• Title/Summary/Keyword: 체결압력

Search Result 58, Processing Time 0.122 seconds

The Stress Distribution Analysis of PEMFC GDL using FEM (유한요소법을 이용한 고분자전해질연료전지 기체확산층의 응력분포 연구)

  • Kim, Chulhyun;Sohn, Youngjun;Park, Gugon;Kim, Minjin;Lee, Jonguk;Kim, Changsoo;Choi, Yusong;Cho, Sungbaek
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.5
    • /
    • pp.468-475
    • /
    • 2012
  • A proper stacking force and assembly are important to the performance of fuel cell. Improper assembly pressure may lead to leakage of fuels and high interfacial contact resistance, excessive assembly pressure may result in damage to the gas diffusion layer and other components. The pressure distribution of gas diffusion layer is important to make interfacial contact resistance less for stack performance. To analyze the influence of design parameter factors for pressure distribution, and to optimize stack design, DOE (Design of Experiment) was used for polymer electrolyte membrane fuel cell stack pressure test. As commonly known, the higher clamping force improves the fuel cell stack performance. However, non-uniformity of stress distribution is also increased. It shows that optimization between clamping force and stress distribution is needed for well designed structure of fuel cell stack. In this study, stack design optimization method is suggested by using FEM (Finite Element Methode) and DOE for light-weighted fuel cell stack.

Effect of Temperature on Interlaminar Fracture Toughness of Filament-Wound Carbon/Epoxy Composites (필라멘트 와인딩된 카본/에폭시 복합재의 층간파괴인성에 미치는 온도 영향)

  • Im, JaeMoon;Shin, KwangBok;Hwang, Taekyung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.39 no.5
    • /
    • pp.491-497
    • /
    • 2015
  • This paper reports an experimental study for evaluating the effect of temperature on the mode I, mode II and mixed-mode interlaminar fracture toughness of adhesive joints with a curved cross-section of filament-wound dome-separated composite pressure vessel. Mode I and mixed-mode interlaminar fracture toughness were evaluated using DCB specimens, while mode II interlaminar fracture toughness was determined using ENF specimens. $[{\pm}10^{\circ}]_6$, $[{\pm}27^{\circ}]_6$ and ($[{\pm}10^{\circ}]_3/FM73/[{\pm}27^{\circ}]_3$) winding specimens with the curved cross-section were considered. In-situ temperature environments were simulated with a range of $-30^{\circ}C-60^{\circ}C$ using an environmental chamber and furnace. Experimental results on the effect of temperature indicate that interlaminar fracture toughness tends to be high at low temperature and is degraded with increase in temperature. For specimen types, it was found that interlaminar fracture toughness of $[{\pm}10^{\circ}]_3/FM73/[{\pm}27^{\circ}]_3$ winding specimens considered as adhesive joints of dome and helical part was higher than other specimens.

Flow Safety Assessment by CFD Analysis in One-Touch Insertion Type Pipe Joint for Refrigerant (CFD 해석을 이용한 냉매용 원터치 삽입식 파이프 조인트의 유동 안전성 평가)

  • Kim, Eun-young;Park, Dong-sam
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.550-559
    • /
    • 2022
  • Purpose: Pipes are widely used as applied devices in many industrial fields such as machinery, electronics, electricity, and plants, and are also widely used in safety-related fields such as firefighting and chemistry. With the diversification of products, the importance of technology in the piping field is also increasing. In particular, when changing the existing copper pipe to stainless steel, it is necessary to evaluate safety and flow characteristics through structural analysis or flow analysis. Method: This study investigated the safety by flow analysis of the 6.35 inch socket model, which are integrated insert type connectors developed by a company, using CFD analysis technique. For CDF analysis, RAN model and LES model are used. Result: As results of the analysis, amplitude of the pressure fluctuation acting on the wall of the piping system is formed at a level of 3,780 Pa or less, which is a very small level of pressure compared with the operating pressure or design stress of the refrigerant piping. Conclusion: These results mean that the effect of vibration caused by turbulence on the structural safety of the pipe is negligible.

