• Title/Summary/Keyword: 진동절연기

Search Result 60, Processing Time 0.029 seconds

Validation of Structural Safety on Multi-layered Blade-type Vibration Isolator for Cryocooler under Launch Vibration Environment (적층형 블레이드가 적용된 냉각기용 진동절연기의 발사환경에서의 구조건전성 검증)

  • Jeon, Young-Hyeon;Ko, Dai-Ho;Jo, Mun-Shin;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.7
    • /
    • pp.575-582
    • /
    • 2018
  • The spaceborne cooler is applied to cool down of the focal plane of the infrared detector of the observation satellite. However, this cooler induces unnecessary micro-jitter which can degrade the image quality of the high-resolution observation satellite. In this study, we proposed a multi-layered blade type vibration isolator to attenuate micro-vibration generated from a spaceborne cooler, while assuring structural safety of the cooler under severe launch loads without an additional launch-lock device. The blade of the isolator is formed with multi-layers in order to obtain durability against fatigue failure and an adhesive is applied between each layers for granting high damping capability under launch vibration environment. In this study, the basic characteristics of the isolator were measured using the free-vibration test. The effectiveness of the isolator design was demonstrated by launch vibration test at qualification level.

Investigation of Micro-vibration Isolation Performance of SMA Mesh Washer Isolator for Vibration Isolation of X-band Antenna (SMA 메쉬 와셔 진동 절연기를 적용한 X-band 안테나의 미소진동 절연성능 검토)

  • Jeon, Su-Hyeon;Kwon, Sung-Choel;Kim, Dae-Kwan;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.11
    • /
    • pp.988-995
    • /
    • 2014
  • Two axis gimbal type X-band antenna system has been widely used to effectively transmit the real time image data from the observation satellite to the ground station. The micro-vibration generated by stepping motor actuation and imperfect intermeshed gear configuration of the antenna is one of the sources to degrade the image quality. To guarantee a high quality image of high resolution observation satellite, micro-vibration isolation of X-band antenna is required. In this paper, the X-band antenna vibration isolation system using pseudoelastic SMA(Shape Memory Alloy) mesh washer has been newly suggested. The basic characteristics of the SMA mesh washer isolator proposed in this study has been measured through static load tests and its effectiveness has been demonstrated by the micro-vibration isolation test of the X-band antenna.

Numerical Investigation of Complex System for Electrical Energy Harvesting and Vibration Isolation (미소진동 발생원으로부터의 전기에너지 재생 및 진동절연을 위한 복합 시스템의 해석적 검토)

  • Kwon, Sung-Cheol;Jo, Mun-Shin;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.42 no.8
    • /
    • pp.648-653
    • /
    • 2014
  • Fly-wheel, gimbal antenna, mechanical gyro and cryocooler with moving parts generate a micro-vibration during their on-orbit operation. For the acquisition of high quality image of observation satellite, additional technical efforts are required to reduce the micro-vibration level from the vibration sources. In this study, we proposed a passive isolation system combined with a tuned mass damper-type energy harvester to generate electrical energy from the micro-vibration which has always been subjected to useless isolation objectives. The feasibility of the system has been investigated through the numerical simulation.

Thermal Design of Cryogenic Compressor with Strategies for Keeping Performance of Micro-vibration Isolation System (미소진동저감용 진동절연기의 성능유지를 위한 극저온 냉각용 압축기 조립체 열제어 설계)

  • Oh, Hyun-Ung;Lee, Kyung-Joo;Jeong, Suk-Yong;Shin, So-Min
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.40 no.3
    • /
    • pp.237-242
    • /
    • 2012
  • Spaceborne pulse tube-type cryogenic compressors are widely used for space applications. To guarantee cooling performance of the compressor, mission life time and micor-vibration stability, suitable thermal control of compressor is required. Micro-vibration of the compressor is the one of the sources to degrade the pointing performance of observation satellite. In the present work, on-orbit thermal design of compressor in order not to degrade the performance of micro-vibration isolation system keeping the thermal control performance has been proposed and investigated through thermo-mechanical analysis.

A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator (다양한 수동 진동 절연 장치의 진동 절연 특성 비교)

  • Lee, Dae-Oen;Han, Jae-Hung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.9
    • /
    • pp.817-824
    • /
    • 2012
  • Transmission of unwanted vibration to sensitive systems can cause various problems including performance degradation and system malfunction. The most common approach to limit the transmission of harmful vibration disturbances to the sensitive system is adapting passive vibration isolator. The classical passive vibration isolator comprising a viscous damper and spring element in parallel, however, exhibits conflicting performance characteristics in that low amplification at the resonance, which is desirable, can only be achieved at the sacrifice of vibration isolation performance in high frequency region, which is undesirable. In this paper, vibration isolation characteristics of various passive isolator schemes in literature to circumvent this conflict are introduced and compared.

