• Title/Summary/Keyword: 질량비 변화

Search Result 371, Processing Time 0.024 seconds

Long-term Trends of the Concentrations of Mass and Chemical Composition in PM2.5 over Seoul (서울시 대기 중 초미세먼지 (PM2.5) 질량과 화학성분 농도의 장기 변동 추이)

  • Han, Sang Hee;Kim, Yong Pyo
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.31 no.2
    • /
    • pp.143-156
    • /
    • 2015
  • The literature data of the mass concentrations of TSP, $PM_{10}$, and $PM_{2.5}$, and chemical composition of $PM_{2.5}$ (sulfate, nitrate, ammonium, OC, and EC) from 1985 and 2013 at Seoul were collected and the temporal trends were discussed in relation with the policy directions. Generally, the mass concentrations of TSP, $PM_{10}$, and $PM_{2.5}$ at Seoul have showed decreasing trends. However, it is not clear what might be the major reason(s) for the trends. The concentrations of ionic component in $PM_{2.5}$ showed different trends, sulfate being reduced during the 1990s but no trend during the 2000s. The concentrations of nitrate and ammonium were increasing during the 2000s. The concentrations of OC show no apparent trend while that of EC decreased. Further policy directions are suggested based on the temporal trends of the chemical composition in $PM_{2.5}$.

Evaluation of Proper Image Acquisition Time by Change of Infusion dose in PET/CT (PET/CT 검사에서 주입선량의 변화에 따른 적정한 영상획득시간의 평가)

  • Kim, Chang Hyeon;Lee, Hyun Kuk;Song, Chi Ok;Lee, Gi Heun
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.2
    • /
    • pp.22-27
    • /
    • 2014
  • Purpose There is the recent PET/CT scan in tendency that use low dose to reduce patient's exposure along with development of equipments. We diminished $^{18}F$-FDG dose of patient to reduce patient's exposure after setting up GE Discovery 690 PET/CT scanner (GE Healthcare, Milwaukee, USA) establishment at this hospital in 2011. Accordingly, We evaluate acquisition time per proper bed by change of infusion dose to maintain quality of image of PET/CT scanner. Materials and Methods We inserted Air, Teflon, hot cylinder in NEMA NU2-1994 phantom and maintained radioactivity concentration based on the ratio 4:1 of hot cylinder and back ground activity and increased hot cylinder's concentration to 3, 4.3, 5.5, 6.7 MBq/kg, after acquisition image as increase acquisition time per bed to 30 seconds, 1 minute, 1 minute 30 seconds, 2 minute, 2 minutes 30 seconds, 3 minutes, 3 minutes 30 seconds, 4 minutes, 4 minutes 30 seconds, 5 minutes, 5 minutes 30 seconds, 10 minutes, 20 minutes, and 30 minutes, ROI was set up on hot cylinder and back radioactivity region. We computated standard deviation of Signal to Noise Ratio (SNR) and BKG (Background), compared with hot cylinder's concentration and change by acquisition time per bed, after measured Standard Uptake Value maximum ($SUV_{max}$). Also, we compared each standard deviation of $SUV_{max}$, SNR, BKG following in change of inspection waiting time (15minutes and 1 hour) by using 4.3 MBq phantom. Results The radioactive concentration per unit mass was increased to 3, 4.3, 5.5, 6.7 MBqs. And when we increased time/bed of each concentration from 1 minute 30 seconds to 30 minutes, we found that the $SUV_{max}$ of hot cylinder acquisition time per bed changed seriously according to each radioactive concentration in up to 18.3 to at least 7.3 from 30 seconds to 2 minutes. On the other side, that displayed changelessly at least 5.6 in up to 8 from 2 minutes 30 seconds to 30 minutes. SNR by radioactive change per unit mass was fixed to up to 0.49 in at least 0.41 in 3 MBqs and accroding as acquisition time per bed increased, rose to up to 0.59, 0.54 in each at least 0.23, 0.39 in 4.3 MBqs and in 5.5 MBqs. It was high to up to 0.59 from 30 seconds in radioactivity concentration 6.7 MBqs, but kept fixed from 0.43 to 0.53. Standard deviation of BKG (Background) was low from 0.38 to 0.06 in 3 MBqs and from 2 minutes 30 seconds after, low from 0.38 to 0 in 4.3 MBqs and 5.5 MBqs from 1 minute 30 seconds after, low from 0.33 to 0.05 in 6.7 MBqs at all section from 30 seconds to 30 minutes. In result that was changed the inspection waiting time to 15 minutes and 1 hour by 4.3 MBq phantoms, $SUV_{max}$ represented each other fixed values from 2 minutes 30 seconds of acquisition time per bed and SNR shown similar values from 1 minute 30 seconds. Conclusion As shown in the above, when we increased radioactive concentration per unit mass by 3, 4.3, 5.5, 6.7 MBqs, the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the same way, in the change of inspection waiting time (15 minutes and 1 hour), we could find that the values of $SUV_{max}$ and SNR was kept changelessly each other more than 2 minutes 30 seconds of acquisition time per bed. In the result of this NEMA NU2-1994 phantom experiment, we found that the minimum acquisition time per bed was 2 minutes 30 seconds for evaluating values of fixed $SUV_{max}$ and SNR even in change of inserting radioactive concentration. However, this acquisition time can be different according to features and qualities of equipment.

