A Study on the Analysis of Gaze Characteristic of The Villa Savoye - Based on the Difference between Architecture Major Group and Non-Architecture Major Group (빌라 사보아의 건축입면 주시특성 연구 - 건축 전공자와 비전공자의 차이를 중심으로)

  • Cho, Hyeong-Kyu
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.11
    • /
    • pp.724-731
    • /
    • 2016
  • The purpose of this study was to determine what rules or patterns exist when people gaze at a villa savoye, which is probably Le Corbusier's best known building, using eye-movement tracking techniques. Villa savoye was designed, addressing his emblematic "Five Points", such as pilotis, functional roofs, free floor plans, long horizontal windows, and freely-designed facades. This study examined how the villa savoye's facade image is formed in an objective manner. This study selected a total of 56 test subjects, and showed them an image of a villa savoye. Using eye-movement tracking tools, this study recorded where they mostly gazed at when seeing the building. In addition, an experiment was carried out to test the different points of view, relating to visual attention, between the two groups with different levels of knowledge in architecture. To analyze the data, the Gaze Frequency was used as the key indicator. The results showed that the subjects have a higher degree of attention to either the door or window in general than in former studies. The architecture major group showed that they gazed the experiment image more evenly.

NIR reflecting properties of TiO2/Ag/TiO2 multilayers deposited by DC/RF magnetron sputtering (DC/RF 마그네트론 스퍼터링법을 이용한 TiO2/Ag/TiO2 하이브리드 다층박막의 적외선 반사 특성)

  • Kim, Seong-Han;Kim, Seo-Han;Song, Pung-Geun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2016.11a
    • /
    • pp.158-158
    • /
    • 2016
  • 최근 화석연료의 고갈과 환경 보전 및 에너지 절약에 대한 관심이 높아짐에 따라 화석연료의 소비를 최소화하고 실내조건을 쾌적하게 유지하려는 연구가 진행되고 있다. 국내의 경우 전체 에너지 소비의 30%이상을 차지하고 있는 건물부문에서의 에너지 소비를 줄이기 위한 활발한 연구가 진행되고 있으며 이에 따른 에너지절약 소재개발이 활발하게 진행되고 있다. 1975년 이후 여러 차례에 걸친 단열강화 조치를 통해 건물에서의 에너지 소모를 줄이고 있었으나 건물의 외벽에 대한 사항으로 한정되어있었고, 또한 건물의 창 면적이 증가함에 따라 창을 통한 열손실량과 열획득량이 더욱 증가하게 되었다. 이러한 문제를 해결하기 위해 열반사유리에 대한 많은 연구가 진행되고 있다. 열반사유리는 근적외선(열선)영역의 빛을 반사시켜 실내의 열손실량 및 외부에서의 열획득량을 감소시켜 에너지의 소비를 줄일 수 있는 유리을 말한다. 이러한 열반사유리은 fresnel 방정식을 통해 빛의 파장대에 따른 반사율 및 투과도를 예측할 수 있는데, 다층박막구조인 Oxide-Metal-Oxide(OMO)구조는 Oxide의 높은 굴절률과 Metal의 낮은 굴절률을 통해 가시광영역대의 높은 투과도와 근적외선 영역의 높은 반사율을 얻을 수 있다. 또한 Metal층을 삽입함으로서 flexible한 코팅이 가능하고, 높은 carrier density와 mobility로 표면 플라즈몬 공명을 통해 특정 파장대의 반사율을 높일 수 있으므로 많은 연구가 진행되고 있다. $TiO_2$는 고굴절률 및 낮은 광흡수성의 특성을 가지는 산화물반도체로 기존의 $In_2O_3$계 산화물에 비해 값이 싸고 높은 안정성과 광촉매특성을 보이므로 외부에 노출된 환경에 적합한 재료이다. Ag는 저굴절률과 낮은 광흡수성을 가지는 재료로 금속층에 적합하다. 본 연구에서는 fresnel 방정식을 통해 반사도 및 투과도를 예측하고 마그네트론 스퍼터링법으로 다층박막을 열선인 적외선 영역에서의 반사율 및 반사 효율을 평가하였다. Index-matching 시뮬레이션을 통해 $TiO_2/Ag/TiO_2$ 다층박막의 투과도와 반사도를 이론적으로 검토하였다. 시뮬레이션 프로그램은 Macleod프로그램을 이용하였고 재료 각각의 굴절률은 Ellipsometry를 이용하여 측정하였다. 두께 40 nm 와 8 ~ 16 nm를 가지는 $TiO_2$층과 Ag층을 각각 RF/DC 마그네트론 스퍼터링법을 이용하여 Glass기판 위에 증착하였다. 직경 3 in 의 $TiO_2$, Ag 소결체 타깃을 이용하였고 스퍼터링 파워는 각각 200 W, 50 W로 설정하였고, 스퍼터링 가스는 Ar가스의 유량을 20 sccm으로 설정하였다. 작업압력은 모두 1 Pa로 설정하였고 타깃 표면의 불순물 및 이물질 제거를 위해 Pre-sputtering을 10분 진행하였다. 박막의 두께는 reflectometer와 Alphastep을 이용하여 측정하였고 Hall effect measurement를 이용하여 비저항, carrier density, mobility등 전기적 특성을 측정하였다. 또한 UV-VIS spectrometer와 USPM-RU-W NIR Micro-Spectrophotometer를 통해 광학적 특성을 측정하였고 계산 값과 비교분석하였다. 또한 열반사 특성을 평가하기 위해 직접 set-up한 장비를 이용하였다. 단열 박스에 샘플을 장착해 적외선 램프를 조사하였을 때의 열 반사효율을 평가하였고, IR Camera를 이용하여 단열 박스 내부의 온도 변화를 관찰하였다.

