• Title/Summary/Keyword: 차수벽

Search Result 100, Processing Time 0.032 seconds

Characteristics of Bentonite Filter Cake on Vertical Cutoff Walls Evaluated by Modified Fluid Loss Test (수정 fluid loss 시험을 이용한 연직 차수벽에 생성된 벤토나이트 필터케익 특성 평가)

  • Nguyen, The-Bao;Park, Moon-Seo;Lim, Jee-Hee;Choi, Hang-Seok;Han, Shin-In
    • Journal of the Korean Geotechnical Society
    • /
    • v.27 no.2
    • /
    • pp.53-62
    • /
    • 2011
  • During the construction of vertical cutoff walls, filtration of bentonite slurry into the adjacent soil formation fabricates a layer of bentonite filter cake on the wall surface. The bentonite filter cake possesses much lower hydraulic conductivity compared to that of backfill materials in the cutoff wall. Hydraulic conductivity of bentonite filter cakes formed with three different types of bentonites has been measured by performing the modified fluid loss test under various pressure levels. Three different mixture ratios, 4, 6, and 8%, were selected for fabricating bentonite filter cakes to represent common field conditions. Two analysis methods for interpreting the experimental data from the modified fluid loss tests were employed to estimate hydraulic conductivity of the bentonite cakes. The range of hydraulic conductivities of the three bentonite cakes is between $2.15{\times}10^{-11}\;m/s$ and $2.88{\times}10^{-10}\;m/s$ which is 1 to 2.7 orders of magnitude lower than that of the design cutoff wall backfill. The stress distribution and thickness of the bentonite cakes were also evaluated in this paper.

Experimental Study of Frozen Barrier Using Artificial Ground Freezing System (인공지반동결 시스템을 이용한 동결차수벽의 실험적 연구)

  • Shin, Eun-Chul;Kang, Hee-Myeong;Park, Jeong-Jun;Kim, Sung-Hwan
    • Journal of the Korean Geosynthetics Society
    • /
    • v.8 no.3
    • /
    • pp.35-44
    • /
    • 2009
  • The purpose of this study was to prevent spreading of contaminants from movement of underground water by creating a barrier using artificial freezing method on a soil contaminated by oils and various NAPLs. Specimens with 80% and 90% degrees of saturation were prepared to form freezing barrier using artificial freezing method. With increasing freezing time of freezing barrier, barrier was formed faster in the specimen with 90% degree of saturation by about an hour compared to the specimen with 80% degree of saturation. In addition, thinnest thickness of frozen barrier in both specimens was 50mm after 12 hours of freezing time, showing expansion of freezing area with time. The results of this study can be applied to barrier in waste reclamation sites and contaminated regions or to flow control of contaminants.

  • PDF

Experimental Study on the Wake Characteristics of a Perforated Vertical Wall with Gap in the 2-Dimensional Flow (2차원 흐름 중에 놓인 틈새를 갖는 수직벽 후류 특성에 관한 실험적 연구)

  • Jo Dae-Hwan;Oh Kyoung-Gun;Lee Gyoung-Woo
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2005.10a
    • /
    • pp.135-140
    • /
    • 2005
  • There are cofferdam and watertight wall to prevent of circulation or pollution during building of ocean structures like a dam and bridge in the harbors area and the sea. Inflow fluid and base of structure is important thing as one of the structural design factors for this interception wall like a cofferdam and watertight wall. In this study, it is revealed that at least 500 instantaneous velocity field data are required for ensemble average to get reliable turbulence statistics. The turbulent shear flow around a surface-mounted vertical wall was investigated by using the two-frame PIV(CACTUS 3.1) system and Mean velocity distributions have also been measured in the whole flow field.

  • PDF

Compaction Characteristics of Zone-1 Material in Concrete Faced Rockfill Dam (콘크리트 표면 차수벽형 석괴댐의 Zone-1재료에 대한 다짐특성)

  • Yea, Geu-Guwen;Han, Sang-Hyun;Lee, Jae-Ho
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.2
    • /
    • pp.9-15
    • /
    • 2007
  • Bedding zone in CRFD (Concrete Faced Rockfill Dam) requires bearing capacity to support the concrete face slab uniformly. Also, shear strength which is a key factor in slope stability and impermeability which is to prevent a loss of soils in case of leakage of concrete slab face are needed. In this study, trial prototype construction for bedding zone in CRFD was performed to investigate the compaction characteristics of bedding zone according to the frequency of compaction, water contents and so on. As a results of series of field test, the compaction characteristics of bedding zone in CRFD was affected considerably by the depth of compaction layer and frequency of compaction.

