• Title/Summary/Keyword: 체외순환보조장치

Search Result 19, Processing Time 0.024 seconds

Development of Bubble Detector for Extracorporeal Circulation Support System (체외 순환 보조 장치 위한 공기방울 감지 장치 개발)

  • Lee, Hyuk-Soo
    • Journal of the Institute of Convergence Signal Processing
    • /
    • v.11 no.4
    • /
    • pp.298-302
    • /
    • 2010
  • Extracorporeal circulation support system is a device for repiratory and heart failure treatment, and there have been many trials for development and clinical application in the world. These devices need to be careful while using is air embolism. Air embolism can be a lethal complication of surgical procedures during which venous pressure at the site of surgery is sub-atmospheric or air is forced under pressure into a body cavity or using extracorporeal circulation support system. To solve the problem, we developed the air detector using relative dielectric constant change. In experiments with a mock circulation system, the proposed system showed a signal difference depending on the amount of air in the tube.

Percutaneous Cardiopulmonary Support (PCPS) for Patients with Cardioppulmonary Bypass Weaning Failure during Open Heart Surgery (개심술 중 심폐기 이탈에 실패한 환자에게 적용한 경피적 심폐순환 보조장치)

  • Ryu, Kyoung-Min;Park, Seong-Sik;Seo, Pil-Won;Ryu, Jae-Wook;Kim, Seok-Kon
    • Journal of Chest Surgery
    • /
    • v.42 no.5
    • /
    • pp.604-609
    • /
    • 2009
  • Background: Recently, percutaneous cardiopulmonary support (PCPS) has been widely used to rescue patients in cardiogenic shock or cardiac arrest. However, patients with cardiopulmonary bypass (CPB) weaning failure during open heart surgery still have very poor outcomes after PCPS. We investigated clinical results and prognostic factors for patients who underwent PCPS during open heart surgery. Material and Method: From January 2005 to December 2008, 10 patients with CPB weaning failure during open heart surgery underwent PCPS using the CAPIOX emergency bypass system ($EBS^{(R)}$, Terumo Inc, Tokyo, Japan). We retrospectively reviewed the medical records of those 10 patients. Result: The average age of the patients was $60.2{\pm}16.5$ years (range, $19{\sim}77$ years). The mean supporting time was $48.7{\pm}64.7$ hours (range, $4{\sim}210$ hours). Of the 10 patients, 6(60%) were successfully weaned from the PCPS While 5 (50%) were able to be discharged from the hospital. Complications were noted in 5 patients (50%). In univariate analysis, long aortic cross clamp time during surgery, mediastinal bleeding during PCPS and high level of Troponin-I before PCPS were significant risk factors. All of the discharged patients are still surviving $34{\pm}8.6$ months (range, $23{\sim}48$ months) post-operatively. Conclusion: The use of PCPS for CPB weaning failure during open heart surgery can improve the prognosis. More experience and additional clinical studies are necessary to improve survival and decrease complications.

The In-hospital Clinical Outcomes of Extracorporeal Life Support after Adult Cardiovascular Surgery (성인 심혈관 수술 후 시행한 체외순환보조의 조기 임상결과)

