• Title/Summary/Keyword: 처리수 배출장치

Search Result 127, Processing Time 0.03 seconds

Removal of Phenanthrene by Electrokinetic-Fenton Process in a 2-dimensional Soil System (동전기-펜턴 공정을 이용한 2차원 토양 정화장치에서의 phenanthrene 제거)

  • Park Ji-Yeon;Kim Sang-Joon;Lee You-Jin;Yang Ji-Won
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.5
    • /
    • pp.11-17
    • /
    • 2005
  • Characteristics of phenanthrene removal in the Electrokinetic (EK)-Fenton process were investigated in a 2-dimensional test cell in a viewpoint of the effect of gravity and electrosmotic flow (EOF). When the constant voltage of 100 V was applied to this system, the current decreased from 1,000 to 290 mA after 28 days, because soil resistance increased due to the exhaustion of ions in soil by electroosmosis and electromigration. Accumulated EOF in two cathode reservoirs was 10.3 L and the EOF rate was kept constant for 28 days. At the end of operation, the concentration of phenanthrene was observed to be very low near the anode and increased in the cathode region because hydrogen peroxide was supplied from anode to cathode region following the direction of EOP. Additionally, the concentration of phenanthrene decreased at the bottom of the test cell because the electrolyte solution containing hydrogen peroxide was largely transported toward the bottom due to a low capillary action in the soil with high porosity. Average removal efficiency of phenanthrene by EK-Fenton process was 81.4% for 28 days. In-situ EK-Fenton process would overcome the limitations of conventional remediation technologies and effectively remediate the contaminated sites.

Sterilization of Neurospora Crassa by Noncontacted Low Temperature Atmospheric Pressure Surface Discharged Plasma with Dielectric Barrier Structure (유전체장벽 방전구조의 비접촉식 저온 대기압 면방전 플라즈마를 이용한 빵곰팡이의 살균효과)

  • Ryu, Young Hyo;Uhm, Han Sup;Park, Gyung Soon;Choi, Eun Ha
    • Journal of the Korean Vacuum Society
    • /
    • v.22 no.2
    • /
    • pp.55-65
    • /
    • 2013
  • Sterilization of Neurospora crassa has been investigated in this research by using a surface air plasma with dielectric barrier discharged (DBD) structure under atmospheric pressure. The sinusoidal alternating current has been used in this experiment with discharge voltage of 1.4~2.3 kV. The phase difference between the voltage and current signals are found to be almost 80 degree due to the capacitive property of dielectric barrier. Temperature on the biomaterials has been minimized by radiating the heat with the air cooling system. It is noted that the substrate temperature remains under 37 degree for plasma exposure time of 10 minutes with operation of cooler system. It is found that the ozone, $O_3$, has been measured to be about 25~30 ppm within 1 cm region and to be about 5 ppm at the 150 cm downstream region away from the suface plasma. It is also noted that the nitric oxide, NO, and nitric dioxide, $NO_2$, are not nearly detected. Germination rate and mitochodrial activity of Neurospora crassa immersed in the deionized water have been found to be drastically decreased as the plasma treatment time and its electrical power are increased in this experiment. Here, the mitochondrial activity has been analyzed by MTT (3-(4,5-dimethy lthiazol-2yl)-2,5-diphenyl-2H-tetrazolium bromide) assay. However, sterilization of Neurospora crassa immersed in the Vogel's minimal media has been found to be low by plasma treatment, which is caused by surrounding background solution. This research shows the sterilization possibility of Neurospora crassa by using the noncontated surface DBD plasma, which is different from the plasma jet. This is mainly attibuted to the reactive species generated by the surface plasma, since they play a major role for inhibition of micobes such as Neurospora crassa.

Trends of Technology Development through Investigation and Analysis of Domestic Patent Related to Wastewater Treatment Technology including Membrane, Sludge Treatment and Advanced Treatment Technology and Equipment (분리막 및 슬러지 처리와 고도처리 기술·장비를 포함한 하·폐수 처리기술의 특허 조사·분석을 통한 기술개발 동향)

  • Yoo, Ho Sik;Kim, Ji Tae
    • Membrane Journal
    • /
    • v.27 no.5
    • /
    • pp.375-388
    • /
    • 2017
  • Wastewater treatment (WWT) technology has been developing from simple pollutant treatment to energy and resource-saving advanced technology, and various technologies combined with IT and BT are developed to minimize the amount of pollutant and toxic substance discharge to the public water areas and to improve operational efficiency. To examine the development trend of domestic wastewater treatment technology, the registered patent technologies were surveyed, classified and analyzed by year and sector. This paper considers the status of patent registration related to WWT from 2010.1 to 2017.5 in terms of the number of specific technical areas, and the trends are analyzed based on the 10 categorization field such as biological and physicochemical treatment process, equipment and device, material, sludge treatment, membrane, process control and 42 specific technical areas. A total of 3,356 patents have been registered since 2010, and the number of patents has been decreasing since the peak at 2013 and maintains 3~400 per year. The total number of patents has not yet been less than other countries, but the number of patents of more advanced technologies, which can lead the global market, such as process monitoring, new concept processing and equipment technologies is still insufficient compared to developed countries.

