• 제목/요약/키워드: 진동 규명

검색결과 575건 처리시간 0.028초

HDD용 압전형 마이크로엑츄에이터의 동특성 규명 (Dynamic Characterizations of a Piezoelectric Microactuator in Hard Disk Drive)

  • 김철순;김규용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.232-236
    • /
    • 2000
  • To provide model parameters for servo control system design, dynamic characteristics of a piezoelectric microactuator for hard disk drive(HDD) were investigated. At first frequency response characteristics was measured and a second order model was proposed. Here the amplitude dependent dynamic characteristics such as low frequency gain and damping ratio were studied. In addition, the load current and equivalent impedance of the piezoelectric actuator were measured by varying excitation voltage and frequency. At last, the super-harmonic resonance of the piezoelectric actuator was discussed.

  • PDF

구형 압전 변환기의 점대칭 방사모드 진동 특성 (Vibration Characteristics of the Point-symmetric Mode in a Spherical Piezoelectric Transducer)

  • 전한용;김진오
    • 한국음향학회지
    • /
    • 제21권8호
    • /
    • pp.757-765
    • /
    • 2002
  • 본 논문은 해석과 실험을 통하여 구형 압전 변환기의 점대칭 방사모드 진동 특성을 규명하는 것을 목적으로 한다. 반경 방향 좌표와 시간의 함수인 반경 방향 변위와 전기 퍼텐셜로 표현되는 지배방정식을 구성한다. 역학적 경계조건과 전기적 경계조건을 적용하여 방사 진동의 특성방정식을 유도한다. 이 식을 이용하여 압전 고유진동수를 계산하고, 그 결과를 측정 결과와 비교한다. 수치계산을 통하여 압전 공진과 탄성 공진의 차이, 구형 압전체의 반경 및 두께에 따른 고유진동수 등을 고찰한다. 그 결과 1차 방사모드의 고유진동수 크기는 압전현상으로 인해 작아지며 구형의 곡률 반지름이 커짐에 따라 지수함수적으로 작아지는 것을 알게 되었다.

500 MW급 석탄화력발전소 증기터빈축 이상진동의 해결방안 (Abnormal Vibration of the Steam Turbine Shaft in 500 MW Class Coal-fired Power Plants)

  • 안광민;유호선
    • 플랜트 저널
    • /
    • 제13권1호
    • /
    • pp.30-36
    • /
    • 2017
  • 본 연구에서는 500 MW급 석탄화력발전소 기동 중 고압 및 중압 증기터빈축 양단 베어링에서 발생한 이상진동 현상의 원인을 규명하고 해결방안을 모색하기 위하여 알려진 이론에 근거하여 분석을 수행하였다. 주파수, 진폭 및 위상각 분석결과 접촉에 의해 발생하는 진동의 전형적인 특성이 나타나 이상진동의 원인을 접촉으로 판단하였고 증기터빈을 분해하여 내부부품의 마모를 확인하였다. 이상진동을 해소하기 위하여 저속회전 및 발란싱 방법을 적용하였는데 발란싱이 저속회전보다 접촉현상 해소에 우수하였다. 따라서 본 연구와 유사한 특성의 이상진동이 증기터빈 축에서 발생할 경우 발란싱은 유력한 해결방안이 될 수 있을 것이다.

  • PDF

점탄성재료의 진동감쇠특성에 관한 연구 (On Dyamping Characteristics of Viscoelastic Materials)

  • 이우식;이준근
    • 전산구조공학
    • /
    • 제7권1호
    • /
    • pp.99-107
    • /
    • 1994
  • 감쇠재료인 점탄성재료는 여러 산업현장에서 발생하는 소음 및 진동문제를 해결하기 위하여 널리 쓰이고 있다. 기존의 진동감쇠 제어기술을 이용하여 이러한 문제를 성공적으로 해결하기 위해서는 먼저 제어하고자 하는 구조물에 적용될 점탄성재료의 진동감쇠 특성이 명확히 규명되어야 한다. 따라서 본 연구에서는 1)우리의 일반적인 실험실 환경에서 모우드해석법을 통해 점탄성재료의 진동감쇠특성을 측정할 수 있는 실험이론과 기법을 정립하고 2)제한된 환경(온도 및 주파수)에서 얻어진 실험 데이타를 이용하여 reduced-frequenct-nomogram(RFN)을 그릴 수 있는 전산프로그램을 개발하였으며 또한 RFN으로부터 확보한 점탄성재료의 진동감쇠특성을 이용하여 감쇠처리된 구조물의 진동해석을 수행하였다.

