• Title/Summary/Keyword: 진동량

Search Result 943, Processing Time 0.035 seconds

Characteristics on the Vertical Load Capacity Degradation for Impact driven Open-ended Piles During Simulated Earthquake /sinusoidal Shaking, (타격관입 개단말뚝의 동적진동에 의한 압축지지력 저감특성)

  • 최용규
    • Geotechnical Engineering
    • /
    • v.12 no.6
    • /
    • pp.51-64
    • /
    • 1996
  • After the model open-ended pile attached with strain gages was driven into a pressure chamber, in which the saturated microfine sand was contained, the static compression loading test was performed for that pile. Based on the test results, ultimate pile capacity was determined. Then, either simulated earthquake shaking or sinusoidal shaking was applied to the pile with the sustained certain level OP ultimate pile load. Then, pile capacity degradations characteristics during shaking were studied. Pile capacity degradation during two different shakings were greatly different. During the simulated earthquake shaking, capacity degradation depended upon the magnitude of applied load. When the load applied to the pile top was less than 70% of ultimate pile capacidy, pile capacity degradation rate was less than 8%, and pile with the sustained ultimate pile load had the degradation rate of 90%. Also, most of pile capacity degradation was reduced in outer skin friction and degradation rate was about 80% of ultimate pile capacity reduction. During sinusoidal shaking, pile capacity degradation did not depend on the magnitude of applied load. It depended on the amplitude and the frequency , the larger the amplitude and the fewer the frequency was, the higher the degradation rate was. Reduction pattern of unit soil plugging (once depended on the mode of shaking. Unit soil plugging force by the simulated earthquake shaking was reduced in the bottom 3.0 D, of the toe irrespective of the applied load, while reduction of unit soil plugging force by sinusoidal shaking was occurred in the bottom 1.0-3.0D, of the toe. Also, the soil plugging force was reduced more than that during simulated earthquake shaking and degradation rate of the pile capacity depended on the magnitude of the applied load.

  • PDF

Real-time Vibration Control of Bridges by MR damper and Lyapunov Control Algorithm (MR댐퍼 및 Lyapunov제어알고리즘을 이용한 교량 구조물의 실시간 진동제어)

  • Heo, Gwang-Hee;Jeon, Joon-Ryong;Park, Seung-Bum;Oh, Sung-Keun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.55-61
    • /
    • 2010
  • This paper is concerned with an experimental research to random vibration control caused by external loads specially in bridges which tend to be structurally flexible. Experimenting on a reduced structure modelled on Seohae Grand Bridge, we inflicted a reduced form of El-centro wave on the model structure to a proper proportion. On the center of its middle span, we placed a shear type MR damper which was to control its vibration and also acquire its structural responses such as displacement and acceleration at the same site. The experiments concerning controlling vibration were performed according to a variety of theories including un-control, passive on/off control, and Lyapunov stability theory. Its control performance was evaluated in terms of the peak absolute displacements, the peak absolute accelerations and the total power required to control the bridge which differ from each different experiment method. Among all the methods applied in this paper, case of Lyapunov control method turned out to be the most effective to reduces of displacement and acceleration. Also, this method could to decrease consuming of external power for vibration control. Finally, it was noteworthy that Lyapunov control method was specially effective in the vibration control employing a semi-active damper such MR damper.

Development of Technique for Predicting Horizontal Displacement of Retaining Wall Induced by Earthquake (지진시 옹벽의 수평변위 예측기법의 개발)

  • Lee, Seung-Hyun;Kim, Byoung-Il
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.5
    • /
    • pp.143-150
    • /
    • 2021
  • To develop the technique for predicting the horizontal displacement of a retaining wall induced by an earthquake, an equation of motion that depicts the retaining wall-soil vibrating system was derived. The resulting differential equation was solved using the Runge-Kutta-Nystr?m method. Considering the pre-mentioned derivation process, the analysis procedures for obtaining horizontal displacement induced by an earthquake were programmed. The core algorithm of the displacement-force relationship, which is the main engine of the developed program, was suggested. Considering the results obtained by adopting the developed program to the assumed retaining wall under an earthquake, the relationships between the time-displacement, time-force, and displacement-force were reasonable. According to the results computed by the program, the displacements to the front direction of the wall occurred, and the displacement per cycle converged after some cycles elapsed. Displacements with a natural period were calculated, which showed that the maximum displacement was observed when the natural frequency was slightly different from the excitation frequency rather than the same values of the two frequencies. This happens because the vibrating system was modeled by two springs with different stiffness.

