• Title/Summary/Keyword: 차양막

Search Result 8, Processing Time 0.023 seconds

The Influence of the Landscaping Shade Membrane's Brightness on the Mean Radiant Temperature(MRT) of Summer Outdoor (조경용 차양막 재료의 명도가 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.43 no.5
    • /
    • pp.65-73
    • /
    • 2015
  • The purpose of this study was to compare the Mean Radiant Temperature(MRT) under two landscaping shade membranes, white and black, with those of natural outdoor spaces at summer midday. An additional perforated black shading net was applied and compared for the consideration of the practical application. The average MRT at the height of 2.4m, 10cm below the membranes of black, white, and perforated black were $49.1^{\circ}C$, $41.6^{\circ}C$ and $36.8^{\circ}C$ respectively, while that of open sky was $41.8^{\circ}C$. This indicates that a closer position to the darker membrane caused a higher MRT. At the height of 1.1m and 1.7m, the difference of MRT between the black and the white membranes was slight, while the value of white was unexpectedly higher than the black. The MRT of black perforated net showed the lowest value at every height. The black membrane absorbed more solar radiation than the white, which caused the greater release of long wave radiation and higher temperature near the membrane itself. In spite of the higher albedo of the white membrane, the higher solar radiation transmittance rate of which seemed to cause the slightly higher MRT than the black at the hight of 1.1m and 1.7m. In summary, the performance of the black membrane was slightly better than the white in terms of the air conditioning of the human related space around the height of 1.1m and 1.7m, when the shading membranes were at 2.5m height.

Environmentally friendly Awning system using solar energy (태양에너지를 이용한 친환경 Awning 시스템)

  • Kang, Min-Wo;Choi, Myoung-hoon;Zhao, Yun-Jae;Kim, Hyun-Jo;Yi, Hyeong-Gi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.05a
    • /
    • pp.164-165
    • /
    • 2015
  • 최근 친환경 에너지와 주변 환경을 응용하는 기술이 발달함에 있어 환경 에너지의 관심이 높아지고 있다. 특히 태양빛은 에너지와 환경적 측면에서 중요한 부분을 차지하고 있으므로 그러한 태양열을 이용한 장치의 연구는 사람의 쾌적한 삶을 위해 필요하다고 할 수 있을 것이다. 그중에 실내로 유입되는 태양빛을 조절하는 장치로 커텐, 블라인드, 자외선 차단 유리등 여러 가지 있지만 상업건물에서 가장 효과적으로 많이 사용되고 있는 시스템 중 하나는 Awning시스템을 많이 사용하고 있다. 이러한 제품은 오존층 문제등의 환경에 관심이 높아지면서 전원주택 및 상가 등을 중심으로 새롭게 관심이 고조되고 있으며, 모양과 기능이 다양하게 개발되고 있다. 그러나 기존의 Awning 시스템은 포리에스테르 또는 아크릴 원착사 원단을 이용한 고정식과 접이식이 있으며 차양시스템은 수동과 자동이 있다. 이러한 시스템은 대부분 태양의 직사광선이나 비를 차단 할 수 있는 기능만 가지고 있다. 본 논문에서는 Awning 시스템에 솔라 판넬을 이용한 친환경 자동 Awning 시스템의 개발이 필요하다. 이 Awning 시스템은 직사광선의 차양 및 빗물방지 와 태양에너지를 얻을 수 있도록 개발 한다.

