• 제목/요약/키워드: 차음벽

검색결과 26건 처리시간 0.02초

공동주택 세대간 차음성능에 관한 연구 (A study on the sound insulation performance of partition wall between units of apartment house)

  • 주문기;오양기
    • KIEAE Journal
    • /
    • 제10권3호
    • /
    • pp.51-56
    • /
    • 2010
  • The sound insulation performance is one of the important factor that determined the amenity of housing life in residential building. Especially, Apartment house represents a korea habitation. So the importance of privacy and noise problems between habitable rooms are emphasized in these habitation. This study investigates and find a problem of sound insulation performance of partition wall of the apartment house in current state. The measurements were carried out in apartment house with and without a stair hall. And the measurements also carried out in current state and installing a sound absorbing material in receiving room and changing a front door and installing a inner door. In spite of the same partition wall, difference results were showed according to the stair hall. It is appeared that sound insulation performance without stair hall is 6-7dB(Dw) higher than that with stair hall. In case of without stair hall, sound insulation performance is Dw 49 for single number quantity for airbone sound. And In case of changing a front door and installing a inner door sound insulation performance is Dw 57 for single number quantity for airbone sound. The Results of measuring on the changes a front door and installed a inner door indicated that the flanking sound through front door influenced the sound insulation performance.

전력용 변압기 차음실 개발 (Development of the Soundproof Enclosure for Power Transformers)

  • 권동진;구교선;이욱륜
    • 조명전기설비학회논문지
    • /
    • 제23권10호
    • /
    • pp.107-114
    • /
    • 2009
  • 전력수요의 증가 및 도심지역의 확대로 도심지내 변전소에 전력용 변압기의 설치가 필요하나, 변전소의 전력용 변압기에서 발생하는 소음으로 인한 민원이 증가하고 있다. 따라서 전력용 변압기에서 발생하는 소음의 전파를 차단하기 위하여, 옥외 변전소의 전력용 변압기에는 방음벽을 적용하여 왔으며, 옥내 변전소에는 방음문, 방음 셔터 및 풍도형 방음장치 등을 적용하여 왔다. 그러나 이러한 방법에 의한 소음저감 효과는 만족할 정도에 이르지 못하는 실정이다. 본 연구에서는 전력용 변압기로부터 발생되는 소음을 효과적으로 차단하기 위해 변압기 차음실을 개발하였다. 개발한 변압기 차음실은 154[kV] 변압기에 적용하여 120[Hz] 성분에서 15[dB]의 소음저감 효과를 확인하였다.

차음성능이 향상된 경량벽체 개발 및 성능평가 연구 (A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

도로소음원에 대한 방음패널 형상별 반사소음 저감효과 (A Reduction Effect in Noise Reflection by Different Shapes of Soundproofing-panel)

  • 김일호;박태호;장서일;이혜인
    • 대한환경공학회지
    • /
    • 제37권2호
    • /
    • pp.120-125
    • /
    • 2015
  • 도시화의 가속화와 더불어 도심의 교통량의 증가로 도로소음피해를 최소화하기 위하여 방음벽의 설치 수요가 증가하고 있다. 설치되고 있는 여러 형태의 방음벽 중, 반사형 방음패널의 경우 불투명 방음패널과 달리 시야를 가리지 않으므로 방음시설을 요구하는 거주자들에게 인기를 얻고 있다. 하지만 반사형 방음패널의 경우, 반사음에 의한 2차 피해를 유발시켜 피해를 줄일 수 있는 방음벽 개발의 필요성이 대두되고 있다. 이에 본 연구에서는 반사형 방음패널의 전면형상 및 기하학적 형태를 변화시켜 반사음의 전달을 최소화 시킬 수 있는 형상을 연구하였다. 일반형 반사형 방음패널과 형상별 방음패널의 반사소음 저감 효과를 비교 한 결과, 곡선형 방음패널이 1.5 dB의 소음저감 효과가 있었다. 또한, 반사음의 증가 또는 감소는 형상별 설계인자에 따라 변화하는 것을 알 수 있었다. 이러한 결과는 방음벽 전면 현상에 따른 반사소음의 저감 기술의 가능성을 보여주는 결과라고 판단된다.

풍하중 저감형 방음판의 실증 연구 (An Empirical Study of Soundproof wall with Reduced Wind Load)

  • 최진규;이찬영
    • 한국산학기술학회논문지
    • /
    • 제19권12호
    • /
    • pp.272-278
    • /
    • 2018
  • 최근 도시개발과 생활수준의 향상으로 인해 교통량이 크게 증가하고 있으며, 이와 더불어 증가되는 도로 소음으로 인해 많은 민원이 제기되고 있다. 이에 대한 대책으로 도로변에 높은 방음벽이 설치되고 있으나 방음벽 주요 설계 요건인 풍하중은 공사비의 기하급수적인 증가뿐만 아니라 방음벽 높이 제한의 요인으로 작용하게 된다. 이에 본 연구에서는 기존 방음벽 수준의 차음 성능과 더불어 풍하중을 획기적으로 저감할 수 있는 우수한 가격 경쟁력의 방음벽을 개발 하는 것을 목적으로 한다. 본 연구 대상의 방음판은 헬름홀츠의 공명기 이론을 바탕으로 공기와 같은 유체는 통과하고 소음은 저감할 수 있는 신개념 통기형 방음판에 해당된다. 본 연구에서는 실 크기의 금속재 방음판을 제작하여 음압투과손실실험, 풍동실험 및 재료품질 실험을 수행하여 고속도로의 품질기준을 만족하는 결과를 도출하였다. 또한 신뢰성을 검증하기 위해 현장에 제작 및 설치를 하고 시간대 별로 소음을 측정하여 방음판의 소음 차단 효과를 확인하였다. 향후 도로에 통풍형 방음벽을 설치할 경우 높은 소음 차단 효과로 인하여 쾌적한 생활환경을 조성할 수 있을 것으로 예상된다.

폴리머계 단일 및 이중구조 방음패널의 차음특성 비교분석 (Comparison of Sound Transmission through Single and Double-layer Polymer Panels)

  • 김일호;이주행;손진희
    • 대한환경공학회지
    • /
    • 제36권9호
    • /
    • pp.597-603
    • /
    • 2014
  • 본 연구에서는 PC, PMMA, HDPE, PP를 소재로 한 방음패널의 두께와 구조적 특성, 소재가 차음성능에 미치는 영향을 알아보았다. 각 소재로 구성된 단일 패널의 음향투과손실을 비교한 결과, PC, PMMA, HDPE, PP 순으로 음향투과손실이 높게 나타났으며, 질량법칙에 따르는 결과임을 확인하였다. 단일패널의 두께에 따른 투과손실을 비교해보면, 4 mm 단일패널에 비해 8 mm 두께의 투과손실이 약 5~6 dB(A) 크게 측정되었다. 또한 두께가 2배가 됨에 따라 일치효과 주파수가 낮아져 4,000~5,000 Hz에서 투과손실이 감소하는 영역이 발생하였으며, 4 mm 단일패널보다 투과손실이 작았다. 두 개의 4 mm 패널 사이에 공기층을 두어 이중으로 구성한 실험체를 대상으로 한 투과손실 실험 결과, 300 Hz 이하의 주파수에서는 동일한 두께인 8 mm의 단일패널과 효과가 비슷하였으며, 2,000 Hz 이상의 고주파수 대역에서 8 mm 단일패널에 비해 효과가 매우 뛰어났다. 반면 공명(resonance) 주파수와 인접한 500~630 Hz 대역에서 투과손실이 낮아지는 것을 알 수 있었다.