• Title/Summary/Keyword: 처리조합

Search Result 1,846, Processing Time 0.045 seconds

$3^{n-p}$ Fractional Factorial Desig Excluded A Debarred Combination (실험불가능한 처리조합이 배제되는 $3^{n-p}$ 일부실시법)

  • 최병철;최승현
    • The Korean Journal of Applied Statistics
    • /
    • v.11 no.2
    • /
    • pp.303-315
    • /
    • 1998
  • In a factorial experiment, certain combinations of factor levels clay not be ruled out for operational or economical reason. A fractional factorial design that contains such infeasible combinations, called debarred combinations, becomes too unbalanced to estimate the required effects. This thesis presents a method of selecting defining contrasts for constructing regular $3^{n-p}$ fractional factorial design which does not contain a debarred combination. Consequently, the construction of the design is accomplished by choosing the defining contrasts so that one of defining contrasts is compatible with a debarred combination.

  • PDF

Effect of Mixed Pasture Using Domestic Varieties Orchardgrass 'Kodione' and Tall fescue 'Purumi' on Forage Yields and Botanical Composition in Middle Region of Korea (중부지역에서 국내육성 목초 오차드그라스 '코디원' 및 톨 페스큐 '푸르미' 이용 초지조성 혼파조합별 사초생산성 및 식생에 미치는 영향)

  • Hwang, Tae-Young;Ji, Hee Chung;Kim, Ki Yong;Lee, Sang-Hoon;Lee, Ki-Won;Choi, Gi Jun
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.36 no.2
    • /
    • pp.89-97
    • /
    • 2016
  • This study was carried out to determine the effect of mixed pasture using domestic varieties orchardgrass 'Kodione' and tall fescue 'Purumi' on forage yields and botanical composition from 2013 to 2015 in middle region of Korea. The following mixed pastures were used in this study: treatment A (orchardgrass oriented mixture with imported varieties), treatment B (orchardgrass oriented mixture), treatment C (orchardgrass and tall fescue oriented mixture), treatment D (tall fescue oriented mixture), treatment E (tall fescue oriented mixture without orchardgrass), treatment F (only orchardgrass), and treatment G (only tall fescue). In botanical compositions at last cutting time in 2015, treatment A had orchardgrass at 7.1%, tall fescue at 47.9%, kentucky bluegrass at 15.2% and white clover at 25%. Meanwhile, treatment B had orchardgrass at 25.9%, tall fescue at 47.0%, kentucky bluegrass at 4.9% and white clover at 18.3%. Consequentially, in botanical composition from 2014 to 2015, treatment A was changed more compare to other treatments B, C, D and E. The average of dry matter (DM) yield for 2 years of treatment E (18,369 kg/ha) was the highest among the seven treatments, but there was no significant difference among other treatments except treatment A (p>0.05). The crude protein (CP) and in vitro dry matter digestibility (IVDMD) of treatment A were 14.5% and 74.8%, and treatment E were 14.1% and 73.0%, respectively. The content of neutral detergent fiber (NDF) and acid detergent fiber (ADF) were lower in treatment E and A than other treatments, and treatment E showed high content of total digestible nutrient (TDN). Therefore, tall fescue oriented mixture using domestic tall fescue variety Purumi had good forage productivity, quality and botanical composition in middle region of Korea for the establishment of grassland.

Design of Seal Imprint Identification System for Personal Verification (본인확인을 위한 인감조합시스템의 설계)

  • 조기형;이대영
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.16 no.8
    • /
    • pp.793-800
    • /
    • 1991
  • In this paper, proposed the seal imprint verification system that could add on the redident information system. In the positioning process, used ring data and in the matching process, used XY pixel distribution. As a result of the verification experiment, the error verification ratio is about 1%. But could verify that this system could be added and operated on the resident information system through the eye-decision after subtacting and adding process.

