• Title/Summary/Keyword: 착용 기간

Search Result 106, Processing Time 0.034 seconds

Changes in Subjective Symptom, Tear Film Stabilization and Blinking Rates when Wearing RGP Lenses with Different Polishing Conditions for Certain Period of Time (연마상태가 다른 RGP렌즈의 일정기간 착용 시 렌즈착용자의 자각적 증상, 눈물막 안정 및 순목횟수 변화)

  • Park, Mijung;Kim, Hyo Gyum;Bae, Jun Seob;Park, Jung Ju;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.1
    • /
    • pp.31-42
    • /
    • 2014
  • Purpose: The present study was conducted to investigate the effect of the physical properties of RGP lens induced by lens polishing on the actual wearer's subjective comfort, the tear film break-up time and the blinking rate as a follow-up study that revealed the relationship between the lens physical properties during lens manufacturing and lens wearer's factors. Methods: RGP lenses made from the three different polishing conditions (25, 50 and 100 seconds) were applied on 28 eyes of 17 subjects, aged 20 to 29 years, without any known disease and surgical history in the eyes. While the subjects were asked to wear the RGP lenses longer than a week, the questionnaire for the comfortability was administered everyday. Subjective and objective tear break-up time and blinking rate of the wearers were further measured. Results: The wearer's subjective comfortability showed some difference in the type of discomfort and satisfaction score according to the polishing status when wearing RGP lenses made from different polishing conditions longer than a week, and a bigger difference in satisfaction score induced by polishing condition was especially shown in experienced RGP lens wearer rather than un-experienced wearer. In the case of RGP lens wearer compared with the ones without the wearing experience, as the wearing time increased subjective and objective tear break-up time were increased and the blinking rate was decreased. However, subjective and objective tear break-up time were tended to decrease with even longer wearing time when wearing the RGP lens made from the polishment for 100 seconds. Conclusions: These results confirmed that the optimization of physical properties of the lens may not give the same effect on the wearer's subjective and objective symptoms and other factors when actual wearing. From the results, it can suggest that the success rate of RGP lens wear may be changed by physiological factors such as the stabilization of wearer's tear film, comfortability and lens wearing experience when wearing RGP lens based on 'The manufacturing standard for soft contact lens/hard contact lens' provided by Korea Food and Drug Administration.

The Clinical Study on the Visual Acuity and Cornea of ez-NANOsence II RGP Contact Lens (ez NANOsence II RGP 콘택트렌즈의 시력과 각막에 미치는 임상적 연구)

  • Kim, Douk-Hoon;Bae, Han-Young;Han, Mung-Gyo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.55-69
    • /
    • 2007
  • The purpose of this study was to perform a clinical test using ez NANOsence II RGP contact lenses for the effects of visual acuity and cornea on subjects with abnormal refraction status. One hundred twenty one adults (twenty nine males, ninety two females, range = 17 to 43, mean = 22.86) were recorded. The subject's history including, the symptoms from previous lens wear, were studied. The subjects were observed, both pre and post lens wear, for any symptoms and signs of change of the eye. The Visual acuity and the binocular status were tested at the far distance using the contact lens. The refraction test was performed on the naked eye using the objective method (Topcon KR-8100, Japan). The Stereopsis test was performed at the near distance after contact lens wear by the Titmus fly (Stereo Optical Co., U.S.A) and TNO (TECH, The netherlands). The contrast sensitivity diagnosis was performed at 1m distance after contact lens wear by the contrast sensitivity chart (pelli-Robertson, USA). The corneal topography was analyzed on the naked eye after lens wear by ORB scan (Bausch Lomb, U.S.A.). The ultra structure of surface on the contact lens was observed using SEM (JMS-5800, Japan). The chemical component's of the contact lens was analyzed by EDS program. The results of this study were as follows: 1. The longer of contact lens wear period, The subjects have acquired the most improved visual function. 2. Subjects had experienced few side effects wearing the contact lenses. 3. The lenses were easy to use by the subjects. 4. The longer of contact lens wear period, the power of cornea had more decrease. but the base curve of cornea had more increase and corneal astigmatism was decrease (p<0.01). Also, the thickness of corneal center was few decrease. 5. Longer periods of using the contact lens showed stereopsis and contrast sensitivity at more normal values. 6 The corneal topographical after lens wear showed most subjects with similar morphology for different wear periods. 7. The surface ultrastructure of the new and used contact lens was the similar fine shape. 8. The chemical component's of in the new and used contact appeared to have similar results. In conclusion, this study showed that the surface ultrastructure and chemical component's of the new and used contact lens are similar. In addition, the subjects had improved the quality of vision and few experienced any side effects during long periods of contact lens wear. Also they have decrease of corneal astigmatism during the long period of lens wear. Our test has showed that the chemical composition and fine structure of contact lens have related to the visual function on contact lens wearer. In this paper, we suggested that ez NANOsence II RGP contact lenses had a moderate effect for correcting vision of abnormal refraction eye.

