• Title/Summary/Keyword: 차폐물질

Search Result 177, Processing Time 0.024 seconds

The Development of a Multi-Purpose Irradiator and the Characteristic of Dose Distribution (다목적 방사선 조사장치 개발 및 선량분포특성)

  • Lee, Dong-Hoon;Ji, Young-Hoon;Lee, Dong-Han;Kim, Yoon-Jong;Hong, Seung-Hong
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.42-48
    • /
    • 2002
  • The design, construction and performance test of a convenient multi-purpose irradiator is described. A multi-purpose irradiator using Cesium-137 has been developed for studies of low dose radiation effects in biology and for calibration of Thermo Luminescent dosimeter(TLD). During the operation, three rods of radioactive material which are 10cm in length revolve 180 degrees and irradiate biological samples, or TLD, and return to their shielded position, after the programmed time. A programmable Logic Controller(PLC) controls the sequence of operation, interlock, motor rotation and safety system. The rotation speed of biological samples can vary up to 20 RPM. A real time monitoring system was also incorporated to check and control the operation status of the irradiator. The capacity of the irradiation chamber was 4.5 liters. The isodose distribution at arbitrary vertical planes was measured by using film dosimetry. The dose-rate was 0.13 cGy/min in air and 0.11 cGy/min in water equivalent material in the case of Cesium-137. Range of activity was 2 Ci. The homogeneity of dose distribution in the chamber was ${\pm}$7%. The actual radiation level on the surface was within permissible levels. The irradiator had a maximum 0.35 mR/min radiation leakage on its surface.

Development of Real-time Groundwater Quality Monitoring and Advanced Groundwater Purification Technology for Groundwater using Photoinduced Reactive Oxygen Species (지하수 수질 실시간 모니터링 및 광유도 활성산소를 이용한 고도수처리 기술)

  • Kang-Kyun Wang;Byung-Woo Kim
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2023.05a
    • /
    • pp.15-15
    • /
    • 2023
  • 2020년 기준 국내 상수도 보급률은 99.1% 차지하고 있으며(환경부, 2019), 수도관리차원에서 수돗물은 먹는 물로 시판되어질 만큼 우수한 관리체계를 유지하고 있다. 그 반면에 지하수는 생활용수, 식품가공, 농·축산, 양어, 군부대를 비롯한 전국지역에서 연간 10억 8천만톤 용수를 소비하고 있음에도 (환겨례 신문, 2013; 환경부, 2019) 사용되는 지하수의 약 65%가 음용수 불가판정을 받았으며, 최근 지하수의 오염비율은 급격히 증가하는 추세이다. 특히, 지하수관정의 관리부주의에 의한 수질오염 및 수인성 다제내성균(슈퍼박테리아) 등에 의한 오염사례가 국내는 물론, 국제적으로 다수 보고되고 있는 실정이다 (환경부, 2013). 현재 지하수 수질관리는 공공기관 및 지자체 지정기관을 통해 진행되고 있으며, 검사기간은 수질채취로부터 통상 7~15일정도 소요되어 수질 관리 및 기준, 검사주기에 대한 애로가 많다. 현장 지하수관정에서 실시간 수질을 모니터링하고 이에 연동된 자동 수처리 시스템의 개발 및 도입은 나날이 심각해지는 환경오염 상황에서 선제적 예방과 해결방법으로 중요한 요소기술이다. 현재 지하수오염 및 부적합 음용의 수질처리는 화학약품, 필터여과, UV살균, O3 (플라즈마)을 이용하는 것이 대표적이나, 화학약품의 경우 2차 오염이나 식품 세척 및 가공에 있어 부적합성의 한계점이 있다. 필터여과의 대표적인 RO필터의 경우 약 50% 순손실이 발생하고, UV 살균의 경우 UV에 의한 사용관리자의 위험 및 장비의 광부식 문제, O3 의 경우 고압전류 사용에 따른 위험성 등의 한계점이 나타나고 있다. 지하수 수질정화를 위한 광유도 활성산소(1O2, ·O-2)는 광감응제에 가시광의 빛 조사를 통해 생성되는 활성산소로의 에너지 및 전자 전이가 동시 진행되어 단일항 산소(1O2)와 슈퍼옥사이드 이온(·O-2)을 생성하게 된다. 생성된 활성산소는 유해미생물 또는 유기화학물과 개열, 제거, 치환 반응 등을 통해 미생물사멸 및 유해화학물질들이 분해 가능하다. 이를 이용한 지하수 유해미생물 사멸기술, 장비, 실시간 지하수의 분석기술 및 정수처리, 지하수 물순환 시스템 개발뿐만 아니라 지하수 음용수 및 오염개선, 지하수 기저유출에 의한 오염원 저감으로부터 지류·지천, 하천 본류 수질개선 등의 대상지역에 활용 가능하다. 또한 광유도 활성산소는 기존 상수도 수처리에 있어 오존(O3) 처리와 이산화티탄을 이용한 AOP과정을 단일처리 공정으로, 기존 O3 의 특성상 확산 거리가 매우 길어 사람을 포함한 생체 내에 유입 시 다양한 부작용 발생과 O3 차폐시설 요구의 문제점 극복의 대안으로 환경 및 인체에 무해한 광유도 활성산소 시스템을 적극적으로 도입 및 적용해야 한다. 본 연구 목적은 정류상태 흡광분광기술을 이용한 실시간 수질 모니터링과 광유도 활성산소를 이용한 유해 미생물의 멸균효능 및 지하수 수질관리 기술로의 적용 가능성을 제시하고자 한다.

