• Title/Summary/Keyword: 집진장치

Search Result 191, Processing Time 0.034 seconds

Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector (융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성)

  • Park, Young Ok;Jeong, Ju Yeong
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

A Study on the Evaluation of Dynamic Characteristics of the Pantograph for the Korean High-Speed Train through 350km/h Trial Running Test (350km/h 본선 주행시험을 통한 한국형 고속열차 판토그라프의 접촉력 특성 평가 연구)

  • Lee Hi-Sung;Mok Jin-Yong
    • Journal of the Korean Society for Railway
    • /
    • v.8 no.4
    • /
    • pp.342-347
    • /
    • 2005
  • The Korean High-Speed Train(HSR 350x) had been developed by through 'G7-R&D project' in 1996-2002, and has been testing and evaluating it's reliability on the high-speed line until now. A number of core equipments designed and developed by using domestic technologies were boarded on the HSR 350x. In order to verify the performance of HSR 350x and core equipments such as traction system, brake system and pantograph, sophisticated testing and evaluating procedures should be considered and applied. In this paper, the tested and analysed results about the dynamic characteristics of HSR 350x pantograph are introduced in a view point of the mean contact force and it's variation trend, criterion of current collection, and up-lifting of contact wire when the MSR 350x running up to 350 km/h. Through the test and evaluation, we verified that HSR 350x pantograph had an excellent current collection performance and good dynamic characteristics as it had been designed.

A Study on the Mass Collection Efficiency in Collector Step of Electrostatic Precipitator by Physical Gas Characterization (전기집진장치에서 가스의 물리적인 특성에 따른 포집구역내의 입자포집율 연구)

  • Ha, Sang-An;Im, Gyeong-Taek;Sin, Nam-Cheol
    • Journal of Environmental Science International
    • /
    • v.7 no.1
    • /
    • pp.36-40
    • /
    • 1998
  • This study was carried out to investigate the collection Efficiency of mass in collector step at the different of physical gas characterization. This work has focused on the dependence of the collection efficiency of mass in the collector zone of a two-stage set up field with gas temperature T and the dew point tmeperature. To identify the dependence of the mass collection efficiency on the Bounded plate of the collector zone MP.k by the spectre electric resistance of dust $p_e$. and the relative humidify ${\varphi}$, 20 at- tempts have been made with three different gas temperature ($50{\circ}C, 80{\circ}C, 110{\circ}C$) at different dew point. At the specific electric resistance of dust $p_e$=$10^6{\Omega}m$ which relative humidity corresponds to $\phi$ > 15%, a easy rise of the sounded plate secluded dust mass share was measured atwain. As the result of the higher cohesion imprisonment power due to the adsorbtion of particle, the rinse of the relative humidity developed on the particle surface. Therefore, the collection efficiency of mass was not predominant the high temperature T in the collector zone, neither was the pecific ellectric resistance of dust dependent.

  • PDF

Investigation of Characteristics of Electrostatic Bag Filter with Discharge Electrode Shapes and Filter Properties (방전극 형상 및 여과재에 따른 정전 여과집진장치특성에 관한 연구)

  • 김정일;여석준
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.3
    • /
    • pp.237-250
    • /
    • 1998
  • In this study, the characteristics of electrostatic bag filter to overcome the main problems such as the high pressure drop and low collection efficiency for submicron particles are investigated with the experimental parameters. Especially, the experiment is carried out focusing on collection efficiency and pressure drop change mechanism as a function of discharge electrode shapes and filter properties, including the applied voltages, filtration velocities and particle concentrations, etc . Results show that the collection efficiency is improved over 30% for the fine particle below 1 pm and pressure drop reduction ratio (PDRR) increases in the following order 4 mm screwy > 4 mm square > 4mm round discharge electrodes . For the filter properties, Nomex is more effective than PE under the influence of electrostatic force. Applying 30 kV for a screwy discharge electrode, higher overall collection efficiency is maintained in spite of the increment of filtration velocity over four times (8 m/min) in comparison with that of 2 m/min and PDRR are highly shown over 80o1o with various filtration velocities, 5, 8, 11 m/min.

  • PDF

A Study on the Development of Dust Collection System for Hull Repair (선체 표면 공사시 발생하는 분진 수거 장치 개발에 관한 연구)

  • Yoa, S.J.
    • Journal of Power System Engineering
    • /
    • v.8 no.2
    • /
    • pp.31-38
    • /
    • 2004
  • The main purpose of this study is to investigate the characteristics of hybrid collection system combined with centrifugal force of cyclone and filtration of bag filter in one unit system. The experiment and numerical simulation are executed for the analysis of collection efficiency and pressure drop characteristics of hybrid system in comparison with those of a general fabric bag filter with the various experimental parameters such as inlet velocity(filtration velocity), dust concentration and dust type, etc.. In present system, dust particles tangentially coming into the system body are controlled by the centrifugal force effect, and the next collection is made out by the filtration mechanism in the fabric filter media. Therefore, the effective first collection causes the decrease of dust loading on the fabric filter, and it presents quite a lower pressure drop of fabric filter than that of a general fabric filter. At the inlet velocity, $21{\sim}27m/sec$ and inlet concentration(fly ash) $300mg/m^3$, pressure drops through the filter media of hybrid system are shown lower as $10{\sim}22mmH_2O$ comparing to those($17{\sim}33mmH_2O$) of a general fabric bag filter.

