• Title/Summary/Keyword: 진동응답

Search Result 1,625, Processing Time 0.032 seconds

A Study on the Vibration Criteria for Precision Equipment using FRF (주파수 응답함수를 이용한 정밀장비의 진동허용규제치에 관한 연구)

  • Lee, Hong-Ki;Park, Hae-Dong;Choi, Hyun;Kim, Doo-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.305-311
    • /
    • 1995
  • 본 논문에서는 정밀 장비에 대한 전반적인 진동성능시험에 대하여 개설하고 주파수응답함수를 이용한 정밀 장비의 진동허용규제치를 결정할 수 있는 새로운 간편한 방법을 모색하고자 한다. 그리고 이러한 방법을 HDD(Hard Disk Driver)의 진동허용규제치를 결정하는 것에 적용하여 그 유용성을 확인하고자 한다.

  • PDF

Stability Analysis of Combination Resonance Responses of a Circular Plate with Internal Resonance (내부공진을 가진 원판의 조합공진응답의 안정성 해석)

  • 이원경;김철홍
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1993.04a
    • /
    • pp.23-29
    • /
    • 1993
  • 내부공진 (.omega.$_{3}$ = .omega.$_{1}$ + 2.omega.$_{2}$)을 가진 원판 의 조합공진(.OMEGA. = 2.omega.$_{1}$ + .omega.$_{2}$)응답의 안정성 을 해석한 결과 다음과 같은 결론을 얻었다. 1) 모든 진폭이 0(.alpha.$_{1}$=.alpha.$_{2}$=.alpha.$_{3}$=0)인 공진응답 은 매개변수의 값에 관계없이 안정하다. 2) 모든 진폭이 0이 아닌 (.alpha.$_{1}$.neq.0, .alpha.$_{2}$.neq.0, .alpha.$_{3}$.neq.0) 공진응답은 쌍으로 존재하는데 진폭이 큰 응답(upper branch)은 안정하나 진폭이 작은 응답(lower branch)은 불안정하다. 3) 진폭이 0이 아닌 공진응답이 존재하지 않는 경우에는 선형계와 마찬가지 로 모든 진폭이 0이 공진응답(결과적으로 비공진 응답)이 계의 응답을 지배 하지만 모든 진폭이 0이 아닌 공진응답이 존재하는 경우에는 안정한 공진응 답이 2개이므로 초기조건이 실제의 응답을 결정하게 된다.

  • PDF

높이-직경비가 큰 지진시험모델의 강제진동시험과 지진에 대한 응답해석

  • 박형기;조양희;윤철호
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05d
    • /
    • pp.386-391
    • /
    • 1996
  • 동경전력(주)가 도쿄만 근처에 건설한 높이-직경비가 비교적 큰 지진시험모델(TEPSCO모델)에 수행한 강제진동시험결과와 시험모델의 지진응답을 해석하고 분석하였다. 재료시험과 지반조사 결과를 이용하여 예측해석모델을 만들었고, 시험시에 계측된 측정치를 반영하여 예측해석모델을 수정하여 예측후상관해석모델을 작성하였다. 해석은 진동수영역과 시간영역에서 각각 이루어졌다. 연구결과로 TEPSCOT모델의 경우는 부지와 시험모델의 형상특성으로 인하여 지반의 재료감쇠비가 동적응답에 미치는 영향이 지배적이었음을 알 수 있었다.

  • PDF

Transmissibility Effect Evaluation of Buildings Near Railroad Areas (철도인접지역 건물에 대한 진동전달율의 영향성 평가)

  • Kim, Ji-Hyeon;Yoon, Sung-Won
    • Journal of Korean Association for Spatial Structures
    • /
    • v.11 no.1
    • /
    • pp.131-138
    • /
    • 2011
  • For train vibration influence assessment of newly constructed buildings in building design levels, 4 train measured vibration acceleration responses were used to compare with TR theory values and suitability of TR values was proposed. Through this TR method, construction planned grounds located near railroad areas were selected and ground vibration measurement was conducted. Through natural frequency by MIDAS, vertical acceleration response, and ground frequency from measured vibration response, TR was calculated and vibration prediction was conducted. As a result of comparing acceleration response estimate applying TR and measured value of train vibration acceleration response, it was found that it was in 3.61%~37.1% of margin of error. Clear peak of 7.19~10.61Hz in KTX, Gyungeuisun, and cement train were confirmed.

Vibration Control of Intelligent Structures via ER Fluids and Piezoelectric Film Actuators (전기유동유체와 압전필름 액튜에이터를 이용한 지능구조물의 진동제어)

  • 박용군;최승복
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.249-253
    • /
    • 1995
  • 본 연구에서는 잠재적 응용성이 큰 ER유체와 압전필름을 액튜에이터로 하는 하이브리드형 지능구조물을 제안한 후 능동 진동제어를 실시하였다. 먼저 중공(hollow)의 샌드위치 형태 복합재료(glass/epoxy)보에 ER유체와 압전필름을 각각 삽입과 접착을 하여 하이브리드형 지능구조물을 제작하였다. 그리고 각 매체의 액튜에이팅 특성을 고려하여, ER유체 액튜에이터(ERFA)는 전장부하 함수로 도출되는 구조물의 주파수응답을 특징으로 하였고, 압전필름 액튜에이터(PFA)는 신경 슬라이딩 모드 제어기 (neuro sliding mode controller : NSC)를 적용하였다. 이 두 액튜에이터가 동시에 작동하는 능동 진동제어계를 실험적으로 구현한 후 과도응답과 강제 응답에 대한 진동제어 성능을 단일 액튜에이터 작동시와 비교 고찰하여 제시된 하이브리드 액튜에이팅의 효과를 입증하였다.

