• Title/Summary/Keyword: 천공수

Search Result 435, Processing Time 0.028 seconds

Investigation of Fracture Propagation in Cement by Hydraulic Fracturing Under the Tri-axial Stress Condition (시멘트 시료에 대한 삼축압축 환경에서의 수압파쇄시험 연구)

  • Riu, Hee-Sung;Jang, Hyun-Sic;Jang, Bo-An
    • The Journal of Engineering Geology
    • /
    • v.27 no.3
    • /
    • pp.233-244
    • /
    • 2017
  • We conducted hydraulic fracturing experiments on cement samples to investigate the dependency of fracture propagation on the viscosity of injection fluid and the in situ stress state. Ten cubic samples (20 cm side length) were produced using cement that was cured in water for more than one month. Samples were placed in a tri-axial compression apparatus with three independent principal stresses. An injection hole was drilled and the sample was hydraulically fractured under a constant injection rate. We measured injection pressures and acoustic emissions (AE) during the experiments, and investigated the fracture patterns produced by hydraulic fracturing. Breakdown pressures increased exponentially with increasing viscosity of the injection fluid. Fracture patterns were dependent on differential stress (i.e., the difference between the major and minor principal stresses). At low differential stress, multiple fractures oriented sub-parallel to the major principal stress axis propagated from the injection hole, and in some samples the fracture orientation changed during propagation. However, at high differential stress, a single fracture propagated parallel to the major principal stress axis. AE results show similar patterns. At low differential stress, AE source locations were more widespread than at high differential stress, consistent with the fracture pattern results. Our study suggests that hydraulic fracturing during shale gas extraction should be performed parallel to the orientation of minimum differential stress.

Developing an improved water discharge anchor & trap bolt to prevent basic salt penetration to harbor structures (해수 염기 침투방지를 위한 성능개선 형 물배출 앵커 및 트랩볼트 개발에 관한 연구)

  • Ock, Jong-Ho;Moon, Sang-Deok;Lee, Hwa-Sun;Shin, Kyung-Soo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.4
    • /
    • pp.674-682
    • /
    • 2018
  • Large industrial motors require a large area because of the high risk of shutdown accidents and large industrial accidents due to the lowering of the dielectric strength of the armature windings and overheating problems. Therefore, there is a demand for a large-capacity motor that has small size, light weight, and excellent dielectric strength compared with conventional motors. Superconducting motors have advantages of high efficiency and output power, low size, low weight, and improved stability. This results from greatly increasing the magnetic field generation by using superconductive field coils in rotating machines such as generators and motors. It is very important to design and analyze the cooling system to lower the critical temperature of the wires to achieve superconducting performance. In this study, a field loss analysis and low-temperature heat transfer analysis of the cooling system were performed through the conceptual design of a 100-HP high-temperature superconducting synchronous motor. The field loss analysis shows that a uniform pore magnetic flux density appears when high-temperature superconducting wire is used. The low-temperature heat transfer analysis for gaseous neon and liquid neon showed that a flow rate of 1 kg/min of liquid neon is suitable for maintaining low-temperature stability of the high-temperature superconducting wire.

Development of Steel Pipe Attached PHC Piles for Increasing Base Load Capacity of Bored Pre-cast Piles (매입말뚝의 선단지지력 증대를 위한 강관 부착 PHC파일 개발)

