• Title/Summary/Keyword: 착용형

Search Result 472, Processing Time 0.027 seconds

Development of Wearable Sensing and Feedback Product Design for Movement Monitoring (동작 모니터링을 위한 웨어러블 센싱 및 피드백 제품 디자인 개발)

  • Cho, Hyun-Seung;Yang, Jin-Hee;Lee, Kang-Hwi;Lee, Jeong-Hwan;Park, Su-Youn;Choi, Hyeong-Ik;Jeon, Hak-Su;Lee, Joo-Hyeon
    • Science of Emotion and Sensibility
    • /
    • v.21 no.3
    • /
    • pp.165-176
    • /
    • 2018
  • The objective of this study was to develop clothing-type wearable motion sensing and feedback systems to enhance children's sports by promoting visual and audio feedback. In this study, several applications, such as fabric sensors, sportswear integrated with various types of fabric sensors, and fabric-based motion sensing module design, as well as a visual and audio feedback system for gaining a better understanding of a child's interest in a type of exercise, were developed. An SWCNT-based stretchable fabric sensor was developed for motion sensing, and sportswear was designed using the fabric sensor that was integrated into the limbs of the garment. The sensing module was developed, and sensory performance was evaluated through a joint motion experiment for children. In addition, using the feedback system that was developed in the form of an accessory, the responses of light and sound were also examined based on the movement of the child who was wearing the sportswear prototypes. This study focused on the development and assessment of prototype designs for children's sportswear and accessory products that can help to ascertain a child's interest in a particular exercise.

Investigation of Microbial Contamination in Liriope platyphylla at Post Harvest Environments (맥문동(Liriope platyphylla) 수확 후 처리 환경의 위생지표세균 및 병원성 미생물 오염도 조사)

  • Kim, Yeon Rok;Ha, Ji-Hyoung;Kim, Se-Ri;Park, Young Chun;Kim, Kyeong Cheol;Kim, Won-Il;Ryu, Song Hee;Kim, Hwang-Yong
    • Journal of Food Hygiene and Safety
    • /
    • v.31 no.2
    • /
    • pp.99-106
    • /
    • 2016
  • This study was aimed to assess microbiological contamination level of Liriope platyphylla farms (A, B, and C) located in Cheongyang, Chungnam province. Specimens sampled from those farms and L. platyphylla tuberous roots were assessed for sanitary indication bacteria such as total aerobic bacteria, coliforms, and Escherichia coli and pathogenic bacteria such as Escherichia coli O157:H7, Listeria monocytogenes, Salmonella spp., Staphylococcus aureus and Bacillus cereus, quantitatively and qualitatively. As a result, those farms are not contaminated by E. coli O157:H7, L. monocytogenes, Salmonella spp., at all. And S. aureus was only found qualitatively from workers' gloves at a farm. As a whole, those farms (soil, harvest container, harvester, cleanser, washing water and tray) were maintained in a low level of microbiological contamination. However a cleanser was contaminated by coliforms ($4.35log\;CFU/100cm^2$), and it is required to improve farm hygiene. Microbiological contamination level of L. platyphylla tuberous root was decreased in the postharvest process including washing and drying.

Model on the Capillary Action-Induced Dynamics of Contact Lens (모세관 작용에 의한 콘택트 렌즈의 운동 모델)

  • Kim, Dae-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.2
    • /
    • pp.85-97
    • /
    • 2001
  • A mathematical model was proposed to analyze the damped motion of contact lens which is initially displaced from the equilibrium position. The model incorporates the differential equations and their numerical solution program, based on the formulations of restoring force arising from the capillary action in the tear-film layer between the lens and cornea. The model predicts the capillary action induced surface tension, time dependence of displacement of lens when it is released from the equilibrium position. It seems that the motion of lens is similar to the typical over-damped oscillation caused by the large viscous friction in the liquid layer between the cornea and lens. The effect of variables such as base curves, lens diameters and thickness of tear film layer were illustrated by the computer simulation of the derived program. The time required for the lens to return to the original position increases as the liquid layer thickness increases and it decreases as the diameter of lens increases. With the certain value of base curve the time interval is found to be minimum. The free vibrations of lenses were also simulated varying the parameters such as base curve, diameter, layer thickness. The resonant frequencies are inversely proportional to the liquid layer thickness and it increases as the lens diameter increases. The resonant frequency of lens has a maximum when the diameter is of certain value. If the external impulse or force of the same frequency as the natural frequency of contact lens acted on the cornea in vivo it may cause an excessive movement and thus it might cause the distortion 10 the lens or be pulled off the eye.