  • PDF

Changes in Objective and Subjective Responses in Soft Contact Lens Wearers Refitted to Daily-Wear Silicone Hydrogel Contact Lenses (매일착용 실리콘 하이드로겔렌즈로 바꿔 착용한 소프트 콘택트렌즈 착용자에서 나타난 증상 변화)

  • Lee, Koon-Ja;Mun, Mi-Young;Buyn, Jang-Won;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.4
    • /
    • pp.43-54
    • /
    • 2007
  • Silicone hydrogel contact lenses developed as a continuous-wear modality are now used as a daily-wear contact lenses. The purpose of this study was to investigate the clinical performance in a group of successful long-term wearers of conventional hydrogel contact lenses when refitted with daily wear $O_2OPTIX$ silicone hydrogel lenses. Sixty-two wearers ($30.7{\pm}19.9$ months of prior lens wear) among sixty-five soft lens wearers refitted with $O_2OPTIX$ silicone hydrogel lenses were participated in this study finally. Subjective symptoms were scored and objective signs were graded using CCLRU scales during the study period. 98% of subjects were successfully refitted with the one base curve of $O_2OPTIX$, and 33.9% of subjects were needed more or less lens powers compared with their habitual lenses. Subjects reported a concurrent reduction in dryness, redness and tiredness compared with their habitual lenses and both subjective and objective evaluations showed that dryness, tiredness, itchiness, bulbar and limbal hyperemia were decreased and significantly decreased particularly for those subjects with greater baseline symptoms (p<0.0001). But corneal staining was increased and was seen in many subjects during the study (p<0.0001). Refitting existing soft contact lens wearers with silicone hydrogel contact lens could result in a decreased in dryness, redness and tiredness, particularly more effective for those subjects with greater baseline of those symptoms. When patients using conventional hydrogel materials switch to a silicone hydrogel material, the potential for increased corneal staining should be considered and over-refraction should be needed to give a best vision.

  • PDF

A Study on the Funeral director's working Circumstances and Personal Protective Equipment on Funeral home (안치실 및 염습실 종사자의 주요 감염질병 조사 및 근무기간에 따른 개인위생용품 착용실태에 대한 연구)

  • Hwang, Kyu-Sung;Kim, Jeong-Lae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.3 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • We are investigated about the state of the working circumstances and infection blocking facility within Metropolitan, Chungcheong and Gyeongsang regions in Korea. The result is as follows. The HAV vaccination rate is 35% and the HBV vaccination rate is 50% among the funeral directors. We expected that the infection risk of funeral directors was very high. Significantly, tuberculosis prevalence rate of funeral director was four times as high as the public. The wear rate of gown, mask, gloves showed relatively high than the others. The wear rate of individual protective equipments has decreased with work experience. The funeral directors have shown that there is difficult to get safe protection from infection. The personal hygiene of funeral directors and the infection blocking equipment should be strengthened institutionally. We are thought to recommend institutional support about infection management, individual protective equipment, vaccination of funeral director and guideline to avoid reversion to previous habitual behavior.