  • PDF

Characteristics of Mass Transport Depending on the Feature of Tidal Creek at Han River Estuary, Gyeong-gi Bay, South Korea (경기만 염하수로에서의 비정규 격자 수치모델링을 통한 조간대 조수로의 고려에 따른 Mass Transport 특성)

  • Kim, Minha;Woo, Seung-Buhm
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.2
    • /
    • pp.41-51
    • /
    • 2013
  • The tidal creek dependent mass transport characteristic in Gyeong-Gi Bay (west coast of Korea) was studied using field measured data and numerical model. Gyeong-Gi Bay consists of 3 main tidal channels and contains a well-developed vast tidal flat. This region is famous for its large tidal difference and strong current. We aim to study the effect of tidal creek in the tidal flat on the mass exchange between the estuary and the ocean. For numerical application, the application of unstructured grid feature is essential, since the tidal creek has complicated shape and form. For this purpose, the FVCOM is applied to the study area and simulation is performed for 2 different cases. In case A, geographic characteristics of the tidal creek is ignored in the numerical grid and in case B, the tidal creek are constructed using unstructured grid. And these 2 cases are compared with the field measured cross-channel mass transport data. The cross-channel mass transport at the Yeomha waterway mouth and Incheon harbor was measured in June, 9~10 (Spring tide) and 17~18 (Neap tide), 2009. CTD casting and ADCP cross-channel transect was conducted 13 times in one tidal cycle. The observation data analysis results showed that mass transport has characteristic of the ebb dominance Line 1 (Yeomha waterway mouth), on the other hand, a flood dominant characteristic is shown in Line 2 (Incheon harbor front). By comparing the numerical model (case A & B) with observation data, we found that the case B results show much better agreement with measurement data than case A. It is showed that the geographic feature of tidal creek should be considered in grid design of numerical model in order to understand the mass transport characteristics over large tidal flat area.

Gas Permeation Properties of $CO_2$ Through Poly(ethylene Glycol) Diacrylate/Poly(Propylene Glycol) Diacrylate Membrane (Poly(ethylene glycol)diacrylate/poly(propylene glycol)diacrylate 막의 이산화탄소 기체 투과특성에 관한 연구)

  • Rhim Ji Won;Nam Sang Yong;Lee Sun Yong;Yun Tae Il
    • Membrane Journal
    • /
    • v.14 no.3
    • /
    • pp.250-257
    • /
    • 2004
  • PEG(poly(ethylene glycol)) acrylate/PPG(poly(propylene glycol)) acrylate (PEG/PPG) was prepared using UV induced photopolymerization method to investigate gas permeation properties of the membrane. The effect of PPG content on the solubility, diffusivity, and permeability of $CO_2$, $O_2$, and $N_2$ in PEG/PPG membrane is reported at $25^{\circ}C$ and $35^{\circ}C$. PEG/PPG (9:1) membrane exhibits $CO_2$ permeability coefficient of 28.9 barrer and $CO_2$/$N_2$ pure gas selectivity of 57.9 at $25^{\circ}C$. Permeability coefficient of increased with increasing with PPG content in the membrane. PEG/PPG (5:5) membrane shows $CO_2$ permeability coefficient of 78.9 barrer and $CO_2$/$N_2$ pure gas selectivity of 33.2 at $25^{\circ}C$.

