• Title/Summary/Keyword: 진동환경 시험

Search Result 301, Processing Time 0.026 seconds

Life Prediction of Failure Mechanisms of the CubeSat Mission Board using Sherlock of Reliability and Life Prediction Tools (신뢰성 수명예측 도구 Sherlock을 이용한 큐브위성용 임무보드의 고장 메커니즘별 수명예측)

  • Jeon, Su-Hyeon;Kwon, Yae-Ha;Kwon, Hyeong-Ahn;Lee, Yong-Geun;Lim, In-OK;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.44 no.2
    • /
    • pp.172-180
    • /
    • 2016
  • A cubesat classified as a pico-satellite typically uses commercial-grade components that satisfy the vibration and thermal environmental specifications and goes into mission orbit even after undergoing minimum environment tests due to their lower cost and short development period. However, its reliability exposed to the physical environment such as on-orbit thermal vacuum for long periods cannot be assured under minimum tests criterion. In this paper, we have analysed the reliability and life prediction of the failure mechanisms of the cubesat mission board during its service life under the launch and on-orbit environment by using the sherlock software which has been widely used in automobile fields to predict the reliability of electronic devices.

Typical Seismic Intensity Calculation for Each Region Using Site Response Analysis (부지응답해석을 이용한 지역별 대표 진도 산출 연구)

  • Ahn, Jae-Kwang;Son, Su-Won
    • Journal of the Korean GEO-environmental Society
    • /
    • v.21 no.1
    • /
    • pp.5-12
    • /
    • 2020
  • Vibration propagated from seismic sources has damping according to distance and amplification and reduction characteristic in different regions according to topography and geological structure. The vibration propagated from the seismic source to the bedrock is largely affected by the damping according to the separation distance, which can be simply estimated through the damping equation. However, it is important to grasp geological information by location because vibration estimation transmitted to the surface are affected by the natural period of the soil located above the bedrock. Geotechnical investigation data are needed to estimate the seismic intensity based on geological information. If there is no Vs profile, the standard penetration tests are mainly used to determine the soil parameters. The Integrated DB Center of National Geotechnical Information manages the geotechnical survey data performed on the domestic ground, and there is the standard penetration test information of 400,000 holes. In this study, the possibility of quantitation the amplification coefficient for each region was examined to calculated the physical interactive seismic intensity based on geotechnical information. At this time, the shear wave column diagram was generated from the SPT-N value and ground response analysis was performed in the target area. The site coefficients for each zone and the seismic intensity distribution for the seismic motion present a significant difference according to the analysis method and the regional setting.

The Study on the Implementation and Design of Power Supply Unit of Digital Communication Satellite (디지털위성중계기용 전원공급기 설계 및 구현에 대한 연구)

  • Kim, Ki-Jung
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.9
    • /
    • pp.855-860
    • /
    • 2016
  • This study describes the design and implementation of digital Payload power supply. We materialized the interface of the PLDIU and power supply of a satellite bus, and minimized the potential for the occurrence of such erroneous operation circuit ESD through the WCA of the space environment. We designed a reliable power supply through simulation for a TID according to the vibration generated during the launch and space radiation environment, and found no problem in the function and performance through the test space environment after production.

Drift Test Method of Meteorological Instrument for Type Approval (형식승인을 위한 측기의 드리프트 검사 방법)

  • Seo, Dae-Il;Lee, Kyung-Hun;Kwon, Byung-Hyuk
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.927-932
    • /
    • 2022
  • Instrument drift is caused by the passage of time, environmental changes, normal wear and tear, debris buildup, sudden shock, vibrations, electromagnetic fields, and improper use. Since it is inappropriate to directly determine the change of the output value as drift during the limited test period, a new algorithm that reflects both zero drift and span drift by giving changes over time to the calibration method of the instrument was proposed. The temperature drift was calculated to be 0.49% for about 60 minutes at 1-minute intervals in the nine-step constant temperature environment through the warming and cooling process.