  • PDF

0.6 mAh All-Solid-State Thin Fim Battery Fabricated on Alumina Substrate (알루미나 기판상에 구현된 0.6mAh급 전고상 박막전지)

  • Park, H.Y.;Nam, S.C.;Lim, Y.C.;Choi, K.G.;Lee, K.C.;Park, G.B.;Cho, S.B.
    • Journal of the Korean Electrochemical Society
    • /
    • v.8 no.4
    • /
    • pp.181-185
    • /
    • 2005
  • Lithium cobalt oxide thin film cathode, having thickness of $2.9{\mu}m$ with area of $4cm^2$, was deposited on platinum patterned alumina substrate by radio frequency magnetron sputtering. Li/Co molar ratio, which is an important factor for battery performance, was measured as a function of argon working pressure and applied R.F. power. Constant current charge and discharge performances were characterized with high rate discharge and cycling behavior. Using AC impedance analysis, internal resistance of the thin film battery was measured and simulated by proposed equivalent circuit model.

A Study on the Development of the Active Radar Reflector with Enhanced Structure (개선 된 구조를 갖는 능동 레이더 반사기 개발에 관한 연구)

  • 정종혁;강상욱;조영창;최병진;윤정오;홍영호
    • Proceedings of the Korea Society for Industrial Systems Conference
    • /
    • 2000.05a
    • /
    • pp.59-64
    • /
    • 2000
  • Active radar reflector may be less familiar, since their uses have been limited to military applications, especially the enhancement of the effective radar cross-sections of missile test range in the drone aircraft and missiles. Perhaps the most widely-blown applications of radar transponders are Identification Friend or Foe(IFF) and its civilian counterpart, secondary surveilliance radar for Air Traffic Control(ATC), and most recently, as Search And Rescue Transponder(SART) in the Global Maritime Distress and Safety System(GMDSS). Since it happens frequently accidents on the sea, the problems of the contamination more seriously considered. The conventional navigation buoy and utilities are not sufficient to maintain the safety of the sea and thus new structured concept must be considered. Therefore, this paper propose and implement the active radar reflector with a enhanced structure. The results are shown that the performance of the system is significantly improved comparing with the conventional utilities.