  • PDF

Evaluation of Permeability on Construction Material in CFRD Bedding Zone (CFRD Bedding Zone의 축조재료에 대한 투수성 평가)

  • Han, Sang-Hyun;Yea, Geu-Guwen
    • The Journal of Engineering Geology
    • /
    • v.19 no.4
    • /
    • pp.493-499
    • /
    • 2009
  • Recently, the construction of Concrete Faced Rockfill Dam (CFRD) is increasing because rock material resources are plenty in Korea. Bedding zone in the CFRD is necessary enough bearing capacity to support the concrete face slab uniformly and enough impermeability to prevent the loss of fine soils in case of leakage from the concrete slab face. Therefore, cut-off the water leakage in bedding zone securely is the key factor influencing the safety of CFRD. Tested materials satisfied with the specification of particle size distribution at the Bedding Zone area are chosen for conducting permeability tests, which are done to evaluate the property of cut off the materials. Based on the test results, the effects of cut off the materials are investigated by considering the coefficient of permeability, the soil particle distribution, and the dry unit weight. Especially, the relationships between coefficient of permeability with effective size(D10), dry unit weight, and weight passing percent the No.4 sieve are suggested, and also the variation of coefficient of permeability with time are proposed.

A Study on Methohs Reducing Groundwater Contamination Around Kimpo Landfill (김포매립지 주변 지하수오염 확산 저감 방법 연구)

  • 김계남;구자공;원휘준;오원진
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2000
  • In order to reduce the groundwater contamination around the Kimpo landfill in Korea by the leakage of the leachate within it, The method establishing 5 sets of Radial Collector Well Laterals(RCWLs) within the landfill, the method utilizing the wells dewatering the condensed water, the method establishing an interception wall to the 2nd layer at the circumference of the landfill and 22 sets of RCWLs within it, and the method establishing an interception wall to the 3rd layer and 40 sets of RCWLs were studied. Hydraulic parameters were measured for this study and then the groundwater flow and contaminant transport systems around the Kimpo landfill were analyzed with the MODFLOW and MT3D models. Conclusively, the method establishing an interception wall to the 2nd layer and 22 sets of RCWLs was evaluated as the most stable and economical option to reduce groundwater contamination concentration below drinking water standards.

  • PDF

The Estimation of the Uplift Pressure and Seepage Discharge under Gravity Dam: Development of a 3-D FDM Model in Heterogeneous Media (중력댐 하부 침투류에 의한 양압력과 누수량 산정 -비균질 3차원 FDM 모형의 개발 및 적용-)

  • Kim, Sang-Jun
    • Journal of Korea Water Resources Association
    • /
    • v.46 no.12
    • /
    • pp.1221-1234
    • /
    • 2013
  • The purpose of this study is to suggest the methodology for the computation of uplift pressure and discharge of the seepage flow under gravity dam. A 3-dimensional FDM model is developed for this purpose and this model can simulate the saturated Darcian flow in heterogeneous media. For the verification of the numeric model, test simulation has been executed and the mass balance has been checked. The error does not exceed 3%. Using the developed model, The uplift pressure and seepage flow discharge under gravity dam has been calculated. The uplift pressure shows the similar pattern, comparing with the result of flow-net method. As the length of grout curtain increases, the uplift pressure decreases linearly, but the seepage flow discharge shows the non-linear decreasing pattern. The coefficients of the formulas in the dam-design criteria have been analysed, and ${\alpha}=1/3$ corresponds to the value when the length of curtain grout is 70% of the aquifer height. The uplift pressure near the pressure relief drain has the big curvature vertically and horizontally. The developed model in this study can be used for the evaluation of the effects of seepage flow under gravity dam.

Geophysical Investigation of the change of geological environment of the Nanjido Landfill due to the Stabilization Process (난지도 매립장의 안정화에 따른 지질환경 변화 조사를 위한 지구물리 탐사)

  • Lee, Kie-Hwa;Kwon, Byung-Doo;Rim, Hyoung-Rae;Yang, Jun-Mo
    • Journal of the Korean Geophysical Society
    • /
    • v.3 no.2
    • /
    • pp.113-126
    • /
    • 2000
  • We have conducted multiple geophysical surveys to investigate the geoenvironmental change of the Nanjido Landfill due to the stabilization process. Geophyscial surveys are comprized of gravity, magnetic, dipole-dipole electrical and SP methods. Due to the field conditions, surveys were conducted on the top surface of the landfill no.2 and southern border areas in front of landfills. The gravity anomalies obtained on the top surface of the landfill no.2 in 1999 show that the gradient of the anomaly on the central area is decreasing in comparison with that observed four years ago. The complexity of magnetic anomaly pattern it also decreasing. These facts suggest that the stabilization work of the Nanjido landfill makes some progress by compaction process due to repetitive subsidence and refilling. The dipole-dipole electrical resistivity and SP data obtained on the outside of the waterproof wall at the landfill no.1 were severely affected by unsatisfactory surface conditions. On the other hand, the dipole-dipole electrical resistivity profiles obtained on the inside and outside parts of the waterproof wall at the landfill no.2 show the blocking effect of leachate flow by the waterproof wall. Few SP anomalies are observed on the top and side surfaces of the landfill no.2, but SP anomalies obtained on the base area inside the waterproof wall strongly reflect the effect of leachate collecting wells.

  • PDF