  • Yie, Kil-Soo;Na, Chan-Young;Oh, Sam-Sae;Kim, Jae-Hyun;Ryu, Se-Min;Park, Sung-Min;Cho, Seong-Joon
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.464-472
    • /
    • 2009
  • Background: We analyzed the clinical results and the factors for survival of patients who underwent extracorporeal life support system after adult cardiovascular surgery. Material and Method: We retrospectively reviewed the medical record of 44 patients (1.6% of the total adult cardiovascular surgical cases) who underwent the use of a ventricular assisted device or extracorporeal membrane oxygenation from January 2002 to August 2008. There were 32 (72.7%) males and their mean age was 61.7$\pm$14.9(range: 20$\sim$73) years old. The mean duration of extracorporeal life support system was 5.3$\pm$3.0 (range: 1$\sim$12) days. Result: Of these 44 patients, 24 (54.5%) patients were successfully weaned from the extracorporeal device. Eighteen (40.9%) survivors were able to be discharged from the hospital. Complications were noted in 38 patients (86.4%). An emergency operation, no usage of a concomitant intraaortic balloon pump and major complications during use of the extra corporeal life support system such as bleeding, flow instability and renal failure were identified as significant risk factors for poor survival on univariated analysis. Owing to educational support and a continuous renal replacement therapy system, the clinical outcomes of these patients have improved since 2006. On multivariated analysis, renal failure and bleeding during extracorporeal life support were significant risk factors for poor survival. Conclusion: Although using. extracorporeal life support systems after adult cardiovascular surgery revealed acceptable clinical results, determining the optimal treatment strategy and further well designed larger studies are needed to improve the survival rate of patients who undergo extracorporeal life support after adult cardiovascular surgery.

Extracorporeal Life Support with a Twin-pulse Life Support (T-PLS) System (이중 박동성 인공심폐기(Twin-Pulse Life Support, T-PLS)를 이용한 심폐순환보조)

  • Lee, Dong-Hyup;Lee, Jang-Hoon;Jung, Tae-Eun
    • Journal of Chest Surgery
    • /
    • v.40 no.7 s.276
    • /
    • pp.512-516
    • /
    • 2007
  • A mechanical circulatory support system is a life-saving option for treating acute severe respiratory failure or cardiac failure. There are currently a few types of assist devices and the Twin-Pulse Life Support (T-PLS) system is a kind of pulsatile pump. We report here on three patients with severe life threatening cardiopulmonary dysfunction who had the T-PLS system used as an assist device. The indications for applying the T-PLS system were continuing respiratory or cardiac failure in spite of maximal ventilatory and inotropic support. There were two patients with acute respiratory failure due to infection and one patient with cardiac failure due to acute myocarditis. One respiratory failure patient and one cardiac failure patient survived after applying the T-PLS system for 3 days and 5 days, respectively. The T-PLS system is useful as an assist device and it should be considered before multi-organ failure occurs.

The Application of a Bi-ventricular Assist Device for a Low Weight (2.4 kg) Neonate with Coarctation of the Aorta and Critical Aortic Stenosis (대동맥 축착증 및 심한 대동맥 협착을 가진 저체중 신생아(2.4 kg)의 수술 전후 발생한 심실 기능 부전의 치료에 대한 양심실 보조 장치 적용 치험 예)

  • Kwak, Jae-Gun;Park, Chun-Soo;Lee, Chang-Ha;Lee, Cheul
    • Journal of Chest Surgery
    • /
    • v.43 no.3
    • /
    • pp.304-307
    • /
    • 2010
  • A 5-day-old neonate (body weight=2.4 kg) with coarctation of the aorta and critical aortic stenosis underwent an interventional balloon valvuloplasty for aortic stenosis. During the intervention, cardiac arrest occurred due to injury of the right carotid artery by the guide wire. An extracorporeal membrane oxygenator (ECMO) was applied. After 1 day's support, total surgical correction was achieved; however, in the immediate postoperative period, cardiac function was severely depressed. We applied a bi-ventricular assist device (bi-VAD) instead of an ECMO and we were able to wean the patient off the bi-VAD device after 3 days' support. The patient was discharged without severe complications.

Successful Rescue of Refractory Ventricular Tachycardia after One and a Half Repair in Ebstein's Anomaly by Extracorporeal Membrane Oxygenation (부분 양심실 교정을 받은 엡스타인 기형에서 발생한 심실성 빈맥에 대해 체외막 산소화 장치를 이용한 성공적인 구출)

  • Seo, Hong-Joo;Whang, Sung-Wook;Lee, Cheul;Lim, Hong-Gook;Yu, Jai-Kun;Lee, Chang-Ha
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.220-224
    • /
    • 2007
  • Extracorporeal membrane oxygenation (ECMO) provides mechanical cardiopulmonary support and has been used for children with severe respiratory failure, intractable heart failure, sepsis, pulmonary hypertension, and as a bridge to heart transplantation. There have been few reports of the use of ECMO to provide cardiac support in children with low cardiac output as a result of arrhythmias. We report the case of a 15-year-old female with circulatory collapse due to refractory ventricular arrhythmia after one and a half repair in Ebstein's anomaly, who was successfully resuscitated using ECMO.

