• Title/Summary/Keyword: 진단용 방사선

Search Result 277, Processing Time 0.028 seconds

Occupational Radiation Exposure in Korea: 2002 (2002년 국내 방사선 작업종사자의 직업군별 피폭선량)

  • Jeong, Je-Ho;Kwon, Jeong-Wan;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.175-183
    • /
    • 2005
  • Dose distribution of Korean radiation workers classified by occupational categories was analyzed. Statistics of the occupational radiation exposure(ORE) in 2002 of the radiation workers in diagnostic and dental radiology were obtained from the Korea Food and Drug Agency(KFDA) who maintains the database for individual radiation dose records. Corresponding statistics for the rest of radiation workers were obtained by processing the individual annual doses provided by the Korea Radioisotope Association(KRIA) after deletion of individual information. The ORE distribution was classified in term of 28 occupational categories, annual individual dose levels, age groups and gender of 52733 radiation workers as of the year of 2002. The total collective dose was 66.4 man-Sv and resulting average individual ORE was 1.26 mSv. Around 80% of the workers were exposed to minimal doses less than 1.2 mSv. However, it appeared that the recorded doses exceeded 20 mSv for 43 workers in the industrial radiography and for 147 workers in the field of radiology. Particularly, recorded doses of 23 workers in radiology exceeded the annual dose limits of 50 mSv, which is extraordinary when the working environment is considered. It is uncertain whether those doses are real or caused by careless placing of dosimeters in the imaging rooms while the X-ray units are in operation. No one in the workforce of 16 operating nuclear power plant units was exposed over 20 mSv in 2002. Number of workers was the largest in their 30's of age and the mean individual dose was the highest in their 20's. Women were around 20% of the radiation workers and their average dose was around one half of that of man workers.

A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray (진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석)

  • Choi, Joon-Ho
    • Journal of radiological science and technology
    • /
    • v.42 no.6
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

HANARO Fission Moly Target으로서의 LEU와 HEU의 특성 비교

  • 조동건;김명현
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1997.05a
    • /
    • pp.108-113
    • /
    • 1997
  • 하나로(HANARO)를 이용하여 핵분열 방법으로 진단용 방사선원인 $^{99m}$ Tc의 모핵종인 Mo-99를 생산할 경우, HEU 및 LEU UO2 표적이 사용될 수 있다. 표적연료로서 HEU(93w/o $^{235}$ U)가 LEU(19.75w/o $^{235}$ U)에 비해 생성수율(Ci/gU)이 높게 나타났으며 제품의 질(quality)을 좌우하는 비방사능(Ci$^{99}$Mo/gMo)은 같게 나타났다. HEU가 같은 Mo-99의 방사능량을 얻기 위해서는 우라늄 장전량이 적어지므로 폐기물측면과 용해측면에서 이득이나 농축도를 고려하면, 큰 이득이 발생하지 않으므로 하나로에 LEU를 사용하는 것도 타당하다 할 수 있다.

  • PDF

Development of Convergence Core Technology for Cancer Prognosis from Circulating Tumor Cells (혈중 암세포 기반 암 예후 예측 진단 융합기술 개발)

  • Jung, M.Y.;Lee, D.S.;Park, J.W.;Shin, Y.K.;Kim, Y.D.
    • Electronics and Telecommunications Trends
    • /
    • v.29 no.5
    • /
    • pp.105-113
    • /
    • 2014
  • 주치의에게는 암환자의 암 전이 여부가 초미의 관심사다. 암환자의 10명 중 9명이 전이암으로 사망하기 때문이다. 암의 전이 초기에 그 전이 여부를 방사선 진단법으로 가능하지 않다. 혈액을 채취하여 암의 전이 유무를 진단 하는 기술이 개발되고 있다. 이 혈중 암세포는 혈구세포 10억개당 1~100개 정도의 극히 미량이 존재하여 암세포 분리기술이 특별히 잘 개발되어야 한다. 최근 마이크로바이오칩 형태의 분리기술이 큰 기술적 진화를 보이고 있어 본고에 소개하고자 한다. 이 기술은 한 가지 큰 의미를 갖는다. 그것은 암환자의 암 전이 모니터링에 필요한 도구가 될 수 있기 때문이다. 전이암세포 검출 키트로 전이암세포를 계수 하여 환자에게 투약한 항암제가 적합한지에 대한 답을 의사는 얻을 수 있다. 전이암세포 진단용 마이크로바이오칩 기술이 기존의 영상진단법만큼 중요한 임상 수단이 될 것으로 전망된다.

