and explanations provided by the doctors. Conclusions Musculoskeletal ultrasound has the potential to enhance the safety and efficacy of Korean medicine intervention treatments for patients with shoulder pain. Institutional or governmental support is needed to further promote the use of medical devices by Korean medicine doctors, ultimately leading to an increase in cases and clinical evidence.

Estimation of maximum measurable depth using hyperspectral image (초분광 영상을 활용한 최대추정가능수심 산정 기법 개발)

  • Seo, Youngcheol;Kim, Dongsu;You, Hojun;Kwon, Yeonghwa
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2022.05a
    • /
    • pp.444-444
    • /
    • 2022
  • 하천 수심 계측은 수심을 사람이 직접 계측하거나 초음파 기반 유속계 (ADCP) 등 최신 계측기기를 이용하여 간접적으로 계측을 실시하고 있다. 하지만 사람이 직접 하천에서 수심을 측정하는 것은 위험이 동반되고, 수심자료의 측정오차가 크게 발생한다. 따라서 수심측정에서 직접 측정 방식의 한계를 극복하기 위해, 초분광 영상의 반사도와 수심이 높은 상관관계를 보이는 것을 활용하여, 초분광 영상 기반 수심 산정 기법을 개발하였다. 초분광 영상 기반 수심 산정 기법은 복수의 파장이 존재하는 초분광영상으로부터 두 개의 파장대의 밴드를 추출하여 모든 경우의 수에 대해 밴드비를 산정한 후, 실측수심과 밴드비 간의 회귀분석을 실시하여 상관계수가 가장 높은 회귀식을 찾아내는 방식이 최적 밴드비 분석법에 기반한다. 최적 밴드비 분석법을 통해 획득된 높은 상관성의 밴드비-수심 관계식을 이용하여 수심을 추정할 수 있다. 이러한 방법은 직접 수심 측정 방식에 비해, 높은 해상도와 밀도, 양질의 데이터를 수집할 수 있는 장점이 있다. 과거 연구에 따르면 저수심부에서의 높은 정확도의 수심추정 결과를 보였지만, 고수심부에서는 실측수심과의 오차도 높아지는 등 정확성이 떨어지는 경향을 보인다. 따라서 본 연구에서는 보다 효율적인 수심계측을 할 수 있도록 최적 밴드비 분석법을 활용한 수심추정에서 신뢰성 있는 수심의 범위를 파악할 수 있는 방법을 제시하고자 한다. 본 연구에서는 대상지역으로 낙동강 본류와 황강 지류 합류부로 선정하였고, 초음파 기반 유속계(ADCP)와 드론을 활용하여 실측수심과 초분광 영상을 취득하였다. 민감도 분석을 위한 수심자료를 0.5m 단위로 분할하였으며, 구간별로 최적 밴드비 분석을 실시하였다. 그 결과, 구간별로 산정된 상관계수와 평균제곱근오차 (RMSE)를 통해 정확도가 높은 구간을 구별할 수 있었다. 또한 해당 구간을 초과하는 수심은 초분광 영상을 통해 추정이 어려운 것으로 판단되며, 분석한 구간까지를 최대 추정 가능 수심으로 정의하였다. 마지막으로 검증을 위해 최대추정가능수심으로 판단된 구간까지의 데이터만 활용하여 최적 밴드비 분석법을 적용하여 상관계수나 평균제곱근오차 결과의 개선여부 확인을 통해, 본 연구에서 제시한 방법이 정확한 최대추정가능수심 구간을 산정할 수 있는지 확인하였다.

  • PDF

Practical Applications of DNA Marker-Assisted Selection and OPU-Derived IVF Embryo Transfer for the Production of High Quality Meat in Hanwoo I. Collection of Follicular Oocytes with Ultrasound-Guided Transvaginal Ovum Pick-Up from DNA Marker-proved Hanwoo (유전자 분석을 통하여 선발된 한우로부터 초음파 유래 체외수정란 이식에 의한 고품질 한우 생산기술의 실용화 I. DNA 검정우에서 초음파기기를 이용한 난포란의 채란에 관한 연구)

