• Title/Summary/Keyword: 진동 인텐시티

Search Result 100, Processing Time 0.028 seconds

Noise, vibration Characteristic Identification and Noise Control of Indoor Air-Conditioner's Cabinet using Operational Deflection Shape (운행 중 변형형상을 이용한 에어컨 실내기 캐비닛의 소음/진동 특성 파악 및 제어)

  • Lee, Seong-Jin;Oh, Jae-Eung;Lee, Jung-Youn;Kang, Tae-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.830-833
    • /
    • 2004
  • An indoor package air-conditioner (PAC) has complex noise sources such as motor noise and fluid noise caused by the fan motor, heat transfer and shroud. Sound intensity techniques and ODS(Operational deflection shape) techniques are applied to identify the noise characteristics of an indoor air-conditioner's cabinet. The sound intensity is used to visualize the noise source locations. and the ODS to visualize the vibration pattern and to obtain the dynamic characteristics of the noise source. Acoustic intensity and operational deflection distribution are obtained in space domains as well as frequency domains. Using the visual information of source locations and its dynamic characteristics, the damping patch is applied to reduce structure borne noise in the cabinet. As a result, the noise emitted by the cabinet is reduced by 5dB.

  • PDF

A Study on the Noise Reduction of the Engine Cooing Fan of a Express Bus by Modification of Design Parameters (설계 파라미터 변경에 의한 고속 버스용 엔진 냉각 홴의 저소음화 연구)

  • 이유엽;조용구;이충휘;오재응
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.13 no.4
    • /
    • pp.258-265
    • /
    • 2003
  • This paper suggests the noise reduction method of the engine cooling fan. The fan noise contribution to the OASPL of engine room was estimated and the noise source was identified for the rotating fan by sound intensity method. And the program for Predicting the noise spectrum of axial flow fan was also developed. The radiated acoustic pressure is expressed in terms of discrete frequency noise Peaks at BPF and its harmonics and the line spectrum at the broad band by the proposed noise generation mechanisms. In this Paper, it Is shown that the comparison of the measured and calculated noise spectra of fan validates the noise predicting program. And this paper presents the characteristics of the fan noise in order to modify the design parameters. Accordingly, the design parameters were determined for the noise reduction of the fan.

Active Control of External Noise Radiated From Duct Using Sound Intensity (음향 인텐시티를 이용한 관 외부 방사 소음의 능동 제어)

  • 강성우;김양한
    • Journal of KSNVE
    • /
    • v.7 no.3
    • /
    • pp.427-437
    • /
    • 1997
  • Mean active intensity based active control for the cancellation of radiated noise out of the duct exit is studied. The active intensity control strategy is drerived based on the relation of the exterior sound field out of the duct termination and interior sound field of the duct. One of the characteristics of this control strategy is that the control performance can be maintained regardless of the sensor loction, compared with the conventional local pressure control methods at either interior downstream or exterior field positions. It is also suggested that the digital filtering for the active intensity control can be achieved by time-domain filtered-x LMP (Lest-Mean-Product) adaptive algorithm. Experiments for an open-ended duct are performed to compare the active intensity control performance with conventional pressure control one. Active control experiment of local sound pressure is conducted by widely used filtered-x LMS adaptive Algorithm and active intensity control implementaion uses the derived filter d-x LMP algorithm. It is shown that the exterior sound fileds was much better observable by sensing of the active intensity than by just sound pressure. It is also demonstrated that the global control performance of external field by acoustic intensity is superior to the conventional sound pressure control performance.

  • PDF

Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity (음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어)

  • Kang, Seong-Woo;Han, Yun-Sik;Hwang, Tae-Yeon;Son, Young;Koo, Ja-Choon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF

The measurement and analysis of Regenerative Pump Noise (재생펌프 소음특성의 측정 및 해석에 관한 연구)

  • Kim, Tae-Hoon;Seo, Young-Soo;Jeong, Weui-Bong;Jeong, Ho-Kyeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.1067-1071
    • /
    • 2004
  • In this paper, the characteristic of the regenerative pump is reviewed by the measurement and the analysis. The dominant noise sources are harmonic components of the rotating impeller frequency. The acoustic characteristics and the noise source position at the dump are identified. In order to reduce the high-level peak noise, the interior flow of the pump chamber is analyzed by CFD (Computational Fluid Dynamics). Acoustic pressure is calculated with Ffowscs Williams and Hawkings equation. As the result of the analysis new design of the pump chamber is recommended. The recommended pump is compared with original pump by evaluating the RMS value of a interior static pressure and the sound pressure level. The new pump chamber recommended by analysis results is proved by a process of the measurement. The overall SPL of a recommended pump is reduced about 3 dBA.

  • PDF

A study on the identification of dynamic characteristics of tennis racket by acoustic intensity method (음향 인텐시터법을 이용한 테니스 라켓의 동특성에 관한 연구)

  • 오재응;이유엽;염성하
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.5
    • /
    • pp.601-610
    • /
    • 1986
  • The acoustic intensity in the very near field of a vibrating surface reveals information about the location of sound sources and sinks. A system model of tennis racket was developed from simultaneous measurement of excitation force, surface vibration and the near field sound pressure. The characteristics of structural dynamics were obtained by standard experimental modal analysis techniques while the sound radiation characteristics were determined by estimating the acoustic intensity. In this paper, the information about vibration behviour was obtained by acoustic intensity method and some, experiments for verification were carried out. Close correlation was found between experimentally determined acoustic intensity and vibration mode patterns of the tennis racket.

