• Title/Summary/Keyword: 질량변화

Search Result 997, Processing Time 0.028 seconds

Mass Loss and Air Entrainment Rate of Whirl Fire by Height of Fire Source (화점높이 변화에 따른 Whirl Fire의 질량감소 및 공기유입속도)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.25 no.2
    • /
    • pp.126-131
    • /
    • 2011
  • This study is intended to understand mass loss rate and air entrainment rate of the whirl fire by height of fire source. Liquid fuels were methanol and n-Heptane which are used in many studies of whirl fire. Size of vessel was 100 mm ${\times}$ 100 mm ${\times}$ 50 mm and the vessel was made by stainless steel. When height of fire source changed from 0 cm to 30 cm, air entrainment rate showed the fastest in case of 0 cm. And in the same height of fire source, average and maximum air entrainment rate showed the fastest in 30 cm of anemometer. From the results of whirl fire for methanol and n-Heptane, mass loss rate and air entrainment rate of n-Heptane was found to faster 1.33 to 1.58 times and 4.38 to 5.44 times compared with methanol, respectively. Consequently, mass loss rate and air entrainment rate in whirl fire was able to identified decrease as height of fire source increases and the higher the heating value, increases the that's value.

Mass Flow Rate Measurement of Pulsating Flow in a Twin-Scroll Turbocharger (트윈스크롤 터보과급기에서 맥동유동의 질량유량 측정)

  • Chung, Jin-Eun;Jeon, Se-Hun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.723-729
    • /
    • 2019
  • Turbochargers are an effective device to reduce the fuel consumption. In this study, the mass flow rate of pulsating flow in the twin-scroll turbocharger for the gasoline engine of passenger vehicles was measured. Pulsating flow was achieved using a pulse generator and the mass flow rate of the unsteady pulsating flow was analyzed by comparing it with those of the steady flow. The pulse generator consisted of a rotating upper plate and a fixed lower plate. To measure the mass flow rate of unsteady flow, the orifice flow meter equipped with the difference pressure transducer was used. To analyze the low speed performance of the turbocharger, the measurement was carried out in the speed of turbocharger from 60,000rpm to 100,000rpm. The mass flow parameters of the unsteady pulsating flow showed a large difference compared to those of the steady flow. Those of the unsteady flow showed the hysteresis loop surrounding the mass flow parameters of the steady flow and the maximum variation of the mass flow parameters were 5.0 times those of the steady flow. This phenomenon is the result of the filling and emptying the turbine volute space due to pulsating flow.

A Study on Determination of Boron Makeup Flow Rate During the Load Follow Operation (부하추종 운전시 보론 보충 수량 결정에 관한 연구)

  • Song, Yong-Mann;Lee, Un-Chul;Chung, Chang-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.20 no.1
    • /
    • pp.1-8
    • /
    • 1988
  • During power plant operation, the flow rate from the CVCS makeup system is estimated using the continuity equation and mass balance equation, when the primary loop boron concentration change is required due to the power transient. For this purpose, primary loop, pressurizer and VCT(volume control tank)(in CVCS) are modeled by three control volumes which contain each mass and boron concentration. Connecting pipes between primary loop, pressurizer and CVCS are also modeled by time delay. Calculation for 14-2-6-2 (power 100-50-100) load follow case (at EOL, for KNU 7) is made using these models.

  • PDF

Experimental Study on Characteristics of Steam Condensation in a Sub-cooled Water Pool (과냉각수조에서 증기응축 특성에 관한 실험적 연구)

  • Kim, Hwan-Yeol;Cho, Seok;Song, Chul-Hwa;Chung, Moon-Ki;Choi, Sang-Min
    • Journal of Energy Engineering
    • /
    • v.8 no.2
    • /
    • pp.298-308
    • /
    • 1999
  • Experimental study on characteristics of direct contact condensation of steam discharged into a sub-cooled water pool has been performed using five different sizes of horizontal nozzle over a wide range of steam mass fluxes and pool temperatures. Steam condensation phenomena have been observed visually and by taking pictures of steam jets using a high speed video camera. Two different steam jet shapes such as ellipsoidal shape and conical shape were typically observed for a stable steam jet, depending on the steam mass flux and pool temperature. The steam jet expansion ratio and the steam jet length as well as the condensation heat transfer coefficients were determined. The effect of steam mass flux, pool temperature, and nozzle diameter on these parameters were also discussed. Empirical correlations for the steam jet lengths and the condensation heat transfer coefficients as a function of steam mass flux and condensation driving potential were established. The axial and radial temperature distributions in steam jet and in surrounding water were measured. The effect of steam mass flux, pool temperature, and nozzle diameter were also discussed. The condensation regime map, which consists of six regimes such as chugging, transient chugging, condensation oscillation, stable condensation, bubble condensation oscillation, and intermittent oscillation condensation, were established. In addition, the dynamic pressures at the pool wall were measured. The close relation of dynamic pressure and steam condensation mode, which is also dependent on steam mass flux and pool temperature, was found.