  • PDF

A Study on Tar Removal in Syngas Produced from Woodchip Gasification Using Oxidation Catalyst and Utilization of Syngas by Co-combustion (산화촉매를 이용한 우드칩 가스화 합성가스 내 타르 제거 및 합성가스 혼합연소 이용기술 연구)

  • Yoon, SangJun;Kim, YongKu;Lee, JaeGoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.175.1-175.1
    • /
    • 2011
  • 우드칩을 포함하는 화석연료대비 발열량이 낮은 바이오매스를 가스화를 통하여 활용하는 경우 타르 및 수트를 포함하는 저열량의 합성가스가 생성된다. 이러한 합성가스를 엔진을 통한 발전, 스팀, 수소 및 화학제품 생산으로 활용하기 위해서는 고효율의 타르 정제 및 제거가 필수적이다. 특히 착화가 어렵고 연소온도 및 연소율이 낮으며, 화염구간이 좁은 저열량의 합성가스를 이용하여 스팀을 생산하기 위해서는 많은 문제점으로 인하여 기술 개발이 필요하다. 본 연구에서는 하향류식 가스화기를 이용하여 우드칩을 연료로 합성가스를 제조하였으며, 합성가스에 포함되어 있는 타르 및 수트와 같은 미반응 물질을 제거할 수 있는 집진, 세정장치를 설계 및 제작하였다. 특히 고효율 타르의 제거를 위하여 두 종류의 산화촉매를 이용한 합성가스 내 타르의 제거 연구를 수행하였다. Ru 촉매를 이용하는 경우 합성가스 내 타르의 농도를 100ppb 정도까지 저감이 가능하였다. 정제된 합성가스는 유류 혼소 버너를 통하여 보일러 연소실에서 혼합연소되어 30만kcal/h의 열을 공급함으로써 스팀을 생산 하였으며, 생성된 스팀은 블록 건조 시설에서 이용하였다.

  • PDF

Emission Characteristics of PCDD/Fs in MSW Incinerator(I) - The Effect of Air Pollution Control Device - (도시폐기물 소각공장에서의 다이옥신 배출특성(I) - 방지시설의 영향 -)

  • Kim, Jin-Beom;Lee, Woo-Keun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.10
    • /
    • pp.1817-1824
    • /
    • 2000
  • This study is carried out to investigate the discharge characteristics of PCDD/Fs from municipal solid waste(MSW) incinerator, According to the results measured at several air pollution control devices(APCDs), the largest amount of polychlorinated dibenzo-p-dioxins/dibenzofurans(PCDD/Fs) are found at selective catalytic reduction (SCR) inlet. Therefore, it concludes that the electrostatic precipitator(EP) provides the appropriate condition for the formation of PCDD/Fs. The concentration of PCDD/Fs shows a large difference with the season. The concentration of PCDD/Fs in winter is higher than that of autumn, which suggests that the formation of PCDD/Fs is affected by the MSW components and the operation condition of municipal solid waste incinerator(MSWI).

  • PDF

A study on power source characteristic of a dust collector for power factor compensating (역률보상형 전기집진기 전원장치 특성연구)

  • Lee, Dong-Gil;Hong, Ji-Tae;Kim, Ho-Sung;Son, Min-Kyu;Lee, Kyoung-Jun;Kim, Jong-Rak;Kim, Hee-Jea
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.1326-1327
    • /
    • 2008
  • Recently, the air pollution is supposed is to be the most serious environmental problem. Therefore, a small air cleaner is asked to make comfortable indoor environment for the moderns who have frequent indoor activity. In this study, without generating of the second pollution source, dust in the air and harmful microorganisms can be removed by the electric dust collecting technology which has high reliability and efficiency to be able to remove the impurities even though it is just 0.01${\mu}m$. Accordingly, power sources of the dust collector use, it is not inefficiency and offering to dust collector unstable. In order to overcome the point at issue, a this study, for power factor compensating use the PFC circuit, for removing the noise use EMI filter and for generating the hight voltage use the Cockcroft Walton Circuit. And we study power source on characteristic and improvement.

  • PDF

A study on the optimization design of air current injection system to improve bag-filter dedusting performance (여과집진기의 탈진 능력 향상을 위한 기류 분사 시스템 최적화 설계에 관한 연구)

  • Jung, Yu-Jin;Hong, Sung-Gil;Jung, Jong-Hyeon;Lim, Ki-Hyuk;Kim, Jin-Uk;Shon, Byung-Hyun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2011.12a
    • /
    • pp.262-265
    • /
    • 2011
  • 본 연구는 탈진 기류 분사 시스템의 최적화 설계에 관한 기초 연구의 일환으로 전산유체역학(CFD)을 이용하여 일반 블로우 튜브와 단순 벤츄리 조합의 충격 기류(Pulse air jet) 방식의 탈진 장치에 대한 탈진 성능과 벤츄리 입구에 기류 유도용 구조물을 설치한 경우의 탈진 성능을 비교하였다. 각 Case별로 벤츄리 내부로 유입되는 탈진 공기량을 예측한 결과, case 2의 벤츄리 형상 개조시 case 1 보다 벤츄리로 유입되는 탈진 공기량이 약 20% 증폭되는 것으로 나타났다. 또한 필터백 표면에서의 탈진 기류 전달 분포를 예측한 결과, 모든 case가 필터백의 국한된 영역으로 탈진 기류가 집중됨을 알 수 있었다. 또한, case 2의 경우가 case 1보다 오히려 탈진 기류의 전달 수준이 불량함을 알 수 있다. 이는 case 2의 경우 벤츄리 입구에 기류 유도용 구조물을 설치한 것이 탈진 공기량을 증폭시키는데에는 도움이 되나, 오히려 벤츄리 내부로 유입된 탈진 기류의 직진성을 보완하여 필터백 내부에서 탈진 기류의 확장을 방해하기 때문인 것으로 판단된다.

  • PDF

Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance (간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측)

  • Jeong-Sam Son;Yong-Hyun Chung;Jeong-Min Suh
    • Journal of Environmental Science International
    • /
    • v.32 no.11
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.