• Title/Summary/Keyword: 착용비교

Search Result 460, Processing Time 0.023 seconds

The Effect of Occlusal Condition on Physical Fitness and Motor Capacity in Athletes According to Various Types of Mouthguards (마우스가드의 형태가 운동선수의 체력 및 운동능력에 미치는 영향)

  • Choi, Su-Jeong;Jung, Jae-Kwang;Lee, Kyu-Bok;Chae, Woen-Sik
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.1
    • /
    • pp.1-9
    • /
    • 2013
  • This study examined the effects of the occlusal stability and a partial coverage mouthguard on physical fitness and motor capacity to determine the importance of the occlusal stability as a possible action mechanism of mouthguards on physical performance. Twenty physical education students were included for measurements of their handgrip strength, back strength, whole body reaction time, flexibility, sidestep test, stork stand test and jumping test according to the following 5 different occlusal conditions: mouth closed position without a mouthguard, with a full coverage mouthguard, with a right partial coverage mouthguard, with a left partial coverage mouthguard and with anterior partial mouthguard. The results revealed no significant difference in any of the measured physical factors between the occlusal conditions with and without a full-coverage mouthguard. On the other hand, a significant difference was observed in whole body reaction between the occlusal conditions with and without the partial coverage mouthguards. Therefore, isokinetic muscle tests on both knee joints and the Wingate anaerobic power test should be performed under the following five occlusal conditions: with or without full-coverage maxillary custom-made mouthguard, with a unilateral right or left partial-coverage maxillary mouthguard and with an anterior partial-coverage maxillary mouthguard. These results suggest that the partial coverage mouthguard had a short-term beneficial effect on agility rather than full coverage mouthguard.

Use of Piggyback Contact Lens System to GP Lens Wearers (GP렌즈 착용자에게 피기백 콘택트렌즈 시스템의 적용)

  • Kim, Yong Gil;Kim, Soo Hyun;Kim, Jai Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.47-53
    • /
    • 2010
  • Purpose: This study was performed to achieve an acceptable piggyback fit utilizing each subject's own GP lenses, in subjects with regular low myopic astigmatism. Methods: A randomized, prospective study of 15 subjects with the diagnosis of low myopic astigmatism was conducted. Nine subjects were female and 6 were male, and mean age was: 23.73${\pm}$1.68 years. Subjects were evaluated before participate on this study and then also evaluated with period of at two hours and two weeks after obtaining their lenses. All subjects were submitted to the following tests: measurement of comfort level by means of the analogical visual scale, best corrected visual acuity and over-refraction at distance. contrast sensitivity and stereo acuity. After evaluating the fit of plano soft lens, we applied each subject's own GP lens on top. Results: Vision, visual performance and satisfaction of piggyback contact lens system were stable, if not improved, for the 15 subjects when the data was compared to the patients' wear of rigid gas permeable contact lenses. Fit with a piggyback system had the same or improved comfort, visual acuity and contrast sensitivity compared to previous GP lens wear alone. The visual acuity, contrast sensitivity and stereo acuity did not show differences in relation to the studied lens type. Conclusions: These results suggest that it is possible to achieve a successful piggyback lens fitting utilizing a patient's own GP lens. The piggyback lens system satisfied the visual performance and visual requirements of this subject with GP lens alone for the correction of low myopic astigmatism.

Analysis of Adaptation for The first-time Progressive Lenses Glasses Wearers (누진렌즈 안경 처음 착용자의 적응도 분석)