  • Paik, Kyu-Ho;Yang, Hee-Jeong
    • Journal of the Korean Geotechnical Society
    • /
    • v.29 no.8
    • /
    • pp.53-63
    • /
    • 2013
  • Bored pre-cast piles using PHC piles is widely used in foundation of building structures constructed in urban areas because noise and vibration due to pile installation are low. However, since slime is formed at the base of borehole and the density of bearing stratum surrounding the base of borehole is decreased due to stress relaxation in drilling process of bored pre-cast pile method, the base load capacity of bored pre-cast piles is very low compared to the strength of bearing stratum. In this study, a new type of PHC pile, which short steel pipe with the same diameter as the PHC pile is attached to the pile tip, is developed to increase the base load capacity of bored pre-cast piles. In order to check the effect of the use of new PHC pile on the base load capacity of bored pre-cast piles, field pile load tests are performed for bored pre-cast piles using the new and existing PHC piles. Results of the pile load tests show that the new PHC pile gives higher base load capacity to bored pre-cast piles than the existing PHC pile, since the tip of new PHC pile is penetrated to undisturbed bearing stratum passing through the slime at the base of borehole and the loosened bearing stratum under the slime by pile driving using light hammer.

A Case of Extensive Stage Small Cell Lung Cancer Presenting as an Acute Appendicitis with Perforation (전이성 병소에 의해 발생한 급성 충수염의 천공으로 진단된 전신병기 소세포폐암 1예)

  • Shin, Dong Won;Choi, Moon Han;Park, Seung Sik;Park, Sung Woo;Kim, Ki Up;Jang, An Soo;Park, Choon-Sik;Lim, Cheol Wan;Ko, Eun Suk;Paik, Sang Hyun;Kim, Do Jin
    • Tuberculosis and Respiratory Diseases
    • /
    • v.65 no.3
    • /
    • pp.230-234
    • /
    • 2008
  • The incidence of appendiceal metastatic cancer is quite low. In particular, in small cell lung cancer, there is a very low incidence of a metastasis to the appendix. A 75-years old man with right lower quadrant pain, cough and sputum was transferred to our hospital. Abdominal CT revealed acute appendicitis with a perforation. The patient underwent surgery. The frozen sections of the tissue obtained during surgery, indicated a malignancy, but a right hemicolectomy was not performed due to the patient's poor general condition. The histology findings of the appendix were identified as a small cell carcinoma. The abdominal CT scan and chest x-ray at admission day showed a mass in the right lower lobe, and a further evaluation of the lesion was performed including positron emission tomography and flexible bronchoscopy with a biopsy. The pathology findings of the lung mass were also small cell lung cancer. The specimens from both sites stained positive for cytokeratin, cluster designation 56, synaptophysin, chromogranin-A and thyroid transcription factor 1. It was concluded that the appendiceal small cell cancer originated from the lung.

A Review of Host Plants of Cerambycidae (Coleoptera: Chrysomeloidea) with new Host Records for Fourteen Cerambycids, Including the Asian Longhorn Beetle (Anoplophora glabripennis Motschulsky), in Korea (유리알락하늘소를 포함한 14종 하늘소의 새로운 기주식물 보고 및 한국산 하늘소과(딱정벌레목: 잎벌레상과)의 기주식물 재검토)

  • Lim, Jongok;Jung, Su-Young;Lim, Jong-Su;Jang, Jin;Kim, Kyung-Mi;Lee, You-Mi;Lee, Bong-Woo
    • Korean journal of applied entomology
    • /
    • v.53 no.2
    • /
    • pp.111-133
    • /
    • 2014
  • A revised checklist of host plants for 181 species belonging to 103 genera in six subfamilies of Cerambycidae (Coleoptera: Chrysomeloidea) in Korea is provided on the basis of the results of field surveys and literature review. A total of 14 new cerambycid-host associations are confirmed and the Manchurian striped maple, Acer tegmentosum Maxim. (Aceraceae), is listed as a new host of the Asian longhorn beetle, Anoplophora glabripennis (Motschulsky). The names of more than 170 host plants species belonging to 107 genera in 44 families are compiled. Among them, four families (Ulmaceae, Pinaceae, Fagaceae and Betulaceae) are confirmed as the main host families (more than 23%) of most of the cerambycid species. All invalid scientific names and Korean names of plants and cerambycids in the previous literature are corrected in the present paper.