  • PDF

Application of MR Damper for Vibration Control of Floor Slab (바닥판 구조물의 진동제어를 위한 MR 감쇠기의 적용)

  • Kim, Gee-Cheol;Kwak, Chul-Seung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.3 s.21
    • /
    • pp.59-67
    • /
    • 2006
  • A conventional passive TMD is only effective when it is tuned properly. In many practical applications, inevitable off-tuning of a TMD occurs because the mass in a building floor could change by moving furnishings, people gathering, etc. when TMDs are offtuned, TMDs their effectiveness is sharply reduced. Moreover, the off-tuned nTMDs can excessively amplify the vibration levels of the primary structures. This paper discusses the application of a new class of MR damper, for the reduction of floor vibrations due to machine and human movements. The STMD introduced uses a MR damper called to semi-active damper to achieve reduction in the floor vibration. Here, the STMD and the groundhook algorithm are applied to a single degree of freedom system representative of building floors. The performance or the STMD is compared to that or the equivalent passive TMD. In addition, the effects of off-tuning due to variations in the mass of the floor system. Comparison of the results demonstrates the efficiency and robustness or STMD with respect to equivalent TMD.

  • PDF

V345 Cas의 주기변화와 광도곡선 분석

  • Jeong, Min-Ji;Kim, Cheon-Hwi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.37 no.2
    • /
    • pp.142.2-142.2
    • /
    • 2012
  • Hoffmeister(1943)에 의해 변광성으로 발견된 V345 Cas (2MASS J23083986+5406545, ${\alpha}$(2000.0)=23h08m39.86s & ${\delta}(2000.0)=+54^{\circ}06^{\prime}54.6^{\prime\prime}$)는 B 필터에서 13.1~14.2의 광도 변화를 보이는 것으로 알려진 별이다. 우리는 레몬산 천문대(LOAO)에서 2007년과 2008년에 걸쳐 총 22일간 V345 Cas의 BVRI CCD 측광관측을 수행하여, 처음으로 V345 Cas의 년도 별 전체 광도곡선을 완성하였다. 우리의 관측 자료와 Super WASP에서 공개한 자료를 이용하여 각각 7개의 극심시각을 산출하였다. 우리가 결정한 극심시각을 포함하여 여러 문헌에서 수집한 총 68개의 극심시각을 이용하여 V345 Cas의 주기 분석을 수행하였다. 그 결과, V345 Cas의 궤도주기는 포물선 모양의 영년변화와 함께 약 30년의 규칙적인 변화를 겪고 있음을 발견하였다. 규칙적인 변화를 제3천체에 의한 광시간 효과로 가정하여 관측된 극심시각에 잘 맞는 광시간 궤도 해를 산출한 결과, 영년주기가 증가하는 경우와 감소하는 경우에 대해, 각각 29.0년과 39.7년 주기를 갖는 두 개의 광시간 궤도 해가 가능하다. 이러한 모호성을 해결하기 위해서 앞으로의 극심시각 관측이 중요하다. 2007년과 2008년 BVRI 광도곡선들은 부극심을 기준으로 좌우가 거의 대칭이며, 1년 사이에 특기할 만한 광도변화를 보이지 않았다. 우리는 이 광도곡선들을 Wilson-Devinney 쌍성 모델을 이용하여 분석하여, V345 Cas의 측광학적 해를 처음으로 산출하였다. 우리가 구한 해에 의하면, 약 88도의 궤도경사각에 두 성분별의 질량비가 약 0.5인 V345 Cas는 질량과 표면 온도가 큰 주성과 로쉬 로브를 채우고 있는 반성으로 구성된 준 분리형 식쌍성계이다.