  • PDF

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

Review of the developmental trend of implant surface modification using organic biomaterials (생체활성 유기물로 표면이 개질된 임플란트 개발 추이 분석 연구)

  • Hwang, Sung-Taek;Han, In-Ho;Huh, Jung-Bo;Kang, Jeong-Kyung;Ryu, Jae-Jun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.49 no.3
    • /
    • pp.254-262
    • /
    • 2011
  • Purpose: This study aims to evaluate and prospect for current research trend and developmental perspectives via analyzing recent biomaterial coated-implants study. Materials and methods: To investigate each subject respectively, several biomaterials that are using for implant surface coating were set as 'keywords'. By these keywords, major research groups in each subject were chosen, and research trend of them was analyzed. Trend of In vivo studies that examined selected biomaterials were analyzed to evaluate commercial potential. Results: The collagen research accounted for 40% of total implant study, which was the highest, and fibronectin, BMPs (bone morphogenetic proteins) and RGD (Arg-Gly-Asp) peptides followed, which were ranked in descending order. Furthermore, figures of all four research subjects were also increased with time, especially a sharp increase in RGD research. According to the results of major research group, collagen that was combined with other organic and inorganic biomaterials was mostly examined, rather than using collagen only. Major research groups investigating BMPs mostly focused on rhBMP-2. In animal studies, collagen was used as resorbable membrane in guided bone regeneration (GBR) or drug carrier, while BMPs were used with bone graft materials or coating material for titanium implant surface. Conclusion: There is not consistency of results even in identical subjects research field. Many studies are ongoing to optimize combination between mechanical surface treatment and biomaterials such as extracellular matrix component and growth factors.

An Effective Block of Radioactive Gases for the Storage During the Synthesis of Radiopharmaceutical (방사성의약품 합성에서 발생하는 방사성기체의 효율적 차단)

  • Chi, Yong Gi;Kim, Dong Il;Kim, Si Hwal;Won, Moon Hee;Choe, Seong-Uk;Choi, Choon Ki;Seok, Jae Dong
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.2
    • /
    • pp.126-130
    • /
    • 2012
  • Purpose : Methode an effective block was investigated to deal with volatile radioactive gas, short lived radioactive waste generated as a result of the routinely produced radiopharmaceuticals FDG (2-deoxy-2-[$^{18}F$]fluoro-D-glucose) and compound with $^{11}C$. Materials and Methods : All components of the radiation stack monitoring and data management system for continuous radioactive gas detection in the air extract system purchase from fixed noble gas monitor of Berthold company. TEDLAR gas sampling bags purchase from the Dongbanghitech company. TEDLAR gas sampling bags (volume: 10 L) connected via paraflex or PTFE tubing and Teflon 3 way stopcock. When installing TEDLAR gas sampling bags in Hot cell on the inside and not radioactive gas concentrations were compared. According to whether the Hot cell inside a activated carbon filter installed, compare the difference in concentration of the radioactive gas $^{18}F$. Comparison of radiation emission concentration difference of module a FASTlab and TRACElab. Results : Activated carbon filter are installed in the Hot cell, a measure of the concentration of radioactive gas was 8 $Bq/m^3$. Without activated carbone filter in the hot cell was 300 $Bq/m^3$. Tedlar bag prior to installation of the radioactive gases a measure of the concentration was 3,500 $Bq/m^3$, $^{11}C$ synthesis of the measured concentration was 27,000 $Bq/m^3$. After installed a Tedlar bag and a measure concentration of the radioactive gases was 300 $Bq/m^3$ and $^{11}C$ synthesis was 1,000$Bq/m^3$. Conclusion : $^{11}C$ radioactive gas that was ejected out of the Hot cell, with the use of a Tedlar gas sampling bag stored inside. A compound of 11C is not absorbed onto activated carbon filter. But can block the release out by storing in a Tedlar gas sampling bag. We was able to reduce the radiation exposure of the worker by efficient radiation protection.