Visual Perception Dynamics of Relative Phase Coordination Pattern with Additional Visual Information Using a Background Grid (상대위상을 이용한 시각적 협응 패턴의 지각 역학과 격자무늬를 이용한 부가적 감각 정보에 따른 영향)

  • Ryu, Young-Uk
    • Korean Journal of Cognitive Science
    • /
    • v.23 no.3
    • /
    • pp.409-424
    • /
    • 2012
  • The purpose of the present study was to examine if perception of visual coordination pattern is consistent with the prediction of the HKB model (Haken, Kelso, Bunz, 1985). In addition, this study aimed to see if an additional sensory information using a grid background stabilizes perception of coordination pattern. Participants joined one of two experimental groups, Normal background and Grid background, to participate the pattern recognition training session and the pattern judgment test session. Participants observed $0^{\circ}$, $18^{\circ}$, $36^{\circ}$, $54^{\circ}$, $72^{\circ}$, $90^{\circ}$, $108^{\circ}$, $126^{\circ}$, $144^{\circ}$, $162^{\circ}$, and $180^{\circ}$ coordination patterns characterized by two oscillating dots. The dots oscillated in 0.25 Hz for the pattern recognition training and in 0.5 Hz, 1 Hz, and 2 Hz for the pattern judgment test. Judgment score, absolute judgment error, and judgment stability out of the pattern judgment test were analyzed statistically. The landscape of pattern accuracy and stability data was "inverted-U" shape with slower oscillating frequency conditions. In the faster condition, the accuracy and stability of the judgment decreased with relative phase patterns near $180^{\circ}$. These findings consistent with the prediction of the HKB model. The grid as additional sensory information did not increase accuracy and stability in coordination perception.

  • PDF

Basic Characteristic Verification of High-damping Laminated Solar Panel with Viscoelastic Adhesive Tape for 6U CubeSat Applications (점탄성 테이프를 적용한 6U 큐브위성용 고댐핑 적층형 태양전지판의 기본 특성 검증)

  • Kim, Su-Hyeon;Kim, Hongrae;Oh, Hyun-Ung
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.1
    • /
    • pp.86-94
    • /
    • 2021
  • PCB-based deployable solar panel is mainly used for CubeSat due to its lightweight and easy of electrical connection. However, as the size of solar panel increases, there is a limit to ensuring the structural safety of solar cells due to excessive dynamic displacement under launch vibration environment. In previous mechanical designs, for the minimization of dynamic deflection, panel stiffness is increased by applying additional stiffeners made of various materials such as aluminum or composite. However, it could have disadvantages for CubeSat design requirements due to limited mass and volumes. In this study, a high-damping 6U solar panel was proposed. It had superior damping characteristic with a multi-layered stiffener laminated with viscoelastic acrylic tapes. Basic characteristics of this solar panel were measured through free-vibration tests. Design effectiveness of the solar panel was validated through qualification-level launch vibration test. Based on test results, vibration characteristics of a typical PCB solar panel and the high-damping laminated solar panel were predicted and a comparative analysis was performed.

Release Mechanism for small satellite using micro DC motor (소형 위성용 소형직류모터를 이용한 분리장치)

  • Tak, Won-Jun;Jo, Jae-Uk;Lee, Min-Soo;Kim, Byung-Kyu
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.8
    • /
    • pp.767-773
    • /
    • 2010
  • This paper describes development of a non-explosive separation device which can be equipped on small satellites. The spur geared micro DC motor, which has high reliability and advantage of price, is adopted as an actuator. The proposed separation device has resettability and it does not need extra jig to reload. In addition, the simple structure makes it easy to fabricate and assemble. To verify the performance of the proposed device, the response time tests, maximum preload tests and maximum shock level tests were performed. Also, through the vibration tests and thermal vacuum tests, feasibility of the proposed separation device was shown in launching and space environments. Therefore, we expect that the proposed separation device can replace the imported separation devices in near future.