Sequential Bilateral Lung Transplantation with Extracorporeal Membrane Oxygenation (ECMO) Support - A case report - (체외막 산소화 장치를 이용한 순차적 양측 폐이식 수술 치험 - 1예 보고 -)

  • Lee, Mina;Kim, Kwhanmien;Sung, Ki-Ick
    • Journal of Chest Surgery
    • /
    • v.43 no.1
    • /
    • pp.96-99
    • /
    • 2010
  • Artificial lung support may be necessary in various conditions during the performance of bilateral lung transplantation, and cardiopulmonary bypass (CPB) has usually been used. Yet using the conventional CPB techniques may increase risk of bleeding and early allograft dysfunction due to the large dosages of heparin and the complement activation. Extracorporeal membrane oxygenation (ECMO) is able to support gas exchange and maintain the hemodynamics without administering high-dose heparin for anticoagulation. We performed sequential bilateral lung transplantation with ECMO support. ECMO is a valuable tool when performing lung transplantation and it has the potential to replace CPB.

Short-term Mechanical Circulatory Support with Centrifugal Pump in Cardiac Arrest or Cardiogenic Shock - Report of 5 cases- (심정지 혹은 심인성 쇼크에서 원심성 펌프를 이용한 단기목표의 기계적 순환 보조)

  • 양희철;성기익;뱍계현;전태국;박표원;양지혁;이영탁
    • Journal of Chest Surgery
    • /
    • v.37 no.12
    • /
    • pp.1003-1009
    • /
    • 2004
  • Mechanical circulatory support (MCS) has been used for myocardium failure, but moreover, it may be essential for the life support in cardiac arrest or cardiogenic shock. Many commercial devices can be used effectively for the long-term support. However, there are some limitations in the aspects of the cost and technical support by production company. Short-term support with centrifugal type has been reported numerously with the purpose of bridging to heart transplantation or recovery. We successfully treated 5 patitents who were in the status of cardiogenic shock (n=3) or arrest (n=2) with the technique of extracorporeal life support system (ECLS) or left ventricular assist device (LVAD) using the centrifugal type pump. The MCS were performed emergently (n=2) under cardiac arrest caused by ischemic heart disease, and urgently (n=3) under cardiogenic shock with ischemic heart disease (n=1) or acute fulminant viral myocarditis (n=2). All patients were weaned from MCS. Complications related to the use of MCS were bleeding and acute renal failure, but there were no major complications related to femoral cannulations. Mechanical circulatory support may be essential for the life support and rescue in cardiac arrest or cardiogenic shock.

Blood Flow and Pressure Evaluation for a Pulsatile Conduit-Shaped Ventricular Assist Device with Structural Characteristic of Conduit Shape (관형의 구조적 특징을 갖춘 박동형 관형 심실보조장치의 혈류, 혈압 평가)

  • Kang, Seong-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1191-1198
    • /
    • 2011
  • The use of a ventricular assist device (VAD) can raise the one-year survival rate without cardiac transplantation from 25% to 52%. However, malfunction of the VAD system causes 6% of VAD patients' deaths, which could possibly be avoided through the development of new VADs in which VAD malfunctions do not affect the patient's heart movement or hemodynamic state. A conventional VAD has an impeller or vane for propelling blood that can allow blood to regurgitate when the propelling force is weaker than the aortic pressure. In this paper, we developed a new pulsatile conduit-shaped VAD that has two valves. This device removes the possibility of blood regurgitation and has a small stationary area even when the pumping force is extremely weak. We estimated the characteristics of the device by measuring the outflow and the pressure of the pump in in-vitro and in-vivo experiments.