  • PDF

고도산화방법 조합에 따른 염색폐수의 COD 및 색도 제거

  • 이상호;김선희;배준삼
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2004.05a
    • /
    • pp.320-323
    • /
    • 2004
  • 두가지 처리방법을 연계처리하여 실험한 결과 펜톤산화를 전처리로 적용하여 실험한 경우가 COD와 Color의 제거면에서 더 높은 처리효율을 보이고 있으며 본 연구의 실험 목적인 RFP상의 수질기준을 만족하였다. 배출수 수질 기준이 강화된 RFP상의 수질기준을 만족하기 위한 고도산화방법의 연계처리방법 중 오존산화와 펜톤산화를 조합한 결과 유기물과 색도를 고루 제거하는 펜톤산화를 전처리 공정으로 적용하고 유기물의 제거보다는 색도제거에 더 효율적인 오존처리 공정을 후처리로 둔 조합공정이 더 적합한 것으로 판단된다.

  • PDF

Hangul Porting and Display Method Comparison for an LN2440SBC System (LN2440SBC 시스템을 위한 한글 포팅 및 출력 방식 비교)

  • Kim, Byoung Kuk;Park, Geun Duk;Oh, Sam Kweon
    • Proceedings of the Korea Information Processing Society Conference
    • /
    • 2009.04a
    • /
    • pp.635-638
    • /
    • 2009
  • 컴퓨터 디스플레이를 위한 한글 표현 방법에는 한글 음절의 초성, 중성, 종성 각각에 코드를 부여하고, 이를 조합하여 1 음절을 2 바이트로 처리하는 표준 조합형 코드와 각 음절마다 2 바이트 코드를 부여하는 표준 완성형 코드, 그리고 모든 국가의 언어를 표현하기 위한 만국 공통의 문자부호 체계인 유니코드 방식이 있다. 일반적으로 임베디드 시스템은 PC에 비해 상대적으로 속도가 느리고 저장공간 또한 제한되어 있으나 그 용도에 따라 PC에 필적하는 성능을 가지는 경우도 있다. 따라서 화면에 한글을 출력할 경우, 임베디드 시스템의 자원 환경에 맞는 적합한 방식을 채택해야 한다. 본 논문은 시랩시스(CLabSys)사의 3.5" TFT LCD 키트인 LP35가 부착된 LN2440SBC 임베디드 보드(S3C2440A CPU, 400MHz)의 TFT LCD 드라이버 제작을 위한 초기화 방법과 픽셀 디스플레이 함수를 소개한다. 또한 픽셀 디스플레이 함수와 비트맵 폰트를 사용하여 표준 조합형, 표준 완성형, 유니코드 방식의 3가지 방식에 대한 한글 출력 처리 속도와 필요 메모리 용량을 비교한다. 시험 결과에 따르면, 표준 조합형은 적은 메모리 공간을 차지하지만 초성, 중성, 종성을 조합하는데 시간이 소요되고, 완성형은 조합형에 비해 출력 처리 속도는 빠르나 모든 음절의 저장을 위해 비트맵 폰트의 용량이 크며, 유니코드는 비트맵 폰트의 용량은 가장 크지만, 국가 간 언어의 호환성을 보장하고 출력 속도 또한 세 가지 방식 중 가장 빠른 것으로 나타났다.

Optimum Configuration Method and Livestock Wastewater Loding for Treating Livestock Wastewater in Constructed Wetlands by Natural Purification Method (자연정화공법에 의한 인공습지 축산폐수처리 시스템의 최적 조합방법 및 부하량)