  • Shim, Jun-Beom;Shim, Hyun-Seog
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.117-122
    • /
    • 2011
  • Purpose: This study analyzed the factors related to adaptation of people who wears progressive lenses glasses for the first time. Methods: 463 presbyopia (Aged 41~78) without any ocular diseases with the progressive lens glasses were prescribed from 2010 to 2011 at B clinic in the Gwangju city. Progressive lenses adaptation were analyzed according to gender, age, distance refractive state, presbyopic addition, progressive lens design, the old glasses, astigmatism type, and anisometropia etc. High, mid and low-adapted groups were categorized as the status of wearing progressive lenses glasses, re-wearing, occasionally wearing and failed to weraing, respectively. Results: Men showed significantly higher adaptation (p=0.02) than women. Presbyopic addition (p=0.05) and progressive lens design (p=0.02) were statistically significant. However, it was found that there was so statistical significance for the factors of age, distance refractive state, the old glasses, astigmatism type, and anisometropia. Conclusions: According to the results of this study, when progressive lenses were prescribed, we should consider for adaptation gender, presbyopic addition, and progressive lens design etc.

3D Reconstruction of a Single Clothing Image and Its Application to Image-based Virtual Try-On (의상 이미지의 3차원 의상 복원 방법과 가상착용 응용)

  • Ahn, Heejune;Minar, Matiur Rahman
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.25 no.5
    • /
    • pp.1-11
    • /
    • 2020
  • Image-based virtual try-on (VTON) is becoming popular for online apparel shopping, mainly because of not requiring 3D information for try-on clothes and target humans. However, existing 2D algorithms, even when utilizing advanced non-rigid deformation algorithms, cannot handle large spatial transformations for complex target human poses. In this study, we propose a 3D clothing reconstruction method using a 3D human body model. The resulting 3D models of try-on clothes can be more easily deformed when applied to rest posed standard human models. Then, the poses and shapes of 3D clothing models can be transferred to the target human models estimated from 2D images. Finally, the deformed clothing models can be rendered and blended with target human representations. Experimental results with the VITON dataset used in the previous works show that the shapes of reconstructed clothing are significantly more natural, compared to the 2D image-based deformation results when human poses and shapes are estimated accurately.

Convergence of Comparison of Muscle Activities of Healthy Adults' trunk and Lower Extremities according to wearing/not-wearing and forms of backpack (백팩 착용 유무 및 형태에 따른 건강한 성인의 몸통과 하지의 근 활성도 비교분석의 융합연구)

  • Kim, Kyung-Hun;Jang, Sang-Hun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.11
    • /
    • pp.225-232
    • /
    • 2019
  • This study aims to compare muscle activities of trunk and lower extremities according to wearing/not-wearing and forms of backpack. Twenti-six healthy adults were participated in the study. In the backpack with 10% body weight, trunk and lower extremities were measured during carrying the no backpack state(NBs), general backpack state(GBs), a decrease moment arm backpack state(DMBs). The muscle activity in a fore muscles(Obilique, Quadriceps, Tibialis anterior, Gastrocnemius) were analyzed with using wireless electromyogram measuring system. DMBs showed significant improvemet in obilique, quadriceps and gastrocnemius muscle RVC.

Changes in Subjective/Objective Symptoms and the Light Transmissibility of Lens Associated with Overusage of Daily Disposable Circle Contact Lenses in Normal Eyes (일회용 써클소프트렌즈의 초과 착용에 의한 정상안의 자·타각적 증상 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kwon, Hae Lim;Choi, Sae Ah;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.18 no.4
    • /
    • pp.429-439
    • /
    • 2013
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmissibility of lens caused by over-usage of daily disposable circle contact lenses (circle lens). Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 20 normal eyes free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, non-invasive break-up time, lens centration on corneal surface and visible light transmissibility of lens were recorded at every case and compared. Results: The circle lens wearers complained discomfort when they wore the circle lens more than 15 hours, in excess of 8 hours being the recommended wearing time and the most circle lens wearers quit the lens wearing when they wore more than 30 hours. On the last day of lens wearing, the representative subjective discomforts were stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, a tendency of increased blinking rate and decreased NIBUT was observed when it compared with the values right after lens wearing. On the last day of lens wearing, the lens centration was shown to be decentrated from the pupil center compared with the centration right after the wearing. These changes in lens centration and blinking rate were consistently shown in all cases of lens wearing however, the difference in the degree of subjective and/or objective change was present depending on lens materials and subjects. The visible light transmissibility of circle lens has largely been changed. Conclusions: From these results, it was thought that the decreased NIBUT induced dryness and stiffness and decreased visible light transmissibility caused more blinking when daily disposable circle lens was exceedingly used, which provoked lens decentration and subjective discomfort. However, the difference of subjective and/or objective change was largely varied in accordance with the lens material types and individuality and thus it may occur some unexpected problems by the individual base. Therefore, the education about the necessity to comply with the recommended wearing time and the problem will be essential.