Application of Master Packaging System to Fresh Shiitake Mushroom Supply Chain on Semi-commercial Scale (생표고버섯에 대한 마스터 포장 시스템의 현장 적용)

  • An, Duck Soon;Lee, Ji Hye;Lee, Hye Lim;Lee, Dong Sun
    • KOREAN JOURNAL OF PACKAGING SCIENCE & TECHNOLOGY
    • /
    • v.20 no.3
    • /
    • pp.71-76
    • /
    • 2014
  • Master packaging system is a technology combining primary and secondary packaging to preserve the fresh produce in the supply chain. Master packaging system with tailor-designed gas transfer and $CO_2$ absorber of $Ca(OH)_2$ was applied to fresh shiitake mushroom in its supply from farm to retail store. The temperature, humidity and package atmosphere were monitored through the distribution and/or storage until the packages were opened to measure the mushroom quality. Conventional perforated individual packages without secondary master pack were prepared and travelled the same path for comparison purpose. While high temperature history was observed in some initial period of actual practice of the mushroom transportation and storage unexpectedly, the package atmosphere around the produce in the master packaging system was maintained at modified atmosphere consisting of $O_2$ concentration of 0.4 to 4.2% and $CO_2$ concentration of 0.7 to 1.7%, which is known to be beneficial for the mushroom preservation. While curing the mushrooms with precooled drying was effective for quality preservation, positive effect of master packaging system could be apparent for the uncured mushroom. Harmonized combination of curing treatment, master packaging system and temperature management was suggested for the best quality preservation of the fresh shiitake mushroom.

  • PDF

Postnatal Management of Antenatally Diagnosed Patent Urachus with Bladder Prolapse

  • Choi, Hyun-Shin;Kim, Hae-Eun;Kim, Eun-Sun;Oh, Soo-Young;Chang, Yun-Sil;Seo, Jeong-Meen;Park, Won-Soon
    • Neonatal Medicine
    • /
    • v.17 no.2
    • /
    • pp.262-264
    • /
    • 2010
  • A case of bladder prolapse through a patent urachus is reported in a female infant born with a large, red, tubular mass inferior to the umbilical cord. A cystic mass communicating with fetal bladder was detected by prenatal ultrasound performed at $20^{+2}$ weeks of gestation. A fetal MRI was also performed to confirm the diagnosis and to exclude associated fetal anomalies. At $40^{+4}$ weeks, the cystic mass was no longer present and a new small solid mass was noted at the fetal abdominal wall. After birth, a protruded mucosal mass inferior to the umbilical cord was noted, and catheterization confirmed communication between the protruded mass and the urinary bladder. On the second day of life, reduction of the bladder and partial resection of the urachus was performed. A voiding cystourethrogram showed good bladder capacity and no vesicoureteral reflux. The patient voided well and was discharged after 10 days. Here, we present a case of urinary bladder prolapse through a patent urachus, diagnosed by fetal sonography and this is the first case reported that was treated by simple excision without complication.

Environmental Survey to a Ventilation System on the Enclosed Farrowing-nursery Pig House in Winter (무창 분만ㆍ자돈사내에서 환기시스템별 혹한기 환경 조사)

  • 유용희;송준익;정종원;김태일;최희철;양창범;이영윤
    • Journal of Animal Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.23-28
    • /
    • 2004
  • This study was conducted to improve a ventilation system on the enclosed farrowing-nursery pig house in Korean swine facilities. This survey ventilation system types four major structures. The first structure has planer slot inlet, where air comes in, and these are placed outside the wall under the eave. Then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V1). The second structure has an air input through the perforated ceiling inlet, then the air from the pig house flows out through the chimney outlet operated by an exhaust fan(V2). Through the circular duct inlet placed inside the juncture of the entry wall, air also comes in(third structure). Then, air from the pig house flows out through the chimney outlet operated by an exhaust fan(V3), Similarly, air comes in through the circular duct inlet placed inside the juncture of the entry wall, but air from the pig house flows out through the side wall by an exhaust fan(V4). Temperature, relative humidity, air velocity and ammonia concentration(NH$_3$) were measured in the interior farrowing-nursery pig house during winter. The results were as follows; Interior temperature at the pig house was not remarkably different in all ventilation systems. The V4 system had low area air velocity, and this was better than other systems. It also had a lower ammonia concentration than other systems. V3 and V4 systems had stable airflow patterns, better than other systems. Therefore, it is suggested that the V3 and V4 ventilation system be applied in the enclosed farrowing-nursery pig house in winter.