The Comparative Analysis for the Progression of Dry Eyes Caused by Wearing Soft Contact Lenses(SCL) and Cosmetic Soft Contact Lenses(C-SCL) (소프트 콘택트렌즈와 미용 콘택트렌즈의 건성안 진행에 대한 비교분석)

  • Kim, Myoung-Jin;Hwang, Hye-Kyung;Jang, Woo-Yeong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.4
    • /
    • pp.375-381
    • /
    • 2011
  • Purpose: The purpose of this research was to see how wearing either a SCL or a C-SCL effected the dryness of a person's eye depending on how long they wear either type of lens. Methods: This study was carried out on 52 subjects (104 eyes) who were all in their twenties and had previously experienced wearing contact lenses. All of these subjects were required to wear either a SCL or a C-SCL, which were made out of the same material, for three months. Contents such as the McMonnies Questionnaire survey, the blinking rate per min. and the Noninvasive tear break-up time test (NIBUT) were later conducted on the subjects for this study. Results: According to the results of the McMonnies Questionnaire, it was concluded that the longer the subject wore the SCL and C-SCL, the value of the measurements gradually increased. On the other hand, the results from the NIBUT concluded that the longer the subject wore the SCL, the value of the measurements eventually decreased. However, according to the measurements of the blink rate test, it was concluded that neither results had a significant change. Conclusions: It was concluded that long-term wearing of SCL and C-SCL could be the cause of the induction and progression of dry eyes.

The Relationship between Habitual Patient-Reported Symptoms and Signs in the Soft Contact Lens Wearers (소프트 콘택트렌즈 착용자에서 평상시 나타난 증상에 관한 연구)

  • Lee, Koon-Ja;Buyn, Jang-Won;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.19-28
    • /
    • 2008
  • Purpose: To understand symptoms and signs in soft contact lens wearers the authors evaluate the attribution of the tear test to the contact lens related symptoms and signs. Methods: Sixty-two healthy soft contact lens wearers (23.95${\pm}$4.38 years old, 18.60${\pm}$16.92 months of prior lens wear) were participated in this study. 3 kinds of tear test and McMonnies' questionnaire test were performed for the soft contact lens wearers and subjective symptoms and objective signs were graded using CCLRU scales during the study period. Results: In this surveys, we found ocular dryness, redness and tiredness are the most common frequent and severe symptoms in soft contact lens wearers. Frequency of the ocular dryness, redness and tiredness are associated with grittiness, burning sensation and foreign body sensation respectively, and severity of the photophobia, foreign body sensation are associated with unstable vision and grittiness and which are associated with score of McMonnies' Questionnaire. Conjunctival redness and limbal redness are major signs but those are not need to be clinical care and rarely occurred corneal and conjunctival staining which are associated with tear break-up-time statistically. Conclusions: Dryness, redness and tiredness are primary common symptoms in Korean soft contact lens wearers. The frequency of those symptoms are increased with the period of soft contact lens wear and those are associated with other symptoms but have no relationship with signs.

  • PDF

Effect of Wearing a Compression Stocking on Electromyogram of the Legs (동일인에서 한쪽 다리에만 압박스타킹을 착용했을 때 유발되는 다리 근육의 근전도 변화에 대한 정량적 분석)

  • Lee, Ji-Youn;Yuk, So-Hee;Yoo, Hyo-Gyung;Hong, Nam-Ju;Jeon, In-Cheol;Jung, Dongju
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.2
    • /
    • pp.185-190
    • /
    • 2019
  • Compression stockings are widely used for prevention of varicose vein. Depending on manufacture, there are diverse types of compression stockings available. Most common type of compression stocking might be the one cover calf of a lower leg which has 20~30 mmHg pressure. Despite being widely used, possible side effects that may occur by wearing compression stockings have not been studied much. We analyzed for a long wearing effect of compression stocking. Participants wore the compression stocking over one leg for 7 days. During the period, all the participants did their ordinary works wearing the compression stocking. Electrocardiogram (ECG), ankle-brachial index (ABI), blood pressure (BP), and electromyogram (EMG) were measured at 0 day, 3rd day and 7th day. There was no effect of wearing compression stockings from ECG, ABI or BP. Only EMG that was measured on the covered muscle increased proportionally to the wearing time. Interestingly, EMG from the opposite leg that had never been covered by compression stocking decreased in proportion to the wearing date. These results suggest wearing a compression stocking for varicose vein may cause unintentional increase or decrease of EMG from the wearing or non-wearing legs, respectively.

