• Title/Summary/Keyword: 진동 규명

Search Result 575, Processing Time 0.028 seconds

A Study on How to Reduce Vibration in order to Decrease the Cracks that Form on the Upper Floor of a Structure due to Continuous Dynamic Loading (반복되는 동하중에 의한 구조물 상부바닥 균열 감소를 위한 진동저감 연구)

  • Chun, Chong-Keun;Park, Sam-Jin;Park, Sang-Gon;Kim, Do-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.4
    • /
    • pp.1532-1538
    • /
    • 2011
  • In this study, we investigate the cracks that formed on the upper floor of the structures due to continuous dynamic loading. We explain the cause of floor slab cracks on the upper floor of the distribution center and discuss preventive measures that can enhance the center's functions and security. In order to explain how a forklift's excessive vibration can cause the cracks, we have measured and analyzed the vibration during a forklift's operation and discovered that the cracks form because the vibration exceeds the vibration criteria. Using a finite element modeling on such results, we have come up with optimal methods to reduce the vibration and confirmed their validity by measuring the vibration after implementing our methods.

Prediction of a Structural Vibration and Radiated Noise of High-voltage Transformer through Force Identification (가진력 규명을 통한 초고압 변압기의 구조진동 및 방사소음 예측)

  • Yoo, Suk-Jin;Jung, Byung-Kyoo;Jeong, Weui-Bong;Hong, Chinsuk;Kim, Tae-Yong
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.6
    • /
    • pp.527-536
    • /
    • 2013
  • In order to predict structural vibration and radiated noise of high-voltage transformer in operation, it is necessary to precisely find the excitation force generated by the coils and core. However, finding the excitation force through experiments of high voltage transformer in operation is not possible. Therefore, this paper deals with identifying the excitation force by using the acceleration data measured through experiments and the transfer function estimated through finite element model. A method to predict structural vibration and radiated noise was also proposed. Three-phase windings and the core are the source of high-voltage transformer. The excitation forces were identified using the acceleration data and the transfer function of the surface of the tank. Structural vibration and radiated noise from the surface of the tank was predicted by using the identified excitation force. As a result of the interpretation of the experimental and computational analysis of structural vibration from the surface of the tank and radiated noise from the field point, the interpretation of the computational analysis showed relatively good accordance with the experiment.

Identification on Fatigue Failure of Impeller at Single Stage Feedwater Pumps During Commissioning Operation (단단 주 급수 펌프 임펠러에서 시운전 중 발생한 피로 절손에 관한 규명 연구)

  • Kim, Yeon-Whan;Kim, Kye-Yean;Bae, Chun-Hee;Lee, Young-Shin
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.9
    • /
    • pp.937-942
    • /
    • 2008
  • This paper presents a case history on failures of impeller and shaft due to pressure pulsation at single stage feed water pumps in 700 MW nuclear power plant during commissioning operation. The pumps had been service and had run for approximately $40{\sim}50$ hours. For the most part, the failures of impeller occurred with the presence of a number of fatigue cracks. All cracks were associated with the deleterious surface layer of impeller by visual and metallurgical examination. On-site testing and analytical approach was performed on the systems to diagnose the problem and develop a solution to reduce the effect of exciting sources. A major concern at high-energy centrifugal pump is the pressure pulsation created from trailing edge of the Impeller blade, flow separation and recirculation at centrifugal pumps of partial load. Pressure pulsation due to the interaction generating between impeller and casing coincided with natural frequencies of the impeller and shaft system during 1ow load operation. It was identified that dynamic stress exceeding the fatigue strength of the material at the thin shroud section due to the hydraulic instability at running condition below BEP.

Investigation on optimum applied potential for corrosion resistance and cavitation-erosion damage reduction of Al alloy in seawater (알루미늄 합금의 해수 내 내식성 및 캐비테이션-침식 손상 저감을 위한 적용전위 규명)

