• Title/Summary/Keyword: 청각 자극

Search Result 250, Processing Time 0.025 seconds

Study on Vehicle Haptic-Seat for the Driving Information Transfer to Driver for the Elderly (고령운전자 운전정보전달을 위한 차량용 햅틱시트 연구)

  • Oh, S.Y.;Kim, K.T.;Yu, C.H.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.3
    • /
    • pp.151-160
    • /
    • 2014
  • In this study, the effect of the automotive haptic-seat technology which can transmit the driving information by the vibro-stimulus from the seat was investigated to overcome previous system's limitation relied on the visual and audial method and to help handicap driving. A prototype haptic seat cover with 30 coin-type motors and driver module were developed for this sake. In an experiment of seat vibration stimulation being performed under virtual driving situation by targeting the elderly aged over 65 years old, average score of test subjects for total vibration recognition was 3.5/4 points and recognition rate of 87.5% was represented. In addition, a result that all the test subjects totally recognized overspeed warning signal of 4 times was represented. As a result of statistical analysis for vibration recognition score by each group depending on TMT score, a significant difference was not found and a result that tactile function of which vibration is recognized even by the aged whose visual, perceptional function is declined showed an equal ability was obtained.. In this study it was shown that the seat vibration stimulus could be used to transfer the old drivers' information while driving.

  • PDF

Fabrication of EEG Measuring System with High Precision Characteristics (고정밀도의 뇌파측정시스템 개발 연구)

  • 도영수;장호경;한병국
    • Progress in Medical Physics
    • /
    • v.13 no.3
    • /
    • pp.156-162
    • /
    • 2002
  • In this study, we attempted in preparing high precision EEG measuring equipment. To measure EEG in high efficiency, pre-amplifier should get high performance common mode rejection ratio. Also, separation amplifier is essential to eliminate common line noise. So, our study were pointed at elevating the efficiency of eliminating noise, user safety and low noise characteristics. Prepared high precision pre-amplifier for EEG was A/D converted to automatically classify $\alpha$ wave, $\beta$ wave and $\theta$ wave. And converted data were Fast Fourier Transformed with real time DSP (Digital Signal Processing). Clinical demonstrations were carried out with healthy students, aged between 20 to 26 who has no histories of illness. To recognize the efficiency of the EEG, prepared EEG were used with MS equipment in low stimulated state and high stimulated state. Then, we studied at the effect of sensitivity on brain wave. From this study, it is known that our EEG equipment is efficient in sensitivity evaluation and suitable stimulations for each psychological state are required.

  • PDF

Development of a Finger Tactile Stimulator Based on E-Prime Software (E-Prime에 기반한 손가락 촉각 자극기의 개발)

  • Kim, Hyung-Sik;Min, Yoon-Ki;Kim, Bo-Seong;Min, Byung-Chan;Yang, Jae-Woong;Lee, Su-Jeong;Choi, Mi-Hyun;Yi, Jeong-Han;Tack, Gye-Rae;Lee, Bong-Soo;Jun, Jae-Hoon;Chung, Soon-Cheol
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.703-710
    • /
    • 2010
  • In this study, a tactile stimulator was developed to resolve some problems from the previous version of the system such as system configuration, inappropriate stimulation control and additional problems. The developed tactile stimulator consists of control unit, drive unit and vibrator unit. The control unit was controlled by E-Prime software to generate appropriate vibration pulses. The drive unit supplies enough energy to the vibrator to generate effective stimulation pulses. The vibrator unit consists of small coin type vibrator and velcro, and was made to be attached at the hand easily. The developed tactile stimulator was designed by small-size, light-weight, low-power, simple-fabrication, max 35 channels and little delay time from instruction signal of E-Prime software to vibrator. The duration and magnitude of stimulation was controlled by 10 grades and the problems concerning stimulation control were compensated by wideband frequency ranges. Additionally, the electrical safety was ensured by low voltage operation. Vibrator was made to be attached on finger as well as on any part of the subject. Since this tactile stimulator is developed based on E-Prime software which is widely used in cognitive science, it is believed that this stimulator be suitable for the wide application of cognitive science study.