Care Strategy of Sample-wearing Cosmetic Contact Lens for Preventing from Microbial Contamination (샘플착용 미용 콘택트렌즈의 세균 오염에 대한 관리방법)

  • Ko, Hoon;Kim, Eun Hye;Lee, Heum-Sook;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.1
    • /
    • pp.21-26
    • /
    • 2008
  • Purpose: To investigate the proper care system of sample-wearing cosmetic contact lens (SWCCL). Methods: Research on the actual condition about SWCCL was examined in fifty cosmetic contact lens wearer in their 10s and 20s by the questionnaire. Also, the extents of the contamination of gram-negative bacteria and fungi were measured in SWCCL after wearing for 2, 4 and 6 weeks, and it was investigated whether the proper care system could prevented the contamination. Results: As the result of the questionnaire, people purchased the cosmetic contact lens after trying SWCCL with a mean of 4.5. The contamination of gram-negative bacteria and fungi were significantly increased in SWCCL-wearing period-dependent manner. In both Group 1 (rubbing SWCCL and exchanging preserving solution every wearing of SWCCL) and Group 2 (only exchanging preserving solution every wearing of SWCCL without rubbing SWCCL), the contamination of gram-negative bacteria and fungi were prevented perfectly. In the case of Groups having every-week care, the proliferation of gram-negative bacteria and fungi were somewhat suppressed, and rubbing was helpful of decreasing the contamination. The biweekly care had scarcely any effect for preventing the contamination. Conclusions: By exchanging the preserving solution every wearing of SWCCL, the contamination of gram-negative bacteria and fungi could be suppressed perfectly.

  • PDF

A study to determine the ability to clinically adapt for wearers of the Pure Vision contact lens (Pure Vision Contact Lens 착용자에 대안 임상 적용 연구)

  • Kim, Douk-Hoon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.10 no.4
    • /
    • pp.411-417
    • /
    • 2005
  • The aim of this study was to investigate the ability for wearers in adapting to the Pure Vision contact lens. Methods: Subjects consisted of 78 university students who were analyzed by subjective and objective methods. During each day of use or extended wear, results relative to clinically adapt were analyzed over a period of one week. Results: 1. Visual function status Good 62.3%, Moderate 27.2%, Bad 10.6% 2. Side affects No sensation 76.12%, Moderate sensation 18.21%, Excessive sensation 6.5% 3. Lens handling ability Skillful 97.44%, Difficult 2.56% 4. Understanding Pure Vision lens characteristics 50.64% understood very well Conclusions: Most Pure Vision contant lens wearers had a good clinical response both subjectively and objectively but about one half did not understand fully the lens characteristics.

  • PDF

Effect on Myopia Progression Wearing Eye-glasses for School Children (학령기 아동의 안경착용이 근시진행에 미치는 영향)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.195-200
    • /
    • 2011
  • Purpose: We analyzed the influence of myopic's eye-glasses wearing on myopia progress after cycloplegic refraction. Methods: The 33 people (66 eyes) were school children from 8 years to 12 years having no experience eye-glasses wearing, they were taken cycloplegic refraction at the 100th, the 200th and 300th days in order to evaluate myopia progression. We investigated the eye-glasses wearing group (experimental group, 32 eyes) and the non-eye-glasses wearing group (control group, 34 eyes). The eye-glasses power of the experimental group were -0.50 D, -0.75 D, -1.00 D, -1.25 D and -1.50 D. We compared experimental group with control group for myopia progress according to period, age, and refraction error and investigated the myopia progress according to the eye-glasses power of experimental group. Results: At the 300th day from the first cycloplegic refaction, spherical equivalent for the experimental group increased as -1.03${\pm}$0.43 D (t=13.36, p<0.001) and for the control group increase as -0.61${\pm}$0.35 D (t=10.05, p<0.001) and two groups were statistical difference. Myopia power for experimental group increased 60.75%, for control group increased 56.66% at the 300 days. According to eye-glasses power increased 41.19${\pm}$15.25% at -1.50 D, 36.74${\pm}$19.29% at -1.25 D, 56.57${\pm}$20.21% at -1.00 D, 87.26${\pm}$49.38% at -0.75 D and 106.69${\pm}$59.60% at -0.50 D. Conclusions: The myopia power for the eye-glasses wearing group was 0.46 D faster than the non-eye-glasses wearing group at the 300th day from the first cycloplegic refraction. We will consider the effect of non-eye-glasses wearing to protect the progressing myopia and prescribe the under correction for school children having no experience eye-glasses wearing.