Characterization of Layered Double Hydroxides(Mg-Al-$CO_3$ systems) and Rehydration Reaction of Their Calcined Products in Aqueous Chromate Solution (층상이중수산화물(Mg-Al-$CO_3$ 체계)의 물리 · 화학적 특성규명 및 소성된 시료의 크롬산이온 수용액에서 재수화반응)

  • Rhee, Seog Woo;Kang, Mun-Ja;Moon, Hichung
    • Journal of the Korean Chemical Society
    • /
    • v.39 no.8
    • /
    • pp.627-634
    • /
    • 1995
  • Layered double hydroxides ($Mg-Al-CO_3$ systems, LDH), which are hydrotalcite-like anionic clay minerals, having different $Mg^{2+}\;to\;Al^{3+}$ ratio were synthesized by coprecipitation method. The subsequent products were characterized by the following methods; elemental analysis, X-ray powder diffraction, thermal analysis (DSC and TGA), FT-IR and $^{27}$Al-MAS NMR. X-ray powder patterns showed that the products formed were layered structure materials. Two heat absorption peaks were observed around 20 ∼280$^{\circ}C$ (surface water and interlayer water) and 280∼500$^{\circ}C$ (water from lattice hydroxide and carbon dioxide from interlayer carbonate) in DSC diagrams, and they were quantitatively analyzed by TGA diagrams (in case LDH4 16.2% and 28.6% respectively). FT-IR spectra indicate that the interlayer carbonate ions occupied symmetrical sites between two adjacent layers in a parallel direction. $^{27}$Al-MAS NMR spectra show only single resonance (8.6 ppm) of the octahedrally coordinated aluminum similar magnesium. When LDH4 was calcined at 560$^{\circ}C$ for 3 hours in air, its layered structure was destroyed giving a mixed metal oxide. However it readily became rehydrated in aqueous chromate solution to its original structure.

  • PDF

A Study on the Variation of the Surface and Groundwater Flow System Related to the Tunnel Excavation in DONGHAE Mine Area (II) - Hydrogeochemical Consideration (동해신광산 터널굴착공사와 관련된 지표수 및 지하수의 유동변화에 대한 조사연구 (II)-수리지구화학적 고찰)

  • 전효택;이희근;이종운;이대혁;류동우;오석영
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.4 no.1
    • /
    • pp.27-40
    • /
    • 1997
  • The hydrogeochemical study on the 15 natural waters was carried out in the vicinity of tunnel excavation site of Donghae largely composed of granite and limestone. The water samples can be classified based on their chemical characteristics into two groups; waters draining in the granitic region(group 1) and the limestone region(group 2). This classification was also confirmed by statistical examination through cluster analysis, and the tunnel seepage waters collected at the same site appear to be included in group 1 and 2 by their sampling period, respectively. According to factor analysis, the waters of group 1 art mainly represented by the weathering of plagioclase to kaolinite and those of group 2 are characterized by the dissolution of calcite. Different properties of the tunnel seepage waters are thought to be resulted from the effective waterproofing processes conducted during the sampling interval to the surface and subsurface leakage zones at the granitic region, which contributed to the change of groundwater flow system. However both the tunnel seepage waters seem to have thermodynamically interacted with rock-forming minerals in their wallrocks. The mixing ratio of the waters from two groups and water-rock interactions are evaluated quantitatively for the tunnel seepage waters through the mass balance approach, and the results are identical with the previous conclusions in this study.

  • PDF

Color revelation characteristics of color mortar using iron oxide and carbon black (산화철과 카본블랙을 사용한 컬러 모르터르의 색상발현 특성)

  • Seok, Hwa-Song;Hong, Chang-Woo
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.30 no.4
    • /
    • pp.156-161
    • /
    • 2020
  • Recently, as there has been growing demand for aesthetic quality in structural materials, the development of excellent color cement concrete having good coloration properties has become a requirement. This study is designed to analyze the basic physical properties of mortar and the properties of keeping the coloration under an ultraviolet ray accelerated weathering test environment according to changes in the mixing ratio between carbon black and iron oxide used as colorants. The test results show that the use of carbon black and iron oxide reduces the initial flow by 6.3~17.2 % and the air content by 3.5~31.5 % but increases the unit volume weight by 3.4~5.5 %, compared to ordinary Portland cement (OPC). In addition, the study shows that the addition of iron oxide increases the self drying shrinkage. So, caution needs to be taken on the workability of the concrete. The brightness value L represented by black showed the most excellent black colour when carbon black 3 % and iron oxide 5 % are added. According to UV accelerated weatherproof test, the brightness value L was found to increase in all experiment specimens by 4.28~11.97 %, and the color change by UV was found to be higher for the case where carbon black colorant was not used. Therefore, in terms of color revelation characteristics, the case using carbon black 3 % and iron oxide 5 % was found to show the best black color.

