• Title/Summary/Keyword: 진동방지대

Search Result 27, Processing Time 0.023 seconds

Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test (비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가)

  • Lee, Jae-Sub;In, Sung-Woo;Jung, Dam-I;Lee, Doo-Yong;Lee, Sang-Hyen;Cho, Bong-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

A Study on the Prevention of Liquefaction Damage of the Sheet File Method Applicable to the Foundation of Existing Structures Using the 1-G Shaking Table Experiment (1-G 진동대 실험을 이용한 기존 구조물 기초에 적용 가능한 시트파일 공법의 액상화 피해 방지에 관한 연구)

  • Jongchan Yoon;Suwon Son;Junhyeok Park;Junseong Moon;Jinman Kim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.24 no.7
    • /
    • pp.5-14
    • /
    • 2023
  • Recently, earthquakes have occurred frequently in worldwide. These earthquakes cause various forms of natural and physical damage. In particular, liquefaction in which the ground shows liquid-like behavior causes great damage to the structure. Accordingly, various liquefaction damage reduction methods are being studied and developed. Therefore, in this study, a method of reducing liquefaction damage in the event of an earthquake applicable to existing structures was studied using the sheet pile method. The 1-G Shaking table test was performed and the ground was constructed with Jumunjin standard sand. A two-story model structure was produced by applying the similitude law, and the input wave applied a sine wave with an acceleration level of 0.6 g and a frequency of 10 Hz. The effect of reducing structure damage according to various embedded depth ratio was analyzed. As a result of the study, the structure settlement when the ground is reinforced by applying the sheet pile method is decreased by about 71% compared to when the ground is not reinforced, and the EDR with minimum settlement is "1". In addition, as the embedded depth ratio is increased, the calculation of the pore water pressure in the ground tends to be delayed due to the sheet pile. Based on these results, the relationship with structural settlement according to the embedded depth ratio is proposed as a relational equation with the graph. The results of this study are expected to be used as basic data in developing sheet pile methods applicable to existing structures in the future.

Eigen-Frequency of a Cantilever Beam Restrained with Added Mass and Spring at Free End or a Node Point (자유단 혹은 노드점에 작용하는 스프링과 부가질량을 받는 일단 지지보의 고유진동수)

  • Sim, Woo-Gun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.12
    • /
    • pp.32-40
    • /
    • 2018
  • In order to avoid excessive vibration, it is required to carry out a vibration analysis of heat-exchanger/nuclear-reactor at the design stage. Information of eigen-frequency in the vibration problem is required to evaluate safety of heat-exchange/nuclear reactor. This paper describes a numerical method, Galerkin's method, to solve the eigenvalue problem occurred in a cantilever beam. The beam is restrained with added mass and spring at the free end or a node point of a mode shape. The numerical results of eigen-frequency were compared with simple analytical and experimental results given by simple approach and simple test, respectively. It is found that Galerkin's method is applicable to estimate the eigen-frequency of the cantilever beam. The frequencies become lower with increasing the added mass and the frequencies increase with the spring force. It is shown the heavy added mass has a role of support on the flexible tube. The eigen-frequency of the first mode, for the system with the added mass mounted at the free end, can be calculated by the approximate analytical method existing with more or less accuracy.

Low Noise Breaker (저소음 브레이커 개발)