  • PDF

Neural responses to sonic branding : an fMRI study (소닉 브랜딩에 대한 신경 반응 : fMRI 연구)

  • Sung, Young-Shin;Choi, Min-Jo;Chung, Sun-Joo;Kim, Chai-Youn
    • Science of Emotion and Sensibility
    • /
    • v.14 no.1
    • /
    • pp.93-100
    • /
    • 2011
  • Sonic branding is defined as creation and management of brand value by using sounds. Among various methods of sonic branding, sonic logo, i.e., brand’s acoustic identification element, is the most widely used form and usually combined with visual logo. Although sonic branding has become an increasingly important tool for marketers, little academic research has been done on this topic. The current study investigates neural responses to sonic branding using functional Magnetic Resonance Imaging (fMRI). Brain activity of 15 right-handed participants was monitored with 3T MRI machine, while they viewed sequentially presented pictures of brand logos (20 visual logos usually accompanied by sonic logos and 20 visual logos unaccompanied by sonic logos) without sound. Results showed that brain areas known to be associated with auditory imagery (including superior temporal gyrus, STG), showed greater activation for the visual logos usually accompanied by sonic logos compared to visual logos unaccompanied by sonic logos, although actual sound was not presented during scanning. The degree of familiarity participants have with the brand and its advertisements was correlated positively with signal strength in these areas.

  • PDF

Relationship between Smartphone Addiction and Sensory Processing Ability of Preschool Children (학령전기 아동의 스마트폰 중독과 감각처리능력과의 관계)

  • Kim, Chae-Hyeon;Kim, Kyeong-Mi;Chang, Moon-Young;Jung, Hyerim
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.19 no.2
    • /
    • pp.1-11
    • /
    • 2021
  • Objective : The purpose of this study was to compare sensory processing ability by smartphone addiction levels in preschool children, and to investigate the correlation between smartphone addiction level and sensory processing ability within smartphone addiction group. Method : The subjects of this study were 324 persons, with 124 persons in the addiction group and 200 in the normal user group. Measurements in this study were a questionnaire about general characteristics of subject, smartphone addiction scale, and short sensory profile. Methods for the data analysis included descriptive statistics, independent t-test, Pearson correlation analysis of SPSS 22.0. Results : There was a significant difference in the total Short Sensory Profile (SSP) score and in all sub-domains between the addiction and normal use groups (p<0.05). In the smartphone addiction group, there was a negative correlation between the SSP total score (r=-.278), auditory filtering (r=-.293), visual/auditory sensitivity (r=-.393) and smartphone addiction level. Conclusion : This study confirmed that there was a difference in smartphone addiction and sensory processing ability between the preschool children addiction and normal use groups. It has been proven that there is an interrelationship between sensory processing ability and smartphone addiction in the addiction group. It is significant in that it provides basic data to prevent smartphone addiction.

Pin-Type Vibrotactile Display (핀형 진동촉각 출력장치)

  • Back, Jong-Won;Choi, Dai-Sung;Jang, Tae-Jeong
    • 한국HCI학회:학술대회논문집
    • /
    • 2006.02a
    • /
    • pp.463-466
    • /
    • 2006
  • 최근 전자기기에서 시각 및 청각과 함께 촉각 디스플레이가 정보를 출력하는 중요한 수단으로 부각되고 있다. 본 논문에서는 촉각 정보 출력을 위한 소형진동촉각(vibrotactile) 디스플레이 모듈을 개발하였다. 개발한 모듈은 주파수와 진폭을 독립적으로 조절할 수 있으며 핀이 직접 피부에 자극을 주기 때문에 몸체 전체가 떨리는 기존의 진동모터보다 정밀하고 다양한 촉각 표현을 할 수 있다. 또한 고전압을 이용하는 Piezo 방식과 달리 낮은 전력으로 동작이 가능하여 휴대장치에 직접 장착할 수 있는 장점을 가지고 있다.