Enzymatically Modified Isoquercitrin Attenuates High-Fat Diet-Induced Obesity (효소 처리된 Isoquercitrin이 고지방식이에 의해 비만이 유도된 마우스의 체중감소에 미치는 영향)

  • Min, Yeojin;Park, Taesun
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.4
    • /
    • pp.474-483
    • /
    • 2016
  • Enzymatically modified isoquercitrin (EMIQ) is a mixture of quercetin glycodsides consisting of isoquercitrin and its ${\alpha}-glucosylated$ derivatives containing one to seven additional linear glucose moieties. The aim of this study was to assess whether or not EMIQ attenuates high-fat diet (HFD)-induced body weight gain and changes in plasma indices of obesity in mice. Male C57BL/6N mice were fed chow diet, HFD, and HFD containing 1.2% EMIQ for 10 weeks. EMIQ significantly (P<0.05) reduced body weight gain (-21%), total visceral fat-pad weights (-31%), and plasma levels of triglycerides (-17%), total cholesterol (-19%), and free fatty acids (-26%) in HFD-fed mice. EMIQ significantly increased protein kinase A (PKA) expression in the epididymal adipose tissue of HFD-fed mice. Expression of adipogenesis-related genes significantly decreased, whereas expression of fatty acid oxidation-related and thermogenesis-related genes increased in epididymal adipose tissue of EMIQ-fed mice compared with HFD-fed mice. These results suggest that the protective effects of EMIQ against HFD-induced adiposity in mice appear to be associated with PKA-mediated signaling cascades involved in adipogenesis, fatty acid oxidation, and thermogenesis in adipose tissue.

IUE SPECTRA OF SEYEERT 1 GALAXY NGC 7469-BLR CHARACTERISTICS OF NGC 7469 (SEYFERT 1 은하 NGC 7469의 IUE SPECTRA-NGC 7469 BLR의 물리적 특성)

  • Son, Dong-Hoon;Hyung, Siek
    • Journal of Astronomy and Space Sciences
    • /
    • v.22 no.3
    • /
    • pp.187-196
    • /
    • 2005
  • From the line ratios of Si III] 1892 to C III] 1909 (Feibelman & Aller 1987), we estimated the BLR electron densities and their changes of Seyfert 1 galaxy NGC 7469 using IUE spectra observed from June 11 to July 29, 1996 (Wanders et al. 1997). We separated blended Si III] and C III] lines using the STARLINK/DIPSO and measured their fluxes within the error of $12.4\%\;and\;6.6\%,$ respectively. Electron density fluctuated from $10^{9.69}\;to\;10^{10.93}$ during about two month period, i.e. 17.3 times density variation within 50 days. We also derived time delays from UV emission line variations .elative to the continuum $(at\;1315{\AA}):$ 2 days for C IV, 4 days for C III], 8 days for Si III]. This suggests that their stratified UV line emission regions are at 0.002 pc, 0.004 pc and 0.006 pc, respectively, from the central region. Based on the BLR sizes and their rotation velocities deduced from the line profiles, we estimate the central black hole mass as about $10^6M_{\odot}$

One-dimensional Hydraulic Modeling of Open Channel Flow Using the Riemann Approximate Solver I : Model Development (Riemann 해법을 이용한 1차원 개수로 수리해석Ⅰ: 모형 개발)

  • Kim, Ji-Sung;Han, Kun-Yeun
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.761-772
    • /
    • 2008
  • The object of this study is to develop the model that solves the numerically difficult problems in hydraulic engineering and to demonstrate the applicability of this model by means of various test examples, such as, verification in the gradually varied unsteady condition, three steady flow problems with the change of bottom slope with exact solution, and frictional bed with analytical solution. The governing equation of this model is the integral form of the Saint-Venant equation satisfying the conservation laws, and finite volume method with the Riemann solver is used. The evaluation of the mass and momentum flux with the HLL Riemann approximate solver is executed. MUSCL-Hancock scheme is used to achieve the second order accuracy in space and time. This study introduce the new and simple technique to discretize the source terms of gravity and hydrostatic pressure force due to longitudinal width variation for the balance of quantity between nonlinear flux and source terms. The results show that the developed model's implementation is accurate, robust and highly stable in various flow conditions with source terms, and this model is reliable for one-dimensional applications in hydraulic engineering.