  • PDF

Study on Manufacturing Technology of Coating Yarns for Awning Fabrics (차양막 직물용 코팅사 제조기술에 관한 연구)

  • Kim, Seung-Jin;Lee, Eun-Ho;Heo, Kyeung;Kim, Hyun-Ah
    • Textile Coloration and Finishing
    • /
    • v.27 no.1
    • /
    • pp.35-49
    • /
    • 2015
  • This paper investigated optimum process conditions of coating yarn for awning fabric. For this purpose, the simulation for processability and yarn quality using SPSS statistics package was carried out, and PP/TPO and PET/PVC coating yarns specimens were made with variation of extruder temperature and feed speed of core yarn on the yarn coating machine for examining simulation result. It was revealed that optimum coating conditions of PP/TPO 1000d coating yarn were extruder temperature $150^{\circ}C$, and core yarn feed speed 400~500m/min. Mechanical property and thermal shrinkage of PP/TPO coating yarn made at this conditions were best and core evenness rates of these coating yarns by yarn compression tester were also superior, which was certified by SEM photograph. In addition, these experimental results were coincided with simulation results. It was found that, in PET/PVC coating yarn, yarn physical properties between 1500d and 1200d coated yarns were not shown any difference, and core evenness rates of these coating yarns were superior. It revealed and concluded that these simulated coating conditions are applicable to production field.

The Influence of the Landscaping Shade Materials' Porosity on the Mean Radiant Temperature(MRT) of Summer Outdoors (조경용 차양 재료의 공극률이 하절기 옥외공간 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.45 no.2
    • /
    • pp.60-67
    • /
    • 2017
  • The purpose of this study was to evaluate the influence of landscaping shade materials' porosity on the Mean Radiant Temperature (MRT) of summer outdoors. The MRTs were measured under seven different types of black membranes with holes of 8mm diameter at different intervals applied on the top of wooden boxes, and compared with those of four additional control plots with or without shade and lateral boxes. The applied porosities were 0.5, 1, 2, 4, 8, 16%, and 32%, and three groups of three shades were compared sequentially from August 13 to September 8, 2016. The MRTs under the shade without lateral block, no shade with lateral block, and shade with lateral block were $33.08^{\circ}C$, $45.80^{\circ}C$, and $42.3^{\circ}C$, respectively, while that of no-shaded no-lateral screen was $44.26^{\circ}C$, based on records from 11:00 AM to 3:00 PM on the days with a peak globe temperature higher than $30^{\circ}C$. An ANCOVA analysis showed that the MRTs under the shades with 0.5, 1, 2, 4, 8, 16%, and 32% porosities were calculated as 43.40, 43.10, 41.49, 40.43, 39.61, $37.91^{\circ}C$, and $38.12^{\circ}C$, respectively, while that in the no shaded control box was $45.8^{\circ}C$. The curve fitted between MRTs and the porosity showed a U-shaped quadratic function with the minimum MRT at 16% practically or 22.5% statistically.

A study on the solar panel-powered Awning system (태양광패널을 이용한 Awning 시스템에 관한 연구)

  • Jeong, Jae-Hoon;Park, Won-hyeon;Lee, Dong-Heon;Choi, Myoung-Hoon;Kim, Min;Kim, Hyun-Jo;Zhao, Yun-Jae;Lee, Won-Sang;Kim, Song-Hyun;Yi, Hyeong-Gi
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.743-744
    • /
    • 2016
  • Due to the many amenities of a modern power with solar power and green energy alternative to injury by cutting down on the number of solar energy and pollution and environmental factors. There is still much research and trying to incorporate a variety of applications. In this paper, create a daytime energy by fusing solar panels and billboards, and at night has the advantage that you can save more energy used to sign by the sign serves also and at the same time energy acts like a tent when the day by using the power usage is expected to be higher.

  • PDF

A Study on Thermal Satisfaction of Domestic Heat Wave Reduction Facilities (국내 폭염 저감 시설의 온열 만족도에 대한 연구)