  • PDF

The Effects of Wearing Roller Shoes on Muscle Activity in The Lower Extremity During Walking (롤러신발과 일반신발의 착용 후 보행 시 하지근의 근전도 비교)

  • Chae, Woen-Sik;Lim, Young-Tae;Lee, Min-Hyung;Kim, Jung-Ja;Kim, Youn-Joung;Jang, Jae-Ik;Park, Woen-Kyoon;Jin, Jae-Hong
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.137-148
    • /
    • 2006
  • The purpose of this study was to compare muscle activity in the lower extremity during walking wearing jogging and roller shoes. Twelve male middle school students (age: 15.0 yrs, height 173.7 cm, weight 587.7 N) who have no known musculoskeletal disorders were recruited as the subjects. Seven pairs of surface electrodes (QEMG8, Laxtha Korea, gain = 1,000, input impedance >$1012{\Omega}$, CMMR >100 dB) were attached to the right-hand side of the body to monitor the rectus femoris (RF), vastus medialis (VM), vastus lateralis (VL), biceps femoris (BF), tibialis anterior (TA), and medial (GM) and lateral gastrocnemius (GL) while subjects walked wearing roller and jogging shoes in random order at a speed of 1.1 m/s. An event sync unit with a bright LED light was used to synchronize the video and EMG recordings. EMG data were filtered using a 10 Hz to 350 Hz Butterworth band-passdigital filter and further normalized to the respective maximum voluntary isometric contraction EMG levels. For each trial being analyzed, five critical instants and four phases were identified from the recording. Averaged IEMG and peak IEMG were determined for each trial. For each dependent variable, paired t-test was performed to test if significant difference existed between shoe conditions (p<.05). The VM, TA, BF, and GM activities during the initial double limb stance and the initial single limb stance reduced significantly when going from jogging shoe to roller shoe condition. The decrease in EMG levels in those muscles indicated that the subjects locked the ankle and knee joints in an awkward fashion to compensate for the imbalance. Muscle activity in the GM for the roller shoe condition was significantly greater than the corresponding value for the jogging shoe condition during the terminal double limb stance and the terminal single limb stance. Because the subjects tried to keep their upper body weight in front of the hip to prevent falling backward, the GM activity for the roller shoe condition increased. It seems that there are differences in muscle activity between roller shoe and jogging shoe conditions. The differences in EMG pattern may be caused primarily by the altered position of ankle, knee, and center of mass throughout the walking cycle. Future studies should examine joint kinematics during walking with roller shoes.

A Study on Apparatus of Human Body Antenna for Mine Detection (지뢰탐지용 휴먼바디 안테나 장치 연구)

  • Kim, Chi-Wook;Koo, Kyong-Wan;Cha, Jae-Sang
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.269-272
    • /
    • 2015
  • this is the study of the human body antenna device which can detect the powder in a 360-degree on(under) the ground whether it is metal or nonmetal using superhigh frequency RF beam equipped with the body. and it is able to transmit the data of the detection of the powder, battle combats can share that among them. with its flexible roof radial antenna structure, it emits the superhigh frequency RF beam to the front and flank multiply, preprocesses through the powder preprocessing part. and with the non-linear regression model algorism engine part, reflecting the attenuation characteristics depend on the delayed time of degree of the signal power which is received to the superhigh frequency RF beam. so it is able to detect the signal of the most likely mine or powder based on the degree of the answer signal power according to the delayed time of the superhigh frequency RF beam. also, it can detect the powder whether it is metal or nonmetal, mine, dud, VBIED. it can increase the chance of detection about 90% more than existing mine detector.