  • Jeong, Gwang-Hu;Park, Il-Cho;Lee, Jeong-Hyeong;Han, Min-Su;Kim, Seong-Jong
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2018.06a
    • /
    • pp.112-112
    • /
    • 2018
  • 알루미늄 합금은 내구성과 내식성이 우수한 경량 재료이다. 그 중 Al-Mg계 5083 Al 합금은 가공성 및 용접성이 우수하여 선체 재료로 널리 이용되고 있다. 이는 선체 중량의 경량화로 인해, 연료비 절감과 빠른 선속 등 다양한 이점을 지니기 때문이다. 그러나 선박의 고속화에 따라 선체에 가해지는 유체충격이 증가하고, 압력 저하에 기인하여 캐비테이션-침식 손상이 증가할 뿐만 아니라, 염소이온이 존재하는 해수환경에서는 침식과 부식의 시너지효과로 인하여 재료의 손상이 더욱 가속화된다. 이에 대한 다양한 방지책들이 제안되고 있으나, 강한 충격압을 동반한 캐비테이션 침식-부식 복합 손상 환경에서는 다소 한계가 있다. 따라서 본 연구에서는 알루미늄 5083에 대하여 캐비테이션 환경 하에서 일정 전위를 인가하며 침식-부식 손상이 최소화 되는 전위 구간을 규명하고자 하였다. 먼저, 분극 실험을 선행하여 재료의 전기화학적 거동을 파악 한 후 적용 전위구간을 선정하여, 해당 전위를 인가한 상태에서 캐비테이션 실험을 실시하였다. 전기화학적 분극실험과 캐비테이션-전기화학 복합 실험은 $25^{\circ}C$의 해수 하에서 실시하였으며, 시험편의 노출면적은 $3.24cm^2$으로 하였다. 분극 실험은 개로전위로부터 +3 V까지 2 mV/s의 분극속도로 전위를 인가하였고, 기준전극으로 Ag/AgCl, 대극으로 백금전극을 사용하였다. 캐비테이션-전기화학 복합 실험은 정전위를 인가한 상태에서 대향형 진동법으로 진동수 20 kHz, 진폭 $30{\mu}m$ 진동을 20분간 가하였으며, 혼팁과 시험편 사이의 거리는 1 mm로 일정하게 유지하였다. 실험 후 표면 손상의 정량적 분석을 위해 인가된 전위별 전류밀도를 비교하고, 무게감소량을 측정하였으며, 손상경향 파악을 위하여 3D광학현미경과 주사전자현미경(SEM)을 통해 표면을 분석하였다.

  • PDF

An Experimental Study on Dynamic Properties of Concrete with Vibration-Mitigation Materials (제진재 혼입 콘크리트의 동적물성에 관한 실험적 연구)

  • Chung, Young-Soo;Park, Yong-Goo
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.261-270
    • /
    • 1999
  • In these days, construction activities have caused civil petitions associated with vibration-induced damages or nuisances. Therefore, it is strongly needed to develop a remedial technique to mitigate unfavorable effects. The objective of this experimental research is to investigate material and structural dynamic characteristics of vibration-controlled concretes which have been proportionally mixed with various vibration reducing material, such as latex, rubber powder, plastic resin, polystyrofoams and etc. Normal and high strength concrete specimens are also prepared for corresponding comparison. As part of the recycling research for obsolete rubber and plastic materials, 32 concrete cylinders and 10 concrete flexural beams have been made for material and structural dynamic properties, respectively. In accordance with the resonance test on concrete cylinders, it can be concluded that concrete with vibration-reducing material have relatively larger material damping ration than normal or high strength concrete. Styrofoam is determined to be very effective vibration-reducing mixtures. From the vibration test on 10 concrete flexural beams, meamwhile, of importance observations was that material damping ratio is very smaller than structural damping ratio of corresponding specimen. But further vibration test on more flexural beams should be strongly needed by varying support conditions.

Effect of Whole Body Vibration Training in Drop Landing Jump (전신진동운동이 드랍랜딩점프 동작에 미치는 영향)

  • Hong, Su-Yeon;Jang, Young-Kwan;Kim, Jin-Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.423-429
    • /
    • 2018
  • Objective: This study was conducted to investigate the effects of WBVE on biomechanical factor analysis of drop landing jumps before and after a four week training program. Methods: Participants were divided into two group: VEG (n=5, age: $25.7{\pm}2.3yrs$, height: $170{\pm}7.6cm$, weight: $69.3{\pm}8.3kg$) and OEG (n=5, age: $24.6{\pm}3.4yrs$, height: $164{\pm}4.9cm$, weight: $58.8{\pm}9.2kg$). Ten infrared cameras (Vicon, UK) with a sampling rate of 100 Hz were used in two GRF measurement systems (AMTI, USA). Results: The variability of the center of mass was largest at the falling phase, and there was a great risk of injury when landing after the jump. Second, the jumping heights of the VEG (vibration exercise group) were higher than those of the OEG (only exercise group), regardless of training period. Third, there were significant differences in the hip joint P1 (flexion) and knee joint P2 (extension) between the exercise groups after 4 weeks of training. However, there were no significant differences among training periods or phases. Conclusion: regardless of training periods, the VEG showed increased jump height compared with the OEG, but the consistency between the jump height and the lower joint power could not be determined.