A Study On Variance Estimation in Smoothing Goodness-of-Fit Tests (평활 적합도 검정에서의 분산추정의 영향)

  • Yoon, Yong-Hwa;Kim, Jong-Tae;Lee, Woo-Dong
    • Journal of the Korean Data and Information Science Society
    • /
    • v.9 no.2
    • /
    • pp.189-202
    • /
    • 1998
  • The goat of this paper is to study on variance estimation - Rice variance estimation, Gasser, Sroka and Jennen-Steinmetz's varince estimation - in smoothing goodness-of-fit tests. The comparisons of powers on test statistics are conducted by the change of variance, the number of oscillations, the amplitude of the alternative sample distribution.

  • PDF

Rainfall Runoff Simulation Using Grid-Based Distributed Model for a Small Agricultural Reservoir Watershed (격자기반 분포형모형을 활용한 농업용 저수지유역의 홍수유출모의)

  • Jung, In-Kyun;Park, Jong-Yoon;Kim, Seong-Joon
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2009.05a
    • /
    • pp.953-956
    • /
    • 2009
  • 본 연구는 농업용저수지유역을 대상으로 분포형 강우-유출모형을 적용해 봄으로서 차후 본 연구대상유역의 분포형 강우유출모형을 이용한 설계홍수량 산정에 활용해 보기 위한 사전연구이다. 농업용저수지유역을 대상으로 모의하기 위하여 자동수위계를 통하여 저수지 수위자료가 주기적으로 기록되고 있는 계룡저수지 유역($15.4km^2$)을 선정하였으며, 주요 공간매개변수는 30m 격자해상도로 구축하였다. 관측유량자료는 수위-내용적-방류량 관계곡선에 의하여 수위변화에 따른 내용적 변화량을 유입량으로 가정하여 환산토록 하였으며, 곡선의 진동이 다소 작고 상태가 양호한 3개 강우사상을 대상으로 분석하였다. 대상유역의 2개 강우관측소(복룡, 반포)의 강우량을 IDW 방법에 의해 공간분포시켜 적용하였으며, 모형의 분석결과, 결정계수($R^2$)는 평균0.88, 용적보존지수(VCI)는 평균 0.14, 첨두유량의 상대오차 ($EQ_p$)는 평균 $0.11m^3/s$로 분석되었다.

  • PDF

Evaluation of Power Generation of Hybrid Energy Harvesting Blocks applying the Piezoelectric Effects and Electromagnetic Induction Principle (압전 및 전자기 유도 기술을 적용한 하이브리드 에너지수확 블록의 발전량 평가)

  • Noh, Myung-Hyun;Lee, Sang-Youl
    • Proceedings of the KAIS Fall Conference
    • /
    • 2012.05b
    • /
    • pp.734-737
    • /
    • 2012
  • 에너지하비스팅이란 도시와 자연 환경 속에 상시 존재하지만 진동, 열, 빛 등과 같이 버려지는 에너지 소스로부터 전기를 수확하는 것으로 대용량 발전소와는 다른 신개념의 전기 수확 기술이다. 본 연구에서는 다양한 에너지 하비스팅 기술들 중에서 압전 원리와 전자기 유도 방식을 조합한 하이브리드 에너지 하비스팅 블록에 대한 발전량을 평가하여 에너지 하비스팅 블록의 주택 도시 분야 적용 가능성을 검토하고자 하였다. 이를 위해 랩스케일 PZT 기반 다층 에너지 하베스터의 현 발전량을 평가하여 제시하였고, 증폭기술을 적용하여 개발된 에너지 블록의 발전성능을 다각적으로 평가하여 제시하였다. 또한 개발된 에너지 블록과 기존 상용 제품과의 발전성능 비교 실험을 수행하여 개발된 에너지 블록의 우수성을 입증하였다.