An Experimental Study on the Parallel plate Arrangement and Oil/water Separation Efficiency for Plate type Oily water Separator (분리판식 유수분리기의 평행판 배열과 유수분리 효율에 관한 실험적 연구)

  • Han Won-Hui;Kim Gwang-Su;Lee Jin-Yeol
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.4 no.2
    • /
    • pp.52-60
    • /
    • 2001
  • The need to control the oil content in oily bilge water discharges to meet the increasing stringent seawater pollution standards has led to the development of gravity type separators. Among the several gravitational methods, a plate type oily water separator can be used as an assistant equipment for the oil filtering system to meet the present IMO standard of 15 ppm, because it is believed to be an efficient method dealing with a large amount of rich oil with high specific gravity. The purpose of this paper is to examine the efficiency of oil/water separation with the characteristics of separating plate arrangement. An experimental study was carried out to analyse an efficient treatment oil-water mixture with variation of operating parameters, including flow rates, inlet oil concentrations and the height between the plates. The experimental results show that the height between the plates has a significant effect on the separation efficiency. The best efficiency was acquired when the ration of the height between the plates the plates to distance(H/Ci) was 2 with lower inlet oil concentration and lower flow rate.

  • PDF

생물공정의 측정 및 새로운 공정변수의 개발

  • Heo, Won
    • 한국생물공학회:학술대회논문집
    • /
    • 2000.04a
    • /
    • pp.51-52
    • /
    • 2000
  • 생물공정의 운전에 있어서 적절한 공정변수가 부족한 경우가 많다. 이것은 멸균과정을 견딜 수 있는 신뢰성 높은 센서가 부족하기 때문이다[1]. 생물공정에 주로 사용되는 센서로서는 온도, pH, D.O., rpm, viscosoty 등이 있으나 이 센서들은 배양액의 물리적 혹은 화학적 상태를 측정할 수 있는 경우가 대부분이다[2]. 미생물의 대사활동과 관련이 있는 공정 변수로는 배출가스의 성분을 측정하여 얻을 수 있는 Oxygen uptake rate, Carbon dioxide evolution rate 및 Respiratory quotient가 있으며 현재 생물공정의 운전에 사용되고 있다[3]. 그러나 반복적인 센서의 보정과 연결관의 잦은 청소 및 보수를 필요로 하여 제한적으로 사용되고있는 실정이다. 자동화된 습식분석장치, Gas chromatograph, High Performace Liquid Chromatograph 혹은 Mass spectrophtometry 등을 온라인 샘플 처리장치와 연결하여 발효조의 배양액의 성분을 온라인으로 분석하고 공정의 운전에 응용하는 사례가 많이 발표되었다[4-6]. 고가의 장비 및 운전의 번거러움이나 추가적인 인력이 필요하므로 역시 특별한 경우에만 사용되고 있다. 이외에도 여러 종류의 온라인 센서 및 바이오 센서등이 개발되어 사용되고 있으나 역시 그 사용범위는 특수한 영역에 한정되어있다. 이와 같이 새로운 센서를 개발하여 공정변수를 측정하려는 시도중의 하나가 소프트웨어 센서의 개발이다. 이 것은 공정상에서 발생하는 1차 공정변수를 이용하여 배양액의 상태 혹은 2차적인 공정 변수를 추측해내는 것이다. 대부분의 경우 기존의 공정 변수를 사용하므로 추가적인 비용이 들지 않고 소프트웨어의 형태로 구현되므로 센서의 보정과 설치 및 유지관리의 노력이 매우 적은 장점이 있다. 본 연구에서는 생물공정에서 자동제어 과정에서 발생하는 여러 가지 공정상의 제어 신호로부터 새로운 공정 변수를 얻어내고자 시도하였다. 대부분의 생물공정에서는 pH의 자동제어가 필수적인데 자동제어 과정에서 발생하는 pH 제어 신호 및 pH의 변화 응답신호를 이용하여 배지의 완충용량의 변화와 알칼리의 소비속도를 온라인으로 측정할 수 있었다. 여기에 인공지능망을 설계하여 균체의 량을 온라인으로 추정하는 방법을 개발하였다 [7].산업용 발효조의 운전 온도는 주로 냉각수의 단속적인 공급에 의하여 항상 일정하게 조절된다. 따라서 냉각수의 냉각량을 측정하면 미생물의 배양시 발생하는 대사열량을 측정할 수 있게 된다. 본 연구에서는 실험실의 발효조를 냉각수의 단속적인 공급에 의하여 자동온도 조절이 되도록 개조하고 여기에 냉각수의 유출입 지점에 온도센서를 부착하여 냉각수의 온도를 측정하고 냉각수의 공급량과 대기의 온도 등을 측정하여 대사열의 발생을 추정할 수 있었다. 동시에 이를 이용하여 유가배양시 기질을 공급하는 공정변수로 사용하였다 [8]. 생물학적인 폐수처리장치인 활성 슬러지법에서 미생물의 활성을 측정하는 방법은 아직 그다지 개발되어있지 않다. 본 연구에서는 슬러지의 주 구성원이 미생물인 점에 착안하여 침전시 슬러지층과 상등액의 온도차를 측정하여 대사열량의 발생량을 측정하고 슬러지의 활성을 측정할 수 있는 방법을 개발하였다.

