• Title/Summary/Keyword: 체크 밸브

Search Result 61, Processing Time 0.022 seconds

Development and Validation of Wheel Loader Simulation Model (휠로더 시뮬레이션 모델의 개발과 검증)

  • Oh, Kwangseok;Yun, Seungjae;Kim, Hakgu;Ko, Kyungeun;Yi, Kyongsu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.5
    • /
    • pp.601-607
    • /
    • 2013
  • This paper presents the development and validation of a wheel loader simulation model. The objective of doing so is to evaluate the performance of the wheel loader and improve its overall performance using Matlab/Simulink. The wheel loader simulation model consists of 4 parts: mechanical/hydraulic powertrain model and vehicle/working dynamic model. An integrated simulation model is required to evaluate and improve the performance of the wheel loader. It is expected that this model will be applied to fuel economizing, improving the pace of operation by using the hybrid system, and the intelligent wheel loader. The performance of the proposed simulation model has been validated by using Matlab/Simulink to compare the driving and the working experimental data.

Analysis of Dynamics Characteristics for Friction Elements in Automatic Transmission (자동변속기 마찰요소의 동특성 해석)

  • 최영종;정우진;김성원
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.5 no.5
    • /
    • pp.9-19
    • /
    • 1997
  • In this paper, the modeling and analysis of dynamic characteristics has been carried out for friction clutches and brakes in an automatic transmission. From the operating oil pressure generated by the valve-body, time delay by check valve and the movement of piston has been examined. Also torque capacity and torque transferred at the clutch is studied. Heat capacity and temperature distribution at the reaction plate of clutch are codeled by time-dependent, nonhomogeneous partial differential equation, and brake torque, brake time, and the amount of heat generated are investigated. It is found that the time delay at the check valve is very short but dominant at the spool.

  • PDF

Flow Analysis of Cryogenic Check Valve for LNG (냉열발전을 위한 극저온 체크밸브의 유동해석)

  • Moon, Jung-Hyun
    • Journal of Power System Engineering
    • /
    • v.20 no.1
    • /
    • pp.5-10
    • /
    • 2016
  • Swing check valve is opened when the flow direction is forward, when the flow is reversed, the valve is automatically closed by back pressure. In this study, the internal flow field analysis of the valve was conducted by Fluent. The working fluid used in the study, using liquefied methane $-165^{\circ}C$ (CH4) and velocity field, pressure field, pressure drop coefficient were simulated by varying separately the opening divergence into four intervals from 0 to 100%. The approximate research result are as follow : When the opening divergence is smaller, it appears high pressure on the upstream side, this value is relaxed when the opening divergence is large. Flow rate coefficient of the valve shows a larger value as the degree of opening becomes larger, confirming that the check valve used in the study is in the effective flow rate counting range.

Flow Analysis of Check Valve for Hydrogen Vehicle Refueling Line (수소자동차의 연료주입라인용 Check Valve 내의 유동해석)

  • Park, Kyong-Taek;Yeo, Kyeong-Mo;Park, Tae-Jo;Kang, Byeong-Roo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.565-568
    • /
    • 2007
  • The high pressure hydrogen gas refueling system is required for fuel cell vehicle. In this paper, a commercial computational fluid dynamics (CFD) code, FLUENT is adopted to investigate the gas flow characteristics inside the check valve for various refueling and tank pressures. The results showed that the choking phenomena can occur for certain refueling pressures, therefore refueling processes should be divided by multiple stages. And a design method to prevent the seal departure problem which reported in CNG usages is required.

  • PDF

Unsteady Flow Analysis of Oil Jet for Cooling the Piston (피스톤 냉각용 오일제트 비정상 유동 해석)

  • Kwon, Ji-Hyuk;Lee, Yeon-Won;Kim, Jae-Wan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.2
    • /
    • pp.1-7
    • /
    • 2008
  • In order to enhance the performance of an automotive engine, many researchers have been carried out. An oil jet cooling a piston is one of important parts for engine performance. Therefore, the efficient cooling system of an oil jet is needed. In this paper, unsteady flow analysis of the oil jet which consists of a check valve and a nozzle has been accomplished. And the reaction between mass flow rate and ball movement was also investigated.