  • Park, Jong-Hwan;Seo, Dong-Cheol;Kim, Ah-Reum;Kim, Sung-Hun;Lee, Seong-Tae;Jeong, Tae-Uk;Choi, Jeong-Ho;Kim, Hyun-Ook;Cho, Ju-Sik;Heo, Jong-Soo
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.44 no.2
    • /
    • pp.278-284
    • /
    • 2011
  • To obtain optimum configuration method and livestock wastewater loading in small-scale livestock wastewater apparatus by natural purification method for treating livestock wastewater, the small-scale livestock wastewater apparatuses were constructed with 9 kinds of combined systems such as aerobic bed (ae)-anaerobic bed (an), ae-ae, ae-anoxic bed (ox), an-an, an-ae, an-ox, ox-ae, ox-an and ox-ox livestock wastewater treatment apparatuses. Under different configuration methods, the removal rate of COD in Ae-Ae and Ae-An livestock wastewater treatment apparatus was higher than that in other configuration methods. The removal rate of T-N in Ae-An livestock wastewater treatment apparatus was higher than that in other configuration methods. Removal rates of SS and T-P were not different regardless of configureation methods in small-scale livestock wastewater treatment apparatus. Under different livestock wastewater loading, the removal rates of pollutants were higher in the order of $50L\;m^{-2}\;day^{-1}{\fallingdotseq}100L\;m^{-2}\;day^{-1}\;>\;200L\;m^{-2}\;day^{-1}$. Therefore, optimum configuration method was Ae-An livestock wastewater treatment apparatus, and optimum livestock wastewater loding was $100L\;m^{-2}\;day^{-1}$ in small-scale livestock wastewater treatment apparatus.

Tank-mix Feasibility Reducing the Application Rate of Quinclorac (Quinclorac 함량감소(含量減少)를 위한 혼합처방(混合處方)의 가능성(可能性) 연구(硏究))

  • Guh, J.O.;Han, S.U.;Chon, S.U.
    • Korean Journal of Weed Science
    • /
    • v.13 no.1
    • /
    • pp.14-18
    • /
    • 1993
  • Greenhouse study was undertaken to find tank-mix feasibility of quinclorac with molinate and propanil, selective post-emergence herbicides in controlling barnyardgrass, for reducing the application rate of quinclorac. Following foliar application in combination of quinclorac at 0.038, 0.075, 0.150, and 0.300kg ai/ha with molinate at 0.190, 0.380, 0.750 and 1.500kg ai/ha, and propanil at 0.263, 0.525, 1.050, and 2.100kg ai/ha at 3.5-leaf stage of barnyardgrass, fresh weight and weeding efficacy and their interaction by Colby's efficacy method were evaluated. Percent inhibition of barnyardgrass growth by quinclorac, molinate and propanil at recommended rate were 78.1, 26.1, and 61.7%, respectively. The dose combination shown above 85% in weeding efficacy were from 0.300kg of quinclorac with 0.75kg of molinate and 0.150kg of quinclorac with all rates of propanil. Therefore, combination of quinclorac with molinate tended to additive interaction and that of quinclorac with propanil appeared partially synergistic interaction. Conclusively, for reducing the application rate of quinclorac, the combination of quinclorac with propanil was more synergistic than that of quinclorac with molinate.

  • PDF

ECO(Electro-Coagulation & Oxidation) 공법에서 전극 및 전류밀도에 따른 축산폐수 처리특성 변화

  • Kim, Hak-Seok;Kim, Hong-Tae;Kim, Jeong-Bae;Lee, Du-Hui
    • Proceedings of the Korean Environmental Sciences Society Conference
    • /
    • 2008.11a
    • /
    • pp.510-514
    • /
    • 2008
  • 본 연구에서는 전극의 특성에 따른 돈사유래 축산폐수의 ECO 공법에 의한 처리특성을 평가하기 위해 ECO 시스템 모듈내 Fe-Fe 및 Al-Al 계열의 용해성 전극과 Al-SUS, Ir-SUS 등 불용성 전극을 대상으로 5$\sim$20mA/cm$^2$의 전류밀도하에서 축산폐수내 유기물 및 영양염류의 제거특성을 평가하여 다음과 같은 결론을 얻을 수 있었다. 1. 전기응집산화에 의한 축산폐수의 처리시 수중 유기물질 및 영양염류의 제거효율은 전류밀도의 증가에 비례하여 증가한다. 2. 불용성 전극조합 및 불용성-용해성 전극조합은 전류밀도가 높을수록 수중 유기물 및 오염물질 제거효율이 안정되고, 용해성 전극은 15mA/cm$^2$ 이하의 저 전류밀도의 조건하에서 전류밀도의 증가에 따라 안정된 제거효율 향상을 기대할 수 있다. 3. 불용성전극 조합인 Ir-SUS 전극조합을 사용하여 축산폐수를 처리할 경우 COD$_{Mn}$ 제거효율을 약 10% 향상시킬 수 있으며, TN 20mA/cm$^2$에서 Al-Al 전극조합과 TP 15mA/cm$^2$ 이하에서 Fe-Fe 전극조합은 제거효율이 저하되는 경향이 나타난다.