Analysis of Noise Source for Mold Transformer (몰드변압기의 소음 원인 분석)

  • Choi, W.H.;Kim, W.C.
    • Journal of Power System Engineering
    • /
    • v.4 no.4
    • /
    • pp.59-64
    • /
    • 2000
  • Especially, demands for the noise reduction of mold transformer has been becoming an common issue because it has been used mainly at the residence area such as building and ship. So, this paper investigates the noise source and countermeasure of mold transformer radiated high noise abnormally. The result of impact hammering test for core of transformer ascertains the core resonance by harmonics of line frequency and high noise can be reduced to avoid core resonance by changing torque strength of tie rod. Magnetic field analysis is performed to identify the reason that noise of V-phase is higher than U and W-phase in the normal condition. It is the cause that flux density and magnetic force of V-phase is higher than the other phase respectively.

  • PDF

A Study on Sound Radiation From Infinite Beams Under the Action of Moving Harmonic Point Forces (조화집중이동하중을 받는 무한보에서의 음향방사에 관한 연구)

  • 김병삼;태신호;홍동표
    • The Journal of the Acoustical Society of Korea
    • /
    • v.12 no.4
    • /
    • pp.39-46
    • /
    • 1993
  • 조화집중이동하중을 받는 무한보에서의 음향방사에 대한 연구는 선박, 비행기, 타이어 트레드 밴느 등과 같은 계의 설계시 계의 구조물로부터 발생하는 소음에 대한 해결방안을 제시해 준다. 구조물 표면에 발생하는 음향파워는 svktnqusghks방법을 이용하여 보의 전길이에 분포된 음향 인텐시티를 적분하여 구한다. 보의 표면에서 발생하는 음향파원는 미하수, 장력, 감쇠계수, 기초강성계수, 그리고 파수비에 의해서 결정된다. 각 인자에 따른 음향파워에 대한 정성적인 분석을 수행하기 위해 심프슨 적분방법을 이용하여 수치적분을 하였다. 무한보에 작용하는 유체하중에 3다라 진동에너지가 음향에너지로 변환되는 비율이 달라진다. 밀도가 큰 유체는 등가감쇠로 작용하여 보로부터 방사된 음향에너지는 빠르게 감소된다. 하중의 이동에 의하여 도플러이동효과가 발생하여 무한보의 공진부근에서의 음향파워 파크가 분리되고 보의 기초감쇠의 영향으로 음향에너지는 감소된다.

  • PDF

A Study on the Noise Source Identification of Refrigerator Compressor (냉장고용 압축기 소음원 규명에 관한 연구)

  • O, Jae-Eung;Lee, Chang-Ho;Lee, Myeong-Ryeol;Yeom, Seong-Ha
    • The Journal of the Acoustical Society of Korea
    • /
    • v.6 no.1
    • /
    • pp.48-57
    • /
    • 1987
  • It is well known that the major noise source of Refrigerator is compressor, and due to the tendency of higher quality and more lighting of manufactured goods, the importance of prevention and reduction of a noise is increasing. In this paper, in order to prevent and reduce such a noise, sound pressure level and acoustic intensity are measured for compressor, and the result of these measurements, the noise radiation characteristics of compressor are reconized. And the experimental modal analysis is applied to the compressor to identify the noise sourcce. As the results of this study, we come to know that the spring, which is used to reduce vibration, does not reduce vibration efficiently, and compressor shell and its mounting system effect the noise radiation.

  • PDF

The Design of the Motor Bracket for Reduction of Structure- Borne Noise in Package Air-Conditioner (에어컨의 구조 소음 저감을 위한 실내기 모터 브라켓의 설계)

  • Sim Hyoun-Jin;Lee Sung-Jin;Kang Tae-Ho;Lee Jung-Yoon;Oh Jae-Eung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.2 s.245
    • /
    • pp.202-209
    • /
    • 2006
  • As the economic power is improved and the customer's demand is hard to please, the noise and vibration is the most important yardstick that can determine the quality of the product. Especially, as the airconditioner's demand increase suddenly, the product of quality and the noise is becoming a decisive factor of determining whether purchase the product or not. Therefore, every manufactory is investing a lot of money and research to cut down the unpleasantness induced from noise and vibration. And they are emphasizing their product's difference by advertising a silence very actively. With these reason, the demand of a silent indoor air-conditioner is the essential research filed when the product is develop(:d. In this study, the noise and vibration is visualized in the space and frequency domain by using experimental methods such as operational deflection shape (ODS), modal testing and sound intensity. Also the location of noise source and its characteristic is analyzed in an acoustical point of view to reduce the structure borne noise that come from the fan motor, and the pertinent control method is suggested. Furthermore, the most suitable shape of the motor bracket is suggested by applying FEM and DOE (Design of experiments) in the noise and vibration point a view.