Experimental Study of VIV Characteristics of Free Hanging PVC Pipe under Forced Oscillation Conditions (강제가진조건에서 자유롭게 매달린 PVC 파이프의 와류유기진동 특성에 관한 시험 연구)

  • Kwon, Yong-Ju;Jung, DongHo;Park, Byeong-Won;Jung, Jae-Hwan;Oh, Seunghoon
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.341-350
    • /
    • 2018
  • A series of model tests was carried out to investigate the vortex-induced vibration (VIV) characteristics of a free hanging PVC pipe under forced oscillation conditions. The prescribed displacement with a period and amplitude was forced at the top of the riser. The motion of the riser along its length was measured with underwater cameras in three dimensions. The top-excited responses in the inline direction and vortex-induced vibration in the cross-flow direction were examined in the time and frequency domains. Multi-peak frequencies in the VIV were demonstrated to be strongly dependent upon the Keulegan-Carpenter number, corresponding with the results of Blevin. It was found that the Reynolds numbers (excitation period) was a critical parameter for the dominant VIV characteristics, even under the condition of using the same Keulegan-Carpenter number, under the top-excited condition. In the resonance at the nth natural frequency by the forced-motion induced VIV frequency, the riser responded with a large amplitude and forced frequency, dominantly in the VIV CF direction.

Noise influence Coming to Existing Neighborhood Area by Extension of Power Site and Noise Reduction Service (발전소 증절이 부지경계의 가존 지역에 미지는 소음영향과 저감 대책)

  • Kim, Yeon-Whan;Goo, Jae-Rayng;Bae, Chun-Hee;Kim, Kye-Yean;Yang, Dong-Cheol
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2009.10a
    • /
    • pp.716-722
    • /
    • 2009
  • 4000MW급 유연탄발전소는 기존 500MW급 4기의 발전설비 운영조건에서 지역공동체는 긍정적이었으나, 500MW급의 증설 호기가 늘어나면서 지역 공동체는 발전소 증설과 관련하여 기존 동쪽 부지 경계지역의 소음환경에 대하여 부정적인 문제를 제기하였다. 2000MW급 증설이 진행되어온 4000MW급 발전소의 다양한 소음원에 의한 소음파워 증대와 증가방출 과도소음 에 대하여 고저가 다양한 주변지역에 미치는 영향음 평가하고자 3차원 모델링기법을 적용한다. 기존호기를 비롯한 전체의 발전소 전면부 소음원응 비교 시험결과 증가방출 소음 파워가 기존 설계의 변경 제작되어 기존호기에 비해 20~30dBA 높아져 동시 방출사 주변지역에 과도하게 영향을 미치는 상태였으며 500MW급 4기를 추가 증설에 따라 일상소음원에 의한 소음 영향도 증설전 대비 2~3dBA 증가된 것으로 평가되었다. 따라서 증설호기의 과도 소음원 제거 방안으로 대가 방출증가가 회수되도록 증설호기의 증가방출설비를 개선하였고, 증설에 의하여 증가된 소음 영향음 저감하고자 기존 경계지역에 미치는 소음원음 고려하여 방음벽음 설치한 결과 47 ~ 49dBA를 나타내고 인근 주거건물의 전면부 소음은 43dBA이었다.

  • PDF

Vibration and Noise Analysis According to Blasting Method (발파공법에 따른 진동 및 소음 분석)

  • Kim, Min-Hyouck
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.150-151
    • /
    • 2022
  • Blasting is a method that uses explosives to crush the ground. This method is a highly efficient ground cleaning method that can secure high efficiency in a short time. However, explosions can damage local properties and produce high noise and vibration. Therefore, it is important to be careful because there are disadvantages such as the occurrence of many complaints from the surrounding area. In this paper measured and analyzed the noise and vibration generated during blasting at the blasting site in Korea. The noise and vibration generated during blasting were measured by ES03303.2b and ES03402.2a at a distance of 6 m, 12 m from the blasting point. As a result of the measurement, there was little difference between small and medium scale except for precision vibration blasting at a distance of 6m, but noise difference according to blasting scale was evident at a distance of 12m. As a result of the measurement, the maximum noise level was reduced to 5.5 dB(A) and the vibration level was reduced to 7.7 dB(V). In the future, the reliability of the test results can be further improved through additional tests, and it is judged that noise and vibration prediction models based on blasting methods, amount of charge, measuring distance, etc. can be developed.

  • PDF