  • Jun, Yong-Joon;Park, Lyool;Park, Kyung-Soon
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.18 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • As abnormal climates occur due to the increase in greenhouse gases at home and abroad, various problems such as human casualties, crop damage, energy depletion, and economic loss due to heat diseases, which are one of the extreme climate phenomena, are following one after another. In response, the government has established the 'Climate Crisis Response Special Committee' since 2018, when it recorded the greatest damage in history due to heat waves, and has been carrying out budget formation and reform of laws and systems every year to respond to heat waves. However, in relation to the heat wave damage reduction facility that is being expanded with a large budget, there is no prior research related to the degree of heat loss due to the use of the facility, the difference in effects between specific groups, and the economic effect that comes back compared to the invested budget. Therefore, from a midto long-term perspective, it is expected that it will be difficult to establish a clear direction for policy making. Therefore, in this study, representative facilities were selected according to the principle of heat reduction among the currently expanded heat damage reduction facilities, and a questionnaire survey was conducted for users of each reduction facility (waterfall, awning, pond, and elastic pavement). Accordingly, the change in the sense of heat according to the use of the heat damage reduction facility was checked, and the change in the sense of heat according to the group characteristics (gender, age, metabolic rate) was analyzed to examine the characteristics of the relationship between the facility and the users.

The Influence of Ventilation and Shade on the Mean Radiant Temperature of Summer Outdoor (통풍과 차양이 하절기 옥외공간의 평균복사온도에 미치는 영향)

  • Lee, Chun-Seok;Ryu, Nam-Hyung
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.100-108
    • /
    • 2012
  • The purpose of the study was to evaluate the influence of shading and ventilation on Mean Radiant Temperature(MRT) of the outdoor space at a summer outdoor. The Wind Speed(WS), Air Temperature(AT) and Globe Temperature(GT) were recorded every minute from $1^{st}$ of May to the $30^{th}$ of September 2011 at a height of 1.2m above in four experimental plots with different shading and ventilating conditions, with a measuring system consisting of a vane type anemometer(Barini Design's BDTH), Resistance Temperature Detector(RTD, Pt-100), standard black globe(${\O}$ 150mm) and data acquisition systems(National Instrument's Labview and Compfile Techs' Moacon). To implement four different ventilating and shading conditions, three hexahedral steel frames, and one natural plot were established in the open grass field. Two of the steel frames had a dimension of $3m(W){\times}3m(L){\times}1.5m(H)$ and every vertical side covered with transparent polyethylene film to prevent lateral ventilation(Ventilation Blocking Plot: VP), and an additional shading curtain was applied on the top side of a frame(Shading and Ventilation Blocking Plot: SVP). The third was $1.5m(W){\times}1.5m(L){\times}1.5m(H)$, only the top side of which was covered by the shading curtain without the lateral film(Shading Plot: SP). The last plot was natural condition without any kind of shading and wind blocking material(Natural Open Plot: NP). Based on the 13,262 records of 44 sunny days, the time serial difference of AT and GT for 24 hour were analyzed and compared, and statistical analysis was done based on the 7,172 records of daytime period from 7 A.M. to 8 P.M., while the relation between the MRT and solar radiation and wind speed was analyzed based on the records of the hottest period from 11 A.M. to 4 P.M.. The major findings were as follows: 1. The peak AT was $40.8^{\circ}C$ at VP and $35.6^{\circ}C$ at SP showing the difference about $5^{\circ}C$, but the difference of average AT was very small within${\pm}1^{\circ}C$. 2. The difference of the peak GT was $12^{\circ}C$ showing $52.5^{\circ}C$ at VP and $40.6^{\circ}C$ at SP, while the gap of average GT between the two plots was $6^{\circ}C$. Comparing all four plots including NP and SVP, it can be said that the shading decrease $6^{\circ}C$ GT while the wind blocking increase $3^{\circ}C$ GT. 3. According to the calculated MRT, the shading has a cooling effect in reducing a maximum of $13^{\circ}C$ and average $9^{\circ}C$ MRT, while the wind blocking has heating effect of increasing average $3^{\circ}C$ MRT. In other words, the MRT of the shaded area with natural ventilation could be cooler than the wind blocking the sunny site to about $16^{\circ}C$ MRT maximum. 4. The regression and correlation tests showed that the shading is more important than the ventilation in reducing the MRT, while both of them do an important role in improving the outdoor thermal comfort. In summary, the results of this study showed that the shade is the first and the ventilation is the second important factor in terms of improving outdoor thermal comfort in summer daylight hours. Therefore, it can be apparently said that the more shade by the forest, shading trees etc., the more effective in conditioning the microclimate of an outdoor space reducing the useless or even harmful heat energy for human activities. Furthermore, the delicately designed wind corridor or outdoor ventilation system can improve even the thermal environment of urban area.