  • 박희성;이지삼;진종인;박준규;홍승표;이명열;정장용
    • Journal of Embryo Transfer
    • /
    • v.16 no.3
    • /
    • pp.183-191
    • /
    • 2001
  • This study was designed to establish the superior method for IVF embryos from DNA marker-proved Hanwoo cattle. DNA markers related to marbling score were identified using DNA fingerprinting with Ml3 probe and restriction enzyme Hae III. Oocytes were aspirated from unstimulated. immature ovarian follicles using a combined method of rectal ovarian-palpation and transvaginal ultrasound-guidance(6.5MHz) under local abesthesia. The aspirated oocytes were washed twice with fresh D-PBS containing 5% FBS and were rewashed 4 to 5 times with TCM-199 containing 5% FBS. A morphological grade of I to IV was assigned to each oocyte. Data were analysed using the GLM procedure of SAS. Mean number of follicles identified on ultrasound was 5.5 $\pm$2.9 in right and 4.3 $\pm$2.8 in left ovaries, respectively. The highest follicles(16.6$\pm$2.6) were found in 5101 cow compared to others. Recovery rate of follicular oocytes in individual cow was highest in 5101 cow with 89.3% in > 2mm and 94.0% in $\leq$ 2mm follicles. Total recovery rate was significantly(P<0.01) higher in $\leq$ 2mm(85.7%, 130/154) than > 2mm follicles(74.2%, 201/271). Significantly more oocytcs of Grade IV were recovered from > 2mm follicles. Mean number follicles recovered was 4.8$\pm$3.7. 3.0$\pm$3.4 and 0.3$\pm$0.6 in $\leq$2mm, 2~6mm and $\geq$6mm follicles. respectively. Our results imply that the more fertilizablc oocytes can be recovered from invisible-immature follicles by the combination of simultaneous rectal ovarian-palpation and ultrasound-guided approach in Hanwoo cattle.

  • PDF

Clinical Usefulness of Chest Wall Ultrasonography for Detecting Fractures of Costal Cartilage due to Minor Blunt Chest Trauma (경미한 둔상에 의하여 야기되는 늑연골 골절 진단에 있어서 흉벽 초음파 검사의 임상적 유용성)

  • Lee, Woo-Surng;Kim, Yo-Han;Chee, Hyun-Keun;Hwang, Jae-Joon;Lee, Song-Am;Jung, Ho-Sung;Shin, Hyun-Joon;Choi, Young-Chill
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.502-508
    • /
    • 2009
  • Background: Rib fractures are the most common injuries that are caused by blunt chest trauma. However, fractures of the costal cartilage generally go unnoticed on chest X-rays unless they involve a calcified cartilage. For this reason, the sensitivity of conventional radiography for detecting rib fractures is low, and especially those involving the cartilaginous part of the rib. Thus, we have evaluated the usefulness of ultrasonography for detecting fractures of the costal cartilage that were overlooked on the conventional radiographs of patients who suffered minor blunt chest traumas. Material and Method: A total of 45 patients who suffered minor blunt chest trauma and who had no evidence of rib fractures or other major fractures on conventional radiographs were admitted for ultrasonography between April 2008 and March 2009. There were 24 women and 21 men, and the mean age of the patients was 50.4$\pm$15.91 years (range: 17$\sim$76 years). They were examined for the detection of fractures of the costal cartilage by performing ultrasonography with a 7.5-MHz linear transducer. Result: A total of 30 patients (67%) had fractures of the costal cartilage, whereas 15 patients (33%) had no evidence of chondral rib fractures. The mean number of fracture sites of the fractured costal cartilage was 1.6$\pm$0.81 (range: 1$\sim$4 sites) in 30 patients. Periosteal hematoma was the most common finding associated with fractures of the costal cartilage (n=7, 17%), followed by sternum fracture (n=5, 12%). However, periosteal hematoma was noticed in 1 patient (2%) who was without fracture of the costal cartilage, and sternum fracture was noticed in 1 patient (2%) who was without fractures of the costal cartilage. Conclusion: The results of this study suggest that ultrasonography may be a useful imaging modality for detecting fractures of the costal cartilage that are overlooked on the conventional radiographs of patients who suffer minor blunt chest trauma.