  • PDF

PERIOD CHANCE OF THE CONTACT BINARY AH Tauri (접촉쌍성 AH Tauri의 공전주기 변화)

  • Lee, Dong-Joo;Lee, Chung-Uk;Lee, Jae-Woo;Kim, Seung-Lee;Oh, Kyu-Dong;Kim, Chun-Hwey
    • Journal of Astronomy and Space Sciences
    • /
    • v.21 no.4
    • /
    • pp.283-294
    • /
    • 2004
  • New BV RI photometric observations of the contact binary AH Tau were performed with the 61 cm reflector and a 2K CCD camera at the Sobaeksan Optical Astronomy Observatory during seven nights from September to December, 2001. A total of 144 times of minima observed up to date, including three times of minima obtained from our observation, were analyzed. It is found that the orbital period of AH Tau has varied in a cyclic way superposed on a secular period decrease. The rate of the secular period decrease is calculated to be $1^s$ .04 per century, implying that a mass of about $3.8{\times}10^{-8}M{\odot}/yr$ from the more massive primary flows into the secondary if a conservative mass transfer is assumed. Assuming that the sinusoidal period variation is produced by a light-time effect due to an unseen third body, the resultant semi-amplitude, period, and eccentricity for the deduced light-time orbit are obtained as 35.4 years, 0.014 day and 0.52, respectively. The mass of the third-body is calculated as a tout $0.24M{\odot}$ when the third body is assumed to be coplanar with AH Tau system.

A Study on the Engine Mounting System of the 4WD Vehicle by Experimental Modal Analysis (실험적 Mode 해석을 통한 4WD 자동차의 엔진마운트에 관한 연구)

  • 사종성;김광식
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1991.04a
    • /
    • pp.139-144
    • /
    • 1991
  • 4WD자동차의 엔진마운트 설계기법의 정리 및 실제차량의 실험적 mode 해 석을 통해 다음과 같은 결론을 얻었다. 1. 4WD자동차의 엔진마운트 설계 개념을 체계화시키고, 이를 실제차량에 대 해서 실험적 mode해석을 해본 결과 잘 일치함을 확인하였다. 2. power transmission system에 부가되는 장치(front propeller shaft)의 영 향을 검토한바, frequency shift현상이 발생함을 확인하였다. 이러한 영향은 이들 부가장치들의 질량증가 및 관성모멘트의 변화로 기인되며, 질량의 증가 보다는 관성모멘트의 영향이 상대적으로 크리라 판단된다.

  • PDF

Analysis of Mass Position Detection Using the Change of the Structural Dynamic Characteristics (동특성 변화로부터 구조물의 변경질량 위치 해석)

  • 이정윤
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.13 no.2
    • /
    • pp.120-126
    • /
    • 2004
  • This study proposed the analysis of mass position detection due to the change of the mass and strifeless of structure by using the original and modified dynamic characteristics. The method is applied to examples of the cantilevers beam and the 3 degrees of freedom system by modifying the mass. The predicted detection of the mass positions and magnitudes are in good agrement with the present study from the structural reanalysis using the modified mass.

Quantity of Ice Slurry in Cooled Tube by Continuous Ice Making using Organic Water Solution (유기수용액에 의한 냉각관내 연속제빙시의 제빙량)

  • ;Hidetoshi Miura;Akihiko Horibe;Hideo Inaba
    • Journal of Energy Engineering
    • /
    • v.9 no.3
    • /
    • pp.221-227
    • /
    • 2000
  • 본 논문은 냉각된 원관내에서 유동하는 프로필렌글리콜 수용액의 제빙에 관하여 실험한 것이다. 실험은 수용액의 질량농도, 수용액의 유속, 관벽의 온도, 펌프의 압력 등을 변화시키면서 행하였다. 그 결과 관내에서의 제빙량은 프로필렌글리콜 수용액의 관내유속, 벽면과 냉각도 및 수용액의 농도에 영향을 받고 있었고, 수용액의 질량농도가 낮을수록 또 시험수용액의 유속이 빠를수록 관내에서의 제빙량은 증가하는 경향을 띄었다. 그리고 관내제빙율에 영향을 미치는 인자들의 효과를 검토하여 관내제빙율에 관한 우차원식을 얻었다.

  • PDF