Effect of surface treatment on thermo-compression bonding properties of electrodes between printed circuit boards (표면처리에 따른 인쇄회로기판의 열압착 접합 특성 평가)

  • Lee, Jong-Gun;Lee, Jong-Bum;Choi, Jung-Hyun;Jung, Seong-Boo
    • Proceedings of the KWS Conference
    • /
    • 2010.05a
    • /
    • pp.81-81
    • /
    • 2010
  • 전자 패키징은 미세화, 경량화, 저가화를 지향하고 신뢰성의 향상을 위해 발전해 왔다. 이러한 경향은 전자부품 자체의 성능 향상 뿐 아니라 전자부품을 장착, 고정할 수 있게 하는 인쇄회로 기판(PCB : Printed Circuit Board)의 성능에 많은 관심을 가지게 되었다. 전기적 신호의 손실을 줄이기 위해 전기, 전자 산업체에서는 가볍고 굴곡성이 우수한 연성인쇄회로기판(FPCB : Flexible PCB)과 가격이 싸고 신뢰성이 입증된 경성인쇄회로기판(RPCB : Rigid PCB)이 그 대상이다. 본 논문에서는 이 PCB중에서도 RPCB와 FPCB간의 열압착 방식으로 접합 시 전극간의 접합 양상을 보았다. 이 열압착 방식은 기존에 PCB를 접합하는데 사용하고 있는 connector를 이용한 체결법을 대체하는 기술로써 솔더를 중간층(interlayer)로 이용하여 열과 압력으로 접합하는 방식이다. 이 방식을 connector를 사용하는 방식에 비해 그 부피가 작고 I/O개수에 크게 영향 받지 않으며 자동화 공정이 쉬운 장점을 가지고 있다. 접합의 대상 중 RPCB의 경우는 무전해 니켈 금도금(ENIG : Electroless Nickle Immersion Gold)로 제작하였으며 FPCB의 경우는 ENIG와 유기보호피막(OSP : Organic solderability preservation) 처리하였다. 실험에 사용한 PCB는 $300\;{\mu}m$ pitch의 미세피치이며 솔더의 조성은 Sn-3.0Ag-0.5Cu (in wt%)과 Sn-3.0Ag (in wt%)를 사용하였다. 접합 온도와 접합 시간 그리고 접합 압력에 따라 최적의 접합 조건을 도출하였다. 접합 강도는 $90^{\circ}$ Peel Test를 통해서 측정하였으며 접합면 및 파괴면은 SEM과 EDS를 통하여 분석하였다.

  • PDF

Comparisons of Empirical Braking Models for Freight Trains Using P4a Distribution Valve (P4a 분배밸브를 사용하는 화물열차의 경험적 제동모델들의 비교)

  • Choi, Don Bum;Kim, Min-Soo;Lee, Kangmi;Kim, Young-Guk
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.1
    • /
    • pp.61-69
    • /
    • 2020
  • This study examined the braking characteristics of a heavy haul freight train with P4a distribution valves applied to domestic high-speed freight trains. A freight train was composed of 50 cars, which is twice the normal operation. A braking test was performed to confirm the characteristics of the braking of a heavy haul. The brake cylinder pressures were measured for emergency and service braking on the 1st, 10th, 20th, 30th, and 50th cars. Because the brake signal is transmitted to the pressure through the braking tube connected to the end of the train, the rear vehicle is braking later than the vehicle ahead. Therefore, it is necessary to predict the brake pressures in all cars in a train to supplement the results of the limited tests and calculate the braking distance. The pressure in each car was determined using empirical models of linear interpolation, stepwise, and exponential models, which provided reliable information. The predictive results of the empirical models were compared with the measured results, and the exponential model was predicted relatively accurately. These results are expected to contribute to the safe operation of heavy haul freight trains and can be used to predict the braking distance and calculate the level of impact between vehicles during braking.