  • PDF

Potential Performance Enhancement of Dual Heat Pump Systems through Series Operation (히트펌프 직렬운전에 의한 성능 향상 가능성에 관한 연구)

  • Baik, Young-Jin;Kim, Min-Sung;Chang, Ki-Chang;Lee, Young-Soo;Kim, Hyeon-Ju
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.8
    • /
    • pp.797-802
    • /
    • 2012
  • In this study, the potential performance enhancement in a dual heat pump system through series operation was investigated by a comparison between the performance for parallel and series operation for a heating supply temperature of $60^{\circ}C$. To compare the performance of each configuration fairly, the heat transfer surface area of the heat exchangers was fixed. The inlet temperatures and the flow rates of the heat source and the load were also fixed. In addition, the heat transfer and pressure drop characteristics of the working fluids were considered to achieve a more realistic comparison. The results show that the heating coefficient of performance (COP) of the series configuration is approximately 5% higher than that of the parallel configuration under the simulation conditions considered in the present study.

Impact of Horizontal Global Solar Radiation Calculation Modelson Building Energy Performance Analysis Considering Solar Heat Gain Coefficient and Window-to-wall Ratio (수평면 전일사량 산출모델이 일사열취득계수 및 창면적비를 고려한 건물 에너지 성능분석에 미치는 영향)

  • Kim, Kee Han;Oh, John Kie-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.39-47
    • /
    • 2014
  • Solar applications analysis and building energy performance depend on the quality of the solar resource data available. Unfortunately, most of the weather stations do not measure solar radiation data in Korea, as a reason many researchers have studied different solar radiation estimation models and suggested to apply them to various locations in Korea. In addition, they also studied the impact of hourly global solar radiation on energy performance of an office building by comparing the simulated building energy consumptions using four different weather files, one using measured, and three estimated solar radiation from different models, which are Cloud-cover Radiation Model (CRM), Zhang and Huang Model (ZHM), and Meteorological Radiation Model (MRM), and concluded that there was some impact on energy performance of the building due to the using different solar radiation models. However, the result cannot be applied to all other buildings since the simulated office building for that study only used limited building characteristics such as using fixed values of solar heat gain coefficient (SHGC) and window-to-wall ratio (WWR), which are significant parameters related to solar radiation that affect to the building energy consumptions. Therefore, there is a need to identify how the building energy consumption will be changed by varying these building parameters. In this study, the impact of one measured and three estimated global solar radiation on energy performance of the office building was conducted taking account of SHGC and WWR. As a result, it was identified that the impact of four different solar radiation data on energy performance of the office building was evident regardless SHGC and WWR changes, and concluded that the most suitable solar models was changed from the CRM/ZHM to the MRM as SHGC and WWR increases.

A Study on the Development of the Active Radar Reflector with Enhanced Function (개선된 기능을 갖는 능동 레이더 반사기 개발에 관한 연구)

  • 정종혁;강상욱;조영창;최병진;윤정오;오주환
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.3
    • /
    • pp.38-43
    • /
    • 2000
  • Active radar reflector may be less familiar, since their uses have been limited to military applications, especially the enhancement of the effective radar cross-sections of missile test range in the drone aircraft and missiles. Perhaps the most widely-Down applications of radar transponders are Identification Friend or Foe(IFF) and its civilian counterpart secondary surveilliance radar for Air Traffic Control(ATC), and most recently, as Search And Rescue Transponder(SART) in the Global Maritime Distress and Safety System(GMDSS). Since it happens frequently accidents on the sea, the problems of the contamination more seriously considered. The conventional navigation buoy and utilities are not sufficient to maintain the safety of the sea and thus new structured concept must be considered. Therefore, this paper propose and implement the active radar reflector with a enhanced function. The results are shown that the performance of the system is significantly improved comparing with the conventional utilities.

  • PDF

Effect of Combining Wood Flakes and Polypropylene-net Flakes on Thickness Swelling and Bending Properties of Sawdust Board (목질(木質)플레이크와 폴리프로필렌망(網)플레이크 구성(構成)이 톱밥보오드의 팽창성(膨脹性)과 휨성질(性質)에 미치는 영향(影響))