  • PDF

Evaluation of CO2 Balance in the Barley-Red Pepper and Barley-Soybean Cropping System (보리-고추와 보리-콩 작부체계에서 이산화탄소수지 평가)

  • Kim, Gun-Yeob;Suh, Sang-Uk;Ko, Byung-Gu;Jeong, Hyun-Cheol;Roh, Kee-An;Shim, Kyo-Moon
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.41 no.6
    • /
    • pp.408-414
    • /
    • 2008
  • Importance of climate change and its impact on agriculture and environment has increased with the rise Green House Gases (GHGs) concentration in the atmosphere. To slow down the speed of climate change many efforts have been applied in industrial sectors to reduce GHGs emission and to enhance carbon storage. In agricultural sector, many researches have been performed on GHGs emission reduction, but few on the role of carbon sink. In this study, we investigated carbon balance and soil carbon storage in agricultural field in the barley-red pepper and barley-soybean cropping system. With the system for automatic measuring of carbon dioxide, net ecosystem production(NEP) was estimated to be $6.3ton\;CO_2\;ha-1$ for N-P-K chemical fertilizer treatment plot and $10.6ton\;CO_2\;ha^{-1}$ for N-P-K chemical fertilizer with swine manure treatment plot in the barley-soybean rotation cropping. In the barley-red pepper rotation cropping, it was $12.0ton\;CO_2\;ha^{-1}$ for N-P-K chemical fertilizer treatment plot and $13.2ton\;CO_2\;ha^{-1}$ for N-P-K chemical fertilizer with swine manure treatment plot. Soil carbon storage rate was estimated to be $0.7ton\;C\;ha^{-1}$ for the barley-soybean cropping system and $0.5ton\;C\;ha^{-1}$ for barley-pepper cropping system. In appeared that agricultural lands may contribute to the greenhouse effect as a potential carbon sink preserving carbon into soil.

Development of Separation System with Rotating Rakes for Recovery of Film-based Plastics (기계식(機械式) 회전(回轉)레이크를 이용(利用)한 생활계(生活界) 폐기물(廢棄物) 필름류(類) 선별장치(選別裝置) 개발(開發)에 관(關)한 연구(硏究))

  • Lee, Byung-Sun;Na, Kyung-Duk;Han, Sang-Kuk;Choi, Woo-Zin;Park, Eun-Kyu
    • Resources Recycling
    • /
    • v.19 no.3
    • /
    • pp.24-32
    • /
    • 2010
  • In the present work, a new separation system with rotating rakes has been developed to separate the film-based plastics from the recyclable materials, and environment assessment is also carried out during operation of the device. Capacity of the device was about 5.3 ton/hr at a rakes rotation speed of 26.0 rpm (the number of rakes in the 1st, 2nd and 3rd trials were 39, 52 and 48, respectively) and a belt conveyor speed of 38.5m/min, which satisfied the initial design capacity (5.0 ton/hr). Recovery ratio and purity of the plastic films were 92.6% and 96.5%, respectively at a rotation speed of 28 rpm. The levels of noise, vibration and particulate emission were below material standard regulatory limits. Plastic refused fuel (RPF) was also prepared with the recovered films. The calorific value and chlorine content of the prepared RPF were 9,740 kcal/kg and 0.18%, respectively which satisfy the first grade quality specification of the Korean RPF standard. As a result of this work, recovery of energy resources from the municipal solid waste is possible by adopting the developed separation device.