KSR-III 복합재 가압탱크의 설계 및 제작

  • Kong, Cheol-Won;Yoon, Chong-Hoon;Jang, Young-Soon;Yi, Yeong-Moo
    • Aerospace Engineering and Technology
    • /
    • v.2 no.2
    • /
    • pp.124-132
    • /
    • 2003
  • This paper described the structural design and the fabrication procedure of KSR-III composite pressure tank. The type of the composite pressure tank was COPV(Composite Overwrapped Pressure Vessel). A non-load sharing liner was made of aluminum 6061-0 and the liner provided a helium gas seal. The composite pressure tank was winded using T700 carbon/epoxy on the liner. Because the aluminum liner was thin, multiple cure cycles were applied to the filament winding technique. The multiple cure cycles prevented the liner-cylinder from losing a circular shape. A fitting force at the metallic boss was spread to the carbon fiber by a boss ring. The boss ring also prevented a local deformation at the boss part.

  • PDF

The Quasi 3-D Flow Simulation in injection Molding Using Virtual Pressure Reflection (가상 반사압력을 이용한 사출성형의 준3차원 유동해석)

  • 이호상;신효철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.7
    • /
    • pp.1294-1306
    • /
    • 1992
  • In order to determine the design parameters and processing conditions in injection molding, it is very important to establish the theoretical model with scientific base. In this study, a two dimensional model has been developed for the purpose and flow simulations of filling process are carried out. The moving boundary transient flow problem along the flat plane is solved efficiently by the Iterative Boundary Pressure Reflection Method which rearranges the impinged melt front along the physical boundary in scientific manner. The two dimensional modeling of filling process is applied to two examples : a three dimensional cover with two screw holes and a two-gated flat cavity with unbalanced runners. The numerical results show good agreement with experimental short shots, especially for the weldline locations and the pressure traces at various locations. They also provide the temperature, clamp force, and velocity field in the mold at different times during filling of cavity.

Assembly Analysis for Evaluation of Sealing in PEMFC Stack (고분자 전해질 연료전지 스택의 시일링 평가를 위한 체결 해석)

  • Kim, Dae-Young;Kim, Jung-Min;Kim, Heon-Young
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.18 no.5
    • /
    • pp.68-75
    • /
    • 2010
  • The one of the major problems in the development of PEMFC was regarding to the assurance of sealing on stack. The failure on the sealing creates the problems of fuel leakage, mixing, internal combustion, damage on parts and can be a direct reason for the degrading the efficiency of fuel cell. This paper studies on the analytical approach for improving the contacting pressure distribution on the gasket at the evaluation on the sealing of fuel cell stack. So, the assembly analysis on multi layered fuel cell stack was performed. The research on the simplification of finite element model was performed for three dimensional analysis at the multi layered state. The improved contact pressure distribution was obtained through the case studies on gasket for better sealing. In addition, the number of the cell was determined for the effective analysis and the structural characteristics were evaluated based on this research.

An Evaluation of the Structural Stability of a Clip Type Prefabricated Greenhouse under Strong Wind and Heavy Snow Conditions (조립식 클립형 비닐하우스의 강풍 및 폭설시 구조 안정성 평가)

  • Ro, Kyoung-Chul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3423-3428
    • /
    • 2014
  • Numerical studies were performed to evaluate the structural safety of a greenhouse under both snow and wind loads. In the case of a wind load, fluid-structure interaction (FSI) method was used to consider the local pressure distributions on the greenhouse-induced by aerodynamic characteristics. The results showed that the maximum stress and deformation occur near the junction of pipe supports and rafters of the roof, where connecting clips are installed. Moreover, the wind load is a more severe condition than a snow load. Overall, these results will be used to design a prefabricated connecting clip with easy installation and low maintenance.

The Effect of Impact Absorbing System with 2 DOF Deformation According to the Variation of Cylinder Wall on Damping Coefficient (실린더 벽면 변화가 2자유도계 충격흡수장치의 감쇠계수에 미치는 영향)

  • Han, Geun-Jo;Ahn, Chan-Woo;Ahn, Sung-Chan;Shim, Jae-Joon;Kim, Sung-Youn
    • Journal of Navigation and Port Research
    • /
    • v.26 no.1
    • /
    • pp.101-105
    • /
    • 2002
  • Many malfunction take place in container crane spreader due to impact. So we designed a 2 DOF hydraulic impact absorbing equipment to absorb the impact and we studied the change of damping coefficient with respect to the variation of dimensions of oil-Cylinder wail. When we design the dimension of hydraulic cylinder wall considering the displacement on the wall, the value of it over 20m didn't affect the damping coefficient.