• Title/Summary/Keyword: 체적-표면적 평균직경

Search Result 5, Processing Time 0.017 seconds

An Experimental Study on the Spray Characteristics of Internal Mixing Atomizer for Twin Fluid (내부혼합형 2유체 미립화기의 분무 특성에 관한 실험적 연구)

  • Kim, K.C.;Ha, M.H.;NamKung, J.H.;Lee, S.G.;Rho, B.J.;Kang, S.J.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.693-698
    • /
    • 2001
  • An experimental study was carried out with an aerated nozzle. This nozzle was well known that the performance of the atomization is better than other ones even though the supplied air pressure is lower than that of them. The purpose of this investigation is to provide the essential information of the aerated nozzle from the nozzle exit. The experimental work was performed in order to analyze the characteristics of the overall flow field from the nozzle exit. The 2-D PDPA system was used to acquire the data in the concerned region. The characteristics of the mean velocity distribution, half-width, and SMD were mainly analyzed. Also the correlation between turbulent kinetic energy and SMD was described with ALR.

  • PDF

A Study on the Statistical Analysis of the Flow Characteristics of Droplet in the Cross Region of Twin Spray (이중분무 교차지역에서의 액적유동특성의 통계학적 분석에 관한 연구)

  • 조대진;윤석주;최태민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.3
    • /
    • pp.635-644
    • /
    • 1994
  • This study investigated mainly on the flow characteristics of a droplet in the cross region of twin spray. The velocities of the droplet were measured along the axial and radial direction, and the flow characteristics of the droplet were statistically analyzed. For the statistical analysis, the probability density of the turbulent components has been studied, and then the Reynolds shear stress, the skewness and the flatness factors were calculated, and compared with the Gaussian value. Two pressure swirl stomizers were used for the twin spray system and kerosene was employed as the working liquid. 2-D PDA(particle dynamic analyzer) was used for the purpose of the measurement of droplet size and velocities. As a result, it was found that (1) the droplets collision was taken place strongly in the cross region. So, a large momentum loss of droplets due to the loss of natural movement direction was occurred, and momentum loss of radial direction was greater than that of axial direction. (2) The axial direction skewness factor approached to zero like the Gaussian distribution in the cross region of twin spray. (3) In the cross region of twin spray, the fluctuation instability of droplet was increased because of the development of the turbulence characteristics due to the droplet collision.

A Study on the Atomizing Mechanism for the Swirl Nozzle (와권(渦卷) 노즐의 무화기구(霧化機構)에 관(關)한 연구(硏究))

  • Lee, Sang Woo;Sakai, Jun;Ishihara, Akira
    • Korean Journal of Agricultural Science
    • /
    • v.14 no.1
    • /
    • pp.81-97
    • /
    • 1987
  • Two nozzles with different size (Figure 2) were particularly designed to supply air through the swirl core into the central part of the liquid stream in the same parallel direction to produce a well-mixed air and water in the whirl chamber as spray liquid in bubble formation. Atomization was attempted to improve by using both the preliminary break-up process with less viscosity and less surface tension in the whirl chamber and the effects of increased frequency of the band of drops with the raised ambient air density in front of the nozzle orifice. The volumetric ratio between spray liquid and air on four levels was used to investigate the effects of air as a component of the mixture on atomization. The results of the experiment were summarized as follows; Droplet size became progressively finer as the operating pressure was increased in the range of $0.70kg/cm^2$ to $6.33kg/cm^2$, which was similar to the previous works. The new atomizing mechanism so-called 'air-center nozzle' gave a narrower range in droplet size distribution with smaller volumetric median diameter (VMD) than that of the existing spray system at a given pressure, which showed the possibility of improvement of atomization in a certain limit. The volumetric median diameter produced by the new atomizing mechanism was decreased from the central region toward the exterior edges across the spray pattern.

  • PDF

Spray Structure and Cross-section Characteristics of Pulsed Liquid Jet Injected into a Cross-flow (횡단 유동장으로 펄스 분사된 액체 제트의 분무 구조 및 단면 분포 특성)

  • Lee, In-Chul;Koo, Ja-Ye
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.13 no.2
    • /
    • pp.1-8
    • /
    • 2009
  • Present studies of these experiments was conducted to using water, over a range of cross-flow velocities from 42 to 136 m/s, with injection frequencies from 35.7 to 166.2 Hz. In cross-flow field, main parameters of liquid jet for secondary breakup were cross-flow drag rather than pressure pulse frequency. As oscillation of the periodic pressure, liquid jet was moved up and down. Also, a bulk of liquid jet puff was detected at upper field of liquid surface. Because of pressure pulsation frequency, an inclination of SMD for the structured layer was evanescent. Cross-sectional characteristics of SMD at downstream area were non-structured distributions. The tendency of volume flux value for various frequency of pressure pulse was same distribution. And volume flux was decreased when the frequency of pressure pulse increasing.

Effects of Physical Factors on Urban Surfaces on Air Quality - Chang Chun, China as an Example - (도시표면의 물리적 요소가 대기질에 미치는 영향 - 중국 창춘을 사례로 -)

  • Jin, Quanping;Kim, Tae Kyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.49 no.5
    • /
    • pp.1-11
    • /
    • 2021
  • The purpose of this study is to find out the main factors affecting air quality in urban physical space factors, and provide clues for environmental improvement. Nine monitoring stations in China's industrial city, Changchun, collected AQI concentration data from January 1, 2018 to December 31, 2019. This paper analyzes the types and distribution characteristics of urban physical facilities within a radius of 300m with the detection station as the center. The monitoring station is divided into three groups, and the difference in floating dust concentration among the three groups in different seasons is analyzed. The results show that AQI concentration is the highest in spring and winter, followed by summer, and the lowest in autumn. The place with the highest concentrations of AQI in spring are F (93.00), D (91.10), I (89.20), in summer are D (69.05), A (67.89), B (84.44), in autumn are I (62.80), G (60.84), D (53.27), D (53.27), in winter are I (95.82), H (95.60), f (94.04). Through SPSS analysis, it shows that the air index in a space with a diameter of 600 meters is related to forest land, grassland, bare land, water space, tree height, building area (average value), and building volume (average value). According to the statistical analysis results of spring and winter with the most serious pollution, forest land area (43,637m2, 15.44%) and water surface area (18,736m2, 6.63%) accounted for the majority, and group 1 (A, B, C) with the least average building area (448m2, 0.17%) and average building volume (10,201m2) had the lowest pollution concentration. On the contrary, group 2 (D, E, F) had the highest AQI concentration, with less or no woodland (1,917m2, 0.68%) and water surface area (0m2, 0%), and the highest average building area (1,056m2, 0.37%) and average building volume (17,470m3). It is confirmed that the characteristics of the area with the highest AQI concentration are that the more the site ratio of tree height above 12m, the smaller the site ratio of bare land, and the lower the pollution degree. On the contrary, the larger the area of bare land, the higher the pollution degree. By analyzing the characteristics of nine monitoring stations in Changchun, it can be seen that the air quality brought by the physical characteristics of urban space is closely related to the above factors.