Analysis of micro inorganic materials in linerboard mill (골판지 원지 제조 공정 내 미세 무기물질의 분석)

  • 윤혜정;류정용;김용환;신종호;송봉근
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.11a
    • /
    • pp.132-132
    • /
    • 2000
  • 환경오염과 이상기후의 영향으로 인한 수자원의 고갈과 함께 국내의 경우 수자원 개발 계획 및 수요량을 감안할 때 향후 7 년 내에 물부족 현상을 겪을 것이라는 보고가 있 었으며, 환경부담을 줄이기 위해 폐수의 배출기준은 강화되고 있다. 이러한 상황에서 제조 특성상 타 업종에 비해 폐수 발생량이 높은 편인 국내의 제지산업은 여러 해전부터 이에 대 한 방안을 모색하여 왔다. 일반적으로 폐수 수질 관리와 청수 사용량의 절감을 위해 고가의 폐수 처리 장치를 설치하거나 폐수 재활용을 통해 공정을 극도로 폐쇄화하는 방안으로 연구 가 진행되어 왔다. 이 중 용수의 재활용이 가장 경제적인 방법이지만, 재활용이 지속될수록 각종 무기염과 콜로이드성 유기물질이 축적되어 각종 약품의 효능 저하, 탈수속도의 저하 및 생산 제품의 품질 악화 등의 문제를 유발한다고 알려져 있다. 이를 해결하고자 하는 노 력으로 펄프 원료에 따른 공정수 내 용해성 물질의 분석과 재활용 횟수에 따른 각종 SS와 D DS의 축적 정도에 대한 기초 연구가 수행되었으며, 고폐쇄화된 공정에서 성능을 발휘할 수 있는 첨가제의 개발과 적용 방법에 대한 연구도 수행된 바 있다.여러 지종 가운데 골판지 원지는 용수의 재활용률이 상당히 높은 지종이기 때문에 공정수의 재활용이 진행될수록 열악한 저급 원료로부터 각종의 다양한 물질이 용출 혹은 배 출되며, 이러한‘물질은 골판지 원지의 강도 발현에 더욱 악영향을 미칠 것으로 판단되었다. 미세분으로 구성된 SS의 경우 이미 많은 연구를 통해 특성이 파악되었기 때문에 본 연구에 서는 ss를 제외한 공정수를 두 가지로 크게 나누어 고려하였다. 즉, ss로 측정되지 않지만 닥도를 유발할 수 있는 미세 무기물질과, 용해성의 무기염, 첨가제 및 추출물 둥으로 이루어 진 용해성 성분으로 나누어 분석하였으며, 또한 각각이 초지 특성에 미치는 영향을 살펴보 고자 하였다.을 해석코자 하였으며, 그 방법으 로 수치해석기법을 도입하였다. 또 실제 캘린더링 전후의 두께 변화를 측정하여 유리전이온도 의 도달 깊이와 비교하였다. 지필의 압축 정도는 롤의 직경과 닙 폭을 이용하여 MD 방향으 로 함수화하였으며, 열전달 계수로는 겉보기 값을 사용하였다. 이때 지펼은 균질한 것으로 가 정하였다. 함수율은 유리전이온도를 좌우하는 가장 큰 인자이나 본 연구에서는 항온항습처리 를 통해 유입지의 함수율을 고정시켰으며 캘린더링 시 함수율의 변이는 없다고 가정하였다. 그 결과 열침투깊이가 증가할수록 지필은 보다 변형되기 쉬운 상태가 되어 주어진 압력 조건에 대해 소성변형 정도가 증가하는 것으로 나타났다. 이는 캘린더링 전후에 두께 변화를 측정하여 정량적으로 평가할 수 있었다. 수치해석기법을 통해 같은 압력 조건에서 온도가 증 가함에 따라 혹은 같은 온도 조건에서 압력이 증가함에 따라 지필 내의 유리전이온도의 침투 깊이가 증가함을 알 수 있었으며 이는 캘린더링 전후의 두께 변화의 측정 결과와 일치하였 다. 또 NRT가 증가함에 따라서도 유리전이온도 침투 깊이가 증가하였다.합편에 비해 일부 우수한 양상을 보였지만 본 실험의 범위내에서는 통계적 정량적 차이를 제시할 수는 없었다. 향후 보다 광범위한 동물 실험이 필요할 것으로 사료된다.된다.하고도 완전교정술 도달 확률이 높은 치료전략이라는 사실을 입증하였으며 주대동맥폐동맥혈관부행지의 크기나 숫자가 단일화하기 쉬운 형태학적 특징을 지닌 경우에는 조기에 일단계완전교정술을 시행하여 양호한 결과를 얻을 수 있다는 사실을 발견하였다. 반면 본 환아군 중 단일화술을 먼저 시도한 군에서는 비록 단계적인 단일화를 시도한 군에서 단일화술과 관계된 수술사망율이 약간 낮기는 하였으나 완전교정술까지 완료될 가능성에는 차이가 없었다. 그러나 이 경우 보다 정련된 적응 환자의 선택을 통한 단일화 우선전략의 시도와 장기 추