  • PDF

Wine Label Character Recognition in Mobile Phone Images using a Lexicon-Driven Post-Processing (사전기반 후처리를 이용한 모바일 폰 영상에서 와인 라벨 문자 인식)

  • Lim, Jun-Sik;Kim, Soo-Hyung;Lee, Chil-Woo;Lee, Guee-Sang;Yang, Hyung-Jung;Lee, Myung-Eun
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.5
    • /
    • pp.546-550
    • /
    • 2010
  • In this paper, we propose a method for the postprocessing of cursive script recognition in Wine Label Images. The proposed method mainly consists of three steps: combination matrix generation, character combination filtering, string matching. Firstly, the combination matrix generation step detects all possible combinations from a recognition result for each of the pieces. Secondly, the unnecessary information in the combination matrix is removed by comparing with bigram of word in the lexicon. Finally, string matching step decides the identity of result as a best matched word in the lexicon based on the levenshtein distance. An experimental result shows that the recognition accuracy is 85.8%.

Optimum Configuration, Filter Media Depth and Wastewater Load of Small-scale Constructed Wetlands for Treating the Hydroponic Waste Solution in Greenhouses (시설하우스 폐양액 처리를 위한 소형 인공습지의 최적 조합방법, 여재깊이 및 폐양액 부하량)

  • Park, Woo-Young;Seo, Dong-Cheol;Lim, Jong-Sir;Park, Seong-Kyu;Cho, Ju-Sik;Heo, Jong-Soo;Yoon, Hae-Suk
    • Korean Journal of Environmental Agriculture
    • /
    • v.27 no.3
    • /
    • pp.217-224
    • /
    • 2008
  • To obtain optimum configuration, depth and load of constructed wetlands(CWs) for treating of hydroponic waste solution(HWS) which was produced in greenhouses, the study was conducted with 4 kinds of combined systems such as Vertical flow(VF)-Horizontal flow(HF), VF-VF, HF-VF and HF-HF CWs. In four configurations of CWs, the treatment efficiency of pollutants from HWS under depth of HF and VF beds, HWS loading and HWSs were investigated. Removal rate of pollutants under different depth of VF and HF in 2-stage hybrid CWs was in the order of 50 cm < 70 cm regardless of CWs configuration. Removal rate of pollutants under HWS loading in 2-stage hybrid CWs was in the order of $150L\;m^{-2}\;day^{-1}{\fallingdotseq}300L\;m^{-2}\;day^{-1}\;>\;450L\;m^{-2}\;day^{-1}$. The optimum depth and HWS loading were 70 cm and $300L\;m^{-2}\;day^{-1}$ in four configurations of CWs, respectively. Using this optimum condition, for various HWSs (cucumber, paprika and strawberry HWS), removal rate of pollutants in HF-HF CWs was higher than that in HF-VF CWs. Optimum configuration of 2-stage hybrid CWs for treating hydroponic waste solution in greenhouses was found out to be HF-HF CWs. Therefore, under the optimum conditions, removal rate of BOD, COD, SS, T-N and T-P in HF-HF CWs were 84, 81, 84, 51 and 93%, respectively.