  • PDF

혼합적층판에 대한 비선형 진동해석 (Analysis of Nonlinear Vibration for Hybrid Composite Plates)

  • 이영신;김영완
    • 대한기계학회논문집
    • /
    • 제16권12호
    • /
    • pp.2306-2314
    • /
    • 1992
  • 본 연구에서는 Lagrangian 방정식을 이용해 알루미늄, CFRP, GFRP, BFRP 등으 로 혼합적층된 cross-ply 사각판에 대해 굽힘-신장연성을 고려하여 Runge-Kutta Gill 법을 적용하여 수치적으로 비선형진동해석을 수행하였다.그리고 여러가지 적층방법 에 따라 비선형 진동에 어떠한 영향이 미치는가를 검토하였으며, 형상비(a/b), 모우드 의 변화 그리고 탄성계수비에 따른 비선형진동 거동을 규명하였다. 한편, 기본진동 수에 대해서는 상용 유한요소프로그램인 ABAQUS의 결과와 비교하였으며, 단일 적층된 판의 비선형진동거동에 대해서는 Singh의 결과와 비교 검토하였다.

발전소 복수 공급 배관계의 고진동과 분기 배기배관의 절손 규명 (Examination on High Vibration and Branch Vent Pipe's Failure of Complex Piping System Suppling Condensate-Water in Power Site)

  • 김연환
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.380-384
    • /
    • 2010
  • A disturbance flow at piping bands and discontinuous regions such as a valve, a header has a intense broadband internal pressure field and a sound field which are propagated through the piping system The fields becomes the source of a vibration of this piping system. Intense broadband disturbance flow at a discontinuous region such as elbows, valves or headers generates an acoustical pulsation. The pulsation becomes the source of structural vibration at the piping system. If it coincides with the natural frequency of the pipe system, excessive vibration results. High-level vibration due to the pressure pulsation affects the reliability of the plant piping system. This paper discusses the high vibration and the branch vent pipe's failure of condensate-water supply piping system due to the effect of acoustical pulsations by flow turbulence from the flow control valves of globe type in a power site.

  • PDF

발전용 대형 2 행정 디젤 엔진 및 기초의 구조 진동해석 (Structural Vibration Analysis of a Large Two-Stroke Engine and Foundation System for Stationary Power Plants)

  • 박종포;신언탁
    • 소음진동
    • /
    • 제10권3호
    • /
    • pp.493-499
    • /
    • 2000
  • Structural vibration analysis of the stationary power plant system employing a large two-stroke low speed diesel engine is performed to verify that the vibration characteristics of the system meet design requirements, The system consists of the diesel engine generator and concrete foundation including pile and soil. The system is modeled in the form of a mass-elastic system of 5 degrees of freedom for vibration analysis. Excitation moments and dynamic parameters including engine body stiffness soil stiffness and damping are identified for the analysis, Results of structural vibration analysis of the system are presented and compared with measurements in this paper.

  • PDF

가속도 측정신호를 이용한 냉장고 홴의 진동원과 방사소음의 예측 (Estimation of Vibration Source and Sound Radiation of a Refrigerator Fan by using Measured Acceleration Signals)

  • 정병규;정의봉
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.834-841
    • /
    • 2011
  • Obtaining the real exciting force is important for the analysis of structural vibration or sound radiation to represent the actual condition. But in most cases, it is so difficult to get the actual force signals by direct measurement using sensors due to complex geometry. This paper suggests advanced source identification method which can be applied to the prediction of radiated noise considering correlations between measured signals. This method was implemented to the identification of the fan force in the refrigerator. The analysis of structural vibration and radiated noise caused by the fan force was also performed. The comparison between predicted SPL and measured SPL of the radiated noise by the refrigerator fan showed good agreement.

대구지역지층의 지질특성과 대표암반에 대한 발파진동계수산출 (Blasting vibration coefficients and mechanical characteristics of Taegu area)

  • 안명석;김종대;김남수
    • 터널과지하공간
    • /
    • 제10권2호
    • /
    • pp.211-217
    • /
    • 2000
  • 본 연구는 대구지역의 대표적인 암석들을 대상으로 일축압축시험 등의 실내 시험과 현장 탄성파속도 시험 등을 실시하여 역학적 특성을 규명하였고, 달서구 성서지역에서 시험발파를 실시하여 발파진동계수를 도출하였다. 그 결과 대구지역의 경상계 퇴적암류는 풍화암에서 경암까지의 다양한 강도 특성을 보였고, 화산암류인 안산암은 경암에서 극경암에 해당되는 것으로 나타났다. 또한 풍화암 내지 보통암에 해당되는 성서지역의 시험발파 결과 발파진동계수 K는 114.8, n은 1.48로 계산되었다.

  • PDF

넓은 주파수 범위에서의 실린더형 유체 댐퍼에 대한 실험적 동특성 규명 연구 (A Study on the Experimental Dynamic Identification of Cylindrical Oil Dampers in the Wide Frequency Range)

  • 문석준;김흥섭;정태영;이동환;황재영
    • 한국소음진동공학회논문집
    • /
    • 제20권6호
    • /
    • pp.528-536
    • /
    • 2010
  • System identification for cylindrical oil dampers is carried out based on a series of dynamic experimental tests and theoretical approach for the analysis of the experimental data. Experimental tests are conducted using a specific hydraulic actuator in the wide frequency range from 10 Hz to 90 Hz. From this study, it is confirmed that control force of the damper is composed of inertia, damping and restoring components. In general, both restoring and damping components are significant and comparable. However, the portion of the inertia components becomes more significant than to be negligible in the high frequency range.