  • PDF

Supercritical Water Oxidation of Anionic Exchange Resin (초임계수 산화를 이용한 음이온교환수지 분해)

  • Han, Joo-Hee;Han, Kee-Do;Do, Seung-Hoe;Kim, Kyeong-Sook;Son, Soon-Hwan
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.5
    • /
    • pp.549-557
    • /
    • 2006
  • The characteristics of supercritical water oxidation have been studied to decompose the waste anionic exchange resins which were produced from a power plant. The waste resins from a power plant were mixture of anionic and cationic exchange resins. The waste anionic exchange resins had been separated from the waste resins using a solid-liquid fluidized bed. It was confirmed that the cationic exchange resins were not included in the separated anionic exchange resins by the elemental and thermogravimetric analysis. A slurry of anionic exchange resins which could be fed continuously to a supercritical water oxidation apparatus by a high pressure pump was prepared using a wet ball mill. Although the COD of liquid effluent had been reduced more than 99.9% at 25.0 MPa and $500^{\circ}C$ within 2 min, the total nitrogen content was reduced only 41%. The addition of nitric acid to the slurry could reduce the total nitrogen content in treated water. The central composite design as a statistical desist of experiments had been applied to optimize the conditions of decomposing anionic resin slurry by means of the COD and total nitrogen contents in treated waters as the key process output variables. The COD values of treated waters had been reduced sufficiently to $99.9{\sim}100%$ af the reaction conditions of $500{\sim}540^{\circ}C$, 25.0 MPa within 2 min. The effects of temperature and nitric acid concentration on COD were not significant. However, the effect of nitric acid concentration on the total nitrogen was found to be significant. The regression equation for the total nitrogen had been obtained with nitric acid concentration and the coefficient of determination($r^2$) was 95.8%.

The Electrochemical Chlorination for Marine Plankton Community Disinfection (해양 플랑크톤 군집의 전기분해 염소소독 효과)

  • Kang, Jung-Hoon;Shin, Kyoung-Soon;Hyun, Bong-Gil;Jang, Min-Chul;Kim, Eun-Chan;Chang, Man
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.10 no.3
    • /
    • pp.127-137
    • /
    • 2007
  • To confirm whether or not the Electrochemical Disinfection System (EDS) meet with the D-2 regulation established by IMO (International Maritime Organization), the biological treatment efficacy of the EDS was assessed using three groups of natural marine plankton (bacteria, $10-50\;{\mu}m$ and $>50\;{\mu}m$ sized organisms). Influent water was passed through the EDS under the flow velocity ($23.8\;m^3/hr$) and test design was consisted of control (no treatment) and experimental (10 ppm and 30 ppm) condition for total residual chlorine (TRC). And the biological condition of the influent water followed the standards established by the guidelines for the approval of ballast water management systems. The disinfection efficacy of the $10-50\;{\mu}m$ sized organisms (phytoplankton) was assessed by three kinds of measurements using photomicroscope, epifluorescence microscope and fluorometer (fumer Designs 10-AU). After being passed through the EDS, all motile phytoplankton lost their motility under photomicroscope, the colour of chlorophyll fluorescence fumed from red into green under epifluorescence, and the high chlorophyll fluorescence (Expt. 1: 6.95, Expt. 2: 7.11) detected by fluorometer decreased into value not detected. These results indicated phytoplankton community was totally killed after electrochemical disinfection treatment. Survivorship of the larger organisms than $50\;{\mu}m$ was determined based on the appendage's movement under a stereomicroscope. Natural assemblage collected from ambient seawater was killed shortly after being passed through the EDS, whereas some Artemia remained alive. However, no live Artemia was found after 24 hour further exposure to each TRC concentration (10 and 30 ppm) under darkness. After electrochemical treatment, the target bacteria such as aerobes, coliform and Escherichia coli were completely killed on the basis of CFU (colony forming unit) on Petrifilm plate ($3\;M^{TM}$) after 48 hr incubation. Moreover, no regrowth was found in the three groups of plankton during five days under additional exposure to the treated water. These results indicated that the disinfection efficiency of the EDS on the three groups of plankton satisfy D-2 regulation.

  • PDF