  • PDF

Effect of Particle Size on the Atomic Structure of Amorphous Silica Nanoparticles: Solid-state NMR and Quantum Chemical Calculations (비정질 규산염 나노입자의 입자 크기에 따른 원자 구조 변화 : 고상 핵자기공명 분석 및 양자화학계산 연구)

  • Kim, Hyun-Na;Lee, Sung-Keun
    • Journal of the Mineralogical Society of Korea
    • /
    • v.21 no.3
    • /
    • pp.321-329
    • /
    • 2008
  • Amorphous silica nanoparticles are among the most fundamental $SiO_2$ compounds, having implications in diverse geological processes and technological applications. Here, we explore structural details of amorphous silica nanoparticles with varying particle sizes (7 and 14 nm) using $^{29}Si$ and $^{1}H$ MAS NMR spectroscopy together with quantum chemical calculations to have better prospect for their size-dependent atomic structures. $^{29}Si$ MAS NMR spectra at 9.4 T resolve $Q^2,\;Q^3$ and $Q^4$ species at -93 ppm, -101 ppm, -110 ppm, respectively. The fractions of $Q^2,\;Q^3,\;O^4$ species are $7{\pm}1%,\;27{\pm}2%$, and $66{\pm}2%$ for 7 nm amorphous silica nanoparticles and $6{\pm}1%,\;21{\pm}2%$, and $73{\pm}2%$ for 14 nm amorphous silica nanoparticles. Whereas it has been suggested that $Q^2$ and $Q^3$ species exist on particles surfaces, the difference in $Q^{2}\;+\;Q^{3}$ fraction in both 7 and 14 nm particles is not significant, suggesting that $Q^2$ and $Q^3$ species could exist inside particles. $^{1}H$ MAS NMR spectra at 11.7 T shows diverse hydrogen environments, including physisorbed water, hydrogen bonded silanol, and non-hydrogen bonded silanol with varying hydrogen bond strength. The hydrogen contents in the 7nm silica nanoparticles (including water and hydroxyl groups) are about 3 times of that of 14 nm particles. The larger chemical shills for proton environments in the former suggest stronger hydrogen bond strength. The fractions of non-hydrogen bonded silanols in the 14 nm amorphous silica nanoparticles are larger than those in 7 nm amorphous silica nanoparticles. This observation suggests closer proximity among hydrogen atoms in the nanoparticles with smaller diameter. The current results with high-resolution solid-state NMR reveal previously unknown structural details in amorphous silica nanoparticles with particle size.

Evaluation on the Radiation Exposure of Radiation Workers in Proton Therapy (양성자 치료 시 방사선 작업 종사자에게 미치는 방사선 피폭에 대한 평가)

  • Lee, Seung-Hyun;Jang, Yo-Jong;Kim, Tae-Yoon;Jeong, Do-Hyung;Choi, Gye-Suk
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.24 no.2
    • /
    • pp.107-114
    • /
    • 2012
  • Purpose: Unlike the existing linear accelerator with photon, proton therapy produces a number of second radiation due to the kinds of nuclide including neutron that is produced from the interaction with matter, and more attention must be paid on the exposure level of radiation workers for this reason. Therefore, thermoluminescence dosimeter (TLD) that is being widely used to measure radiation was utilized to analyze the exposure level of the radiation workers and propose a basic data about the radiation exposure level during the proton therapy. Materials and Methods: The subjects were radiation workers who worked at the proton therapy center of National Cancer Center and TLD Badge was used to compare the measured data of exposure level. In order to check the dispersion of exposure dose on body parts from the second radiation coming out surrounding the beam line of proton, TLD (width and length: 3 mm each) was attached to on the body spots (lateral canthi, neck, nipples, umbilicus, back, wrists) and retained them for 8 working hours, and the average data was obtained after measuring them for 80 hours. Moreover, in order to look into the dispersion of spatial exposure in the treatment room, TLD was attached on the snout, PPS (Patient Positioning System), Pendant, block closet, DIPS (Digital Image Positioning System), Console, doors and measured its exposure dose level during the working hours per day. Results: As a result of measuring exposure level of TLD Badge of radiation workers, quarterly average was 0.174 mSv, yearly average was 0.543 mSv, and after measuring the exposure level of body spots, it showed that the highest exposed body spot was neck and the lowest exposed body spot was back (the middle point of a line connecting both scapula superior angles). Investigation into the spatial exposure according to the workers' movement revealed that the exposure level was highest near the snout and as the distance becomes distant, it went lower. Conclusion: Even a small amount of exposure will eventually increase cumulative dose and exposure dose on a specific body part can bring health risks if one works in a same location for a long period. Therefore, radiation workers must thoroughly manage exposure dose and try their best to minimize it according to ALARA (As Low As Reasonably Achievable) as the International Commission on Radiological Protection (ICRP) recommends.

  • PDF