A Study on Pattern Grading of Eco Resort wear for Jeju Medical Tourism (제주 의료관광을 위한 에코 휴양복의 패턴그레이딩 연구)

  • Choi, Gun-Han;Kang, In-Hee;Yang, Hye-Jin;Lee, Mi-Na;Lee, Eun-Joo;Ko, Ju-Hyung;Hong, Ji-Un;Kwon, Sook-Hee
    • Science of Emotion and Sensibility
    • /
    • v.13 no.4
    • /
    • pp.733-740
    • /
    • 2010
  • This proposal of eco-friendly Resort wear targeting medical tourists of Jeju intend to contribute to the local economy by creating more added-values and profits. With high-quality leisure outfits, the medical tourism could provide tourists more pleasantness as well as a souvenior, which may help them to cherish the memory in Jeju. Well-developed Galot leisure outfits matched with other Galot products could result in additionary buying of other Galot items. Furthermore, by developing the size system as well as pattern grading, we can help local Galot manufacturers who currently require these standardized creation system. The summary of this research is as follows: 1. we examined the current issues and disadvantages of the local Galot through a survey. 2. We defined the Galot leisure outfit for Jeju medical tourism, conducted market research, and reflected these into representative designs for them. 3. We developed a size system as well as a pattern grading to standardize the manufacturing process.

  • PDF

Analysis of Optimum Design of Stepped Bar Horn for 20kHz Metal Ultrasonic Welding (20kHz 급 금속 초음파 융착용 스텝형 바 혼의 최적설계)

  • Kim, Jisun;Kim, Jaewoong;Kim, In-ju;Seo, Joowhan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.94-101
    • /
    • 2019
  • In this study, the FEM technique was applied to design the shape of the horn that transmits ultrasonic vibration energy to the base material, and the shape of the welding horn with a one-wavelength bar shape used in the 20kHz region was designed. The shape design of the horn was performed by applying the rod longitudinal vibration theory to Ansys APDL (Ansys Parametric Design Language). Twenty-five models were designed using the ratio of the area of the input and output surfaces of the vibration and the length of the horn to derive the appropriate horn shape. The horn was designed with a total length of 130mm, a step length of 65mm, and an output area of 28.79mm. The horn was fabricated using the optimized dimensions, and the vibration and displacement characteristics of the horn were evaluated using the measurement system. Finally, a uniform longitudinal step horn was designed, and more than 97.4% of the uniformity of the tip was secured. The amplitude ratio of the optimized horn was improved by 51%.

COMPARISON OF SHEAR BOND STRENGTH AND MARGINAL LEAKAGE OF RESIN MODIFIED GLASS IONOMER CEMENTS (강화형 글라스 아이오노머 합착용 시멘트의 접합강도 및 변연누출에 대한 연구)

  • Park, Hye-Yang;Oh, Nam-Sik;Lee, Keun-Woo;Lee, Ho-Yong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.35 no.4
    • /
    • pp.647-661
    • /
    • 1997
  • The resin modified glass ionomer cements(RMGICs) have been used for years since 1989. Recently it has been developed for luting of fixed restorations. To evaluate the bond strength and marginal leakage of RMGICs for luting usage, the 80 extracted human molars which had uniform area of exposed dentin were cemented with 3 types of RMGICs(Fuji Duet, Advance, Vitremer), a conventional Glass Ionomer Cement(GIC-Fuji I), and a resin cement (Panavia 21) to base metal alloy(Ni-Cr-Be). After thermocycling the specimens were immersed in basic fuschin dye for measuring marginal leakage. The shear bond strength was measured with Instron and the maximum dye penetration was measured to 0.1mm. The types of fractured patterns were determined with stereoscope(${\times}7.5$). The results are as follows. 1. The difference between 3 RMGICs and a conventional GIC in shear bond strength was not statistically significant. It seemed that RMGICs had lower shear bond strength than resin cement. (p<0.01) 2. The mean scores of marginal leakage had no significant difference between the resin cement and 3 RMGICs but it was much higher in conventional GIC than the RMGICs (p<0.05) 3. It was determined that the manufacturer and the methods of dentin pretreatment determined the pattern of fracture surfaces and the frequency of adhesive failure between teeth and 3 RMGICs standed as in following order - Vitremer, Advance, Fuji Duet. (p<0. 01) When the fracture pattern was analyzed, it could be said that the materials and the method of dentin pretreatment have much effect on bonding states. This means that the dentin bonding agents should be improved. But the limited products in this experiment can not evaluate the physical properties of the entire RMGICs. Therefore a further study which can evaluate various RMGICs should be in progress to develope better cements.