  • PDF

The Estimation of the Floor Vibration in Structure for Application of Response Spectrum Analysis Method (응답스펙트럼 해석법을 이용한 건축 구조물의 바닥진동해석)

  • 이동근;김태호
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.2 no.4
    • /
    • pp.169-178
    • /
    • 1998
  • In general, the response spectrum analysis method is widely used for seismic analysis of building structures, and the time history analysis is applied for computation of structural vibration caused by equipments, machines and moving loads, etc. However, compared with the response spectrum analysis method, the time history method is very complex, difficult and time consuming. In this study, the maximum responses for the vertical vibration are calculated conveniently by the response spectrum method. At first, Response spectrum and time history analysis for some earthquake excitations are carried out, and the accuracy of maximum displacements obtained from response spectrum analysis is investigated. Secondly, the process for the response spectrum analysis in excitation is calculated, and the maximum modal responses are combined by CQC method. Finally, results of the proposed method are compared with those of the time history analysis.

  • PDF

Identification of Viscous and Friction Damping Using Free Vibration Response to SDOF System (단자유도계의 자유진동응답을 이용한 점성 및 마찰감쇠의 식별)

  • Lee, Sung-Kyung;Lee, Woong-Gu
    • The Journal of the Convergence on Culture Technology
    • /
    • v.5 no.3
    • /
    • pp.305-310
    • /
    • 2019
  • This paper proposes the method of exactly identifying both viscous and friction damping from free vibration response to SDOF structure. Both displacement and acceleration free vibration responses to SDOF system, in which both viscous and friction damping are considered as its damping mechanism, are discussed to verify the proposed method. The relationship for identifying both viscous and friction damping is derived from two consecutive amplitudes of displacement or acceleration peak response. The proposed method is verified through the numerical simulation for an assumed SDOF system consisting of mass, both viscous and friction damping and spring components.

Experimental Verification of a Liquid Damper with Changeable Natural Frequency for Building Response Control (고유진동수 조절이 가능한 액체댐퍼의 건물응답 제어실험)

  • Kim, Dong-Ik;Min, Kyung-Won;Park, Ji-Hun;Kim, Jae-Keon;Hwang, Kyu-Seok;Gil, Yong-Sik
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.25 no.4
    • /
    • pp.323-330
    • /
    • 2012
  • This study deals with the experiments of liquid dampers with multi cells whose vertical tubes are divided into several square columns for easily changing natural frequencies. Shaking table test is performed to verify control effectiveness of the dampers which are installed on a building structure. To design liquid dampers, a 64-story building structure is reduced to a SDOF structure with 1/20 of similitude laws based on acceleration. The structure model is made up to adjust its mass and stiffness easily, with separate mass and drive parts. Mass parts indicate real structure's weights and drive parts indicate real structure's stiffness with springs and LM guides. Manufactured liquid damper has 18 cells and its natural frequency ranges are 0.65Hz to 0.81Hz. Shaking table test is carried out with one way excitation to compare with only accelerations of a large-scale structure and a structure installed with liquid dampers. Control performance of the liquid damper is expressed by the transfer function from shaking table accelerations to the large-scale structure ones. Testing results show that the liquid damper reduced a large-scale structure's response by tuned natural frequencies.

A Study on the Vibration Responses of Piping Systems by Pulsation Flow (맥동류에 의한 파이프 계의 진동응답에 관한 연구)

  • Lee, Dong-Myung;Choi, Myung-Jin
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.6
    • /
    • pp.68-75
    • /
    • 1997
  • In this study, to investigate vibration response of piping systems due to pulsation flow, a transfer matrix method is presented. Fluid-pipe interaction is formulated using wave equation for flow velocity and pressure, which depends on position and time. From the wave equation, transfer matrix is obtained. The dynamic responses of piping systems induced by pulsation flow appeared to depend upon fluctuation fluid velocity and pressure occurrnece from pulsation, and beating phenomena were observed near the resonance. Consequently, the dynamic behaviors of piping systems appeared to the same as response characteristics of the inside flow pattern of the pipe, and are determined by the inside fluid flow.

  • PDF

Seismic Response Estimation and System Identification of Test Steel Structure Using Approximate Nonlinear Filter (비선형 근사필터에 강구조시험체의 지진응답추정 및 동특성식별)

  • 배기환;김두영
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.5 no.2
    • /
    • pp.67-72
    • /
    • 2001
  • 대상으로 하는 시스템의 입출력신호에 근거하여, 시스템의 수학적 모델을 결정하는 것을 총칭하여 시스템식별이라 한다. 본 논문에서는 지진응답 관측치를 입출력신호로 하여 조건부대치를 최적치로 판단하는 비선형근사필터법을 사용한 건축구조물의 지진응답추정 및 파라미터식별에 관하여 논한다. 비선형근사필터법에 의한 건축구조물식별의 유효성의 적용성을 판단하기 위해, 진동대를 사용하여 강구조시험체의 진동실험을 행하고 결과적으로 얻어진 시험체의 수학적 모델에 대한 지진응답 수치해석결과와 진동실험에서의 관측기록을 비교하여 본 식별법의 타당성을 보인다.

  • PDF