The Change of Blink Rate by Wearing Soft Contact Lens (소프트콘택트렌즈 착용에 의한 순목 횟수 변화)

  • Lee, Youn-Jin;Park, Sang-Il;Lee, Heum-Sook;Park, Mi-Jung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.3
    • /
    • pp.173-179
    • /
    • 2006
  • We investigated the change of the blink rate by wearing soft contact lens(SCL). Eight types of soft contact lenses were worn by twelve asymptomatic contact lens wearers. When wearers were worn SCLs for 15 min, the average blink rate was 20.0 blinks/min, which was a statistically significant increase compared to 13.3 blinks/min, the average blink rate of non-SCL-worn eye. After 8 hr of lens wear, the average blink rate was 24.3 blinks/min, and it was 11 blinks/min more than that of non-SCL-worn eye and 4 blinks/min more than that of 15 min SCL-worn eye. There were a little difference of the blink rate in types of lens, which the blink rate range of all lens after 15 min of lens wear was 18.1~20.9 blinks/min and that after 8 hr of lens wear was 22.9~24.9 blinks/min. When wearing A lens(vifilcon, 0.06 mm) having thin center thickness, wearers showing difference of 10.0~11.9 blinks/min between non-SCL-worn eye and 15 min SCL-worn eye reached 16.7% and it was more than that of relatively thick B lens(0.17 mm) and C lens(0.14 mm). This result suggest that the center thickness was not unique factor of the blink rate change and other factors would have synthetically influence on the blink rate change. In the case of B lens and C lens of hilafilcon material but having different center thickness and water content, wearers increasing more than 4.0 blinks/min after 8 hr of lens wear was 58.3% and 41.7%, respectively. This result have provided information that the lenses of similar materials but different center thickness and water content could cause individually the different change of the blink rate.

  • PDF

Comparison and Analysis for the Effects of Functional Progressive Addition Lenses on Binocular Vision of University Students (기능성 누진가입도렌즈가 대학생들의 양안시기능에 미치는 영향 비교 분석)

  • Kim, Chang Jin;Kim, Hyun Jung;Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.105-116
    • /
    • 2010
  • Purpose: To analyze and compare differences between single vision lenses and functional progressive addition lenses and improvement to binocular visual function wearing functional lenses for pre-presbyopes altered their single vision lenses to functional progressive addition lenses with low addition. Methods: Healthy 32 subjects aged 24.03${\pm}$1.87 (male 23, female 9) who were recruited from university students wore functional progressive addition lenses (EYE-T, Chemilens Co., Korea, ADD 0.750) for 2 months. Objective refraction, corrected visual acuity at distance and near, near point of convergence, near point of accommodation, accommodative facility, phoria at distance and near were measured. And subjective satisfaction was investigated by using a questionnaire designed to fatigue, comfort, discomfort, overall satisfaction and preference. Results: Functional progressive addition lenses were better than single vision lenses at near point of convergence and accommodation, accommodative facility. Exo phoria measured at distance with single vision and functional progressive addition lenses. Exo phoria measured at near with functional progressive addition lenses was higher than that with single vision lenses. As a survey, the satisfaction was increased in questions related near work. However, single vision lenses were preferred in distance test of overall satisfaction, easy 10 adapt, lime to adapt. A survey showed thai preference of functional progressive addition lenses were increased 75.00% to 81.26% for near work, 50.00% to 65.63% for visual fatigue, 47.75% to 50.00% for visual comfort and 31.25% to 46.88% for overall comfort. Conclusions: Comparing between single vision lenses and functional progressive addition lenses, binocular visual function related near work, subjective satisfaction and preference was improved after wearing functional progressive addition lenses. This study suggested that functional progressive addition lenses were useful for long time near work.