A Comparison of Vibration Isolation Characteristics of Various Forms of Passive Vibration Isolator (다양한 수동 진동 절연 장치의 진동 절연 특성 비교)

  • Lee, Dae-Oen;Han, Jae-Hung
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.232-237
    • /
    • 2012
  • Transmission of unwanted vibration to sensitive systems can cause various problems including performance degradation and system malfunction. The most common approach to limit the transmission of harmful vibration disturbances to the sensitive system is adapting passive vibration isolator. The classical passive vibration isolator comprising a viscous damper and spring element in parallel, however, exhibits conflicting performance characteristics in that low amplification at the resonance, which is desirable, can only be achieved at the sacrifice of vibration isolation performance in high frequency region, which is undesirable. In this paper, vibration isolation characteristics of various passive isolator schemes in literature to circumvent this conflict are introduced and compared.

  • PDF

전기설비의 절연열화 진단 기법

  • 곽희로;임기조;구자윤;강성화
    • 전기의세계
    • /
    • v.46 no.8
    • /
    • pp.34-40
    • /
    • 1997
  • 케이블 시스템의 사고는 예방 진단에 근거한 정확한 진단으로 피할 수 있으며, 잔여수명 예측 기술은 진단 방법의 체계적인 적용에 의해 향상될 수 있다. 따라서 본 고에서는 케이블 시스템 진단 방법의 체계적인 개발을 위해서 60 kV급 이상의 종이 절연 혹은 고분자 절연 전력 케이블과 그 접속 자재에 대해서만 진단 방법을 개략적으로 소개만하고 있으며 수트리에 관련된 열화, 절연체의 열화를 제외한 모든 열화현상과 DC 케이블에 대해서는 언급을 하지 않았다. 회전기 고체절연체의 열화에 의해 야기되는 변화는 회전기 진동을 발생 시키고, 진동은 기계에 심각한 손상을 발생시킨다. 회전기의 절연열화 진단은 유전손실, 유전율, 음향 등의 측정/분석으로 가능하고 적용 방법은 on-line/off-line으로 가능하다. 절연 시스템의 열화정도 판정은 회전기의 적절한 보수시기의 판단을 가능하게 하여 유지 보수비의 절감 및 회전기의 수명연장을 가능하게 할 것이다.

  • PDF

Isolating Vibration in Miniature Linear Cryogenic Cooler with Tuned Vibration Absorber (동조질량 진동흡수기를 이용한 미니 저온쿨러의 진동 절연)

  • Kim, Young-Keun;Kim, Hong-Bae;Kim, Eung-Hyun;Kim, Kyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.34 no.5
    • /
    • pp.605-609
    • /
    • 2010
  • In modern surveillance equipment, infrared (IR) sensors are essential for detection and observation. The IR sensor is connected to a miniature cryogenic cooler to maintain the temperature at very low levels, i.e., temperatures as low as 77 K. However, the quality of the image captured by the sensor is degraded by the transmission of vibration disturbances from the cooler. Therefore, to maintain high image quality, the compressor vibration and the force transmitted to the sensor have to be mitigated. For the compressor vibration isolating system, a tuned dynamic vibration absorber, combined with a passive isolator, is proposed. A cryogenic compressor bracket and springs are designed to allow the absorber mass to mitigate the vibration jitter in the axial direction. The system design is analyzed and evaluated in terms of the dynamic suppression of the harmonic force at the operating frequency of the cooler.

Experimental Comparison on Vibration Attenuation Performances of the Piezoelectric Mount in Same Geometric Constraints with the Rubber Mount (고무마운트와 동일한 형상 조건을 갖는 압전마운트의 진동저감 성능에 대한 실험적 비교 고찰)

  • Han, Young-Min
    • Journal of Convergence for Information Technology
    • /
    • v.11 no.11
    • /
    • pp.166-171
    • /
    • 2021
  • An active mount is devised in same geometric constraints with a conventional rubber mount. The proposed mount features the piezoelectric actuator which can be used to reduce the vibration at marine vessels or automotive vehicles. As a first step, a passive rubber mount is adopted and its dynamic characteristics are experimentally evaluated. Based on the geometry of the rubber mount, a rubber element for the active mount is manufactured and integrated with two piezostacks in series, in which the piezostack is operated as an inertial type of actuator. A conventional PID controller featured by the simple and easy implementation, is then designed to attenuate the non-resonant high frequency vibration transmitted from the base excitation. Finally, the control performances of a proposed active mount are evaluated in the wide frequency range and compared with those of the conventional rubber mount.

일반적인 구조물을 위한 동흡진기 설계 방법

  • 김재욱;강중옥;홍성욱
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.71-71
    • /
    • 2004
  • 일반적으로 동흡진기는 하나의 가진진동수에 의해 진동하는 감쇠가 작은 기계나 구조물에 효과적으로 적용되고 있다 대부분의 동흡진기의 적용 사례는 주 진동이 유발되는 부위, 또는 진동을 억제해야하는 부위에 직접적으로 동흡진기를 부가하여 효과를 얻는 방식을 택하고 있다. 그러나 절연기를 설치 할 수 없는 경우라든지, 절연기로는 한계가 있는 경우, 이미 설치가 완료된 기계 시스템에 절연 변경이 곤란한 경우 또는 국부 진동모드에 대한 진동저감을 할 때는 동흡진기에 대해 보다 일반적인 접근 방법이 필요하며 질량과 스프링계를 부착하기 힘든 경우나 억제시키려는 부위에 설비나 기기의 성능을 저해할 수 있는 경우에는 부득이 그 위치를 변경시켜 줘야 할 경우가 생긴다 할 수 있다.(중략)

  • PDF