  • 김정태;전오성;윤병옥;이영화
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.213-216
    • /
    • 1995
  • 공사장의 건설기계 소음은 저주파 에너지를 많이 가지고 있기 때문에, 일단 소음이 발생되면 그 전파가 멀리까지 감쇄없이 진행하는 물리적 특징을 가지고 있으며 현실적으로 흡음재처리를 통한 소음방지효과는 저조한 실정이다. 특히, 선진국에서는 건설기계 등의 엄격한 소음 인증제도 실시로 인해 국내 일부 건설장비 생산제품이 외국에서 요구하는 소음규제치를 초과하기 때문에 저소음, 저진동 건설기계 설계 기술의 발전이 없으면, 향후 수출여건이 점차 어려워지고 있다. 이와같은 주변여건의 변화로 인해 건설기계를 생산하는 입체에서는 공사장 소음과 같은 저주파 에너지에 의해 지배 받는 소음문제를 효과적으로 저감시키기 위한 건설기계의 저소음, 저진동 설계의 필요성을 심각하게 인식하고 있는 실정이다. 건설기계중, 소음이 문제시되는 기계로는 지반정지공사, 기초공사, 콘크리트공사, 포장공사, 파괴 및 해체공사와 기타등 6가지가 있다. 이중에서 환경연구원의 연구결과에 따르면, 항타기, 브레이커 및 착암기가 높은 소음도를 나타내고 있다. 가장 높은 소음을 배출하고 있는 항타기는 기초 공사에 쓰이는 것으로써 지반 천공후 H빔을 싣는 디젤 항타기의 경우, 소음도가 107dBA를 보여주고 있다. 이 값은 기계로부터 7m 떨어진 거리에서 측정된 값이다. 또, 파괴 및 해제공사에 쓰이는 브레이커는 98dBA의 소음도를 보여주고 있다. 착암기는 작용원리에 따라 91-96dBA의 소음을 배출하고 있다. 본 연구에서는 건설기계중 소음이 높아 문제시 되고 있는 유압 브레이커의 저소음 설계기술개발에 관한 내용이다. 저소음 브레이커의 개발을 위해 소음에너지의 전달경로를 검토하고, 현실성있는 소음방지 대책을 제시하였다. 연구결과, 브레이커의 설계개량을 통해, 10dB의 소음저감효과를 볼 수 있어 만족스러운 결과를 도출할 수 있었다.타를 처리하기에는 부적절한 방법임이 널리 알려진 사실이다[3]. 최근에 Ben Mrad와 Fassois[4]는 신호에 잡음이 존재하여도 이를 잘 처리할 수 있는 확률적(stochastic) 방법을 개발하여 기존의 결정적 방법들과 그 결과를 비교하였다. 그러나, 개발된 방법은 응답 신호에 백색잡음(white noise)이 섞이는 특수한 경우에만 사용할 수 있게 만들어져서 이 방법의 실질적인 적용에는 어려움이 있다. 본 연구에서는 기존의 방법들의 단점을 극복할 수 있는 새로운 회귀적 모우드 변수 규명 방법을 개발하였다. 이는 Fassois와 Lee가 ARMAX모델의 계수를 효율적으로 추정하기 위하여 개발한 뱉치방법인 Suboptimum Maximum Likelihood 방법[5]를 기초로 하여 개발하였다. 개발된 방법의 장점은 응답 신호에 유색잡음이 존재하여도 모우드 변수들을 항상 정확하게 구할 수 있으며, 또한 알고리즘의 안정성이 보장된 것이다.. 여기서는 실험실 수준의 평 판모델을 제작하고 실제 현장에서 이루어질 수 있는 진동제어 구조물에 대 한 동적실험 및 FRS를 수행하는 과정과 동일하게 따름으로써 실제 발생할 수 있는 오차나 error를 실험실내의 차원에서 파악하여 진동원을 있는 구조 물에 대한 진동제어기술을 보유하고자 한다. 이용한 해마의 부피측정은 해마경화증 환자의 진단에 있어 육안적인 MR 진단이 어려운 제한된 경우에만 실제적 도움을 줄 수 있는 보조적인 방법으로 생각된다.ofile whereas relaxivity at high field is not affected by τS. On the other hand, the change in τV does not affect low field profile but strongly in fluences on both inflection

  • PDF

Study on Vibration Characteristics for Reducing Vibration of the Hopper-type Feeder (호퍼식급이기의 진동 저감을 위한 진동 특성 연구)

  • Lee, S.J.;Chang, D.I.;So, J.K.;Chang, H.H.;Yoon, T.J.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • This study was carried out to measure and analyze the vibration levels and modes produced by a hopper type feeder used at laying hen farms, to prevent the vibration resonance and to reduce the vibration of the hopper type feeder (6-tier). The most vibration in a layer house were produced by hopper type feeder as shown the previous study. According to the measurement results, the ratio of transmissibility was as high as 100-638% for natural frequency of 170 Hz or less. And vibration simulations were taken by the results of vibration mode analysis and the weakest points to vibrations were determined accordingly. Then measurement and analysis were taken for those points. The quantities of vibration were 4.6354-4.9118 g($g=9.81^m/s^2$) by axis. In this study, it was found that hopper type feeder generated vibration as much as to influence the ratio of laying eggs of layer. And by the analysis of vibration on the weakest points, design methods and equipment were suggested for isolating/reducing of vibration by each axis.