  • PDF

HVL Measurement of the Miniature X-Ray Tube Using Diode Detector (다이오드 검출기를 이용한 초소형 X선관(Miniature X-ray Tube)의 반가층 측정)

  • Kim, Ju-Hye;An, So-Hyeon;Oh, Yoon-Jin;Ji, Yoon-Seo;Huh, Jang-Yong;Kang, Chang-Mu;Suh, Hyunsuk;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.23 no.4
    • /
    • pp.279-284
    • /
    • 2012
  • The X ray has been widely used in both diagnosis and treatment. Recently, a miniature X ray tube has been developed for radiotherapy. The miniature X ray tube is directly inserted into the body irradiated, so that X rays can be guided to a target at various incident angles according to collimator geometry and, thus, minimize patient dose. If such features of the miniature X ray tube can be applied to development of X ray imaging as well as radiation treatment, it is expected to open a new chapter in the field of diagnostic X ray. However, the miniature X ray tube requires an added filter and a collimator for diagnostic purpose because it was designed for radiotherapy. Therefore, a collimator and an added filter were manufactured for the miniature X ray tube, and mounted on. In this study, we evaluated beam characteristics of the miniature X ray tube for diagnostic X ray system and accuracy of measuring the HVL. We used the Si PIN Photodiode type Piranha detector (Piranha, RTI, Sweden) and estimated the HVL of the miniature X ray tube with added filter and without added filter. Through an another measurement using Al filter, we evaluated the accuracy of the HVL obtained from a direct measurement using the automatic HVL calculation function provided by the Piranha detector. As a result, the HVL of the miniature X ray tube was increased around 1.9 times with the added filter mounted on. So we demonstrated that the HVL was suitable for diagnostic X ray system. In the case that the added filter was not mounted on, the HVL obtained from use of the automatic HVL calculation function provided by Piranha detector was 50% higher than the HVL estimated using Al filter. Therefore, the HVL automatic measurement from the Piranha detector cannot be used for the HVL calculation. However, when the added filter was mounted on, the HVL automatic measurement value using the Piranha detector was approximately 15% lower than the estimated value using Al filter. It implies that the HVL automatic measurement can be used to estimate the HVL of the miniature X ray tube with the added filter mounted on without a more complicated measurement method using Al filter. It is expected that the automatic HVL measurement provided by the Piranha detector enables to make kV-X ray characterization easier.

A comparison of conventional intraoral radiography and computer imaging techniques for the detection of proximal surface calculus (구내방사선사진과 컴퓨터영상의 치아 인접면 치석 진단능의 비교)

  • Kang Byung-Cheol
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.1
    • /
    • pp.23-28
    • /
    • 1994
  • 전남대학교 치과대학 학생을 대상으로 평행촬영법으로 촬영한 168장의 구내방사선사진을 디지털 영상으로 변환하여, 필름상의 치석 유무 판독 결과와 모니터상의 판독 결과를 비교하였다. 3명의 구강악안면방사선학 전공 치과의사가 판독을 하되 필름상의 판독 결과를 판정의 기준으로 하였다. 디지털 영상은 상업용 필름-비디오 변환장치, 486DX PC, 그리고 PcVision과 frame grabber을 이용하여 얻었다. 모니터상의 개개 구내방사선사진상은 700×480 pixel로 나타내었다. 디지털 영상의 치석진단의 sensitivity는 0.79-0.90(평균 0.86) 이었고, specificity는 0.03-0.43(평균 0.17) 이었다.

  • PDF

Construction of an ideal set-up model for lingual orthodontic treatment (설측 교정치료를 위한 셋업 모형 제작의 정밀도)

  • Bae, Gi-Sun;Son, Woo-Sung
    • The korean journal of orthodontics
    • /
    • v.35 no.6 s.113
    • /
    • pp.459-474
    • /
    • 2005
  • Making a precise and ideal set-up model is an essential part in the indirect bonding procedure for lingual orthodontic treatment. To evaluate the accuracy of the making a set-up model, 22 adult patients who received lingual orthodontic treatment with 4 bicuspid extractions were selected, and 3 sets of dental models (before, set-up, and after treatment) were measured using the set-up model gauge, an instrument for measuring the inclination and angulation of the clinical crowns on the dental model. Two sets of lateral cephalograms (before and after) from each patient were also evaluated. The mean difference between the before treatment model and the set-up model was $-3.93{\pm}6.98^{\circ}$ for the inclination and $1.87{\pm}5.79^{\circ}$ for the angulation. And the mean difference between the set-up model and the after treatment model was $-4.31{\pm}5.91^{\circ}$ labiolingually and $-2.16{\pm}3.27^{\circ}$ mesiodistally, The after treatment model differed from the before treatment model about $-8.24{\pm}5.39^{\circ}$ in inclination. There were no significant difference between the measured gauge that measured from the dental model using the set-up model gauge and the calculated gauge angle measured from the lateral cephalogram using constructed points and lines. Using the set-up model gauge, it is possible to evaluate the study model 3-dimensionally in relation with the patient's lateral cephalogram and establish whether the doctor's prescription or overcorrection is built in the set-up model precisely.