  • PDF

A study on wearing practice and improvement of personal protective equipment for participant handling livestock carcass infected with virulent avian infectious agents (가금류 악성 전염병 감염축 처리자의 보호 장비 착용실태 조사 및 개선에 관한 연구)

  • Lee, Hyeyeoun;Lim, Ui-Hyoung;Kim, Jong Won;Kim, Won-Il;Kang, A-Rum;Lim, Chae Woong;Hong, Chul Un;Han, Jihyeon;Kang, Seog-Jin;Kim, Bumseok
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.4
    • /
    • pp.241-248
    • /
    • 2015
  • This study was aimed to investigate factors that affected the status of wearing personal protective equipment (PPE) for handling poultry carcasses with potential exposure to virulent avian infectious agents. A large outbreak of high pathogenic avian influenza (HPAI) occurred in South Korea in 2014. Many public officers participated for euthanizing and handling livestock carcass. However, several safety issues with using PPE were revealed. Therefore, a questionnaire survey was conducted for 340 people who participated euthanasia and carcass disposal in the place where HPAI mainly occurred in 2014. It was found that 31.8% of the respondents had ever taken off their protective equipment during operations because of its inconvenience. The most inconvenient PPE was goggles (54.6%), followed by mask (20.2%), latex gloves (11.6%), shoe covers (5.9%) and protective clothing (5.3%). The main complaints about this individual PPE was unclear sight, damp emitted toward eye, sweating, tearing easily and sweating, respectively. Considering such problems of PPE, new possible directions for improvement of gloves and goggles were suggested. With newly developed rubber coating fabric gloves and conventionally using latex and fabric gloves, H3N2 influenza virus transmission experiment was conducted. Rubber coating fabric gloves showed similar efficiency for blocking virus transmission with latex laboratory gloves and were not easily torn by sharp claws of chicken. In addition, air flow control safety eyewear was suggested to minimize moisture formation. The air flow control system efficiently suppressed moisture formation inside the goggles. Therefore our study will provide more specific directions about new PPE development for safety protection of actual wearers.

Development of the Pushing Type Cutting Device to Dismantle Concrete Structure for Decommissioning of Nuclear Power Plant (원전해체 시 콘크리트 구조물 절단을 위한 밀기형 절단장치 개발)

  • Lee, Bong-Jae;Kwon, Yong-Kyu;Hong, Chang-Dong;Lee, Dong-Won;Min, Kyong-Nam
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.1
    • /
    • pp.103-111
    • /
    • 2020
  • Pulling-type cutting devices, which use a diamond wire saw, have been used generally for cutting concrete structures. In this study, a pushing-type cutting device with a collection cover was developed by overcoming the disadvantages of pulling-type devices. In this device, dry or liquid methods can be selected to cool frictional heat. Operation and leakage tests of the dust generated during the dismantling of a concrete structure were carried out, confirming the suitable operation of the fabricated cutting device; the leakage rate was approximately 1.7%. For a conservative evaluation, the internal dose of workers was estimated in dismantling the core center part of biological shield concrete with a specific activity of 99.5 Bq·g-1. The committed effective dose per worker was 0.25 mSv. The developed cutting device contributed to reducing radioactive concrete waste and minimizing worker exposure due to its easy installation. Therefore, it can be utilized as a cutting apparatus for dismantling not only reinforced concrete structures but also radioactive biological shield concrete in nuclear power plant decommissioning efforts.