  • PDF

A Study on Quantity and Quality of Non-point sources within the basin of Nak-Dong river using SWMM Model (SWMM 모형을 이용한 낙동강 수계 내 비점오염원 발생현황 분석)

  • Jang, Jong-Kyung;Shon, Tae-Suk;Shin, Hyun-Suk;Shin, Dong-Soo;Yoon, Young-Sam
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2011.05a
    • /
    • pp.265-269
    • /
    • 2011
  • 낙동강 수계 내 하천 환경 및 수자원에 대한 효율적인 유역관리를 위해 수계 내 비점오염원의 유출 및 오염물질 발생특성에 대한 정량적인 분석이 요구된다. 점오염원과 달리 강우뿐만 아니라 유역 내 지표상태 등 복잡하고 예측 곤란한 상황을 반영해야 하므로 정량화에 어려움이 따르게 된다. 수문학적 및 수리학적 분석이 가능할 뿐 아니라 수질모의가 가능한 SWMM을 활용하고 오염총량 단위유역과 댐유역을 고려한 소유역 분할을 적용함으로써 댐유역을 제외한 오염총량 단위유역별 비점오염원 분석결과를 산정하였다. 본 연구에서 산정된 유량을 기초로 낙본I 지점과 진동 수위표의 유황곡선을 비교하고 낙본I 지점의 월별 유출량 및 오염부하량 분석과 함께 유출량과 수질항목별 오염부하량의 상관관계를 분석하였다. 또한, 낙동강 수계 내 점오염원을 배제한 단위유역별 및 낙본I 지점의 비점오염원 발생특성을 분석하였다.

  • PDF

Voltage Compensation Method of Industrial Inverter for Motor Control (산업용 인버터의 출력전압 보상방법)

  • Jeong, Se-Jong;Kim, Seung-Hwan
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.39-40
    • /
    • 2015
  • 산업용 인버터에서 출력전압은 소자의 전압강하와 데드타임에 의해 왜곡이 발생되며, 이로 인해 출력 전류의 품질을 저하시키고 전동기 축 토크의 진동을 유발한다. 이러한 현상을 방지하기 위해서는 출력전류에 따라 출력전압을 보상하여야 한다. 하지만 임의의 스위칭 주파수에서 측정된 전압왜곡량으로 보상량을 결정할 경우, 스위칭 주파수가 변경되면 전압 왜곡이 커지게 된다. 따라서, 소자의 전압강하와 데드타임에 의한 전압 왜곡은 스위칭 주파수에 따라 적절히 변경되어야 한다. 본 연구에서는 인버터 전력소자의 전압강하량과 데드타임량을 개별 측정하여 보상하는 방법을 제시하였고, 그 유효성을 실험을 통해 검증하였다.

  • PDF

A Study on Examining the Calculation Including the Ease Amount for Bodice Pattern (여유량이 포함된 제도식 검증에 관한 연구-길원형을 중심으로)

  • Koo, Mi-ji
    • The Journal of Natural Sciences
    • /
    • v.9 no.1
    • /
    • pp.105-112
    • /
    • 1997
  • This study was carried out to examine the calculations including the ease amount for bodice pattern. The conclusions were as follows. The areas that were required the ease amount were the horizontal reference line, armhole depth, back & front width. According to this result the calculations including the ease amount were obtained as follows: B/2+4.1cm for horizontal reference line, B/6+6.8 cm for armhole depth, B/6+3.9 cm for the half of back width, B/6+2.3 cm for the half of front width, B/4+4.3 cm for bust point length.

  • PDF

A study on analysis of vibration and crack measurement data on granite-bed rock (화강암 지반에서 진동 및 크랙측정치 분석에 관한 연구)

  • Han, Dong-Hun;Ahn, Myung-Seog;Lee, Kwang-Yeol;Oh, Byung-Sam;Kang, Moon-Gu
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.5 no.3
    • /
    • pp.251-260
    • /
    • 2003
  • Tunnel blasting has been performed with V-cut to investigate the characteristics. Blasting vibrations were measured at two directions, the proceed direction and side direction. Propagation characteristics were determined by regression analysis; square root scaled distance and cube root scaled distance with maximum charge per delay of the blast. Testing result, The cross point was 62m in the allowable vibration velocity of 3mm/sec and 46m in 5mm/sec. Also, vibration level with measuring point was highest and decayed fastest, adapting to cube root scaled distance, for the proceed direction on ground.

  • PDF