The Power Spectral Density Characteristics of Lift and Drag Fluctuation of Fin Tube in a Heat Recovery Steam Generator (배열회수 보일러 단일 휜튜브의 양력과 항력 변동에 따른 PSD 특성 연구)

  • Ha, Ji Soo;Lee, Boo Youn
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.2
    • /
    • pp.23-29
    • /
    • 2016
  • Heat exchanger tube array in a heat recovery steam generator is exposed to the hot exhaust gas flow and it could cause the flow induced vibration, which could damage the heat exchanger tube array. It is needed for the structural safe operation of the heat exchanger to establish the characteristics of flow induced vibration in the tube array. The researches for the flow induced vibration of typical heat exchangers have been conducted by using single cicular tube or circular tube array and the nondimensional PSD(Power Spectral Density) function with the Strouhal number, fD/U, had been derived by experimental method. From the present study, the basis for the application of flow induced vibration to the heat recovery steam generator tube array would be prepared. For the previous mentioned purpose, the present CFD analysis introduced a single fin tube and calculated with the unsteady laminar flow over the single fin tube. The characteristics of vortex shedding and lift and drag fluctuation over the fin tube was investigated. The derived nondimensional lift PSD was compared with the results of the previous experimental studies and the characteristics of lift and drag PSD over a single fin tube was established from the present CFD study.

Vibration and Stability Characteristics of Cylindrical Panels by the Galerkin Method (Galerkin 해석법에 의한 원통 Panel의 진동 및 좌굴특성)

  • Park, Moon Ho;Park, Sung Jin
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.11 no.4
    • /
    • pp.27-35
    • /
    • 1991
  • This paper presents a numerical analysis procedure and a characteristics for vibration and buckling of the cylinderical panels. The panels with simply-simply or simply-clamped edge supports are subjectes to circumferential compressive or flexural stresses. The differential equations governing vibration and buckling for these panels are derived by using the fundamental differential equation of the Love-Timoshenko and are solved numerically via the Galerkin method. The panel with simply-clamped edge supports is used a trigonometric function or a eigen function of a beam as a trial function and the effects of trial functions on numerical solutions are displayed. Numerical results are presented to demonstrate the effects of the flexural parameters in natural frequencies and coefficients of critical buckling and some typical mode shapes of vibration and buckling are also presented.

  • PDF

High Frequency Ventilation (고빈도 환기법)

  • Lee, Hyeon-U;Lee, Gwan-Ho
    • Journal of Yeungnam Medical Science
    • /
    • v.10 no.1
    • /
    • pp.1-17
    • /
    • 1993
  • 고빈도 환기법은 최근에 개발되어 임상에 응용되면서 호흡생리학, 마취학, 집중치료의 학등의 분야에서 호흡부전의 새로운 치료법으로 관심이 집중되고 있는 환기법이다. 현재까지 고빈도 환기법중 고빈도 양압 환기와 제트 환기는 비교적 많은 연구가 되고 있고 임상적으로 사용되고 있으나 고빈도 진동 환기법은 제한적으로 사용되고 있다. 앞으로 고빈도 진동 환기법에 대해서도 더 많은 연구가 되어야 할 것이다. 또한 최근 개발되고 있는 고빈도 흉벽 진동 환기와 체표면 진동 환기에도 관심을 기울이면 호흡부전 환자의 치료에 바람직한 새로운 환기법이 될 수 있을 것으로 기대된다. 현재 고빈도 환기법의 몇몇 적용형태는 기관지-늑막루등의 폐압손상으로 인한 병변의 치료외에도 기관수술, 흉부수술, 뇌수술에서 수술부위의 움직임을 최소화시키면서 충분한 가스교환율 이룩할 수 있어서 효과적으로 이용되고 있다. 그러나 응급심폐소생술, 폐쇄성 폐질환, 성인 또는 영아 호흡곤란증후군등과 같은 질환에서의 적용은 더 규명되어져야겠다. 고빈도 환기법의 여러가지 문제점중 적절한 환기빈도의 결정, 충분한 습도를 공급하는 장치, 고빈도 환기의 정확한 감시장치의 개발등은 앞으로 우선적으로 해결해야 할 문제점이다. 또한 임상에 더욱 효과적으로 응용될 수 있는 새로운 환기법이 되기 위해서는 고빈도 환기법의 호흡생리와 안정성등에 관한 연구도 병행되어야겠다.

  • PDF

An Investigation on the Lateral Vibration of General Rotors Considering Additional Effects (부수적인 영향 을 고려한 일반적인 회전축 의 횡진동 에 관한 연구)

  • 한동철
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.1
    • /
    • pp.81-90
    • /
    • 1985
  • For the prediction of the real vibration and stability behaviour of rotor-beaing systems, various additional effects were considered, which are simplified or neglected by conventional modeling of real rotors. These are specially coupled spring and damping coefficients of journal bearings, spring and damping coefficients of external supporting elements for bearings, static load exerting on gears or pulleys by power transmissions, excitation through the gear tolerance or failure, and positive or negative spring and damping characteristics of magnetic or sealing friction force. Considering these effects, a computer program for the calculation of free and forced vibration of rotating shafts supported by two or more bearings is developed, based on the transfer matrixed method. The reliability of the calculated resutls were ascertianed by comparing with the measured data on high speed rotors supported by two journal bearings.