Development of Image Quality Evaluation Program for Digital Diagnostic Radiography (디지털진단의료영상 화질평가 프로그램 개발)

  • Kang, Bo-Sun
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.2
    • /
    • pp.5-10
    • /
    • 2008
  • Most of the diagnostic medical radiography are rapidly replaced by digital imaging systems recently. Although with the current transition of analog to digital most of the exposure conditions and parameters are still on the basis of film-screen analog system. Moreover the evaluation of acquired digital radiographic image is not fulfilled normally because of the difficulties in handling the digital raw data. The user friendly windows program for the evaluations of digital radiographic image was developed on the MatLab platform. The program has functions for the calculation of the contrast profile, NPS(noise power spectrum), MTF(modulation transfer function), and NEQ(noise equivalent quanta).

  • PDF

A Study on PAE of Tube Voltage of Diagnostic X-ray Units -At the area of Sungnam, Inchon, Seoul- (진단용(診斷用) X선장치(線裝置)의 관전압(管電壓) 백분율(百分率) 평균오차(平均誤差)에 관한 조사(調査) 연구(硏究))

  • Lim, Han-Young;Oh, Hyun-Joo;Kim, Young-Il
    • Journal of radiological science and technology
    • /
    • v.16 no.2
    • /
    • pp.45-50
    • /
    • 1993
  • In this paper, the PAE of tube voltage of 93 diagnostic X-ray units those are using at the 19 general hospitals and 9 local clinics in the area of Sungnam, Inchun, and Seoul have been surveyed. The results are summarized as following. 1. PAE of tube Voltage 70, 100KV at the 56 (60%) X-ray units were ${\pm}7%$ below, at the 8 units (9%), were ${\pm}7%$ above, and those 29 X-ray units (31%) were ${\pm}7%$ below or above with the 70, 100KV tube Voltage in a unit. 2. PAE ${\pm}7%$ below were 68 X-ray units, at the low tube voltage (70KV), and 76 X-ray units at the high tube Voltage (100KV). 3. For six year-use abofe, used X-ray units were PAE ${\pm}7%$ above, and so, the longer used years the more X-ray units became declined in those performance. 4. PAE of tube Voltage were better efficiency at the large capacity 30 X-ray units than small capacity 10. 5. PAE ${\pm}7%$ abovein were only 8 units among 84 diagnostic X-ray units in the general hospitals.

  • PDF

A Comparative Study on Output of Four Type Diagnostic X-ray Equipments (정류방식에 따른 진단용 X-선 장치의 출력비교)

  • Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.34-43
    • /
    • 1997
  • There are 4 types of equipment in diagnostic radiography. These are single phase, three phase, inverter type and condenser type X-ray generators. It is very confusing to make an adequate exposure factor and to know the usage of different type of X-ray generators. In this experiment, I explored a comparative study of outputs in 4 different type of X-ray units. I expect that this experiment could be helpful for manufacturer to make both the X-ray equipment better, In terms of Ideal exposure factors, thereby reducing the patient dose. Experimental results are as follow : 1) X-ray output The ratio of X-ray output of single, three phase and inverter type of X-ray generator was 1 : 1.6 : 2 without absorber and 1 : 2 : 2.6 with 20 mm aluminium absorber. 2) Beam quality The X-ray beam quality of single phase generator was proved to be softer than three phase and inverter type of generators by 0.4 mmAL and 0.55 mmAl HVL respectively. 3) Reproducibility Linearity of X-ray output Retroducibility of X-ray output met the regulation below CV 0.05 and linearity also met the regulation below 0.1 in 4 types of diagnostic X-ray generators. 4) The comparison of incident dose Three phase X-ray generator was 20% higher than two other X-ray generators in radiation dose to make same film density.

  • PDF