  • Lee, Phil Woo;Eom, Young Geun;Oh, Sei Chang;Chung, In Ju
    • Journal of Korean Society of Forest Science
    • /
    • v.77 no.2
    • /
    • pp.252-257
    • /
    • 1988
  • This study was carried out to investigate the physical and mechanical properties of sawdust boards combined with sycamore and polypropylene-net flakes. Both the sycamore and polypropylene-net flakes were adjusted to the sizes of $1.0{\times}1.0$, $1.0{\times}2.0$, and $1.5{\times}1.5cm^2$ and these flakes were mixed at 1, 2, 3, and 4% levels based on ovendry weights of sawdusts, respectively. The results obtained in this study were summarized as follows : 1. Thickness swellings of sawdust boards combined with sycamore flakes decreased with the increase of mixture levels and similar effects were also recognized in combination with polypropylene-net flakes. 2. Moduli of rupture both in sawdust boards combined with sycamore and polypropylene-net flakes increased with the increase of their mixture levels, and sawdust boards combined with sycamore flakes of $1.0{\times}2.0cm^2$ size and polypropylene-net flakes of $1.5{\times}1.5cm^2$ size showed higher moduli of rupture than control boards. 3. Moduli of elasticity both in sawdust hoards combined with sycamore and polypropylene-net flakes increased with the increase of their mixture levels as in moduli of rupture. 4. The physical and mechanical properties of sawdust boards combined with sycamore and polypropylene-net flakes were mainly dependent on aspect ratio of sycamore flakes and size of polypropylene-net flakes respectively, and these properties were improved with the respective increase of aspect ratio and size.

  • PDF

A Basic Study for Sustainable Analysis and Evaluation of Energy Environment in Buildings : Focusing on Energy Environment Historical Data of Residential Buildings (빌딩의 지속가능 에너지환경 분석 및 평가를 위한 기초 연구 : 주거용 건물의 에너지환경 실적정보를 중심으로)

  • Lee, Goon-Jae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.1
    • /
    • pp.262-268
    • /
    • 2017
  • The energy consumption of buildings is approximately 20.5% of the total energy consumption, and the interest in energy efficiency and low consumption of the building is increasing. Several studies have performed energy analysis and evaluation. Energy analysis and evaluation are effective when applied in the initial design phase. In the initial design phase, however, the energy performance is evaluated using general level information, such as glazing area and surface area. Therefore, the evaluation results of the detailed design stage, which is based on the drawings, including detailed information of the materials and facilities, will be different. Thus far, most studies have reported the analysis and evaluation at the detailed design stage, where detailed information about the materials installed in the building becomes clear. Therefore, it is possible to improve the accuracy of the energy environment analysis if the energy environment information generated during the life cycle of the building can be established and accurate information can be provided in the analysis at the initial design stage using a probability / statistical method. On the other hand, historical data on energy use has not been established in Korea. Therefore, this study performed energy environment analysis to construct the energy environment historical data. As a result of the research, information classification system, information model, and service model for acquiring and providing energy environment information that can be used for building lifecycle information of buildings are presented and used as the basic data. The results can be utilized in the historical data management system so that the reliability of analysis can be improved by supplementing the input information at the initial design stage. If the historical data is stacked, it can be used as learning data in methods, such as probability / statistics or artificial intelligence for energy environment analysis in the initial design stage.

Actual State of Structures and Environmental Control Facilities for Tomato Greenhouses in Chungnam Region (충남지역 토마토 재배온실의 구조와 환경조절설비 실태분석)

  • Nam, Sang-Woon;Kim, Young-Shik
    • Korean Journal of Agricultural Science
    • /
    • v.36 no.1
    • /
    • pp.73-85
    • /
    • 2009
  • An investigation was conducted to get the basic data for establishing structural safety and environmental management of tomato greenhouses in Chungnam region. The contents of the investigation consisted of actual state of greenhouse structures and environmental control facilities. Most of greenhouses were arch type single-span plastic houses and they had too low height for growing tomatoes. Frameworks of multi-span greenhouses were suitable, but those of single-span were mostly insufficient. Every greenhouse had thermal curtain movable or covering fixed inside the greenhouse for energy saving, and heating facilities were mostly warm air heater. Irrigation facilities were mostly drip tube and controlled by manual operation or timer. Almost all of the greenhouses didn't install high level of environmental control facilities such as ventilator, air circulation fan, $CO_2$ fertilizer, insect screen, supplemental light, and cooling device.

  • PDF