  • PDF

Agricultural Radial Collector Wells in South Korea and Sustainability (한국의 농업용 방사상 집수정 현황 및 지속가능성)

  • Hong, Soun-Ouk;Song, Sung-Ho;An, Jung-Gi;Kim, Jin-Sung
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.331-337
    • /
    • 2016
  • Radial collector wells (RCWs) have been managed by Korea Rural Community Corporation (KRC) since 1983, installing 98 wells for agriculture in rural area over the country. Among them, 20 wells were installed upstream of 5 subsurface dams and the remaining were installed regardless of the subsurface dam. Most of RCWs have been developed in 1980s and 1990s, and 83 wells have been passed more than 20 years after construction. The number of horizontal arms for RCWs varies from 9 to 28, with length and diameter being 10~30 m and 65 mm, respectively. The central caisson with an inner diameter of 3.5 m was commonly constructed to a depth of 10 m. The maximum pumping rates in RCWs, which are located at distances of 10 to 1,200 m from the river, are 2,000~10,000 m3/day. RCW has a fundamental problem that reduced pumping capacity and degraded well efficiency, due to the physical and chemical clogging. From the feasibility test for improving RCW performance, specific capacity increased to 67% after rehabilitation. TV logging for RCW horizontal arm shows that near the caisson is more severe clogging. From the results of this study, KRC has established the guidebook for monitoring and improving well efficiency through physical/chemical treatment, well logging, and hydraulic tests and managed RCWs periodically with its rehabilitation methods.

Long-Term Result of Tricuspid Valve Replacement (삼첨판막 치환술의 장기성적)

  • Lim, Cheong;Kang, Moon-Chul;Kim, Kyung-Hwan;Kim, Ki-Bong;Ahn, Hyuk
    • Journal of Chest Surgery
    • /
    • v.34 no.9
    • /
    • pp.680-685
    • /
    • 2001
  • Background: Tricuspid valve replacement is very rarely performed procedure and its long-term result is not yet satisfactory. Moreover, it is not well known whether bioprosthesis or mechanical prosthesis is the best selection for artificial valve. We reviewed 72 cases of tricuspid valve replacements in 71 patients between January 1989 and December 1998, trying to analyze the overall results and risk factors for mortality and morbidity. Material and Method: Average age of the patients at the time of operation was 42$\pm$13 years(range 16 to 65 years) and the sex ratio of male versus female was 32/39. Primary diagnosis consisted of 50 cases of aquired valvular heart disease and 18 cases of congenital heart disease, such as Ebstein’s anomaly. 4 cases had isolated tricuspid valve regurgitation. Implanted valves were 69 mechanical prosthesis and 3 bioprosthesis. Concomitant mitral or aortic valve replacements were performed in 50 cases. One patient received concomittant pulmonary valve replacement. Result: There were 7(9.72%) operative deaths and 7(13.0%) late deaths. Actuarial survival at 10 years was 59.2$\pm$7.2%. Prosthetic tricuspid valve thrombosis occurred 11 times in 5 patients. Reoperation for prosthetic tricuspid valve failure was performed in 1 patient. In this case, examination of the explanted prostheses showed that the tricuspid stenosis was the result of valve thrombosis. Among the 47 survivors, 46 patients(98%) were in functional class I or II. Conclusion: In our ten-year experience of tricuspid valve replacement, mortality and morbidity were satisfactory. Mechanical prosthesis in tricuspid position showed comparable clinical results as bioprosthesis.

  • PDF