  • PDF

고진공펌프의 상태진단 시스템

  • Jeong, Wan-Seop;Nam, Seung-Hwan;Kim, Wan-Jung;Im, Jong-Yeon
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.101-101
    • /
    • 2012
  • 본 논문은 현재 제품화 단계로 진행 중인 터보 분자펌프(turbo-molecular pump, TMP)와 극저온 펌프(cryopump)의 고장 방지 및 예지 보수를 위한 상태 진단 시스템에 대하여 소개를 한다. 본 상태 진단 시스템은 고진공 펌프들의 다중 상태변수 즉 흡/배기부의 진공 압력, 부위별 온도, 소비 전류(혹은 전력), 그리고 부위별 진동 신호들을 실시간으로 측정하는 상태변수 수집장치, 수집된 시계열 상태변수들이 저장된 database, 그리고 저장된 상태변수를 이용한 고진공펌프의 상태진단 프로그램으로 구성되어 있다. 금번 연구에서 구축한 상태변수 체계의 특징 중 하나는 진동신호를 상태변수로 측정하여 이를 상태진단에 활용하는 점이 기존의 접근방법과 상이한 점이다. 실시간 신호 수집장치는 NI사 PXI 시스템 기반의 16채널 24-bit 동시 전압신호 측정 모듈, 8부위의 온도 측정장치(Lakeshore 218S, RS-232C 통신), 그리고 펌프의 소비전류/전력 측정장치(Hioki 3169, RS-232C), 그리고 고진공 펌프의 흡입 및 배기구의 진공도 측정장치로 구성하였다. 신호 수집용 프로그램은 NI사 Labview를 이용하여 작성하였다. 본 장치는 Nano-Fab 센터의 협조 하에 turbo-molecular 펌프와 cryopump측정 단에 각각 1대를 설치 완료하였으며 현재까지 운용 중이다. PC에 저장된 시계열 상태변수 database는 기 개발된 적응형 인자모델을 이용한 매개변수로 변환되며, 상태진단은 변환된 매개변수를 이용하여 수행할 예정이다.

  • PDF

3-D Finite Element Analyses of Steam Generator Tubes Considering the Gap Effects (간극효과를 고려한 증기발생기 전열관의 3차원 유한요소해석)

  • Cho, Young Ki;Park, Jai Hak
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.7 no.4
    • /
    • pp.51-56
    • /
    • 2011
  • Steam generator is one of the main equipments that affect safety and long term operation in nuclear power plants. Fluid flows inside and outside of the steam generator tubes and induces vibration. To prevent the vibration the tubes are supported by AVB (anti vibration bar). When the steam generator tube contact to AVB, it is damaged by the accumulation of wear and corrosion. Therefore studies are required to determine the effects of the gap between the steam generator tube and AVB. In order to obtain the stress and the displacement distributions of the steam generator tube, three dimensional finite element analyses were performed by using the commercial program ANSYS. Using the calculated the stress and the displacement distributions, the static residual strength of the steam generator tube can be evaluated. The results show that the stress and displacement of the steam generator tube increase significantly compared with the results from a zero-gap model.

부산신항 사석층 침하를 고려한 안벽기초의 침하량 분석

  • Gang, Yeon-Ik;Jeong, Jong-Beom;Yang, Sang-Yong
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2007.12a
    • /
    • pp.176-178
    • /
    • 2007
  • 부산신항 북컨테이너터미널 민차부두 1단계 공사에 적용된 안벽기초는 하부 대섬도 연약점토층 개량을 위한 SCP(Sand Compaction Pile) 개량층과 그 상부에 약 6m정도의 사석층으로 구성되어 있다. 안벽은 케이슨식으로 상부의 크레인 풍의 공용하중 작용시에 발생이 예상되는 안벽기초의 과도한 지반침하 방지를 위해 근고블럭에 의한 Preloading 공법이 적용되었다. 따라서, 프리로딩에 의한 하부기초지반의 침하관리가 중요 공사관리 포인트가 된다. 그러나, SCP층이나 사석총에 대한 침하량 예측은 반경험적 방법에 의존하기 때문에 실제와 상당한 차이가 발생하게 된다 본 연구에서는 사석층의 진동다짐에 의한 시공 특성을 반영하기 위해 굴착치환구간의 사석층에 대한 실측값을 이용하여 Terzaghi 변형식의 침하계수 a를 재산정하여 SCP개량구간에 적용함으로써 보다 합리적인 안벽기초의 침하량을 분석하였고 이를 사석층의 여성고 산정에 이용하였다.