DESIGN OF A CHECK VALVE FOR FEEDING BIOLOGICAL CELLS ONE BY ONE (세포의 개별 공급을 위한 체크 밸브의 설계)

  • Choi, Jung-Hoon;Lee, Sang-Wook;Kim, Yong-Kweon
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.85-87
    • /
    • 1994
  • Feeding biological cells one by one is the key point in the manipulation of cells. The conventional valve systems have many difficulties in feeding cells one by one, because they shut the whole flow of fluids when they are closed and have possibilities of breaking the fragile cells. They need some other equipments for continuous supply of suspension and to protect the cells. We design a check valve for feeding biological cells one by one using polyimide all the silicon substrate. The cells are fed by hydraulic pressure through the isotropically etched cavity. When the suspension flows continuously along the channel the valve is bent by hydraulic pressure and a cell is fed to the outlet. We have studied a cell fusion device fabricated with polyimide and electroplating. If the designed check valve is located in front of the cell fusion device it is helpful to fuse two different kinds of cells.

  • PDF

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Proceedings of the SAREK Conference
    • /
    • 2008.06a
    • /
    • pp.163-170
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.

  • PDF

A Study on the Nonlinear Behavior of Check Valve System (체크밸브의 비선형거동에 관한 연구)

  • 박철희;홍성철;박용석
    • Journal of KSNVE
    • /
    • v.4 no.2
    • /
    • pp.221-230
    • /
    • 1994
  • This paper deals with the dynamic stability and the nonlinear behavior of a check valve system. The nonlinear equations of motion of fluid-valve interation model are derived, which are composed of the unsteady Bernoulli's equation included the jet flow mechanism and equation of motion of a check valve formulated by one degree of freedom. Also, the derived equations of motion are nondimensionalized. According to the change of the nondimensional parameters, the stabilities of the system are analyzed, and the nonlinear interaction responses of the check valve and the passing flow rate are obtained. As the results, the stability charts are constructed for the variation of nondimensional parameters. It is shown that self-excited vibrations exist in a check valve system. And also the Hopf bifurcation and the periodic doubling are found. The presented theoretical model of a check valve system can be utilized to the design and operation of a piping system with the check valve.

  • PDF

Dynamic Characteristics of Clutch System for an Automatic Transmission (자동변속기 클러치 시스템의 동특성 해석)

  • Kim, Ju Hwan;Kim, Hyun-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.1
    • /
    • pp.284-294
    • /
    • 1996
  • In this paper, dynamic characteristics of an AT clutch system were investigated considering the dynamics of check ball and hydraulic control valves. Dynamic model of a pressure control solenoid valve (PCSV) was obtained by Bondgraph and permeance method. Also, the clutch piston and check ball dynamics were modeled by considering the effect of centrifugal force of the oil entrapped in the clutch chamber. In order to validate the dynamic models obtained, plunger displacement of PCSV and pressure response of the clutch supply lines were compared with the available experimental data, which were in good accordance with the numerical results. Using the dynamic model of the clutch system, simulations were performed to investigate the effect of the rotational speed on the response of clutch cylinder pressure, clutch piston and check ball displacement, and oil flow rate into the cylinder and flow rate out of the check valve.

Performance of a Reciprocating Compressor Equipped with Auxiliary Port (보조 흡입구가 장착된 왕복동 압축기의 성능 분석)

  • Lee, Yong-Ho;Kim, Hyun-Jin
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.10
    • /
    • pp.637-644
    • /
    • 2008
  • Auxiliary port which had been known to be used to reduce the expansion loss of a refrigeration system was applied to a R134a reciprocating compressor in a household refrigerator cycle with an intention of improving the compressor performance. Effects of the auxiliary port on the compressor performance was investigated by a computer simulation program. When a simple hole was made on the side wall of the cylinder as an auxiliary port and surrounding gas inside the compressor shell was assumed to be drawn into the cylinder through the hole, maximum COP improvement of 1.66% was obtained. With auxiliary port equipped with a plate type of check valve, maximum COP was raised to be 1.99%. COP improvement was more distinctive with decreasing the discharge pressure; COP improvement was 5% with discharge pressure of 7 bar.