  • PDF

PHYSIOLOGICAL INDICATORS OF EMOTION AND ATTENTION PROCESSES DURING AFFECTIVE AND ORIENTING AUDITORY STIULATION (청각자극에 의해 유발된 정서 및 주의반응의 생리적 지표)

  • Estate M. Sokhadze
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • 1998.06c
    • /
    • pp.291-296
    • /
    • 1998
  • In the experiment carried out on 20 college students, recorded were frontal, temporal and occipital EEG, skin conductance response, skin conductance level, heart rate and respiration rate during listening to two music fragments with different affective valences and white noise administered immediately after negative visual stimulation. Analysis of physiological patterns observed during the experiment suggests that affective auditory stimulation with music is able to selectively modulate autonomic and cortical activity evoked by preceding aversive visual stimulation and to restore initial baseline levels. On other hand, physiological responses to white noise, which does not possess emotion-eliciting capabilities, evokes response typical for orienting reaction after the onset of a stimulus and is rapidly followed by habituation. Observed responses to white noise were similar to those specific to attention only and had no evidence for any emotion-related processes. Interpretation of the obtained data is considered in terms of the role of emotional and orienting significance of stimuli, dependence of effects on the background physiological activation level and time courses of attention and emotion processes. Physiological parameters are summarized with regard to their potential utility in differentiation of psychological processes induced by auditory stimuli.

  • PDF

Improvement of Sound Quality using Compensation of Perceptual Filter Response (지각 필터 응답 보상을 통한 음질 개선)

  • Chae Byoung-Koog;Cha Hyuk-Geun;Cha Hyung-Tai
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.295-298
    • /
    • 2004
  • 본 논문에서는 잡음에 오염된 신호의 지각관계를 해석하여 지각 필터 응답 제어를 통한 음성 신호 개선 알고리즘을 제안한다. 음성 신호 개선 기법은 단일 채널환경에서 사람의 청각시스템에서의 주파수 변별력을 나타내는 각각의 임계대역에 대한 전체 에너지를 나타내는 임계대역 에너지의 지각적인 확산의 영향 즉, 마스킹 확산의 영향을 나타내는 자극에너지를 이용하여 신호와 잡음 에너지에 의해 변화하는 잡음에 의한 신호의 마스킹 구간을 검출하여 묵음 구간 추출 잡음 필터응답과 추정 잡음 오차를 보상시킨 필터응답을 통한 지각 필터 응답을 보상하여 신호를 개선하는 방법이다. 실험 결과 제안한 방법을 통해 SNR에 개선과 음질 개선 효과를 얻을 수 있음을 테스트를 통해 확인하였다.

  • PDF

Audio Quality Enhancement using Perceptual Property at a Low-bitrate Compression (지각적 특성을 이용한 저 비트오율 압축 오디오 음질개선)

  • Cha Hyuk-Geun;Chae Byoung-Koog;Cha Hyung-Tai
    • Proceedings of the Acoustical Society of Korea Conference
    • /
    • autumn
    • /
    • pp.275-278
    • /
    • 2004
  • 본 논문에서는 저 비트오율 압축 시 발생되는 신호 왜곡을 인간의 지각적 특성을 이용하여 음질을 개선하는 알고리즘을 제안한다. 저 비트오율 압축 과정에서 손실된 고주파 영역의 신호를 부가 정보를 사용하지 않고 손실되지 않은 영역의 정보를 사용하여 고주파 영역의 신호를 첨가함으로써 음질을 개선하였다. 비 손실 영역의 순음 및 비 순음 성분을 검출하여 손실영역에 해당 하모닉 성분을 청각 자극 에너지로 스케일 하여 새로운 신호를 첨가한다. 원 신호와 저 비트오율 압축으로 인해 왜곡된 신호, 그리고 본 논문의 알고리즘을 이용하여 개선된 신호를 신호 대 잡음 비를 측정하고 청감 테스트를 통해 음질 개선 효과를 확인하였다.

  • PDF

The Effects of the Auditory Stimulus on Postural Control (자세제어에 대한 청각자극의 효과)

  • Kim, Y.;Jung, J.S.;Kim, N.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1997 no.05
    • /
    • pp.418-421
    • /
    • 1997
  • We examined the effect of the auditory stimulus on postural control. The auditory stimulus control system composed of 8 speakers ,the audio amplifier, the PPI interface and the sound controller. We measured the sway of head position and COP. Our result showed that the auditory stimulus was effective on postural control. It also indicated that the auditory stimulus system might be applied to clinical use as a new postural control training system.

  • PDF