  • PDF

MIRIS 우주관측카메라 FM Dewar 설계

  • Cha, Sang-Mok;Mun, Bong-Gon;Jeong, Ung-Seop;Lee, Dae-Hui;Nam, Uk-Won;Park, Yeong-Sik;Lee, Chang-Hui;Park, Seong-Jun;Lee, Deok-Haeng;Ga, Neung-Hyeon;Han, Won-Yong;Park, Jang-Hyeon;Seon, Gwang-Il;Yang, Sun-Cheol;Park, Jong-O;Lee, Seung-U;Lee, Hyung-Mok;Matsumoto, Toshio
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.40.2-40.2
    • /
    • 2010
  • MIRIS 우주관측카메라는 과학기술위성 3호의 주탑재체로서 $0.8{\sim}2.0{\mu}m$의 근적외선영역에서 우주배경복사와 우리은하 평면의 Pa-$\alpha$ survey 관측을 목적으로 한다. 이러한 임무를 수행하기 위해 MIRIS 우주관측카메라에는 MCT(HgCdTe) IR 검출기가 사용되고 6개의 필터를 장착할 수 있는 필터휠이 설계되었으며, 열잡음을 줄이고 원하는 SNR을 얻기 위해 모두 100K 이하로 냉각이 요구된다. 효과적인 냉각 및 저온유지를 위해서 외부의 열을 1차적으로 차단하는 Cryostat 외부용기와 100K 이하로 냉각되는 내부 Cold Box의 이중구조를 가지는 Dewar가 설계 되었다. 내부 Cold Box의 냉각은 소형 stirling cooler로 이루어지고 외부의 열 유입량이 Cooler의 냉각용량을 넘지 않도록 설계하였다. Cryostat 외부용기는 radiation cooling으로 냉각되어 200K 이하의 온도를 유지하며 내부 Cold Box로의 열유입을 최소화하기 위해 GFRP(Glass Fiber Reinforced Plastic) 단열 지지대와 MLI(Multi Layer Insulation)가 사용된다. 또한 100K으로 냉각시 필터고정부와 Cold Box 구조에서 일어날 수 있는 구조적인 피로도를 줄이고 열변형에 의한 문제를 방지하기 위한 고려가 설계에 포함되었다. FM(Flight Model)은 고진공 환경의 우주공간에서 문제가 발생하지 않도록 설계되었다. 또한 EQM 진동시험결과를 토대로 발사환경에서 발생하는 강한 진동을 견딜 수 있도록 FEM(Finite Elements Method) 구조해석을 통하여 필터고정부에 flexible structure 설계와 완충제를 추가하고 필터휠 구동부와 harness 고정부 및 cooler 지지부를 비롯한 전체 구조물에서 충분히 진동을 극복할 수 있도록 설계하였다.

  • PDF

A Case Study on the Boring-Hole Blasting for Offering of the Ground Vibration Source (지진동 Source 제공을 위한 심부 시추공발파 기술사례)

  • 조영곤;김희도;조준호
    • Tunnel and Underground Space
    • /
    • v.13 no.3
    • /
    • pp.187-195
    • /
    • 2003
  • This case study which is to make 2-Dimension earth's crust structures clearly is about the great boring-hole blasting to provide ground vibration source of the reflected wave research on the Korean Peninsula earth's crust structures research. For this study we've done blasting twice-500 ㎏/charge per delay, 1,000 ㎏/charge per delay, and the specifications of blasting are the following - dia.: 300 ㎜, boring-depth : 100m, besides, we used the explosives and electric detonators which have sufficient detonating velocity and very excellent safety, capacity of detonating, accurate delay time. We charged explosives into steel pipe with bulk type to avoid dead pressure by ground water. And then we tested about pipe airtight and blasting to certificate which has no problem by using on this study. In the results, we succeeded each blasting in Seosan, Youngdong. For the Peak Sum Vector(PSV) around the blasting at the main points, its real measured PSV is higher 180 % than estimated PSV with USBM. In this study we can't to be analysis of vibration velocity, but to be key providing vibration source.