Flexible CIGS 태양전지

  • Jeong, Yong-Deok;Jo, Dae-Hyeong;Han, Won-Seok;Park, Rae-Man;Lee, Gyu-Seok;Kim, Je-Ha;O, Su-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.29-29
    • /
    • 2010
  • 건물일체형 태양전지 (BIPV; building integrated photovoltaics)나 야외 태양광 발전 차양 등의 태양광 발전에는 기존의 유리 기판 태양전지보다 가볍고 유연한 flexible 박막 태양전지가 설치하고 운영하는데 적합하다. 이러한 flexible 박막 태양전지는 자동차나 휴대기기의 전원이나 배터리의 충전기기로도 쓰이며 그 수요가 증가 추세에 있다. 특히, flexible Cu(In, Ga)$Se_2$(CIGS) 박막 태양전지는 기존의 flexible 실리콘 박막 태양전지보다 효율이 높아서 앞으로 성장 잠재력이 매우 높다. 세계적으로도 많은 기업이 상용화를 추진하고 있으며, 2007년부터 시장에 진입하고 있다. 그러나 현재의 flexible CIGS 박막 태양전지는 유리 기판 CIGS 박막 태양전지보다 효율이 낮고 패키지를 유리에서 플라스틱으로 대체하기 때문에 수명이 짧다. 또한, 아직도 완전한 양산 체제로 전환이 이루어지지 않았기 때문에 해결해야 할 문제점이 많이 있다. Flexible 기판으로는 스테인리스 스틸이나 폴리머 기판이 사용되는데, 유리 기판에 비해 저가 태양전지를 제조할 수 있을 뿐만 아니라 roll-to-roll 공정을 적용할 수 있어 가격 경쟁력을 확보할 수 있다. 특히, 금속 유연기판을 사용할 경우, 유리 기판에 비해 상대적으로 고온 공정이 가능한 장점이 있다. 그러나, 금속 기판을 사용할 경우 해결해야 할 두 가지 이슈가 있다. 첫째, CIGS 흡수층 형성에 도움을 주는 Na의 공급 문제이다. 유리 기판의 경우 기판에 포함되어 있는 Na이 확산을 통해 공급되지만, 금속 기판의 경우 별도의 Na 공급 방법을 고려해야 한다. 둘째, 불순물 확산 방지막 및 전기 절연층으로 사용되는 유전체 박막의 문제이다. 현재 다양한 금속 산화물 유전체 박막을 사용한 연구가 진행되고 있다. 본 논문에서는 flexible CIGS 박막 태양전지의 기술적 이슈 및 현재 연구 현황을 살펴보고, 스테인리스 스틸 기판을 이용한 CIGS 박막 태양전지에서 유전체 확산 방지막에 따른 특성을 비교하고자 한다. 스테인리스 스틸 기판의 불순물로부터의 확산을 방지하기 위하여 두 종류(intrinsic ZnO와 SiOx)의 유전체 박막을 각각 Na가 도핑된 Mo층과 스테인리스 스틸 기판 사이에 삽입하여 소자를 제작하였다. 확산 방지막이 없는 경우, SiOx층을 사용한 경우, 그리고 intrinsic ZnO 층을 사용한 경우에, 효율은 각각 7.47, 11.64, and 13.95%로 나타났다. 셀의 크기는 $0.47\;cm^2$이고, 반사방지막은 사용하지 않았다.

  • PDF