Effects of Wearing Corrective Glasses for Presbyopia on Age-related Hyperopic Shifts and Reading Addition (노안보정용 안경 착용이 연령관련 원시화와 근용가입도 변화에 미치는 영향)

  • Lee, Koon-Ja;Kim, Jin-Han;Mun, Mi-Young;Leem, Hyun-Sung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.3
    • /
    • pp.65-73
    • /
    • 2009
  • Purpose: This study was conducted to investigate the changes in distance refractive power and reading addition that occur after wearing corrective glasses for prebyopia. Methods: The subjects aged 42 to 75 years who had no ophthalmologic diseases and did not undergo cataract or retina surgery, had a corrected visual acuity of 20/20 and did not have a previous history of wearing corrective glasses for presbyopia. These subjects were divided into 3 groups: the control, reading spectacles and multifocals wearing group and they were measured for distance refractive power and reading addition at their visit. The maximum follow-up period was 73 months. Results: As for distance refractive power, the power tends to shift to hyperopia depending on age (r=0.486, p<.001) and 50.0% of the subjects increased plus power during this study period. Plus power Increments per year in distance refractive power in the reading spectacle wearing group were significantly different with control and multifocals wearing group (p<.05). On the other hand, the multifocals wearing group's increments were not different with control. Increments in reading addition were also increased in the reading spectacles group than in the control and multifocals wearing groups (p<.05). Conclusions: The age related hyperopic shift could be occurred in the elderly people, routine refraction is mandatory. And reading spectacles could induce an age related hyperopic shift and the additional need for reading addition that the prescription of multifocals may reduce changes in distance refractive power and reading addition.

  • PDF

The Effect of Circle Lens and Soft Contact Lens with Identical Material in Clinical Application on the Eyes (써클 및 동일 재질 콘택트렌즈의 임상 적용시 눈에 미치는 영향)

  • Park, Sang Hee;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.16 no.2
    • /
    • pp.147-157
    • /
    • 2011
  • Purpose: The present study was conducted to investigate the actual condition of circle lens wear and the differences caused by the pigmentation in blinking rate, non-invasive tear break-up time (NIBUT), and lens surface between circle and soft contact lens wear during clinical application. Methods: Eighty subjects were surveyed to know the actual condition of wearing circle lens. Blink rate, NIBUT of 20 subjects in twenties were measured after separately wearing soft contact lens and circle lens for 5 days. Their lens surfaces were also observed by scanning electron microscope. Results: Fifty percent of circle lens wearers answered that major reason for changing circle lens was discomfort and 67% of answerers wore circle lens more than 6 hours a day. The tendency of increased blink rates in both wearers of circle and soft contact lens at 30 minutes later when tear film stabilized and 3 hour after lens wearing was shown on the 1st, 3rd and 5th day with expanding wearing time. Especially at 3 hours after lens wearing on the 3rd and 5th day, the difference of blink rates was statistically different in circle lens wear and soft contact lens wear. The NIBUTs of soft contact lens wearers and circle lens wearers were 6.0 and 3.7 secs, respectively, at 30 min later on 1st day and were significantly different. NIBUTs of soft contact lens wearers and circle lens wearers were also statistically different 3 hrs after lens wearing on the 1st day and the similar pattern of NIBUTs was shown on the 3rd and 5th day. The roughness of both surfaces in soft contact lens and front surface in circle lens was same. However, pigmented front surface of circle lens was rougher and uneven. Conclusions: As the results, the circle lens wearers might feel discomfort in clinical application since the difference in lens surface of circle lens would change lens wettability during wearing. The difference by tinting contact lens was shown from the result, which could help better wearing circle lens.